The assessment of tumoral necrosis in rat tumor model using dynamic T1/T2* gradient dual echo sequence with Gd-DTPA and Gadomer-17 as a MR contrast agent

  • 허용민;김대홍;김은주;송호택;서진석;이상훈
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.93-93
    • /
    • 2003
  • To test the feasibility of rBF and rBVin the assessment of R004 sarcomas of the rat and to compare the results obtained by using Gd-DTPA and Gadomer-17 as a MR contrast agent, on the basis of the histological findings of tumor necrosis.

  • PDF

Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system (고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구)

  • Kim, D.H.;Ko, R.K.;Kang, B.M.;Ha, D.W.;Sohn, M.H.;Mun, C.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

A fMRI study on the cerebral activity induced by Electro-acupuncture on Sp9(Yinlingquan) (음릉천(陰陵泉)(Sp9)의 전침자극(電鍼刺戟)이 functional MRI상 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響))

  • Kim, Jeong-ho;Lee, Hyun;Lim, Yun-kyoung;Hong, Kwon-eui;Lee, Byung-ryul;Kim, Yeon-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.4
    • /
    • pp.114-133
    • /
    • 2003
  • Objective : The meridian theory in oriental medicine explains that Sp9(Yinlingquan) has been considered very important for gynecological disorders, spleen and stomach disorders, and water metabolic disorders. Functional MRI is the best method of showing the evidences of the effect of the Electro-acupuncture treatment through scientific methods. On this supposition, Electro-acupuncture stimulation on Sp9(Yinlingquan) was carried out on six healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). Methods : Electro-acupuncture stimulation on Sp9(Yinlingquan), the experiment was carried out on six healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). After the needle insertion on right Sp9(Yinlingquan), 2Hz of electric stimulation was given for 30 seconds, repeated five times, with 30 seconds' intervals. The Image analysis including motion correction, talairach transformation, and smoothing was done using SPM99. Results : The electro-acupuncture stimulation on Sp9(Yinlingquan) activates Brodmann Area 13, 19, 22, 39, 40, 47 which may be the central pathways of the electro-acupuncture stimulation on Sp9(Yinlingquan). We also hypothesize that those brain areas may be directly or indirectly related with the mechanism of the effect of electro-acupuncture stimulation on Sp9(Yinlingquan).

  • PDF

A Study of brain Atlases in Hippocampus Volume Measurement Using IBASPM (IBASPM을 이용한 해마체적 측정에서 뇌 Atlases에 대한 고찰)

  • Kim, Ju-ho;Lee, Ju-won;Kim, Seong-hu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.981-984
    • /
    • 2014
  • Volumetric measurement of hippocampus using IBASPM, the 20's normal adults 10 people's brain images were acquired in order to assess the changes according to the type of the Atlas. Images was obtained using MPRAGE of a 3-D gradient echo pulse sequence on Head matrix coil of 1.5T MRI system. The results of Paired t-test using obtained volume of hippocampus depending on the type of the Atlas, Atlas69-Altas84, Atlas69-Atlas116(p=0.729, 0.729) in the left hippocampus and Atlas69-Atlas84, Atlas69-Atlas116(p=0.219, 0.219) in right hippocampal formation were no significant differences but in the area except this, there was significant difference(p=0.000). The volume of the hippocampus using Atlas84 and Atlas116, represented the same value and there was no significant difference. In the image analysis using the overlay of atlas image and original image, Atlas71 could be found that the area of hippocampus did mismatch. In the case of atlas used in this study, because it has been developed by the westerners, there are differences between brain of asian. It would be needed to development of new Atlas for high accuracy measurement of the volume of hippocampus.

  • PDF

Hyperacute Intracerebral Hemorrhage : Comparison of EPI and Other MR Sequence (두 개내 초급성 출혈 : EPI와 다른 MR 영상 기법의 비교)

  • 김정희;김옥화;서정호;박용성
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.167-172
    • /
    • 1999
  • Purpose : To evaluate the detection rate of hyperacute intracerebral hemorrhage in echo planar imaging (EPI) and other MR sequences. materials and Methods : Intracerebral hemorrhage was experimentally induced in ten rats. EPI, fast spin-echo (FSE) T2 weighted images, fluid attenuated inversion recovery (FLAIR), spin-echo (SE) T1 weighted images and gradient echo (GE) T1 weight ed images of rat's brains were obtained 2 hours after onset of intracerebral hemorrhage. EPI and FSE T2 images were additionally obtained 30 min and 1 hour after onset of hemorrhage in 3 and 6 rat, repeatedly, For objective visual assessment, discrimination between the lesion and normal brain parenchyma was evaluated on various MR sequences by three radiologists. For quantitative assessment, contrast-to-noise ratio (CNR) was calculated fro hemorrhage-normal brain parenchyma. Statistical analysis was performed usning the Wilcoxon-Ranks test. Results : EPI, FLAIR, and FSE T2 images showed high signal intensity lesions. The lesion discrimination was easier on EPI than on other sequences, and also EPI showed higher signal intensity for the subjective visual assessment. In quantitative evaluation, CNR of the hemorrhagic lesion versus normal brain parenchyma were higher on EPI and FLAIR images (p<0.01). There was no difference in CNR between EPI and FLAIR (p>0.10). On MR images obtained 30 minutes and 1 hour after the onset of intracerebral hemorrhage, the lesion detection was feasible on both EPI and FSE T2 images showing high signal intensity. Conclusion : EPI showed higher detection rate as compared with other MR sequences and could be useful in early detection and evaluation of intracerebral hemorrhage.

  • PDF

Isolated Cortical Vein Thrombosis with Long Cord Sign

  • Ban, Seung Pil;Chung, Young Seob;Park, Sung Bae;Son, Young-Je
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.5
    • /
    • pp.476-478
    • /
    • 2015
  • Isolated cortical vein thrombosis (ICVT) is a rare disease, accounting for less than 1% of strokes. A 46-year-old woman presented with progressive left side weakness. Magnetic resonance (MR) imaging with $T2^*$-gradient echo ($T2^*$-GE) sequence showed long cord sign at the right frontal cortex. The patient was treated with low molecular weight heparin, followed by oral warfarin for 6 months. The 3-month follow-up MR imaging showed recanalization of the previously thrombosed cortical vein. She was completely recovered without neurological deficits after 6 months. This provides that MR imaging with $T2^*$-GE sequence can help to diagnosis the ICVT and outcomes of the ICVT are generally favorable.

Reduction of Susceptibility Effect Using Frequency Modulation DANTE (주파수 변조 DANTE를 이용한 자화율 효과의 감소)

  • Chung, S.T.;Hong, I.K.;Kim, J.H.;Ro, Y.M.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.167-170
    • /
    • 1995
  • An frequency modulated (FM) DANTE pulse sequence generates a quadratic phase toward the transverse of image by an FM RF pulse. In the image of a serious susceptibility effect, the phase due to the difference of the susceptibility in the pixel occurs susceptibility error which arise signal loss. But the signal loss due to the susceptibility effect in the pixel is reduced when the quadratic phase adds in the pixel. In this paper, we have generated a quadratic function toward the transverse (X-Y) using FM DANTE sequence and the susceptibility effect is reduced in the gradient echo (GE) imaging. Computer simulation and experimental results is obtained by using a whole-body KAIS 2.0T NMR system.

  • PDF

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

Radiofrequency Coil Design for in vivo Sodium Magnetic Resonance Imaging of Mouse Kidney at 9.4T

  • Lim, Song-I;Woo, Chul-Woong;Kim, Sang-Tae;Choe, Bo-Young;Woo, Dong-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.65-70
    • /
    • 2018
  • The objective of this study was to describe a radiofrequency (RF) coil design for in vivo sodium magnetic resonance imaging (MRI) for use in small animals. Accumulating evidence has indicated the importance and potential of sodium imaging with improved magnet strength (> 7T), faster gradient, better hardware, multi-nucleus imaging methods, and optimal coil design for patient and animal studies. Thus, we developed a saddle-shaped sodium volume coil with a diameter/length of 30/30 mm. To evaluate the efficiency of this coil, bench-level measurement was performed. Unloaded Q value, loaded Q value, and ratio of these two values were estimated to be 352.8, 211.18, and 1.67, respectively. Thereafter, in vivo acquisition of sodium images was performed using normal mice (12 weeks old; n = 5) with a two-dimensional gradient echo sequence and minimized echo time to increase spatial resolution of images. Sodium signal-to-noise ratio in mouse kidneys (renal cortex, medulla, and pelvis) was measured. We successfully acquired sodium MR images of the mouse kidney with high spatial resolution (approximately 0.625 mm) through a combination of sodium-proton coils.

Association of Carotid Intraplaque Hemorrhage and Territorial Acute Infarction in Patients with Acute Neurological Symptoms Using Carotid Magnetization-Prepared Rapid Acquisition with Gradient-Echo

  • Park, Jung Soo;Kwak, Hyo Sung;Lee, Jong Myong;Koh, Eun Jeong;Chung, Gyung Ho;Hwang, Seung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.94-99
    • /
    • 2015
  • Objective : The purpose of our study was to assess prevalence of carotid intraplaque hemorrhage (IPH) and associations between territorial acute infarction and IPH on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) in patients with acute neurologic symptoms. Methods : 83 patients with suspected acute neurologic symptoms were evaluated with both brain diffusion weighted imaging (DWI) and carotid MPRAGE sequences. Carotid plaque with high signal intensity on MPRAGE of >200% that of adjacent muscle was categorized as IPH. We analyzed the prevalence of IPH and its correlation with territorial acute infarction. Results : Of 166 arteries, 39 had a carotid artery plaque. Of these arteries, 26 had carotid artery stenosis less than 50%. In all carotid arteries, MR-depicted IPH was found in 7.2% (12/166). High-signal intensity on DWI was found in 17.5% (29/166). Combined lesion with ipsilateral high-signal intensity on DWI and IPH on carotid MPRAGE sequence was found in 6 lesions (6/166, 3.6%). Of patients with carotid artery plaque, MR-predicted IPH was found in 30.8% (12/39) and match lesions with high-signal intensity on DWI and MPRAGE was found in 15.4% (6/39). MR-predicted IPH was significantly higher prevalence in high-grade stenosis group (p=0.010). Relative risk between carotid MPRAGE-positive signal and ipsilateral high-signal intensity on DWI in arteries with carotid artery plaques was 6.8 (p=0.010). Conclusion : Carotid MPRAGE-positive signal in patients was associated with an increased risk of territorial acute infarction as detected objectively by brain DWI. The relative risk of stroke was increased in high-grade stenosis categories.