• 제목/요약/키워드: Goggles

검색결과 53건 처리시간 0.027초

청색광, 가시광선 및 적외선이 차광보안경에 따라 투과되는 투과율 차이 비교 (Comparison of blue light, visible light and infrared light transmittance difference of shading Goggles)

  • 정인호;이상덕;이숙정
    • 대한치과기공학회지
    • /
    • 제42권2호
    • /
    • pp.65-71
    • /
    • 2020
  • Purpose: To know the transmittance of light when wearing shading goggles and to protect eyes from blue light emitted from dental scanner when using CAD/CAM works or inducing polymerization reactions of dental resin with curing unit and infrared light occurred when melting Dental precious metal and non-precious metal alloys. Methods: By measuring and comparing the average transmittances of blue light, visible light and infrared ight by using UV-Vis Spectrophotometer analysis measuring instrument, I compared 3 GREEN Color Goggles worn when casting Dental precious metal and non-precious metal alloys, and compared each of YELLOW, ORANGE Color Goggles worn when using Dental CAD/CAM scanners and Light Curing(LED) the Dental resin. Results: In blue light range, YELLOW Color Goggles are more effective than ORANGE Color Goggles. In infrared light range, No.12 Goggles are more effective than No.10 and No.11 Goggles. Conclusion: When wearing blue light shading goggles to avoid harmful blue light occurred in using dental scanner and curing light, and when wearing infrared light shading goggles to avoid harmful infrared light during casting, to avoid the Side Effects like transmittance rate of blue light and infrared light goggles becomes too high to block appropriate amount of harmful light or too low that causing lower image clarity.

청색광이 광중합기용 팁과 보안경에 따라 투과되는 투과율 차이 비교의 융합적 연구 (A Convergence Study on Comparison of the Difference in the Blue-Light Transmittance by Goggles and Dental Curing Light Unit Tips)

  • 이숙정
    • 한국융합학회논문지
    • /
    • 제10권12호
    • /
    • pp.177-181
    • /
    • 2019
  • 본 연구는 광중합기의 청색광을 이용한 치과 치료과정에서 광중합기용 팁들과 보안경의 청색광 차단정도를 알아보기 위해, UV-Vis 스펙트로미터 기기에 광중합기용 팁들과 보안경들을 위치시키고 빛을 투과하여 측정한 결과를 비교 분석하였다. 분석결과, 분석에 사용한 4가지 종류의 광중합기용 팁들 모두 청색광 차단효과가 매우 우수한 것으로 나타났다. 보안경의 경우 붉은색 계열 보안경이 노란색 계열 보안경보다 광중합기용 팁들과 유사한 청색광 투과율을 보여 청색광 차단효과가 더 우수한 것으로 나타났다. 결과적으로 청색광 차단정도가 높은 광중합기용 팁 부착과 보안경 착용이 눈 보호를 위해 필요한 행위임을 추천한다. 이러한 행위는 눈에 대한 지속적인 자극과 피로감을 줄여줄 것이라 사료된다.

도수 수경 착용시 실내와 수중에서의 시각적 만족도 및 시력 평가 (Assessment of Visual satisfaction & Visual Function with Prescription Swimming goggles In-air and Underwater)

  • 추병선
    • 한국안광학회지
    • /
    • 제18권4호
    • /
    • pp.357-363
    • /
    • 2013
  • 목적: 실내수영장에서 도수 수경 착용에 따른 주관적 만족도 평가와 실내 검사실 및 수중에서의 시력을 비교하고자 한다. 방법: 실험에 참여한 대상자는 평균나이가 $22{\pm}1.54$세인 15명의 대학생이었으며, 오른쪽 눈과 왼쪽 눈의 평균 굴절이상은 각각 RE: S-1.67 D/C-0.40 D, LE: S-1.70D/C-0.37 D이었다. 모든 참여자는 기초적인 안과검사를 마쳤으며, 굴절이상을 교정하기 위한 콘택트렌즈 착용이 가능하고 수영이 가능한 자로 한정하였다. 모든 피실험자의 굴절이상은 콘택트렌즈를 이용하여, 정시상태로 교정을 하였다. 난시가 인위적으로 유발된 원주도수 수경(C+1.50 D, Ax $90^{\circ}$)을 착용하였을 때와 도수가 없는 수경을 착용하였을 때 시력, 안정피로, 그리고 수영장 주위를 걸을 때의 균형감각에 대한 주관적인 만족도 평가를 설문지를 이용하여 실시하였다. 시력 평가는 처방 S+3.00 D ~ S-3.00 D까지 0.50 D단위로 준비된 서로 다른 도수의 수경을 무작위의 순서로 착용한 상태에서 수영장내의 수중과 실내의 검사실에서 ETDRS 시표를 사용하여 측정하였다. 결과: 난시가 인위적으로 유발된 상태에서는 시력, 안정피로, 균형감각에 대한 3가지 만족도가 모두 유의하게 저하되는 것으로 나타났다. 서로 다른 도수의 수경을 착용하였을 때 시력은 유의하게 영향을 받는 것으로 나타났으나(p<0.05), 실내 검사실과 수중에서 측정된 시력의 차이는 없었다(p=0.173). 일부 도수 수경(+3.00, +1.00, +0.50, 0, -1.00, -2.00 D)에서는 실내 검사실에서 측정된 시력이 수중에서 측정된 시력보다 향상된 것으로 나타났다. 결론: 수중에서 수경을 착용하는 것은 시력을 저하시킬 수 있지만 저하되는 시력의 정도는 스넬렌 시력기준 1라인 이내 차이로써 실제 임상에서는 거의 영향이 없을 정도로 적은 수준이었다. 하지만 난시의 미교정은 시각적 만족도에 영향을 미치는 것으로 나타났으므로, 수영장의 미끄러운 환경을 고려하였을 때 안전사고의 위험이 내재한다고 할 수 있다. 따라서 도수 수경의 도수의 정확성과 더불어 난시의 교정이 필요하다고 할 수 있다.

A Comparison of Visual Occlusion Methods: Touch Screen Device vs. PLATO Goggles

  • Park, Jung-Chul
    • 대한인간공학회지
    • /
    • 제30권5호
    • /
    • pp.589-595
    • /
    • 2011
  • Objective: This study compares two visual occlusion methods for the evaluation of in-vehicle interfaces. Background: Visual occlusion is a visual demand measuring technique which uses periodic vision/occlusion cycle to simulate a driving(or mobile) environment. It has been widely used for the evaluation of in-vehicle interfaces. There are two major implementation methods for this technique: (1) occlusion using PLATO(portable liquid crystal apparatus for tachistoscopic occlusion) goggles; (2) occlusion using a software application on a touchscreen device. Method: An experiment was conducted to examine the visual demand of an in-vehicle interface prototype using the goggle-based and the touchscreen-based occlusion methods. Address input and radio tuning tasks were evaluated in the experiment. Results: The results showed that, for the radio tuning task, there were no significant differences in total shutter open time and resumability ratio between the two occlusionconditions. However, it took longer for the participants to input addresses with the touchscreen-based occlusion. Conclusion & Application: The results suggest that touchscreen-based method could be used as an alternative to traditional, gogglebased visual occlusion especially in less demanding visual tasks such as radio tuning.

일개지역 치과위생사의 감염관리 실태에 관한 연구 (Actual status of infection control by the dental hygienist in Korea)

  • 윤경옥
    • 한국치위생학회지
    • /
    • 제13권3호
    • /
    • pp.369-376
    • /
    • 2013
  • Objectives : The objectives of this study is to investigate the handwashing and use of personal protection equipment in dental hygienists and provide the basic data for dental infection control guideline. Methods : A questionnaire survey was performed in the dental hygienists who participated in the continuing education by the Daejeon City Commission in October 2012. The collected data were analyzed using PASW 18.0. Results : Handwashing was well practiced in group working for 3 to 5 years of employment. Those who took the infection cnotrol training used liquid soap, paper towel, dental mask, protective goggles, face shield, and gloves. Conclusions : Infection control is the most important practice in dental hygienists. So it is necessary to emphasize the inportnace of personal protection equipment including medical gloves, dental mask, and goggles.

야시조명계통 요구도 분석 (Analysis of Requirements for Night Vision Imaging System)

  • 권종광;이대열;김환우
    • 한국군사과학기술학회지
    • /
    • 제10권3호
    • /
    • pp.51-61
    • /
    • 2007
  • This paper concerns about the requirement analysis for night vision imaging system(NVIS), whose purpose is to intensify the available nighttime near infrared(IR) radiation sufficiently to be caught by the human eyes on a miniature green phosphor screen. The requirements for NVIS are NVIS radiance(NR), chromaticity, daylight legibility/readability, etc. The NR is a quantitative measure of night vision goggle (NVG) compatibility of a light source as viewed through goggles. The chromaticity is the quality of a color as determined by its purity and dominant wavelength. The daylight legibility/readability is the degree at which words are readable based on appearance and a measure of an instrument's ability to display incremental changes in its output value. In this paper, the requirements of NR, chromaticity, and daylight legibility/readability for Type I and Class B/C NVIS are analyzed. Also the rationale is shown with respect to those requirements.

Zigbee와 GPS를 이용한 해녀 사고예방 스마트 모니터링 시스템 개발 (Development of Accident-prevention Smart Monitoring System for Woman Diver using Zigbee Module and GPS Sensor)

  • 최민호;김영상
    • 스마트미디어저널
    • /
    • 제5권3호
    • /
    • pp.74-80
    • /
    • 2016
  • 본 논문에서는 Zigbee와 GPS센서를 이용한 해녀 사고예방 스마트 모니터링 시스템을 제안하였다. 이 시스템은 해녀들이 바다속에서 조업중에 있을 때, 물질하는 위치, 체온, 잠수의 깊이, 잠수 시간 등의 정보를 수집하여 안전사고 발생시 곧바로 대처할 수 있다. 본 연구에서는 해녀의 상태 및 물질 활동 정보 측정을 위한 스마트테왁과 스마트물안경을 개발하였다. GPS 수신이 가능한 스마트테왁은 스마트물안경과 Zigbee통신으로 측정된 데이터를 IHSS(IoT based Haenyeo Safety service Software)의 서버로 전송한다. 또한, IHSS는 반응형 웹으로 해녀의 위치 정보와 상태 정보를 스마트폰으로 서비스할 수 있다. 결론적으로 이 시스템은 해녀의 건강관리 및 안전 측면에서 매우 유용할 것이며, 유네스코 세계 무형문화유산 등재 기반 등 제주해녀의 세계화 마케팅에도 크게 기여할 것이다.

임상 적용 차폐물질에 따른 선량 및 CT 화질 변화 분석 (Analysis of CT Image Quality Change according to Clinical Application Shielding Materials)

  • 김현주
    • 한국방사선학회논문지
    • /
    • 제17권2호
    • /
    • pp.215-221
    • /
    • 2023
  • 수정체가 포함된 Brain CT 스캔 조건 중 관전압을 80, 100, 120 kVp로 변화시켜 적용하고 납, 납 고글, 황산바륨 실리콘 혼합 차폐체를 이용하여 선량의 변화를 분석하고, 차폐체가 화질에 영향을 미치는 정도를 SNR, CNR, SSIM 지수 분석방법을 적용하여 비교 분석해 보았다. 그 결과 모든 차폐물질 적용으로 선량 감소는 하였지만, 선량 감소 차는 크지 않은 것으로 분석되었다(P > 0.05). 또한 차폐물질 적용으로 화질의 변화는 납 고글 적용 시 SNR, CNR이 가장 높았고 SSIM 분석에서도 기준값 1에 가장 근접하여 구조적 유사도가 가장 우수한 것으로 측정되었다. 따라서, 본 연구결과를 기준으로 더욱 다양한 차폐체 적용과 임상실험 결과를 도출하여 적용한다면 차폐체 활용 검사 시 임상 적용기준에 도움을 줄 수 있을 것으로 사료된다.

가금류 악성 전염병 감염축 처리자의 보호 장비 착용실태 조사 및 개선에 관한 연구 (A study on wearing practice and improvement of personal protective equipment for participant handling livestock carcass infected with virulent avian infectious agents)

  • 이혜연;임의형;김종원;김원일;강아름;임채웅;홍철운;한지현;강석진;김범석
    • 한국동물위생학회지
    • /
    • 제38권4호
    • /
    • pp.241-248
    • /
    • 2015
  • This study was aimed to investigate factors that affected the status of wearing personal protective equipment (PPE) for handling poultry carcasses with potential exposure to virulent avian infectious agents. A large outbreak of high pathogenic avian influenza (HPAI) occurred in South Korea in 2014. Many public officers participated for euthanizing and handling livestock carcass. However, several safety issues with using PPE were revealed. Therefore, a questionnaire survey was conducted for 340 people who participated euthanasia and carcass disposal in the place where HPAI mainly occurred in 2014. It was found that 31.8% of the respondents had ever taken off their protective equipment during operations because of its inconvenience. The most inconvenient PPE was goggles (54.6%), followed by mask (20.2%), latex gloves (11.6%), shoe covers (5.9%) and protective clothing (5.3%). The main complaints about this individual PPE was unclear sight, damp emitted toward eye, sweating, tearing easily and sweating, respectively. Considering such problems of PPE, new possible directions for improvement of gloves and goggles were suggested. With newly developed rubber coating fabric gloves and conventionally using latex and fabric gloves, H3N2 influenza virus transmission experiment was conducted. Rubber coating fabric gloves showed similar efficiency for blocking virus transmission with latex laboratory gloves and were not easily torn by sharp claws of chicken. In addition, air flow control safety eyewear was suggested to minimize moisture formation. The air flow control system efficiently suppressed moisture formation inside the goggles. Therefore our study will provide more specific directions about new PPE development for safety protection of actual wearers.