• Title/Summary/Keyword: Gradients

Search Result 1,176, Processing Time 0.032 seconds

MR Technology to 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF

Forensic Decision of Median Filtering by Pixel Value's Gradients of Digital Image (디지털 영상의 픽셀값 경사도에 의한 미디언 필터링 포렌식 판정)

  • RHEE, Kang Hyeon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.6
    • /
    • pp.79-84
    • /
    • 2015
  • In a distribution of digital image, there is a serious problem that is a distribution of the altered image by a forger. For the problem solution, this paper proposes a median filtering (MF) image forensic decision algorithm using a feature vector according to the pixel value's gradients. In the proposed algorithm, AR (Autoregressive) coefficients are computed from pixel value' gradients of original image then 1th~6th order coefficients to be six feature vector. And the reconstructed image is produced by the solution of Poisson's equation with the gradients. From the difference image between original and its reconstructed image, four feature vector (Average value, Max. value and the coordinate i,j of Max. value) is extracted. Subsequently, Two kinds of the feature vector combined to 10 Dim. feature vector that is used in the learning of a SVM (Support Vector Machine) classification for MF (Median Filtering) detector of the altered image. On the proposed algorithm of the median filtering detection, compare to MFR (Median Filter Residual) scheme that had the same 10 Dim. feature vectors, the performance is excellent at Unaltered, Averaging filtering ($3{\times}3$) and JPEG (QF=90) images, and less at Gaussian filtering ($3{\times}3$) image. However, in the measured performances of all items, AUC (Area Under Curve) by the sensitivity and 1-specificity is approached to 1. Thus, it is confirmed that the grade evaluation of the proposed algorithm is 'Excellent (A)'.

Analysis of Temperature Gradients in Greenhouse Equipped with Fan and Pad System by CFD Method (CFD 기법을 이용한 팬 앤 패드 냉방 온실의 온도경사 분석)

  • Nam Sang Woon;Giacomelli Gene A.;Kim Kee Sung;Sabeh Nadia
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • Evaporative cooling pad system is one of the main cooling methods in greenhouses and its efficiency is very high. However, it has some disadvantages such as greenhouse temperature distributions are not uniform and installation cost is expensive. In this study, a CFD simulation model f3r predicting the air temperature distribution in the fan and fad cooling greenhouse was developed. The model was calibrated and validated against experimental data and a good fit was obtained. The influence of different outside wind, fan and pad height, ventilation rate, shading, and greenhouse length, were then examined. In order to reduce the internal temperature gradients, it is desired that the prevail wind direction and the fan and pad heights are considered. The simulation indicates that high ventilation rates and shading contribute to reduce the temperature gradients in the fan and pad cooling greenhouse. In order to maintain the desired greenhouse temperature, the pad-to-fan distance should be restricted according to the design climate conditions, shading and ventilation rates. The developed CFD model can be a useful tool to evaluate and design the fan and pad systems in the greenhouses with various configurations.

Effect of Moisture and Nutrient of Soil on Reproductive Phenology and Physiological Response of Epilobium hirsutum L., an Endangered Plant (토양의 수분과 유기물이 멸종위기식물 큰바늘꽃(Epilobium hirsutum L.)의 번식계절 및 생리 반응에 미치는 영향)

  • Lee, EungPill;Lee, SooIn;Han, YoungSub;Lee, SeungYeon;You, YoungHan;Cho, YiYun
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2018
  • Reproductive phenology and physiological responses of Epilobium hirsutum L. to moisture content and nutrient content of soil were analysed in order to obtain basic data for effective conservation and restoration. Epilobium hirsutum L. is a perennial plant. But Epilobium hirsutum L. grew reproductively in all moisture and nutrient gradients. Flower bud, flowers and peduncle were respectively ripened in earlier under highest moisture condition and highest nutrient condition. And, number of flowers and peduncle were more quickly increased under highest moisture condition and highest nutrient condition. Chlorophyll content was high under highest moisture condition and higher middle moisture condition. However, we found no significant difference of chlorophyll content regard to nutrient gradients. There was no difference in minimum chlorophyll fluorescence among all moisture and nutrient gradients. The photochemical efficiency values of PS II were 0.75 in all moisture gradients, and it was 0.78 in highest nutrient gradient. The chlorophyll content of Epilobium hirsutum L. increased as the moisture content increased, and the Fv/Fm value increased as the organic matter increased. Our results showed that high moisture and nutrient content of soil advance their breeding season and promote reproductive growth. It might be important basic informations for the maintenance of population and the management of habitat of Epilobium hirsutum L. an endangered plant species.

AN EXTENDED THEOREM FOR GRADIENTS AND SUBGRADIENTS

  • Rhee, Hyang Joo
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.24 no.2
    • /
    • pp.351-357
    • /
    • 2011
  • In this paper, we introduce certain concepts which we will provide us with a perspective and insight into the problem of calculating best approximations. The material of this paper will be mainly, but not only, used in developing algorithms for the one-sided and two-sided sided approximation problem.

Judging spinal deformity by two characteristic axes on a human back

  • Ishikawa, Seiji;Eguchi, Takemi;Yamaguchi, Toshihiko;Ki, Hyoung-Seop;Otsuka, Yoshinori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.438-441
    • /
    • 1996
  • Spinal deformity is a serious disease especially for teenagers and it is desirable for school children to be checked possible spinal deformity by moire photographic inspection method. The moire images of children's backs are visually inspected by doctors, which may cause misjudge because of a large amount of data they have to examine. A technique is proposed in this paper for automating this inspection by computer. Two characteristic axes, a potential symmetry axis approximating the human middle line and a principal axis representing the direction of a moire pattern are employed. Two principal axes are extracted locally on a back and their gradients against the potential symmetry axis are calculated. These gradients compose a 2D feature space and a linear discriminant function (LDF) is defined there which separates normal cases from suspicious cases. The LDF defined by 40 training, data was employed in the experiment to examine 40 test data and 77.5% of them were classified correctly. This amounts to 88.8% if the training data is included.

  • PDF