The Experimental Study of Atomization Characteristics of Gasoline Spray Impinging on Glow Plug

  • Moon, Young-ho;Oh, Young-taig
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.270-278
    • /
    • 2002
  • In order to reduce the exhaust emissions of a spark ignition engine, it is important not only to improve the catalyst conversion efficiency, but also to directly reduce the engine-out exhaust emissions during a cold starting of the engine and warm up periods. The purpose of this study is to evaluate feasibility of a glow plug for an early fuel evaporator. In order to promote atomization, gasoline is injected on the glow plug with room temperature(20$\^{C}$) and high temperature(250$\^{C}$). To analyze the spray behavior characteristics, a PMAS is used to measure the SMD and the dropsize distribution of an impinging spray and a free spray. Results show that the evaporation rate of the impinging spray on the high temperature surface of the glow plug was higher than that of the free spray on the room temperature surface.

Generation and Application of Atmospheric Pressure Glow Plasma in Micro Channel Reactor (마이크로 채널 반응기 내 상압 글로우 플라즈마 생성 및 응용)

  • Lee, Dae-Hoon;Park, Hyoun-Hyang;Lee, Jae-Ok;Lee, Seung-S.;Song, Young-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1869-1873
    • /
    • 2008
  • In this work, to make it possible to generate glow discharge in atmospheric pressure condition with relatively high and wide electric field, micro channel reactor is proposed. Si DRIE and Cr deposition by Ebeam evaporation is used to make channel and bottom electrode layer. Upper electrode is made from ITO glass to visualize discharge within micro channel. Fabricated reactor is verified by generating uniform glow plasma with N2 / He gases each as working fluid. The range of gas electric field to generate glow plasma is from about 200 V/cm and upper limit is not observed in tested condition of up to 150 kV/cm. This data shows that micro channel plasma reactor is more versatile. Indirect estimation of electron temperature in this reactor can be inferred that the electron temperature within glow discharge in micro reactor lies $0{\sim}2eV$. This research demonstrates that the reactor is appropriate in application that needs to maintain low temperature condition during chemical process.

  • PDF

Optimal Annealing of Natural Beryl for Thermoluminescent Dosimetry

  • Moon, Philip S.
    • Nuclear Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.3-8
    • /
    • 1974
  • The annealing of natural beryl powder used for the thermoluminescent dosimetry was investigated in order to eliminate effect of previous exposure. Through the glow curve analysis, the optimal annealing treatment was found to be one hour annealing at 145$0^{\circ}C$, but annealing for one hour at 55$0^{\circ}C$ was sufficient for reuse of natural beryl powder. There are two distinguished glow peaks at $65^{\circ}C$ and 20$0^{\circ}C$ of heating temperature during readout process. The $65^{\circ}C$ glow peak fades away rapidly, but the 20$0^{\circ}C$ glow peak remains very stable. It is, therefore, quite feasible to use the 20$0^{\circ}C$ glow peak for thermoluminescent dosimetry.

  • PDF

Changes in Thermoluminescence of Mineral Separated from Irradiated Shellfish under Various Storage Conditions

  • Yi, Sang-Duk;Yang, Jae-Seung
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2001
  • A study was carried out to establish a detection method of irradiated shellfish through thermoluminescence (TL). The TL intensity of first glow curves for irradiated bloody, freshwater, and short-neck shellfish increased from control until 5 kGy and increased slightly room 5 kGy until 10 kGy. Maximum TL temperatures of all irradiated samples tested were below 23$0^{\circ}C$, within temperature interval of 150~25$0^{\circ}C$ recommended for evaluation. Since just in control, glow curve ratios of G3 and G4 calculated from re-irradiated (1 kGy) bloody, freshwater and shortneck were over 0.5, detection in control was possible. However, as glow curve ratios after three months were below 0.5, detection by glow curve ratios after three months was impossible. Gl, which calculated from unirradiated samples, exhibited below 0.1, they were classified as unirradiated. In all samples, all the irradiated shellfish could be classified correctly as irradiated by hemaximum TL temperatures and shape of the second glow curve because those were shown in a lower temperature region than those of the first glow curve.

  • PDF

A Study for the Improvement of Start Ability and Exhaust Emissions in a Conventional Mixer Type LPG Engine on Cold Start (LPG 엔진의 냉 시동시 시동성 개선 및 배출들 저감을 위한 연구)

  • 김우석;이종화
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.84-92
    • /
    • 2002
  • On the cold start of LPG engine, as the engine temperature has not reached its equilibrium temperature, liquid LPG could not be changed perfectly gaseous LPG, although it was passed to the vaporizer. Liquid and gas mixed fuel could influence starting ability and exhaust emission characteristics of LPG engine. In this study, the vaporization characteristic of liquid LPG was investigated with a conventional vaporizer and the vaporizer with heat source(glow plug) installed at preheated chamber inlet, by using the visualization methods and engine test. According to visualization result, even if the engine coolant temperature was $14^{\circ}C$, liquid fuel was supplied to primary chamber over 25 seconds without vaporizing from preheated chamber in such a conventional vaporizer. However, the vaporizer with heat source do not correspond with that, scarcely had been trim on glow plug when LPG began to vaporize. The effectiveness of heat source could be verified by application to the conventional LPG engine.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

Fabrication of $CaSO_4:Eu$ TLD and Its Physical Characteristics ($CaSO_4:Eu$ TLD의 제작과 물리적 특성)

  • Kim, Do-Sung;Park, Myeong-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.388-393
    • /
    • 1999
  • In this study, the $CaSO_4:Eu$ TLDs are fabricated and their trap parameters are determined. The optimum concentration of Eu for fabrication of the $CaSO_4:Eu$ TLD is 0.5 mol% and optimum temperature is $600^{\circ}C$ for 2 hours sintering in air. The glow curve of $CaSO_4:Eu$ consists of two glow peaks and these peaks are isolated by thermal bleaching method. Trap parameters of two glow peaks are measured using the initial rise, the peak shape, the heating rate and the least square curve fitting methods. The activation energies of the glow peak I and II are 1.00 eV and 1.09 eV, and the frequency factors are $7.04{\times}10^{11}\;s^{-1}$ and $5.12{\times}10^{11}\;s^{-1}$ and the kinetic orders are 1.11 and 1.33, respectively.

  • PDF

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

The Physicochemical Characteristics of PET Fabrics Treated with Low Temperature Glow Plasma and Atmospheric Corona Discharge (진공 저온 플라즈마와 대기압 코로나 방전가공 PET 직물의 물리화학적 특성)

  • Ma, Jaehyuk;Yang, Jinyoung;Koo, Kang;Yang, Hyun A;Park, Youngmi
    • Textile Coloration and Finishing
    • /
    • v.26 no.3
    • /
    • pp.201-208
    • /
    • 2014
  • The high value-added functionality for synthetic fiber can be considered through a plasma enhanced treatment. In this study, PET(Polyethyleneterephthalate) was treated with a glow plasma and corona treatment. Surface characteristics of treated fabric were investigated using electron scanning microscopy(SEM), contact angle, X-ray photoelectron spectroscopy(XPS), tensile and adhesion strength. It was found that the contact angle showed $85.5^{\circ}$ for untreated fabric, $0^{\circ}$ for plasma and corona treatment at the condition of 200W for 7min. By XPS analysis, atomic ratio of O 1s/C 1s was increased from 0.27 to 0.43 by glow plasma and 0.27 to 0.41 by corona treatment at 200W for 7min, respectively. Glow plasma and corona treatment did not significantly change the tensile strength of PET fabric. Adhesion strength showed a substantial enhancement for the surface treated with the glow plasma, while corona treatment was adversely affected.

A Study on the Glow Discharge Characteristics of Facing Target Plasma Process (대향 음극형 플라즈마 프로세스의 글로우 방전특성에 관한 연구)

  • Park, Chung-Hoo;Cho, Jung-Soo;Kim, Kwang-Hwa;Sung, Youl-Mool
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.478-484
    • /
    • 1994
  • Facing target dc sputtering system developed by Hoshi et al. has simple configuration and high deposition rate under moderate substrate temperature in the range of pressure 5x10S0-4T - 1x10S0-2T torr. In this system, magnetic field should be applied perpendicular to the target surface in order to confine high energy secondary electrons between two targets. Because of this magnetic field, the glow discharge characteristics are very different from dc planar diode system showing some unstable discharge region. In this paper, the glow discharge characteristics of this system have been studied under the condition of Ti targets with Ar-NS12T(10%) as working gas. It is found that this system has stable discharge region under the discharge current density of 15-30(mA/cmS02T). The plasma density and electron temperature are in the range of 10S010Y - 10S011T(CMS0-3T) and 2.5-5(eV), respectively.