• Title/Summary/Keyword: Gradients

Search Result 1,176, Processing Time 0.03 seconds

The Characteristics of Fishing Ground in the Adjacent Sea of Naro Island (2) - Seasonal Variation of Watermass - (나로도 주변해역의 어장학적 특성 (2) -수괴의계절변화 -)

  • 김동수;주찬순;박주삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.1
    • /
    • pp.19-26
    • /
    • 2003
  • In order to investigate the seasonal variation of watermass in the adjacent sea of Naro Island, oceanographic observation on the fishing grounds were carried out by the training vessel of Yosu National University on winter, spring, summer, and autumn in 2000. The results obtained are summarized as follows ; 1) the watermass in the fishing ground were divided into the coastal water (30.0∼31.4psu), mixing water (31.5∼32.9psu) and the offshore water (33.0∼35.0psu) according to the distribution of salinity from T-S diagram plotted all salinity data observed on winter, spring, summer, and autumn in 2000. 2) the ranges of temperature and salinity were from 4.$3\circ_C$ to 10.1$^{\circ}C$ and from 33.1psu to 34.9psu in winter, from 8.$1\circ_C$ to 13.$7\circ_C$ and from 33.1psu to 34.3psu in spring, from 14.5$^{\circ}C$ to 24.$2\circ_C$ and from 30.5psu to 34.1psu in summer, and from 14.$5\circ_C$ to 18.$6\circ_C$ and from 30.1psu to 34.0psu in autumn, respectively. 3) the distribution of watermass in the fishing ground varied largely each seasons, but a general tendency on the distribution was obtained. That is, in winter and spring the offshore water was distributed most widely and in summer the coastal and mixing water occupied the fishing ground but in autumn the mixing water prevailed. 4) variation of temperature and salinity were appeared between the surface and 20m layer in the sea aduacent to Naro Island. Therefore, in the summer the thermocline were made between surface and 20m layer with vertical gradients of 4.$0\circ_C$/7m.

Spatial Distribution of Macrozoobenthos Along the Salinity Gradient and Sedimentary Environment in the Watancheon Estuary, Beobseongpo, Southwest Coast of Korea (법성포 와탄천 하구역의 염분과 퇴적환경에 따른 대형저서동물의 공간분포)

  • Hong, Jae-Sang;Lim, Hyun-Sig
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.7 no.1
    • /
    • pp.8-19
    • /
    • 2002
  • Spatial distribution pattern of macrozoobenthos was studied along the salinity gradient and sedimentary environment in the Watancheon estuary, Beobseongpo, southwest coast of Korea. Ten stations were set from the mouth towards the head of estuary. Three replicate sediment samples were taken using a van Veen grab (surface area $0.1m^{2}$) at each station between June 1998 and January 1999. A total of 114 species were collected during the study period and they are composed of 44 species of polychaetes (39%), 34 of crustaceans (30%), 24 of molluscs (21%) and 12 of miscellaneous. The former two taxa together accounted for 69% in the total number of species. The mean density was 3,053 ind./m$^{2}$, comprising 2,536 ind./m$^{2}$ from polychaetes (83%) and 439 ind./m$^{2}$, crustaceans (14%). Moreover, the mean biomass was 58.23 gwwt./m$^{2}$, consisting of 29.56 gwwt./m$^{2}$ from polychaetes (51%), 23.38 gwwt./m$^{2}$, molluscs (40%). A spionid polychaete Minuspio japonica, two corophiid amphipods Grandidierella japonica and Corophium sinense, a bivalve Potamocorbula amurensis were major dominants at the head of estuary where the salinity was relatively lower compared with contiguous sites. The distributions of M. japonica and G. japonica were significantly related to the salinity and sediment environment, respectively, whereas C. sinense and P, amurensis showed no significance. The nereid polychaete, Hediste japonica, also predominated at the head of the estuary where bottom salinity was relatively low. Species diversity was high at the mouth area whereas low diversity and few species number were seen at the stations in the head of the estuary, influenced by freshwater and sandy sediment. Based on the cluster analysis, the macrobenthic community was classified into four station groups from head (station group A) toward mouth (group D) in the study area. The number of species and abundance between station group B and C were significantly different. And the abundance of between two neighboring station groups (station group A and B, B and C, C and D) was also different. These results suggested that the spatial distribution pattern of macrobenthos in this estuary seemed mainly related to gradients in bottom salinity and sediment grain size among environmental factors.

Small Aortic Annulus in Aortic Valve Replacement; Comparison between Aortic Annular Enlargement Group and Patient-prosthesis Mismatch Group (협소한 대동맥판륜 환자에서의 대동맥판막 치환술; 대동맥판륜 확장술군과 환자-인공판막 부조화군의 비교)

  • Kim, Jae-Hyun;Oh, Sam-Sae;Yie, Kil-Soo;Shin, Sung-Ho;Baek, Man-Jong;Na, Chan-Young
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.200-208
    • /
    • 2007
  • Background: The effect of patient-prosthesis mismatch (PPM) on the clinical outcome following aortic valve replacement (AVR) remains controversial. This study compared the surgical outcomes of AVR between patients with a patient-prosthesis mismatch and those having undergone an aortic annular enlargement. Material and Method: Six hundred and twenty seven adult patients, who underwent AVR with stented bioprosthetic or mechanical valves, between January 1996 and February 2006, were evaluated. PPM was defined as an indexed effective orifice area (iEOA) ${\leq}0.85cm^2/m^2$, and Severe if the iEOA${\leq}0.65cm^2/m^2$ PPM was present in 103 (16.4%, PPM group) patients, and severe in 11 (1.8%, SPPM group). During the period of the study, 21 patients underwent an AVR with annular enlargement (AE group). Result: The mean iEOA of the AE group was larger than that of the PPM group ($0.95\;vs.\;0.76cm^2/m^2,\;p=0.00$). The AE group had longer CPB, ACC and operation times than the PPM group, and showed a tendency toward higher operative mortality (14.3% vs. 2.9%, p=0.06). The SPPM group had higher AV pressure gradients (peak/mean) than the AE group (72/45 mmHg vs. 38/25 mmHg, p=0.02/0.06) and suffered more AV related events (AV reoperation or severe aortic stenosis)(45.5% vs. 9.5%, p=0.03). LV masses were not regressed in the patients who experienced an AV related event. Conclusion: During AVR in patients with a small aortic annulus, annular enlargement should be carefully applied taking into account the high risk of operative mortality due to annular enlargement and co-morbidities of patients. Aortic annular enlargement; however, should be considered as an alternative method in patients expected to have a severe PPM after an AVR.

Complex Terrain and Ecological Heterogeneity (TERRECO): Evaluating Ecosystem Services in Production Versus water Quantity/quality in Mountainous Landscapes (산지복잡지형과 생태적 비균질성: 산지경관의 생산성과 수자원/수질에 관한 생태계 서비스 평가)

  • Kang, Sin-Kyu;Tenhunen, John
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.307-316
    • /
    • 2010
  • Complex terrain refers to irregular surface properties of the earth that influence gradients in climate, lateral transfer of materials, landscape distribution in soils properties, habitat selection of organisms, and via human preferences, the patterning in development of land use. Complex terrain of mountainous areas represents ca. 20% of the Earth's terrestrial surface; and such regions provide fresh water to at least half of humankind. Most major river systems originate in such terrain, and their resources are often associated with socio-economic competition and political disputes. The goals of the TERRECO-IRTG focus on building a bridge between ecosystem understanding in complex terrain and spatial assessments of ecosystem performance with respect to derived ecosystem services. More specifically, a coordinated assessment framework will be developed from landscape to regional scale applications to quantify trade-offs and will be applied to determine how shifts in climate and land use in complex terrain influence naturally derived ecosystem services. Within the scope of TERRECO, the abiotic and biotic studies of water yield and quality, production and biodiversity, soil processing of materials and trace gas emissions in complex terrain are merged. There is a need to quantitatively understand 1) the ecosystem services derived in regions of complex terrain, 2) the process regulation occurred to maintain those services, and 3) the sensitivities defining thresholds critical in stability of these systems. The TERRECO-IRTG is dedicated to joint study of ecosystems in complex terrain from landscape to regional scales. Our objectives are to reveal the spatial patterns in driving variables of essential ecosystem processes involved in ecosystem services of complex terrain region and hence, to evaluate the resulting ecosystem services, and further to provide new tools for understanding and managing such areas.

Effects of NaCl Concentration on the Rancidity Development of Sample Ramyon Products, Deep-Fried Instant Noodles (라면 시제품(試製品)의 산패(酸敗)에 미치는 소금 농도(濃度)의 영향(影響))

  • Kim, Tae-Woong;Heo, Tae-Ryeon;Kim, Dong-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.51-56
    • /
    • 1975
  • The effects of various concentration of NaCI, i.e., 1, 2, 2. 5, 3, and 4%, on the rancidity development of samples of Ramyon, deep-fried instant noodles, were studied. Dough for the samples, which was composed of wheat flour, distilled water, and pure NaCI, was prepared at a commercial plant but the deep-frying p개cess for the dough was performed in the laboratory. The products thus obtained were incubated for 50 days at $45.0{\pm}1.0^{\circ}C$. Peroxide and TBA values were determined every 5 days throughout the storage period. The results obtained are as follows. 1) Control and the samples containing 1, 2, 2. 5, and 3% salt had POVs of 8. 7, 9. 1, 9. 0, 9. 2 and 9. 7 respectively after 25 days. The control showed a POV of 19.1 after 45 days whereas the sample Ramyons containing 1, 2, 2. 5, 3, and 4% salt had POVs of 12. 6, 13. 2, 14. 6, 15. 3, and 15. 8 respectively after 30 days. 2) TBA values of Control and the sample containing 1, 2, 2. 5, 3, and 4% salt were 5. 8, 6. 1, 6. 2, 6. 4, 6. 7, and 6. 6 respectively after 15 days. But the control developed a TBA value of 11. 4 after 40 days. The samples containing 1, 2, 2. 5, and 3% salt showed TBA values of 10. 2, 14. 3, 15. 8, and 15. 3 respectively after 30 days whereas the sample containing 4% salt had a TBA value of 13. 8 after 25 days. 3) The relationship between the POVs and the TBA values was linear. However, the regression curves of the POVs and the TBA values indicated progressive increase in the gradients(POV/TBA) with increase in the salt content. 4) From the results of the present study, it was found that although the acceleration of rancidity was not in proportion to the amount of NaCI, definite progressive increase in the rancidity development was observed with increase in the salt content of the sample Ramyons.

  • PDF

Distribution Characteristics and Dynamics of the Lindera sericea Population at Mt. Mudeung, Mt. Cheonbong and Mt. Chogye (무등산, 천봉산 및 조계산에서 털조장나무 개체군의 분포특성과 동태)

  • Lim, Dong-ok;Choi, Dea-hun;Yun, Hong-gyun
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.4
    • /
    • pp.570-579
    • /
    • 2015
  • Lindera sericea, which belongs to genus Lindera in the Lauraceae family, is labeled under Least Concerned (LC) among Korean rare plants, floristics specific species IV grade and also flagpole species of the Mudeung National Park. It is distributed in Mt. Mudeung, Mt. Cheonbong and Mt. Chogye within gradients from $12^{\circ}$ to $51^{\circ}$. The slope area is from northeast to northwest sides and the altitude range of distribution site is between 220 m and 533 m. The vascular plants in the quadrate where Lindera sericea were studied were identified as a total of 72 taxa; 37 families, 54 genera, 66 species, 5 variants and 1 forma. Among the floristics specific species, IV grade species was Lindera sericea and III grade species were Stewartia pseudocamellia and Acer palmatum. Korean endemic species were Stewartia pseudocamellia and Carex okamotoi. As for the vegetation group, Quercus mongolica and Q. serratak - Lindera sericea, Styrax japonicus populations were found in Mt. Mudeung area where Lindera sericea appeared, Stewartia pseudocamellia-Lindera sericea and Sasa borealis populations were found in Mt. Cheonbong areas, Carpinus laxiflora - Lindera sericea and Sasa borealis populations were found in Mt. Chogye area, and Stewartia pseudocamellia-Lindera sericea and Sasa borealis populations were found in Songgwangsa area. A total number of 662 Lindera sericea individuals were examined. The number of trees with 1 trunk including younger individuals was 353 (53.32%), and the number of trees with 2 to 5 stems was 270 (40.79%). The number of trees with the greatest number of sprouts was 27. Of 662 trees in total, the total number of sprouts was 1,198. Among these, 699 trees (58.34%) were between 50 cm and 150 cm in height. The tallest tree was 585 cm. The most common root-collar diameter of sprouts (992, 82.81%) was under 1 cm, followed by the sprouts with collar diameter from 1.0 to 1.5 cm(156, 13.2%). Among them, the largest root-collar diameter was 3.2 cm. This Lindera sericea specimen had the tallest trunk (565 cm) which was torn lengthwise on one side. Its root and breast parts were decayed by 50% and 25 respectively. Some branches of the three trunks that were more than 4 m in length were dead in the apical portion. Therefore, it is proposed that the Korean Lindera sericea maintains an apical dominance tree type while showing morphological adaptation as a typical shrub because it autonomously decays some branches and trunks over a certain height while increasing the number of its sprouts.

Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films (사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름)

  • Jang Ji-Sun;Shin Dong-Oh;Choi Byung-Ock;Lee Tae-Kyu;Choi Ihl-Bohng;Kim Moon-Chan;Kwon Soo-Il;Kang Young-Nam
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • The accuracy of the dosimetry in the Cyberknife system is accomplishing important role from all processes of the stereotactic radiosurgery. In this study, we estimated relative output factors for Cyberknife. All measurements were peformed by six different detectors: diode detector, X-Omat V film, Gafchromic EBT film, 0.015 cc, 0.125 cc and 0.6 cc ionization chamber The diode detector and three ionization chambers peformed using water phantom at 80 cm SSD and 1.5 cm depth. When the film measurements were peformed, the water phantom was replaced with a solidwater phantom. Each collimator normalized with respect to the output factor of the largest collimator (60 mm). For the collimators over than 30 mm, the output factors from the different detectors showed a good agreement within 0.5% except 0.6 cc ion chamber For the collimators less than 15 mm, there were substantial differences In the output factors among different detectors. That is, the value of output factor for the 5 mm collimator of a diode and Gafchromic film was each $0.656{\pm}0.009$ and $0.777{\pm}0.013$. In the ion chamber and diode detector, those difference were due to the presence of large dose gradients and lack of electronic equilibrium in narrow megavoltage x-ray beams Therefore, the Gafchromic EBT film were considered more accurate than the others detectors.

  • PDF

Feasibility Study of the microDiamond Detector for Measurement of Small Field Photon Beam (광자선 소조사면 선량측정을 위한 microDiamond 검출기의 유용성 고찰)

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Ji, Young Hoon;Kim, Kum Bae;Lee, Sang Hoon;Min, Chul Kee;Jo, Gwang Hwan;Shin, Dong Oh;Kim, Seong Hoon;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.255-263
    • /
    • 2014
  • The dosimetry of very small fields is challenging for several reasons including a lack of lateral electronic equilibrium, large dose gradients, and the size of detector in respect to the field size. The objective of this work was to evaluate the suitability of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the small field dosimetry in cyberknife photon beams of 6 different collimator size (from 5 mm to 30 mm). Measurements included dose linearity, dose rate dependence, output factors (OF), percentage depth doses (PDD) and off center ratio (OCR). The results were compared to those of pinpoint ionization chamber, diamond detector, microLion liquid Ionization chamber and diode detector. The dose linearity results for the microDiamond detector showed good linearly proportional to dose. The microDiamond detector showed little dose rate dependency throughout the range of 100~600 MU/min, while microLion liquid Ionization chamber showed a significant discrepancy of approximately 5.8%. The OF measured with microDiamond detector agreed within 3.8% with those measured with diode. PDD curves measured with silicon diode and diamond detector agreed well for all the field sizes. In particular, slightly sharper penumbras are obtained by the microDiamond detector, indicating a good spatial resolution. The results obtained confirm that the new PTW 60019 microDiamond detector is suitable candidate for application in small radiation fields dosimetry.

Dosimetric Verifications of the Output Factors in the Small Field Less Than $3cm^2$ Using the Gafchromic EBT2 Films and the Various Detectors (Gafchromic EBT2필름과 다양한 검출기를 이용하여 $3cm^2$ 이하의 소조사면에서 출력비율의 선량검증)

  • Oh, Se An;Yea, Ji Woon;Lee, Rena;Park, Heon Bo;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.218-224
    • /
    • 2014
  • The small field dosimetry is very important in modern radiotherapy because it has been frequently used to treat the tumor with high dose hypo-fractionated radiotherapy or high dose single fraction stereotactic radiosurgery (SRS) with small size target. But, the dosimetry of a small field (< $3{\times}3cm^2$) has been great challenges in radiotherapy. Small field dosimetry is difficult because of (a) a lack of lateral electronic equilibrium, (b) steep dose gradients, and (c) partial blocking of the source. The objectives of this study were to measure and verify with the various detectors the output factors in a small field (<3 cm) for the 6 MV photon beams. Output factors were measured using the CC13, CC01, EDGE detector, thermoluminescence dosimeters (TLDs), and Gafchromic EBT2 films at the sizes of field such as $0.5{\times}0.5$, $1{\times}1$, $2{\times}2$, $3{\times}3$, $5{\times}5$, and $10{\times}10cm^2$. The differences in the output factors with the various detectors increased with decreasing field size. Our study demonstrates that the dosimetry for a small photon beam (< $3{\times}3cm^2$) should use CC01 or EDGE detectors with a small active volume. And also, Output factors with the EDGE detectors in a small field (< $3{\times}3cm^2$) coincided well with the Gafchromic EBT2 films.

Diffusion-Weighted MR Imaging of Various Intracranial Diseases : Clinical Utility (다양한 두개강내 질환의 확산강조 자기공명영상 : 임상적 유용성)

  • 김영준
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.104-112
    • /
    • 1998
  • Purpose : To evaluate the clinical utility of diffusion-weighted imaging by analyzing the signal intersity of lesions in patients with various intracranial diseases. Materials and Methods : difusion-weighted MR imaging was prospectively perormed in randomly selected 70 patients with various intracranial idseases. They consisted of 20 patients with acute infarct, 21 patients with chronic infarct of small vessel disease, 14 patients with primary intracranial tumor, three patients with brain metastasis, five patient with brain abscess, five patients with brain abscess, five patients with cerebral hemorrhage, one patient with neurocysticercosis, and one patient with epidermoid cyst. the diffusion-weighted images were obtained immediately after routine T2-weighted imaging on a 1.5T MR unit using single shot spin echo EPI technique with 6500 ms TR, 107ms TE, $128{\times}128$ matrix, 1 number of excitation, $24{\times}24$ field of view, 5-7 mm slice thickness, 2-3 mm inter-slice gap. The diffusion-gradients (b value of ($1000s{\;}/{\;}textrm{mm}^2$)) were applied along three directions(x, y, z). On visual inspection of diffusion-weighted images, the signal intersity of lesions was arbitrarily graded as one of 5 grades. In quantitative assessment, we measured the signal intensity of all the lesions and the contralateral corresponding normal area using round region of interest(ROI), and then calculated the signal intensity ratio of the lesion to the normal brain parenchyma. Results : On visual inspection, markedly hyperintense signals were seen in all cases of acute infarct, brain abscess, epidermoid cyst, and neurocysticercosis in degenerating stage. In all cases of cerebral hematoma, the very high signal internsity was intermingled with low signal intensity. focal very high signal intersity was also seen in a solid portion of the tumor in a patient. the mean signal intensity ratios of all those lesions to the normal brain parenchyma were above 2.5. Gliosis, solid component of brain tumor, brain metastasis, and vasogenic dedma appeared isointense to the normal brain parenchyma in 71%, 64%, 100%, and 67%, respectively ; the mean signal intensity ratios of those lesions to the normal brain parenchyma ranged 1.15 to 1.28 and there was no significant difference among these(p>0.1). Cystic cerebromalacia and necrotic or cystic portions in tumor were markedly or slightly hypointense, and the mean signal intensity ratios were 0.45 and 0.42, respectively. Conclusion : Very high signal intensity of acute infarct, brain abscess, epidermoid cyst, and cystic neurocysticercosis in degenerating stage on diffusion-weighted images may be helpful in differentiating from other diseases that are hypointense or isointense to the normal brain parenchyma. It may be especially useful differentiation of brain abscess from brain tumor with necrotic or cystic portion.

  • PDF