• Title/Summary/Keyword: Graft-stent

Search Result 96, Processing Time 0.022 seconds

Endovascular Placement of Self-Expandable Stent-Graft for the Treatment of Aortic Aneurysms -2 cases- (자가팽창성 Stent-graft의 경관적 설치술을 이용한 대동맥류의 치료 -2 예 보고-)

  • 신현우;이재성
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.99-102
    • /
    • 2000
  • The usual treatment for aortic aneurysms is surgical replacement with a prosthetic graft; however the associated morbidity and mortality rates must be considered. Endovascular placement of self-expandable stent-graft is a safe noninvasive treatment that can be an alternative to the surgical repair, the postoperative course of the 2 cases of thoracoabdominal aortic aneurysms was uneventful and no complication has been associated with the stent-graft during the 17 months and 5 months follow-up studies,.

  • PDF

Hydrodynamic Characteristics of Self-expandable Graft Stents in Steady Flow (정상유동에서 자가팽창성 그래프트 스텐트의 수력학적 특성)

  • 이홍철;김철생;박복춘;박복춘
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • This experimental study is aimed at evaluating the hydrodynamic performance of newly designed self-expandable graft stents under steady flow condition. Two graft stents with different coating materials and a bare TiNi metallic stent for comparison test were used in the experiment. Pressure variation and velocity distribution at the upstream and downstream of the stents were measured at flow rates of 5, 10, and 15 l/min, respectively. Pressure loss due to insertion of the stent increased with increasing flow rate exponentially as expected. At a flow rate of 15 l/min, pressure loss of Polyure-thane(PU)-coated graft stent was 6 times higher than that of TiNi metallic stent, while the pressure loss of a porous Polytetrafluoroethylene(PTFE)-coated graft stent was comparable to a bare TiNi metallic stent. Velocity profiles of the porous PTFE-coated graft stent were similar to those of a bare TiNi metallic stent regardless of flow rate. Furthermore, the velocity profile of PU-coated graft stent revealed an asymmetrical and relatively low central velocity at a higher flow rate than 10 1/min, expecially, where the effects resulted in increases of wall shear stress and normal stress. The worse hydrodynamic behavior of PU-coated graft stent than the other two stents might be attributed to formation of folds due to poor flexibility of coated material when inserting the graft stent into the pipe with a more smaller size, which later gave rise non-symmetry of flow area, increase of surface roughness and jet flow via the crevice between the stent and cylinder wall.

Jejunal Migration of the Stent-Graft Used for Common Hepatic Artery Pseudoaneurysm (총간동맥 가성동맥류의 치료로 삽입한 스텐트 그라프트의 공장으로의 위치 이동)

  • Jiwon Kim;Byung-Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.189-193
    • /
    • 2022
  • Hemorrhage after pancreaticobiliary surgery is an infrequent but fatal complication. It is primarily caused by rupture of the pseudoaneurysm, and treatment options include endovascular coil embolization or endovascular stent-graft placement. Herein, we report a case of migration of an arterial stent-graft that was placed in the common hepatic artery to treat pseudoaneurysm after pylorus-preserving pancreaticoduodenectomy. The stent-graft migrated to the jejunum and was eventually excreted from the body.

Bilateral Vertebral Artery Dissecting Aneurysms Presenting with Subarachnoid Hemorrhage Treated by Staged Coil Trapping and Covered Stents Graft

  • Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Sung-Ho;Chang, Jae-Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.155-159
    • /
    • 2012
  • The treatment of bilateral vertebral artery dissecting aneurysms (VADAs) presenting with subarachnoid hemorrhage (SAH) is still challenging. The authors report a rare case of bilateral VADA treated with coil trapping of ruptured VADA and covered stents implantation after multiple unsuccessful stent assisted coiling of the contralateral unruptured VADA. A 44-year-old woman was admitted to our hospital because of severe headache and sudden stuporous consciousness. Brain CT showed thick SAH and intraventricular hemorrhage. Cerebral angiography demonstrated bilateral VADA. Based on the SAH pattern and aneurysm configurations, the right VADA was considered ruptured. This was trapped with endovascular coils without difficulty. One month later, the contralateral unruptured VADA was protected using a stent-within-a-stent technique, but marked enlargement of the left VADA was detected by 8-months follow-up angiography. Subsequently two times coil packing for pseudosacs resulted in near complete occlusion of left VADA. However, it continued to grow. Covered stents graft below the posterior inferior cerebellar artery (PICA) origin and a coronary stent implantation across the origin of the PICA resulted in near complete obliteration of the VADA. Covered stent graft can be used as a last therapeutic option for the management of VADA, which requires absolute preservation of VA flow.

Long-Term Clinical and Radiologic Outcomes after Stent-Graft Placement for the Treatment of Late-Onset Post-Pancreaticoduodenectomy Arterial Hemorrhage (췌십이지장절제술 후 발생한 후기 출혈에서 스텐트-그라프트를 이용한 치료의 장기적 임상, 영상의학적 결과)

  • Woo Jin Kim;Chang Ho Jeon;Hoon Kwon;Jin Hyeok Kim;Ung Bae Jeon;Suk Kim;Hyung Il Seo;Chang Won Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.600-612
    • /
    • 2021
  • Purpose To evaluate the long-term radiologic and clinical outcomes of stent-graft placement for the treatment of post-pancreaticoduodenectomy arterial hemorrhage (PPAH) based on the imaging findings of stent-graft patency and results of liver function tests. Materials and Methods We retrospectively reviewed the medical records of nine consecutive patients who underwent stent-graft placement for PPAH between June 2012 and May 2017. We analyzed the immediate technical and clinical outcomes and liver function test results. Stent-graft patency was evaluated using serial CT angiography images. Results All stent-grafts were deployed in the intended position for the immediate cessation of arterial hemorrhage and preservation of hepatic arterial blood flow. Technical success was achieved in all nine patients. Eight patients survived after discharge, and one patient died on postoperative day 28. The median follow-up duration was 781 days (range: 28-1766 days). Follow-up CT angiography revealed stent-graft occlusion in all patients. However, serum aspartate aminotransferase or alanine aminotransferase levels in all patients were well below those observed in hepatic infarction cases. Conclusion Stent-graft placement is a safe and effective treatment method for acute life-threatening PPAH. Liver function and distal hepatic arterial blood flow were maintained postoperatively despite the high incidence of stent-graft occlusion observed on follow-up CT.

Endovascular Repair in Acute Complicated Type B Aortic Dissection: 3-Year Results from the Valiant US Investigational Device Exemption Study

  • Lim, Chang Young
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • Acute complicated type B aortic dissection (TBAD) is a potentially catastrophic, life-threatening condition. If left untreated, there is a high risk of aortic rupture, irreversible organ or limb damage, or death. Several risk factors have been associated with acute complicated TBAD, including age and refractory hypertension. In the acute phase, even uncomplicated patients are more prone to develop complications if hypertension and pain are left medically untreated. Innovations in stent graft technologies have incrementally improved outcomes since their first use for this condition in 1999, though improvement is needed in mitigating periprocedural complications, adverse events, and mortality. In the past decade, endovascular repair has become the preferred treatment because of its superior outcomes to open repair and medical therapy. The Valiant Captivia Thoracic Stent Graft System is a third-generation endovascular stent graft with advancements in minimally invasive delivery, conformability to the anatomy, and the minimization of adverse sequelae. Herein, this stent graft is briefly reviewed and its 3-year outcomes are presented. Freedom from all-cause and dissection-related mortality was 79.1% and 90.0%, respectiv ely. The Valiant Captiv ia Stent Graft represents a safe, effective intervention for acute complicated TBAD. Continued surveillance is needed to verify its longer-term durability.

Endovascular Treatment Using Graft-Stent for Pseudoaneurysm of the Cavernous Internal Carotid Artery

  • Ko, Jun-Kyeung;Lee, Tae-Hong;Lee, Jae-Il;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.1
    • /
    • pp.48-50
    • /
    • 2011
  • A 57-year-old man presented with a 2-day history of left oculomotor palsy. Digital subtraction angiography revealed a pseudoaneurysm of the left cavernous internal carotid artery (ICA) measuring $37{\times}32mm$. The pseudoaneurysm was treated with a balloon expandable graft-stent to occlude the aneurysmal neck and preserve the parent artery. A post-procedure angiogram confirmed normal patency of the ICA and complete sealing of the aneurysmal neck with no opacification of the sac. After the procedure, the oculomotor palsy improved gradually, and had completely resolved 3 months after the procedure. A graft-stent can be an effective treatment for a pseudoaneurysm of the cavernous ICA with preservation of the parent artery.

Stent-graft Insertion in High Risk Patients with Aortic Dissection Including Intimal Tear of the Aortic Isthmus (대동맥 협부의 내막파열을 가진 고위험군 대동맥박리환자에서 시행한 스텐트 그라프트 삽입)

  • Do, Young-Woo;Kim, Gun-Jik;Cho, Joon-Young;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.424-427
    • /
    • 2010
  • Recently, stent-graft insertion has been widely used along with surgery for treatment of thoracic and abdominal aortic aneurysm. However, use of stent-graft insertion is controversial in descending aortic dissection. We report here on our experience of a patient who received a stent-graft for descending aortic dissection that nearly ruptured. Based on CT findings at three months follow up, results were satisfactory.

Endovascular Graft-Stent Placement for Treatment of Traumatic Carotid Cavernous Fistulas

  • Choi, Beom-Jin;Lee, Tae-Hong;Kim, Chang-Won;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.572-576
    • /
    • 2009
  • Detachable balloon-based endovascular fistula occlusion is a widely accepted treatment for traumatic carotid cavernous fistulas (CCF). However, more recently coils have been used to obliterate the lesion, especially in case detachable balloon is not available. We failed balloon-assisted coil embolization for CCF because of large fistulas and herniation of coil loops into the parent artery. The authors describe our experiences of balloon-expandable graft-stents to treat CCF, and place emphasis on arterial wall reconstruction. Three traumatic CCF patients were treated using a graft-stent with/without coils, and underwent angiographic follow-up to evaluate the patency of the internal carotid artery (ICA). In all cases, symptoms related to CCF regressed after stent deployment and did not recur during follow-up. Follow-up angiography revealed good patency of the ICA in all patients. Graft-stents should be considered as an alternative means of treating CCF and preserving the parent artery by arterial wall reconstruction especially in patients with a fistula that cannot be successfully occluded with detachable balloons or coils.

Mid-Term Results of Using the Seal Thoracic Stent Graft in Cases of Aortopathy: A Single-Institution Experience

  • Cho, Jun Woo;Jang, Jae Seok;Lee, Chul Ho;Hwang, Sun Hyun
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.335-341
    • /
    • 2019
  • Background: The endovascular approach to aortic disease treatment has been increasingly utilized in the past 2 decades. This study aimed to determine the long-term results of using the Seal thoracic stent graft. Methods: We retrospectively reviewed the outcomes of patients who underwent thoracic endovascular aortic repair or a hybrid procedure using the Seal thoracic stent graft (S&G Biotech, Seongnam, Korea) from January 2008 to July 2018 at a single institution. We investigated in-hospital mortality and the incidence of postoperative complications. We also investigated the mid-term survival rate and incidence of aorta-related complications. Results: Among 72 patients with stent grafts, 15 patients underwent the hybrid procedure and 21 underwent emergency surgery. The mean follow-up period was $37.86{\pm}30.73$ months (range, 0-124 months). Five patients (6.9%) died within 30 days. Two patients developed cerebrovascular accidents. Spinal cord injury occurred in 2 patients. Postoperative renal failure, postoperative extracorporeal membrane oxygenation support, and pneumonia were reported in 3, 1, and 6 patients, respectively. Stent-related aortic complications were observed in 5 patients (6.8%). The 1- and 5-year survival and freedom from stent-induced aortic event rates were 81.5% and 58.7%, and 97.0% and 89.1%, respectively. Conclusion: The use of the Seal thoracic stent graft yielded good mid-term results. Further studies are needed to examine the long-term outcomes of this device.