• Title/Summary/Keyword: Graph Slope

Search Result 51, Processing Time 0.025 seconds

The clinical manifestation of tension-type headache and correlation study with autonomic bioelectric response (긴장형(緊張型) 두통(頭痛)의 임상양상(臨床樣相) 및 생체전기 자율반응과의 상관성(相關性) 고찰(考察))

  • Choung, In-tae;Lee, Sang-hoon;Choi, Do-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.2
    • /
    • pp.183-203
    • /
    • 2004
  • Objective : Tension-type headache is the most common headache. The objective of this study is to find the clinical manifestation of tension-type headache and correlation with autonomic bioelectric response. Methods : This observation was carried out on 60 patients with tension-type headache. We used headache questionnaire and the Autonomic Bioelectric Response recoder(ABR-2000) for this study. Results : 1. Distribution of sex & age : male : female=5 : 7, 50s&60s group (28.3%) 2. Duration of onset : over 5years(50%), over one years(83.4%) 3. Causes of illness : stress(58.3%), severe fatigue(53.5%), tension(33.3%) 4. Time of attack : irregular(56.7%), day time(16.7%) 5. Pattern of pain: heavy(31 people), stiffness of occipital region (27 people) tightening around the head(25 people) 6. Curve : 40%, 56.7%, 35.0% SL(Slope low) at peak 1, 2, 3/ SH&SI not found 7. Regulation : 16.7% RR(Regulation reverse) at peak 1, 25% RH(Regulation high) at peak 2, 15% RR(Regulation reverse) at peak 3 8. Graph : Activity-60.0%, 70.0%, 63.3% lowered reaction(L, LR, L!) at peak 1, 2, 3 Reactivity-83.3%, 95.0%, 93.3% lowered reaction at peak 1, 2, 3 Conclusion : We find tension-type headache has remarkable relativeness with autonomic bioelectric response.

  • PDF

Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor (광전용적맥파 센서를 이용한 맥파전달시간의 측정)

  • Choi, Byeong-Cheol;Jung, Dong-Keun;Jeong, Do-Un;Ro, Jung-Hun;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

Field emission properties of boron-doped diamond film (보론-도핑된 다이아몬드 박막의 전계방출 특성)

  • 강은아;최병구;노승정
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.2
    • /
    • pp.110-115
    • /
    • 2000
  • Deposition conditions of diamond thin films were optimized using hot-filament chemical vapor deposition (HFCVD). Boron-doped diamond thin films with varying boron densities were then fabricated using B4C solid pellets. Current-voltage responses and field emission currents were measured to test the characteristics of field emission display (FED). With the increase of boron doping, the crystal size of diamond decreased slightly, but its quality was not changed significantly in case of small doping. The I-V characterization was performed for Al/diamond/p-Si, and the current of doped diamond film was increased $10^4\sim10^5$ times as compared with that of undoped film. In the field emission properties, the electrons were emitted with low electric field with the increase of doping, while the emission current increased. The onset-field of electron emission was 15.5 V/$\mu\textrm{m}$ for 2 pellets, 13.6 V/$\mu\textrm{m}$ for 3 pellets and 11.1 V/$\mu\textrm{m}$ for 4 pellets. With the incorporation of boron, the slope of Fowler-Nordheim graph was decreased, revealing that the electron emission behavior was improved with the decrease of the effective barrier energy.

  • PDF

Design and Implementation of IoT-Based Intelligent Platform for Water Level Monitoring (IoT 기반 지능형 수위 모니터링 플랫폼 설계 및 구현)

  • Park, Jihoon;Kang, Moon Seong;Song, Jung-Hun;Jun, Sang Min
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.4
    • /
    • pp.177-186
    • /
    • 2015
  • The main objective of this study was to assess the applicability of IoT (Internet of Things)-based flood management under climate change by developing intelligent water level monitoring platform based on IoT. In this study, Arduino Uno was selected as the development board, which is an open-source electronic platform. Arduino Uno was designed to connect the ultrasonic sensor, temperature sensor, and data logger shield for implementing IoT. Arduino IDE (Integrated Development Environment) was selected as the Arduino software and used to develop the intelligent algorithm to measure and calibrate the real-time water level automatically. The intelligent water level monitoring platform consists of water level measurement, temperature calibration, data calibration, stage-discharge relationship, and data logger algorithms. Water level measurement and temperature calibration algorithm corrected the bias inherent in the ultrasonic sensor. Data calibration algorithm analyzed and corrected the outliers during the measurement process. The verification of the intelligent water level measurement algorithm was performed by comparing water levels using the tape and ultrasonic sensor, which was generated by measuring water levels at regular intervals up to the maximum level. The statistics of the slope of the regression line and $R^2$ were 1.00 and 0.99, respectively which were considered acceptable. The error was 0.0575 cm. The verification of data calibration algorithm was performed by analyzing water levels containing all error codes in a time series graph. The intelligent platform developed in this study may contribute to the public IoT service, which is applicable to intelligent flood management under climate change.

Respiratory Effort Monitoring Using Pulse Transit Time in Human (인체에서 맥파전달시간을 이용한 호흡노력 모니터링)

  • 정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.485-489
    • /
    • 2002
  • In this study. respiratory efforts were monitored by the change of pulse transit time (PTT) which is related with the arterial pressure PTT is the time interval between the peak of R wave in ECG and the maximal slope point of photoplethysmogram(PPG). Biosignals, ECG and finger photoplethysmogram(PPG), were converted to digital data, and PTT was evaluated in personal computer with every heart beat. Results were presented as a graph using spline interpolation. The software was implemented in C$\^$++/ as a window-based application program. PTT was periodically changed according to airflow in resting respiration. In the resting respiration, PTT was changed according to the respiratory cycle. The amplitude of PTT fluctuation was increased by deep respiration, and increased by partial airway obstruction. These results suggest that PTT is responsible to respiratory effort which could be evaluated by the pattern of PTT change. And it is expected that PTT could be applied in the monitoring of respiratory effort by noninvasive methods, and is very useful method for the evaluation of respiratory distress.

The effects GyeongshinhaeGihwan 1 (GGT1) has on the hGHTg (human growth hormone transgenic) obese male rats' body weight and their amount of feed intake (형질전환 비만모델 수컷 hGHTg rats에서 경신해지환(輕身解脂丸)(GGT1)이 체중 및 사료섭취량에 미치는 영향)

  • Jung, Yang-Sam;Choi, Seung-Bae;Kim, Hoon;Shin, Soon-Shik
    • The Korea Journal of Herbology
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • Objectives: To find out the effects GGT1, an antiobestic drug widely used clinics, has on the amount of feed intake, the amount of change in the body weight and the food efficiency ratio using the data from the hGHTg obese male rats. Also, to evaluate in terms of antiobestic effects, the difference between GGT1 and reductil (sibutramine), which has been approved by the FDA of the United States. Methods: We measured the change in body weight and the amount of feed intake for 8 weeks by categorizing the hGHTg obese male rats into three groups: the control group, the GGT1 group, and the reductil (RD) group. We also evaluated the antiobestic effect by calculating the food efficiency ratio, which is the increase of bodyweight divided by the amount of feed intake. Results: In case of body weight, moderate slope of the curve in the graph of GGT1 group could mean that the weight is decreasing as time flows. In case of food efficiency ratio, the p-value was 0.745 in a test for determining if an interaction exists between the group and the point of measurement, meaning that it does not exist; also, the p-value in a test for the effect of level of repetition in food efficiency ratio according to the point of measurement equaled 0.002. Conclusion: The drug-treated groups had a greater inhibitory effect in feed intake than the control group. The results showed the food efficiency ratio had a tendency to decrease. The GGT1 group in particular was under a greater effect than the RD group.

  • PDF

Analysis of Acoustic Emission Signals during Long-Term Strength Tests of Brittle Materials (취성재료의 장기 강도시험 중 미소파괴음 신호 분석)

  • Cheon, Dae-Sung;Jung, Yong-Bok
    • Tunnel and Underground Space
    • /
    • v.27 no.3
    • /
    • pp.121-131
    • /
    • 2017
  • We studied the time-dependent behaviors of rock and concrete materials by conducting the static and dynamic long-term strength tests. In particular, acoustic emission(AE) signals generated while the tests were analyzed and used for the long-term stability evaluation. In the static subcritical crack growth test, the long-term behavior and AE characteristics of Mode I and Mode II were investigated. In the dynamic long-term strength test, the fatigue limit and characteristics of generation of AE were analyzed through cyclic four points bending test. The graph of the cumulative AE hits versus time showed a shape similar to that of the creep curve with the first, second and third stages. The possibility for evaluating the static and dynamic long-term stability of rock and concrete is presented from the log - log relationship between the slope of the secondary stage of cumulative AE hits curve and the delayed failure time.

Particle Behavior of Silver Nanoparticles Synthesized by Electrical Resistance Analysis (전기저항 분석을 통한 은나노 입자 합성 시의 입자거동 연구)

  • Yoon, Young Woo;Ryu, Si Hong;Yang, Sung Joo;Lee, Seong Eui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.531-538
    • /
    • 2015
  • This study examined the size and shape of the nano-silver particle through the analysis of electrical resistance when synthesizing nano-sized silver by using the chemical liquid reduction. Changes in particle behaviors formed according to the changes in electronic characteristics by electric resistance in each time period in the beginning of reduction reaction in a course of synthesizing the nano-silver particle formation were studied. In addition, analysis was conducted on particle behaviors according to the changes in concentration of $AgNO_3$ and in temperature at the time of reduction and nucleation and growth course when synthesizing the particles based on the particle behaviors were also examined. As the concentration of $AgNO_3$ increased, the same amount of resistance of approximately $5{\Omega}$ was increased in terms of initial electronic resistance. Furthermore, according to the result of formation of nuclear growth graph and estimation of slope based on estimated resistance, slops of $6.25{\times}10^{-3}$, $2.89{\times}10^{-3}$, and $1.85{\times}10^{-3}$ were derived from the concentrations of 0.01 M, 0.05 M, and 0.1 M, respectively. As the concentration of $AgNO_3$ increased, the more it was dominantly influenced by the nuclear growth areas in the initial phase of reduction leading to increase the size and cohesion of particles. At the time of reduction of nano-silver particle, the increases of initial resistance were $4{\Omega}$, $4.2{\Omega}$, $5{\Omega}$, and $5.3{\Omega}$, respectively as the temperature increased. As the temperature was increased into $23^{\circ}C$, $40^{\circ}C$, $60^{\circ}C$, and $80^{\circ}C$, slopes were formed as $4.54{\times}10^{-3}$, $4.65{\times}10^{-3}$, $5.13{\times}10^{-3}$, and $5.42{\times}10^{-3}$ respectively. As the temperature increased, the particles became minute due to the increase of nuclear growth area in the particle in initial period of reduction.

Diagnosis of Chronic Kidney Disease using Sonography (초음파 영상을 이용한 만성 콩팥병의 진단)

  • Ahn, Yu-Ji;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Chronic kidney disease can be treated if it is detected early, but as the disease progresses, it becomes impossible to recover. Finally, renal replacement therapy such as transplantation or dialysis should be used. Ultrasonography is used to diagnose kidney cancer, inflammatory disease, nodular disease, and chronic kidney disease. It is used to identify information about degree of inflammation using information such as kidney size, internal echo characteristics. Currently, the degree of disease in the clinic uses the value of glomerular filtration rate. However, even in ultrasound, changes in the degree of inflammation and disease can be observed. In this study, we used ultrasound images to quantify the changes in brightness, size, cortex, and subclinical changes of the kidney with progression of the disease, and compared them with the glomerular filtration rate used in clinical practice. In 105 cases, we performed 35 cases of normal kidney, 35 cases of early kidney disease, and 35 cases of terminal kidney. The brightness of the cortex of the image was obtained and the difference in brightness between the cortex and the proximal portion was obtained by the slope. The graph of the portion which was not smooth due to the ultrasonic characteristics was used as the function regrass. The size reduction was obtained from the original data. The results were as follows: It was proportional to the glomerular filtration rate. It is considered that the algorithm can be applied to the disease if the algorithm study continues.

A Study for Optimized Detecter Location Considering the Traffic Characteristics in National Highway (일반국도 통행특성을 고려한 지점검지기의 적정설치지점 선정에 관한 연구)

  • Byeon, Sang-Cheol;Lee, Seung-Jae
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.2 s.88
    • /
    • pp.19-30
    • /
    • 2006
  • This study deals with the optimized detector location considering the traffic characteristics in National Highway. Although there ave many construction works for ITS in National Highway, there is not specific criteria for detector location which can effect the accuracy of traffic information. This study. therefore. aims to Provide the optimized detector location criteria which can represent the traffic characteristics of National Highway. It collects traffic factors of study area by GPS Probe-car and defector, and Presents the optimized detector location by the correlation analysis between spot-speed and link-travel-time. The main results of this study are as followings ; First, the correlation between the spot-speed and link-travel-time Presents the opposite bell shape of the graph (U-type owe) which is increased it?on the upstream then, declined through some unspecified Point of the link. Second, the optimized detector location usually distributes around midstream of link, even though it does not have a consistency. Third, therefore, the optimized detector location generally should be located between $55{\sim}60%$ of total link length. Forth. high level of vertical slope is one of the most important factors of detector location, so it should be excluded for determination of optimized detector location. Finally, expecting that the results of this study would improve the accuracy of travel time estimation and forecasting.