• 제목/요약/키워드: Graphical substitution

검색결과 5건 처리시간 0.019초

Signal-flow graph에 의한 회로분석 (Network analysis by signal-flow graph)

  • 김형갑
    • 전기의세계
    • /
    • 제17권2호
    • /
    • pp.11-15
    • /
    • 1968
  • One of the most important methods used in the modern analysis of linear networks and systems is the signal flow graph technique, first introduced by S.J. Mason in 1953. In essence, the signal-flow graph technique is a graphical method of solving a set of simultaneous. It can, therefore, be regarded as an alternative to the substitution method or the conventional matrix method. Since a flow-graph is the pictorial representation of a set of equations, it has an obvious advantage, i.e., it describes the flow of signals from one point of a system to another. Thus it provides cause-and-effect relationship between signals. And it often significantly reduces the work involved, and also yields an easy, systematic manipulation of variables of interest. Mason's formula is very powerful, but it is applicable only when the desired quantity is the transmission gain between the source node and sink node. In this paper, author summarizes the signal-flow graph technique, and stipulates three rules for conversion of an arbitrary nonsource node into a source node. Then heuses the conversion rules to obtain various quantities, i.e., networks gains, functions and parameters, through simple graphical manipulations.

  • PDF

State Transition Diagram을 이용한 신규 정보통신 서비스의 대체/보완관계 분석: 와이브로(WiBro) 서비스를 중심으로

  • 안재현;김문구;한상필;박봉원;이상윤;방영석
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2004년도 추계학술대회 및 정기총회
    • /
    • pp.304-316
    • /
    • 2004
  • When new services are introduced, one of the drivers for market performance of them is the interactions among existing and new services. They are characterized by the substitution or complementary effects among existing and new service or the cannibalization of existing services by new services. This paper analyzes these issues in the telecommunications service industry context. To analyze them, a simple graphical tool or State Transition Diagram(STD) is developed and used. The diagram helps to clearly represent and explain the substitution, complement and cannibalization impact. Then, using the face-to-face survey of 1,200 people, a new wireless internet access service or WiBro is analyzed to identify the substitution/complement and cannibalization impacts in relation with the other competing services. Additionally, the important factors explaining customer subscription and substitution behavior are identified. The analysis results indicate that males, students or on-line game users are more likely to subscribe WiBro. Also, among the potential WiBro subscribers, customers who are less satisfied with the existing fixed line broadband internet access services are more likely to stop subscribing the fixed line service, which implies substitution by a new service. Additionally, this raises the issue of cannibalization if the existing and new services are provided by the same company. In fact we find the cannibalization effect is more serious for the cost sensitive group. We believe that our tool, approach, analysis results and their implications would be very helpful to devise a winning strategy for the new services in the highly uncertain telecommunications business environment.

  • PDF

THE GRAPHICAL D-Q TRANSFORMATION OF GENERAL POWER SWITCHING CONVERTERS

  • Rim, Chun-T.;Hu, Dong-Y.;Cho, Gyu-H.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.388-393
    • /
    • 1988
  • New circuit D-Q transformation concept is introduced to analyze AC converters such as inverters, rectifiers and cyclo-converters with ease. The equivalent linear time invariant circuit is obtained by substituting switches with equivalent turn-ratio variable transformers and changing balanced AC reactors into equivalent DC reactors combined by gyrators. This circuit enables us to utilize the powerful linear system analysis techniques such as Laplace transform otherwise which could not be applied to the time varying switching systems. Direct substitution of switches of DC converters with transformers is shown as a preliminary. Then the modeling procedure is shown for a controlled rectifier-inverter circuit. Finally an analysis example is proposed for a buck-boost inverter and the result is compared with the conventional approach. This approach is applicable to all AC converter families to determine the AC transfer functions and the DC operating points. It is identified that the switching systems are equivalent to the RLC filter circuits with transformers and gyrators.

  • PDF

피싱/파밍 예방을 위한 인지기반 접근 방법 (Cognitive Approach to Anti-Phishing and Anti-Pharming: Survey)

  • 홍성혁
    • 중소기업융합학회논문지
    • /
    • 제3권2호
    • /
    • pp.33-39
    • /
    • 2013
  • 현대에는 피싱 공격을 방지하는 여러 방법들이 연구 되고 있다. 이들 중에서는 작업관리창이나 브라우저의 주소창에서 피싱 사이트를 구별해 주는 프로그램들이 있다. 그러나 이런 프로그램들은 해당 사이트의 도메인이나 IP주소로 피싱 여부를 판단한다. 이 방법으로는 DNS 파밍 같은 공격은 방어할 수 있지만 숨겨진 공격(예를 들어 HTML 코드를 변경하는 기법)에는 매우 취약하다. 이 논문에서는 프로그램이 IP 나 사이트의 도메인을 분석하여 피싱 및 파밍 여부를 판단하는 기존의 방식이 아닌 플러그인과 서버 사이에서 HTML 코드의 변경 유무를 파악하고 피싱 여부를 팝업이나 플래시 등으로 위조하기 어려운 시스템 트레이와 풍선도움말을 사용하여 접속 사이트와 시스템 트레이의 그림을 사용자가 비교함으로서 직접 피싱 및 파밍 여부를 쉽게 분별할 수 있도록 하는 이미지 비교를 통한 인지 기반의 접근 방법을 제시한다.

  • PDF

피싱 및 파밍 방지를 위한 인지 기반의 접근 방법 (Cognitive Approach to Anti-Phishing and Anti-Pharming)

  • 김주현;맹영재;양대헌;이경희
    • 정보보호학회논문지
    • /
    • 제19권1호
    • /
    • pp.113-124
    • /
    • 2009
  • 현재 피싱 공격을 방지하는 여러 가지 기법들이 연구 되고 있다. 이들 중에서 작업관리창이나 브라우저의 주소창에서 피싱 사이트를 구별해 주는 프로그램들이 있으나 이런 프로그램들은 사이트의 도메인이나 IP주소로만 피싱 사이트를 판단한다. 이 접근 방법으로는 DNS 파밍 공격 등은 방어할 수 있지만 숨겨진 공격(Hidden Attack) 등의 HTML 코드를 변경하는 기법에는 취약하다. 이 논문에서는 프로그램이 IP 나 사이트의 도메인을 분석하여 피싱 및 파밍 여부를 판단하는 기존의 방식이 아닌 플러그인과 서버 사이에서 HTML 코드의 변경 유무를 파악하고 피싱 여부를 팝업이나 플래시 등으로 위조하기 어려운 시스템 트레이와 풍선도움말을 사용하여 접속 사이트와 시스템 트레이의 그림을 사용자가 비교함으로서 직접 피싱 및 파밍 여부를 쉽게 결정할 수 있도록 하는 이미지 비교를 통한 인지 기반의 접근 방법을 제시한다.