• 제목/요약/키워드: Graded barrier

검색결과 23건 처리시간 0.025초

가스버너 열충격에 의한 NiCr/ZrO2계 경사기능재의 열적 파괴특성 (Fracture Characteristics of NiCr/ZrO2 Functionally Graded Material by Gas Burner Thermal Shock)

  • 송준희
    • 한국세라믹학회지
    • /
    • 제43권4호
    • /
    • pp.247-252
    • /
    • 2006
  • Joining Yittria Stabilized Zirconia (YSZ) to NiCr metal was fabricated using YSZ/NiCr Functionally Graded Materials (FGM) Interlayer by hot pressing process. Microscopic observations demonstrate that the composition and microstructure of YSZ/NiCr FGM distribute gradually in stepwise way, eliminating the macroscopic ceramic/metal interface such as that in traditional ceramic/metal joint. The thermal characteristics of this YSZ/FGM/NiCr joint were studied by thermal shock testing and therml barrier testing. Thermal shock test was conducted by gas burner rig. Acoustic Emission (AE) monitoring was performed to analyze the microfracture behavior during the thermal shock test. It could be confirmed that FGM was the excellent performance of thermal shock/barrier resistance at above $1000^{\circ}C$.

High Temperature Oxidation Behavior of Plasma Sprayed $ZrO_2$ Having Functionally Gradient Thermal Barrier Coating

  • Park, Cha-Hwan;Lee, Won-Jae;Cho, Kyung-Mox;Park, Ik-Min
    • Corrosion Science and Technology
    • /
    • 제2권3호
    • /
    • pp.155-160
    • /
    • 2003
  • Plasma spraying technique was used to fabricate functionally graded coating (FGC) of NiCrAIY/YSZ 8wt%$Y_2O_3-ZrO_2$ on a Co-base superalloy (HAYNES 188) substrate. Six layers were coated on the substrate for building up compositionally graded architecture. Conventional thermal barrier coating (TBC) of NiCrAIY/SZ with sharp interface was also fabricated. As-coated FGC and TBC samples were exposed at the temperature of $1100^{\circ}C$ for 10, 50, 100 hours in air. Microstructural change of thermally exposed samples was examined. Pores and microcracks were formed in YSZ layer due to evolution of thermal internal stress at high temperature. The amount of pores and microcracks in YSZ layer were increased with increasing exposure time at high temperature. High temperature oxidation of coatings occurred mainly at the NiCrAIY/YSZ interface. In comparison with the case of TBC. the increased area of the NiCrAIY/YSZ interface in FGC is likely to attribute to forming the higher amount of oxides.

JBS(Junction Barrier-controlled Schottky)정류기의 PN접합구조에 따른 I-V 특성에 관한 연구 (A study on I-V characteristics in JBS rectifiers according to PN junction structures)

  • 안병목;정원채
    • 한국전기전자재료학회논문지
    • /
    • 제13권1호
    • /
    • pp.13-20
    • /
    • 2000
  • In this paper, we demonstrated an analytical description method of forward votage drop and reverse leakage current of the junction barrier controlled schottky rectifier with linearly graded junction and abrupt junction models. In this case, the vertical depths of device are 1[${\mu}{\textrm}{m}$] and 2[${\mu}{\textrm}{m}$], respectively. Through ion implantation and annealing process, we obtain the data of lateral and depth from implanted 2-dimensional profiles. Also we applied these data to models that indicate the change of depletion each on linearly-graded and abrupt juction as the forward and revers bias. After applied depletion changes to electric characteristics of JBS rectifiers, we calculated the forward I-V, the reverse leakage current and temperatures vs. power dissipations according to each junction. When we compared the rectifier with calculated and measured data, from the calculated results, forward votage drop with linearly graded junction is lower than that of abrupt junction and reverse leakage current with linearly graded junction is lower(≒1$\times$10\ulcorner times) than that of abrupt junction. Also, the power dissipations according to different juction depth(1[${\mu}{\textrm}{m}$], 2[${\mu}{\textrm}{m}$]) of device are calculated. Seeing the calculated results, we confirmed it from analytic model that the rectifier with linearly graded junction retained a low power dissipation up to 600[$^{\circ}C$] in comparison with the rectifier with abrupt junction.

  • PDF

Numerical Study of Enhanced Performance in InGaN Light-Emitting Diodes with Graded-composition AlGaInN Barriers

  • Kim, Su Jin;Kim, Tae Geun
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.16-21
    • /
    • 2013
  • In this paper, we report the effect of GaN/graded-composition AlGaInN/GaN quantum barriers in active regions on the electrical and optical properties of GaN-based vertical light emitting diodes (VLEDs). By modifying the aluminum composition profile within the AlGaInN quantum barrier, we have achieved improvements in the output power and the internal quantum efficiency (IQE) as compared to VLEDs using conventional GaN barriers. The forward voltages at 350 mA were calculated to be 3.5 and 4.0 V for VLEDs with GaN/graded-composition AlGaInN/GaN barriers and GaN barriers, respectively. The light-output power and IQE of VLEDs with GaN/graded-composition AlGaInN/GaN barriers were also increased by 4.3% and 9.51%, respectively, as compared to those with GaN barriers.

경사기능성 지르코니아 용사피복층의 열 및 기계적특성 (Thermal and Mechanical Characteristics of Functionally Graded ZrO$_2$ Thermal Spray Coating)

  • 오동현
    • 한국표면공학회지
    • /
    • 제31권2호
    • /
    • pp.91-100
    • /
    • 1998
  • NiCrAlY/YSZ(8wt%$Y_2O_3-ZrO_2$) functionally graded thermal barrier coating (FGC) layers on a Co-base superalloy (HAYNESS 188) substrate were fabstrate were fabicated using Ar shielded single torch air plasma spraying method. Functional grading with the stepwise compositional change throughout layer thickness. Microstructural observation trvealed a successful fabrication of NiCrAlY/YSZ FGC. From the results of the curvature measurement, adhesive strength measurement and thermal shock test for the FGC, it was concluded that the optimum conditions of functionally graded coating layer thinkness and compositional pattern exit to enhance the properties of FGC, which is closely related to the internal residual stess distribution witin it.

  • PDF

복합재 형상의 FEA기반 설계를 위한 통합 CAD 시스템 (An Integrated CAD System for FEA-based Design of Heterogeneous Objects)

  • 신기훈;김주한
    • 한국CDE학회논문집
    • /
    • 제10권5호
    • /
    • pp.328-338
    • /
    • 2005
  • CAD systems are routinely used by designers for creating part geometries. Interfaces to CAE/CAM systems are also commonplace enabling the FEA-based design optimization and the rapid fabrication of the designed part. However, conventional CAD systems have thus far focused on objects with homogeneous interior. Two recent advances--use of heterogeneous objects such as Functionally Graded Materials (FGM) in parts and Layered Manufacturing Technology (LMT)--have brought to the forefront the need for CAD systems to support the creation of geometry as well as the graded material inside. We first describe the need and the components of such a CAD system for heterogeneous objects. A prototype CAD system is then described with one specific example (thermal barrier type FGM, pressure vessel) in order to illustrate the use of the implemented CAD system. The implemented system is manually integrated with FEA tools for optimal design. Our ongoing work involves the automation of the integration with FEA tools.

Modified Airy Function Method Applied to Optical Waveguides and Quantum Tunneling: A Critical Analysis

  • Lee, Ki-Young;Kim, Chul Han;Park, Dongwook;Kim, Chang-Min
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.188-198
    • /
    • 2015
  • The validity of applying the Modified Airy Function (MAF) method to the problems of graded-index optical waveguides and graded potential barrier analysis was critically examined. In the former case, the method yielded very accurate results from the derived eigenvalue equations. In the latter case, however, the same method produced results that deviated significantly from exact numerical results for barriers with a smooth peak. The causes of the discrepancies were investigated in detail.

세라믹(PSZ)/금속(NiCrAlY) 경사기능성 복합재료의 화염 열충격 파괴특성 (Fracture Characteristics of Flame Thermal Shock in PSZ/NiCrAlY FGM)

  • 송준희;문상돈
    • 대한금속재료학회지
    • /
    • 제48권8호
    • /
    • pp.775-779
    • /
    • 2010
  • Functionally graded materials (FGM) of PSZ/NiCrAlY on Inconel substrate were fabricated by detonation gun spraying method. A thick ceramic layer generally has a high thermal barrier effect however, because failure often occurs, the use of an FGM layer gives an advantage in thermal property. During the thermal shock test, micro fracture processes were detected by the AE method. Also, the thermal shock test was performed for NFGM, FGM and the changed FGM in the layered composition profile. It was found through AE testing and the observation of fracture surface that FGM was superior to NFGM in thermal shock properties. The linear or metal-rich type FGM in composition profile had the best resisting property among the FGM. It was found that the controlled composition profile of the graded layers had better thermal properties.

An Alternative X-ray Diffraction Analysis for Comprehensive Determination of Structural Properties in Compositionally Graded Strained AlGaN Epilayers

  • Das, Palash;Jana, Sanjay Kumar;Halder, Nripendra N.;Mallik, S.;Mahato, S.S.;Panda, A.K.;Chow, Peter P.;Biswas, Dhrubes
    • Electronic Materials Letters
    • /
    • 제14권6호
    • /
    • pp.784-792
    • /
    • 2018
  • In this letter, a standard deviation based optimization technique has been applied on High Resolution X-ray Diffraction symmetric and asymmetric scan results to accurately determine the Aluminum molar fraction and lattice relaxation of Molecular Beam Epitaxy grown compositionally graded Aluminum Gallium Nitride (AlGaN)/Aluminum Nitride/Gallium Nitride (GaN) heterostructures. Mathews-Blakeslee critical thickness model has been applied in an alternative way to determine the partially relaxed AlGaN epilayer thicknesses. The coupling coefficient determination has been presented in a different perspective involving sample tilt method by off set between the asymmetric planes of GaN and AlGaN. Sample tilt is further increased to determine mosaic tilt ranging between $0.01^{\circ}$ and $0.1^{\circ}$.