Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Perfusion MR Imaging of the Brain Tumor: Preliminary Report (뇌종야의 관류 자기공명영상: 예비보고)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.119-124
    • /
    • 1997
  • Purpose: To assess the utility of magnetic resonance(MR) cerebral blood volume (CBV) map in the evaluation of brain tumors. Materials and Methods: We performed perfusion MR imaing preoperatively in the consecutive IS patients with intracranial masses(3 meningiomas, 2 glioblastoma multiformes, 3 low grade gliomas, 1 lymphoma, 1 germinoma, 1 neurocytoma, 1 metastasis, 2 abscesses, 1 radionecrosis). The average age of the patients was 42 years (22yr -68yr), composed of 10 males and S females. All MR images were obtained at l.ST imager(Signa, CE Medical Systems, Milwaukee, Wisconsin). The regional CBV map was obtained on the theoretical basis of susceptibility difference induced by first pass circulation of contrast media. (contrast media: IScc of gadopentate dimeglumine, about 2ml/sec by hand, starting at 10 second after first baseline scan). For each patient, a total of 480 images (6 slices, 80 images/slice in 160 sec) were obtained by using gradient echo(CE) single shot echo-planar image(EPI) sequence (TR 2000ms, TE SOms, flip angle $90^{\circ}$, FOV $240{\times}240mm,{\;}matrix{\;}128{\times}128$, slice-thick/gap S/2.S). After data collection, the raw data were transferred to CE workstation and rCBV maps were generated from the numerical integration of ${\Delta}R2^{*} on a voxel by voxel basis, with home made software (${\Delta}R2^{*}=-ln (S/SO)/TE). For easy visual interpretation, relative RCB color coding with reference to the normal white matter was applied and color rCBV maps were obtained. The findings of perfusion MR image were retrospectively correlated with Cd-enhanced images with focus on the degree and extent of perfusion and contrast enhancement. Results: Two cases of glioblastoma multiforme with rim enhancement on Cd-enhanced Tl weighted image showed increased perfusion in the peripheral rim and decreased perfusion in the central necrosis portion. The low grade gliomas appeared as a low perfusion area with poorly defined margin. In 2 cases of brain abscess, the degree of perfusion was similar to that of the normal white matter in the peripheral enhancing rim and was low in the central portion. All meningiomas showed diffuse homogeneous increased perfusion of moderate or high degree. One each of lymphoma and germinoma showed homogenously decreased perfusion with well defined margin. The central neurocytoma showed multifocal increased perfusion areas of moderate or high degree. A few nodules of the multiple metastasis showed increased perfusion of moderate degree. One radionecrosis revealed multiple foci of increased perfusion within the area of decreased perfusion. Conclusion: The rCBV map appears to correlate well with the perfusion state of brain tumor, and may be helpful in discrimination between low grade and high grade gliomas. The further study is needed to clarify the role of perfusion MR image in the evaluation of brain tumor.

  • PDF

Effects of Non-Steroidal Anti-Inflammatory Drugs on the FMLP-Induced Migration of Neutrophil (비스테로이드성 항염증제가 FMLP에 의한 사람 중성구의 이동에 미치는 영향)

  • Kim, Woo-Mi;Kang, Koo-Il
    • The Korean Journal of Pharmacology
    • /
    • v.30 no.1
    • /
    • pp.137-143
    • /
    • 1994
  • Enhancement or diminution of leukocyte migration to the specific site might be important factors for the development of inflammatory diseases. To investigate the effects of non-steroidal anti-inflammatory drugs (NSAIDs) on chemotaxis of neutrophil, we obtained neutrophils by Hypaque-Ficoll step gradient centrifugation and tested the effects of seven drugs on the n-formyl-leucyl-phenylalanine (FMLP)-induced migration of neutrophil using a 48-well micro chemotaxis assembly. Oxyphenbutazone, phenylbutazone, sulindac, zomepirac, and ibuprofen suppressed the migration of neutrophil at the therapeutic concentrations, however, indomethacin showed stimulation effect. IC50s for inhibition of neutrophil migration by these drugs are less than 100uM. When drugs were preincubated with FMLP, no inhibition on migration of neutrophil was observed. These results indicated that inhibitory effects of these drugs on migration of neutrophil might be related to the receptor sites of neutrophil rather than molecular inactivation of chemoattractant (FMLP). In conclusion, we suggested that the property of inhibition effects on neutrophil migration of several NSAIDs might be another mode of pharmacological action for anti-iflammatory effect, which showed significant effects at concentrations below therapeutic levels, in addition to cyclooxygenase inhibition.

  • PDF

Comparison between Stimulus and Response AC/A Ratios for Each Phoria with Additional Spherical Power (사위별 가입렌즈에 따른 자극 AC/A비와 반응 AC/A비의 비교)

  • Lee, Se-Hee;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.345-351
    • /
    • 2014
  • Purpose: The accommodative response and the near horizontal phoria were examined with additional spherical power to analyze the stimulus and response AC/A ratios that suggest reference data for the binocular vision. Methods: The open-field autorefractometer (Nvision-K 5001, Shin nippon) and modified thorington method (MIM card; Muscle Imbalance Measure card, Bernell) at 40 cm were utilized to measure the accommodative response and the near horizontal phoria for 81 persons ($20.89{\pm}1.92$ years old) with additional spherical power. The stimulus and the response AC/A ratios were calculated by gradient AC/A method. Results: The exophoria group showed the highest accommodative response ($1.92{\pm}0.26D$) at 40 cm, followed by orthophoria group and esophoria group($1.72{\pm}0.26D$ and $1.62{\pm}0.42D$, respectively) Meanwhile, the esophoria group showed the biggest ocular deviation for the near ($23.24{\Delta}$) followed by the orthophoria group and exophoria group ($19.76{\Delta}$ and $15.14{\Delta}$, respectively). The biggest difference of the stimulus and the response AC/A ratios was $1.72{\Delta}$ for the exophoria group with -2.00 D, while the one was $3.43{\Delta}$ for the esophoria group with +1.00 D. There was a significant difference between AC/A ratios for the exophoria group with -2.00 D, -1.00 D and the esophoria group with +3.00 D, +2.00D, +1.00D and -1.00D. Conclusions: The difference between stimulus and response AC/A was greater when increased minus spherical power for the exophoria group, while it was greater when increased plus spherical power for the esophoria group. Furthermore, the difference for the esophoria group was a greater than the one for the exophoria group.

Method Development of Ellagic Acid as Marker Compound for Standardization of Gochang Bokbunja (Rubus coreanus Miquel) as Functional Ingredient (고창 복분자의 기능성원료 표준화를 위한 지표성분으로서 Ellagic Acid의 분석법 개발)

  • Kim, Yunjeong;Han, Song-Hee;Jeon, Ji-Yeong;Hwang, Minho;Im, Yong-Jin;Chae, Soo-Wan;Kim, Min-Gul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.11
    • /
    • pp.1554-1558
    • /
    • 2012
  • Method development and validation of ellagic acid for the standardization of Gochang Bokbunja as a functional ingredient and health food were accomplished. A Symmetry$^{(R)}$ (C18, $4.6{\times}250mm$, $5.0{\mu}m$) column was used with a gradient elution system of 1% formic acid in water and acetonitrile. This method was validated according to specificity, linearity, accuracy, precision test, and recovery test. Specificity was confirmed with identical retention time, and calibration curves of ellagic acid showed good linear regression ($R^2$ >0.9996). Relative standard deviations (RSD) of data from the intra- and inter-day experiments were less than 2.28% and 2.84%, except in the low limit of quality control (LLOQ, $1{\mu}g/mL$) sample. The results of the recovery test were from 89.17% to 97.92% with RSD values from 0.05 to 0.14%. Therefore, we performed analysis of ellagic acid as a marker compound in Gochang Bokbunja extracts. The amount of ellagic acid in Gochang Bukbunja was about $1.918{\mu}g/mg$ (0.192%) in the three times analysis, and RSD was less than 2.36% by the validated method. These results suggest that the developed HPLC method is simple, efficient, and could contribute to the quality control of Gochang Bokbunja extract as a functional ingredient.

Magnetic Resonance Voiding Cystography in the Diagnosis of Vesicoureteral Reflux: Comparative Study with Voiding Cystourethrography (방광요관역류의 진단에 있어서 자기공명 배뇨성 방광조영술의 유용성: 태뇨성 요도방광조영술과의 비교연구)

  • Lee, Sang-Kwon;Chang, Yong-Min;Koo, Ja-Hoon;Ko, Cheol-Woo;Chung, Sung-Kwang;Kim, Tae-Hun;Sohn, Kyung-Sik;Lee, Chang-Hyun;Kim, Young-Hwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.85-93
    • /
    • 2000
  • Purpose: To evaluate the availability of magnetic resonance (MRI voiding cystography for the diagnosis of vesicoureteral reflux (VUR) and to compare the sensitivity of MR voiding cystography (MRVC) with that of radiographic voiding cystourethrography (VCUG) in the detection of VUR. Material and Methods : MRVC was performed upon 20 children referred for investigation of VUR. Either coronal T1-weighted spin-echo or spoiled gradient-echo images were obtained before and after transurethral administration of a mixture of normal saline and gadopentetate dimeglumine, and immediately after voiding. The findings of MRVC were compared with those of VCUG performed within 6 months of MRVC. Results 1 VUR was detected in 23 ureterorenal units f16 VUR's by both methods, five VUR's by VCUG, and two VUR's by MRVC). The sensitivity of VCUG and MRVC in detecting VUR was 91.3% (21/23) and 78.3% (18/23), respectively. MRVC detected renal scarring in 15 out of 17 kidneys with scintigraphically detected renal scarring. Conclusion : Although MRVC is slightly less sensitive than VCUG in the detection of VUR, it can be used for the diagnosis of VUR and renal scarring simultaneouslyl and thus will reduce the radiation hazard.

  • PDF

High-Resolution Contrast-Enhanced 3D-Spoiled Gradient-Recalled Imaging for Evaluation of Intracranial Vertebral Artery and Posterior Inferior Cerebellar Artery in Lateral Medullary Infarction (고해상도 조영증강 삼차원 회손기울기 회상 영상을 이용한 측면연수경색 환자의 두개내 척추동맥 및 뒤아래소뇌동맥 평가)

  • Yoon, Youngno;Ahn, Sung Jun;Suh, Sang Hyun;Park, Ah Young;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • Purpose : To determine whether high-resolution contrast-enhanced three dimensional imaging with spoiled gradient-recalled sequence (HR-CE 3D-SPGR) plays a meaningful role in the assessment of intracranial vertebral artery (ICVA) and posterior inferior cerebellar artery (PICA) in lateral medullary infarction (LMI). Materials and Methods: Twenty-five patients confirmed with LMI were retrospectively enrolled with approval by the IRB of our institute, and 3T MRI with HR-CE 3D-SPGR and contrast-enhanced magnetic resonance angiography (CE-MRA) were performed. Two radiologists who were blinded to clinical information and other brain MR images including diffusion weighted image independently evaluated arterial lesions in ICVA and PICA. The demographic characteristics, the area of LMI and cerebellar involvement were analyzed and compared between patients with arterial lesion in ICVA only and patients with arterial lesions in both ICVA and PICA on HR-CE 3D-SPGR. Results: Twenty-two of twenty-five LMI patients had arterial lesions in ICVA or PICA on HR-CE 3D SPGR. However twelve arterial lesions in PICA were not shown on CE-MRA. Concurrent cerebellar involvement appeared more in LMI patients with arterial lesion in ICVA and PICA than those with arterial lesion in ICVA alone (p = 0.069). Conclusion: HR-CE 3D-SPGR can help evaluate arterial lesions in ICVA and PICA for LMI patients.

Gaussian Filtering Effects on Brain Tissue-masked Susceptibility Weighted Images to Optimize Voxel-based Analysis (화소 분석의 최적화를 위해 자화감수성 영상에 나타난 뇌조직의 가우시안 필터 효과 연구)

  • Hwang, Eo-Jin;Kim, Min-Ji;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.275-285
    • /
    • 2013
  • Purpose : The objective of this study was to investigate effects of different smoothing kernel sizes on brain tissue-masked susceptibility-weighted images (SWI) obtained from normal elderly subjects using voxel-based analyses. Materials and Methods: Twenty healthy human volunteers (mean $age{\pm}SD$ = $67.8{\pm}6.09$ years, 14 females and 6 males) were studied after informed consent. A fully first-order flow-compensated three-dimensional (3D) gradient-echo sequence ran to obtain axial magnitude and phase images to generate SWI data. In addition, sagittal 3D T1-weighted images were acquired with the magnetization-prepared rapid acquisition of gradient-echo sequence for brain tissue segmentation and imaging registration. Both paramagnetically (PSWI) and diamagnetically (NSWI) phase-masked SWI data were obtained with masking out non-brain tissues. Finally, both tissue-masked PSWI and NSWI data were smoothed using different smoothing kernel sizes that were isotropic 0, 2, 4, and 8 mm Gaussian kernels. The voxel-based comparisons were performed using a paired t-test between PSWI and NSWI for each smoothing kernel size. Results: The significance of comparisons increased with increasing smoothing kernel sizes. Signals from NSWI were greater than those from PSWI. The smoothing kernel size of four was optimal to use voxel-based comparisons. The bilaterally different areas were found on multiple brain regions. Conclusion: The paramagnetic (positive) phase mask led to reduce signals from high susceptibility areas. To minimize partial volume effects and contributions of large vessels, the voxel-based analysis on SWI with masked non-brain components should be utilized.

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

Monitoring Ground-level SO2 Concentrations Based on a Stacking Ensemble Approach Using Satellite Data and Numerical Models (위성 자료와 수치모델 자료를 활용한 스태킹 앙상블 기반 SO2 지상농도 추정)

  • Choi, Hyunyoung;Kang, Yoojin;Im, Jungho;Shin, Minso;Park, Seohui;Kim, Sang-Min
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_3
    • /
    • pp.1053-1066
    • /
    • 2020
  • Sulfur dioxide (SO2) is primarily released through industrial, residential, and transportation activities, and creates secondary air pollutants through chemical reactions in the atmosphere. Long-term exposure to SO2 can result in a negative effect on the human body causing respiratory or cardiovascular disease, which makes the effective and continuous monitoring of SO2 crucial. In South Korea, SO2 monitoring at ground stations has been performed, but this does not provide spatially continuous information of SO2 concentrations. Thus, this research estimated spatially continuous ground-level SO2 concentrations at 1 km resolution over South Korea through the synergistic use of satellite data and numerical models. A stacking ensemble approach, fusing multiple machine learning algorithms at two levels (i.e., base and meta), was adopted for ground-level SO2 estimation using data from January 2015 to April 2019. Random forest and extreme gradient boosting were used as based models and multiple linear regression was adopted for the meta-model. The cross-validation results showed that the meta-model produced the improved performance by 25% compared to the base models, resulting in the correlation coefficient of 0.48 and root-mean-square-error of 0.0032 ppm. In addition, the temporal transferability of the approach was evaluated for one-year data which were not used in the model development. The spatial distribution of ground-level SO2 concentrations based on the proposed model agreed with the general seasonality of SO2 and the temporal patterns of emission sources.