• 제목/요약/키워드: Gold-wire

검색결과 57건 처리시간 0.025초

Characteristics of copper wire wedge bonding

  • Tian, Y.;Zhou, Y.;Mayer, M.;Won, S.J.;Lee, S.M.;Cho, S.Y.;Jung, J.P.
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.34-36
    • /
    • 2005
  • Copper wire bonding is an alternative interconnection technology that serves as a viable and cost saving alternative to gold wire bonding. In this paper, ultrasonic wedge bonding with $25{\mu}m$ copper wire on Au/Ni/Cu metallization of a PCB substrate was performed at ambient temperature. The central composite design of experiment (DOE) approach was applied to optimize the copper wire wedge bonding process parameters. After that, pull test of the wedge bond was performed to study the bond strength and to find the optimum bonding parameters. SEM was used to observe the cross section of the wedge bond. The pull test results show good performance of the wedge bond. Additionally, DOE results gave the optimized parameter for both the first bond and the second bond. Cross section analysis shows a continuous interconnection between the copper wire and Au/Ni/Cu metallization. The diffusion of Cu into the Au layer was also observed.

  • PDF

통신기자재용 금도금 특성 분석 연구 (An investigation of characteristics of Au plating for telecommunication components)

  • 한전건;강태만
    • 한국표면공학회지
    • /
    • 제25권6호
    • /
    • pp.309-317
    • /
    • 1992
  • Evaluation of electroplated gold has been carried out to obtain the data base for electrical, mechanical and environmental properties for telecommunication component applications. Gold plating was performed to a various thickness of $0.1\mu\textrm{m}$ to 1.$25\mu\textrm{m}$ after Ni plating of $3\mu\textrm{m}$ on C52100 bronze. Electrical properties were evaluated by measuring contact resistance using 4-wire method under static contact and dynamic contact during wear. Reciprocating wear test was performed to study the wear behavior as well as failure of gold contacts. Environmental characteristics were evaluated by using salt spray testing and SO2 test. Hardness of soft gold film was measured to be 53KHN under 5g load. Friction coefficient was initially obtained to be 0.15 and 0.25 under 100g and 200g loads respectively, and then raised up to 0.8 with increasing reciprocating wear cycles. Static contact resistance was 2 to 3m$\Omega$ regardless of gold film thickness while drastic changes of contact resistance were occured upon stripping of the gold film during wear. The lifetime of contact wear showing stable contact resistance increased up to 6 times for $1\mu\textrm{m}$ thickness compared to that of$ 0.1\mu\textrm{m}$ thickness under 100g load. All gold plating appeared to be stable under salt atmosphere while only the gold plating over 1$\mu\textrm{m}$ was stable under SO2 atmosphere.

  • PDF

금사, 금침, 금주를 중심으로 한 금(金)의 인체 내 매장요법에 대한 연구동향 고찰연구 (A Review of Research Trends in Gold Implantation Therapy Focused on Gold Thread, Gold Needle and Gold Bead)

  • 조대현;아리온치멕;조예은;이상훈;이재동
    • Journal of Acupuncture Research
    • /
    • 제33권1호
    • /
    • pp.79-93
    • /
    • 2016
  • Objectives : The purpose of this study is to explore research trends in gold implantation therapy performed on the animal and human body, through a review of clinical studies focused on gold thread, gold needle and gold bead. Methods : Medical databases, including Pubmed, CENTRAL, MEDLINE, EMBASE, RISS4u, KISTI, OASIS and KTKP, were searched for relevant articles published from their launch to December 31, 2015 using the key word 'gold' with '$thread^*$', '$needle^*$', '$acupuncture^*$', '$wire^*$', '$bead^*$', '$embed^*$', '$implant^*$', or '$insert^*$'. The results were classified into in vivo studies, clinical trials and clinical reports. Analysis of the results was conducted in several research areas, from the identity of studies such as nationality and published year, to the gold preparations-features and implanted locations and to the outcomes that reflect the clinically favorable or adverse effect of gold implantation therapy. Results : A total of 30 studies including 11 in vivo studies, 4 clinical trials and 15 case reports, were found in the search. We observed certain research trends according to the research time, nationality and target indication of the studies. The studies primarily revealed a chronic local inflammatory response which could be a useful mechanism for pain-relief in musculoskeletal diseases and facial rejuvenation. Researches concerning long-term reactions or adverse effects were rare. Conclusion : The results show that the efforts to discover the level of clinical efficacy of gold implantation therapy were steady and worldwide. However, further researches on the longterm effect, and more importantly, the safety of gold implantation therapy are required.

Gold-wire artifacts on diagnostic radiographs: A case report

  • Keestra, Johan Anton Jochum;Jacobs, Reinhilde;Quirynen, Marc
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.81-84
    • /
    • 2014
  • This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

석암리 9호분 출토 금제띠고리의 제작 방법 고찰 (A Study of Metalworking Techniques Seen in the Gold Buckle from Seogam-ri Tomb No. 9)

  • 노지현;유혜선
    • 박물관보존과학
    • /
    • 제17권
    • /
    • pp.1-16
    • /
    • 2016
  • 석암리 9호분 출토 금제띠고리(국보 제189호)는 한반도에서 출토된 가장 이른 시기의 누금세공품으로 금 순도 약 22.8K의 금판에 타출기법으로 일곱 마리의 용이 표현되어 있다. 그리고 약 23.8K의 금선과 금알갱이로 용의 몸통 및 윤곽선, 테두리 등이 장식되어 있다. 이 금제띠고리 곡선면의 일부에는 순도 23.8K의 금판이 덧대어져 있는데, 제작 당시 혹은 그 이후에 발생된 결함을 보완하기 위한 것으로 추정되었다. 금제띠고리에 장식된 용의 코를 표현하는데 사용된 금선은 순도가 23.3K로 약간 낮았다. 이는 동그랗게 감아 말아 만든 용의 코 모양이 잘 유지될 수 있도록 순도가 약간 낮은 금선을 사용하여 경도를 조금 높인 것으로 추정된다. 금알갱이는 크기에 따라 대, 중, 소로 구분되었으며 구리 확산법을 이용하여 접합한 것으로 추정되었다. 용의 이마 및 몸통을 장식하기 위하여 청색 터키석을 감입하였고, 일곱 마리 용의 눈 부분에는 적색 안료인 진사/주(HgS)가 감입되었음을 확인하였다.

Z-axis Contact Detection Algorithm for a Wire Bonder using a Discrete Kalman Filter

  • Kim, Jung-Han
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권1호
    • /
    • pp.52-58
    • /
    • 2007
  • We propose a new contact detection algorithm for fine pitch wire bonding. Fast and stable contact detection of the z-axis in wire bonding is extremely important to maintain the quality of fine pitch gold wire bonding processes, which use a small pad less than $70{\mu}m$ in diameter. A small perturbation in the contact detection time causes a large difference in the size of the formed squashed ball. The new detection method is based on a statistical approach and designed for a discrete Kalman filter. It is faster and has smaller detection time variations than conventional detection methods. Experimental results are presented to demonstrate the advantages of the proposed algorithm.

와이어 본더 시스템의 Z축 표면 접촉 검출 알고리듬 개발 (Contact Detection Algorithm of the Z-axis of a Wire Bonder)

  • 김정한
    • 한국정밀공학회지
    • /
    • 제22권7호
    • /
    • pp.137-145
    • /
    • 2005
  • A new design of contact detection algorithm is proposed for the z-axis of a wire bonder that interconnects between pads and leads in semiconductor manufacturing processes. Fast and stable contact detection of the z-axis is extremely important fer maintaining proper quality in the fine pitch gold wire bonding process, which has a small pad size of below 70um. The new method is based on a statistical approach and designed for the discrete Kalman filter. Real wire bonding experimental results are presented to demonstrate the advantages of the proposed algorithm.

The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.301-308
    • /
    • 2017
  • Objectives: It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Materials and Methods: Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. Results: PTG showed significantly higher NCF than PTU and PTN in group 1 (p < 0.05). Sterilization significantly increased the NCF of PTN and PTG (p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 (p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 (p < 0.05). Conclusions: PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG.

반도체 패키징용 금-코팅된 은 와이어의 부식특성 (Corrosion Characteristics of Gold-Coated Silver Wire for Semiconductor Packaging)

  • 홍원식;김미송;김상엽;전성민;문정탁;김영식
    • Corrosion Science and Technology
    • /
    • 제20권5호
    • /
    • pp.289-294
    • /
    • 2021
  • In this study, after measuring polarization characteristics of 97.3 wt% Ag, Au-Coated 97.3 wt% Ag (ACA) and 100 wt% Au wires in 1 wt% H2SO4 and 1 wt% HCl electrolytes at 25 ℃, corrosion rate and corrosion characteristics were comparatively analyzed. Comparing corrosion potential (ECORR) values in sulfuric acid solution, ACA wire had more than six times higher ECORR value than Au wire. Thus, it seems possible to use a broad applied voltage range of bonding wire for semiconductor packaging which ACA wire could be substituted for the Au wire. However, since the ECORR value of ACA wire was three times lower than that of the Au wire in a hydrochloric acid solution, it was judged that the use range of the applied voltage and current of the bonding wire should be considered. In hydrochloric acid solution, 97.3 wt% Ag wire showed the highest corrosion rate, while ACA and Au showed similar corrosion rates. Additionally, in the case of sulfuric acid solution, all three types showed lower corrosion rates than those under the hydrochloric acid solution environment. The corrosion rate was higher in the order of 97.3 wt% Ag > ACA > 100 wt% Au wires.

WROUGHT WIRE CLASP의 물리적 성질에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON PHYSICAL PROPERTIES OF WROUGHT WIRE CLASP)

  • 이광희;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.201-218
    • /
    • 1989
  • The purpose of this study was to evaluate the influence of attachment technique on mechanical properties and microstructures of wrought wires. The wires tested in this study were precious metal wires: PGP (Platinum-Gold -Palladium), Elastic #12, Denture Clasp, Standard, Jelenko No. 2, Degulor-Klammerdraht, DM (Dong Myung) and base metal wire : Ticonium. Each wire was divided into three groups, and each group was heat treated as embedding, cast to, and soldering state. Heat treated sample was evaluated by tensile test, bending test, microhardness test, element analysis and microstructure test. The obtained results were as follows: 1. In tensile test, cast to and soldering procedures have an effect on wrought wire clasp as hardening heat treatment. 2. Maximum bending strength was significantly increased in Elastic #12, Denture Clasp, Standard, and DM in cast to procedure. 3. Ticonium showed the highest Victors hardness number, followed by PGP, and there was no significant difference in other wrought wires. In cast to and soldering procedure, Victors hardness number was significantly increased in precious wrought wires. 4. The precious wrought wire showed typical fibrous structure and this was disappeared in cast to and soldering procedure. But physical properties were not influenced by this phenomenon.

  • PDF