• 제목/요약/키워드: Graphite Carbon

검색결과 659건 처리시간 0.038초

고속전철용 소결 복합재의 마찰 특성평가 (The Brake Performance of Sintered Friction Materials Developed for High Speed Trains)

  • 정소라;홍의석;장호
    • Tribology and Lubricants
    • /
    • 제23권6호
    • /
    • pp.266-271
    • /
    • 2007
  • The brake performance of sintered friction materials for the high speed train was studied. In this study, newly developed sintered materials based on copper were compared with the commercial products for high speed trains. They were tested on a 1/5 scale dynamometer using low carbon steel disks. Effectiveness, fade, and recovery tests were carried out to examine friction performance and the change of disk thickness variation (DTV) during brake applications and noise propensity were also evaluated. Results showed that the two sintered friction materials exhibit similar friction coefficients and braking performance, whereas the newly developed friction material was superior in terms of DTV generation and noise propensity to the commercial friction material. The improvement of the newly developed friction material was attributed to the high graphite content which reduced the stick-slip phenomena and prevented uneven disk wear by producing friction films on the counter disk.

원공조치를 가진 탄소섬유강화 플라스틱 적층판의 피로수명에측 (Fatigue Life Prediction of Circular Notched CFRP Laminates)

  • 허재석;황운봉;박현철;한경섭
    • 대한기계학회논문집A
    • /
    • 제20권3호
    • /
    • pp.832-842
    • /
    • 1996
  • Fatigue life prediction and fatigue behavior of circular notched carbon fiber reinforced plastic laminates are presented. Point and average stress criteria by Whitney and Nuismer are generalized to fatigue fracture criteria for notched laminates. Residual strength degradation model and the assumptions on the stress redistribution are introduced during the derivation of prediction equations. S-N curve, Basquin's relation, and H and H's FLPE1 are chosen for evaluation of residual strength of unnotched laminates and six prediction equations are derived. Experiments are performed using Graphite/Epoxy laminates whose fiber orientation is $[0$^\circ$/+45$^\circ$/-45$^\circ$/90$^\circ$]s. Presented prediction equations are reasonably close to experimental data and proposed appoach is found to be suitable to predict fatigue life of notched composite laminates.

PECVD 장비를 이용해 증착시킨 DLC 박막의 첨가원소(a-C:H:X)에 따른 고내식, 내열 특성

  • 김준형;문경일;박종완
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.225-225
    • /
    • 2012
  • DLC (Diamind-Like Carbon) 코팅은 1970년대 이온주입기술을 통하여 개발된 것이 처음으로 알려져 있으며, 다이아몬드 구조인 SP3 구조와 그라파이트 구조인 SP2 구조가 혼재되어 있으면서 제조 방법에 따라 수소와 Si 및 다양한 금속을 내재시킬 수 있는 코팅 물질이다. DLC는 높은 경도, 내마모성, 윤활성, 표면조도 등 뛰어난 기계적 특성과 전기절연성, 화학적 안정성 그리고 높은 광학적 투과성을 가져 산업적 활용 잠재력이 높은 재료로 평가되고 있으며, 이외에도 낮은 공정 온도에서 증착할 수 있고, 고경도와 낮은 마찰계수를 가지고 있는 장점이 있다. 그러나, DLC가 열적으로 불안정하기 때문에 사용되는 환경이 $500^{\circ}C$ 이상이 되면 DLC는 자체의 성질을 잃고 거의 흑연에 가까운 물질이 되어버리는 문제가 있고, 또한 높은 압축응력과 기재와의 낮은 밀착력이 단점으로 나타나고 있다. 이에 본 연구는 그런 단점을 보완하고자 PECVD (Plasmas Enhanced Chemical Vapor Deposition) 방법으로 DLC박막에 여러 가지 첨가원소(F,Si,0)를 사용하여 증착시킨 후 400, 500, $600^{\circ}C$에서 1시간동안 열처리를 진행하였으며, 그에 따른 내열 특성을 평가하였다. 또한 염수분무 테스트를 통한 박막의 내식 특성을 평가하였다. DLC박막의 구조는 Raman Spectra을 통해, Sp3 (like diamond) peak와 Sp2 (like graphite) peak 의 혼재 여부를 분석하였고, FE-SEM을 이용하여 막의 표면 및 단면을 관찰하였다. 스크래치 테스트를 통해 DLC박막의 밀착력을 측정하였으며, 볼 온 디스크 타입의 Tribo-meter을 이용하여 마찰계수 변화를 관찰하였다. 또한 나노인덴터를 이용하여 미소경도를 측정하였다. 그 결과 일반 DLC 막에 비해 첨가원소가 함유된 DLC 박막에서 내식성 및 내열특성이 향상되었다.

  • PDF

Investigation of Water Safety in Non-treated Drinking Water with Trace Toxic Metals

  • Ly, Suw Young;Kim, Dae Hong;Lee, Ga Eun
    • Toxicological Research
    • /
    • 제29권3호
    • /
    • pp.211-215
    • /
    • 2013
  • The trace toxic metal copper was assayed using mercury immobilized on a carbon nanotube electrode (MCW), with a graphite counter and a reference electrode. In this study, a macro-scale convection motor was interfaced with a MCW three-electrode system, in which a handmade MCW was optimized using cyclic- and square-wave stripping voltammetry. An analytical electrolyte for tap water was used instead of an expensive acid or base ionic solution. Under these conditions, optimum parameters were 0.09 V amplitude, 40 Hz frequency, 0.01 V incremental potential, and a 60-s accumulation time. A diagnostic working curve was obtained from 50.0 to 350 ${\mu}g/L$. At a constant Cu(II) concentration of 10.0 ${\mu}g/L$, the statistical relative standard deviation was 1.78% (RSD, n = 15), the analytical accumulation time was only 60 s, and the analytical detection limit approached 4.6 ${\mu}g/L$ (signal/noise = 3). The results were applied to non-treated drinking water. The content of the analyzed copper using 9.0 and 4.0 ${\mu}g/L$ standards were 8.68 ${\mu}g/L$ and 3.96 ${\mu}g/L$; statistical values $R^2$ = 0.9987 and $R^2$ = 0.9534, respectively. This method is applicable to biological diagnostics or food surveys.

Microwave Plasma Process에 의한 N-Hexane으로부터 다이아몬드 박막제작 및 특성 (Fabrication and Properties of Diamond Thin-Film from N-Hexane by Using Microwave Plasma Process)

  • 한상보;권태진;박상현;박재윤;이승지
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.79-87
    • /
    • 2011
  • In this paper, the best conditions for the deposition of the high quality diamond thin-film from N-hexane as a carbon source in the microwave plasma process was carried out. Major parameters are the deposition time, flow rates of oxygen and hexane. The deposition time for the steady state thin-film was required more than 4[h], and the suitable flow rates of hexane and oxygen for the high-quality thin-film are 0.4[sccm] and 0.1~0.2[sccm], respectively. In addition, amorphous carbons such as DLC and graphite were grown by increasing the flow rate of hexane, and it decreased by increasing the flow rate of oxygen. Specifically, the growth rate is about 1.5[${\mu}mh-1$] under no addition of oxygen and it decreased about 60[%] as ca. 1.0[${\mu}mh-1$] with oxygen.

카본블랙류 미세입자 포집을 위한 유리섬유 필터백의 고분자 표면처리에 관한 연구 (A study on the Polymer surface treatment of GF-filter bag for collection of fine Particle like carbon black)

  • 이봉;최희락;문창권
    • 동력기계공학회지
    • /
    • 제12권3호
    • /
    • pp.55-59
    • /
    • 2008
  • In this paper, we have investigated on collection efficiency of fine particle of glass fiber-filter bag according to the surface treatment. The solution consisted of polytetrafluoroethylene(teflon), graphite powder, silicon resin and water was used as a basic surface treatment agent. Tensile strength of glass filter-bag increased with up to 3hrs and then decreased with surface treatment time. Tensile strength and initial modulus of the glass fiber-filter bag treated by iodine after basic surface treatment for 3hrs were lower than those of basic surface treatment for 3hrs, however collection efficiency and fracture strain were higher than those of basic surface treatment for 3hrs. Glass fiber-filter bag with lower initial modulus and more strain will be extend the durable period and the one treated by iodine after basic surface treatment 3or 3hrs is expected high collection efficiency of fine particle. This method makes it possible to manufacture glass fiber-filter bag of the optimum condition.

  • PDF

A study of detector size effect using Monte Carlo simulation

  • Park, Kwang-Yl;Yi, Byong-Yong;Vahc, Young W.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.36-38
    • /
    • 2004
  • The detector size effect due to the spatial response of defectors is one critical source of inaccuracy in clinical dosimetry and has been a subject of numerous studies. Conventionally, the detector response kernel contains all of the influence that the detector size has on the measured beam profile. Various analytic models for this kernel have been proposed and studied in theoretical and experimental works. Here, we use a method to determine detector response kernel simply by using Monte Carlo simulation and convolution theory. Based on this numerical method and DOSIMETER, an EGS4 Monte Carlo code, the detector response for a Farmer type ion chamber embedded in water phantom is obtained. There exists characteristic difference in the simulated chamber readings between one with carbon graphite wall and the other with Acrylic wail. Using the obtained response and the convolution theory, we are planning to derive the detector response kernel numerically and remove detector size effect from measurements for 6MV, 10${\times}$l0cm2 and 0.5${\times}$10 cm2 photon beam.

  • PDF

Electrochemical Activation of Nitrate Reduction to Nitrogen by Ochrobactrum sp. G3-1 Using a Noncompartmented Electrochemical Bioreactor

  • Lee, Woo-Jin;Park, Doo-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권8호
    • /
    • pp.836-844
    • /
    • 2009
  • A denitrification bacterium was isolated from riverbed soil and identified as Ochrobactrum sp., whose specific enzymes for denitrification metabolism were biochemically assayed or confirmed with specific coding genes. The denitrification activity of strain G3-1 was proportional to glucose/nitrate balance, which was consistent with the theoretical balance (0.5). The modified graphite felt cathode with neutral red, which functions as a solid electron mediator, enhanced the electron transfer from electrode to bacterial cell. The porous carbon anode was coated with a ceramic membrane and cellulose acetate film in order to permit the penetration of water molecules from the catholyte to the outside through anode, which functions as an air anode. A non-compartmented electrochemical bioreactor (NCEB) comprised of a solid electron mediator and an air anode was employed for cultivation of G3-1 cells. The intact G3-1 cells were immobilized in the solid electron mediator, by which denitrification activity was greatly increased at the lower glucose/nitrate balance than the theoretical balance (0.5). Metabolic stability of the intact G3-1 cells immobilized in the solid electron mediator was extended to 20 days, even at a glucose/nitrate balance of 0.1.

단결정 실리콘 잉곳 결정성장 속도에 따른 고-액 경계면 형성 및 Defect 최적화 (Melt-Crystal Interface Shape Formation by Crystal Growth Rate and Defect Optimization in Single Crystal Silicon Ingot)

  • 전혜준;박주홍;블라디미르 아르테미예프;정재학
    • Current Photovoltaic Research
    • /
    • 제8권1호
    • /
    • pp.17-26
    • /
    • 2020
  • It is clear that monocrystalline Silicon (Si) ingots are the key raw material for semiconductors devices. In the present industries markets, most of monocrystalline Silicon (Si) ingots are made by Czochralski Process due to their advantages with low production cost and the big crystal diameters in comparison with other manufacturing process such as Float-Zone technique. However, the disadvantage of Czochralski Process is the presence of impurities such as oxygen or carbon from the quartz and graphite crucible which later will resulted in defects and then lowering the efficiency of Si wafer. The heat transfer plays an important role in the formation of Si ingots. However, the heat transfer generates convection in Si molten state which induces the defects in Si crystal. In this study, a crystal growth simulation software was used to optimize the Si crystal growth process. The furnace and system design were modified. The results showed the melt-crystal interface shape can affect the Si crystal growth rate and defect points. In this study, the defect points and desired interface shape were controlled by specific crystal growth rate condition.

Biological Assay of Mercury and Cadmium Ions Using DNA Immobilized on a Nanotube Paste Electrodes

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Hong-Rak;Park, Kwang-Ho;Park, Yong-Keun;Suk, Hong-Woo
    • 한국응용과학기술학회지
    • /
    • 제29권2호
    • /
    • pp.302-310
    • /
    • 2012
  • Bio assay of mercury and cadmium ions were searched using voltammetric analysis using DNA doped carbon nanotube paste electrodes (DCP). The square-wave stripping voltammetryic optimized results indicated working ranges of 1-10.0 $ngL^{-1}$ and 20-100 $ugL^{-1}$, Hg(II) Cd(II) within an accumulation time of 120 seconds, in 0.1-M phosphate buffer solutions of pH 6.3. The relative standard deviations of 5 $ngL^{-1}$ Hg(II) and Cd(II) that observed were 0.14 and 0.22% (n=12), respectively, using optimum conditions. The low detection limit (S/N) was pegged at 0.1 $ngL^{-1}$ ($4.9{\times}10^{-11}M$) Hg(II) and 0.2 $ngL^{-1}$ ($1.77{\times}10^{-10}M$) Cd(II). The developed methods can be applied to assays in biological fish kidneys and water samples.