• 제목/요약/키워드: Gloss polishing

검색결과 9건 처리시간 0.021초

광택용 왁스로서 4차 암모늄염을 함유한 마이크로에멀젼의 특성 (Properties of Microemulsion Containing Quaternary Ammonium Salt as Polishing Wax)

  • 이장원;김명수;정노희
    • 한국응용과학기술학회지
    • /
    • 제21권4호
    • /
    • pp.335-344
    • /
    • 2004
  • In this work, the properties as polishing wax for automobile of O/W type microemulsion containing wax, liquid paraffine and quaternaryammonium salt was investigated. The microemulsions were prepared at $96{\sim}97^{\circ}C$ by the phase inversion method, and polyoxyethylene(20) sorbitan monooleate (POE(20)SMO) and distearyl dimethyl ammonium chloride(D.D.A.C) as the emulsifiers were used. The mean particle size of the rnicroemulsions was about 7${\pm}$0.5nm and as the properties of polishing wax, gloss increased degree, water resistant gloss degree, initial and final contact angle after water resistance were tested. The result was that the value of water resistantance and contact angle were decreased with increasing amount of POE(20)SMO and D.D.A.C., while the gloss degree values did not affected. And the rnicroemulsion blended with mono ethylene glycol(MEG) of 5${\sim}$15wt% showed smaller particle size and more stable particle size distribution than without MEG. Finally, this microemulsion showed more excellent values of gloss degree, the water resistant gloss degree and contact angle, than two kinds of commercial polishing wax for automobile.

연마 과정에 따른 열중합 의치상 레진의 표면 거칠기 평가 (Evaluation of surface roughness of heat-polymerized denture base resin according to the polishing step)

  • 황성식;임용운;김시철;한민수
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.205-212
    • /
    • 2015
  • Purpose: The objective of this study was to compare the surface roughness according to polishing process in conventional laboratory techniques used for polishing three different acrylic denture base resins. Materials and methods: Specimen preparation and surface polishing procedures were conducted to manufacturer's recommendation with three heat-polymerized denture base resins. Surface roughness and gloss were measured by a contact type tester and a LED gloss checker using thickness 2 mm and diameter 10 mm. There were five specimens for each acrylic resin material and polishing procedures. Mean average surface roughness (Ra) values of each specimen group were analyzed using a one-way ANOVA analysis of variance and Scheffe's post hoc test. Surfaces after surface roughness and gloss testing according to each polishing process were evaluated under a stereoscopic microscope. Results: The highest mean average surface roughness was measured($Ra=2.43{\pm}0.47$) for surfaces finished with a denture tungsten carbide bur in Triplex. The lowest surface roughness values ($Ra=0.11{\pm}0.07$) were determined in Vertex polished with a lathe. In addition, all materials revealed that surface roughness determined highly in HP1 and HP2 than other procedures. All correlation between surface roughness and gloss showed highly with three heat-polymerized resins. Specially, topmost correlation revealed than other material in Triplex. Significant differences in mean average surface roughness were found between polishing process used high speed lathe and low speed hand-piece. Conclusion: Laboratory polishing used to high speed was found to produce the smoothest surface of heat-polymerized denture base acrylic resin. Therefore, we recommended that high polishing process need to get smooth surface.

3D 프린터로 출력된 치과용 레진의 자동바렐연마공정에 따른 표면 거칠기 및 연마도 관찰 (Observation of surface roughness and grinding angle by automatic barrel finishing process of dental 3D printed resin)

  • 박유진;정안나
    • 대한치과기공학회지
    • /
    • 제45권2호
    • /
    • pp.39-47
    • /
    • 2023
  • Purpose: This study aimed to confirm the applicability of gloss polishing using automatic barrel finishing with respect to three-dimensional (3D)-printed resin specimens. The surface roughness and grinding angle of the 3D-printed resin specimens were observed with respect to gloss polishing time using automatic dental barrel finishing. Methods: Herein, experiments were conducted on four types of 3D-printed resin specimens. The specimens, with a thickness of 100 ㎛ each, were printed using a 3D printer. Subsequently, light polymerization was performed on these specimens for 15 min. Post this surface treatment, the specimens underwent grinding for 25 min. This process was followed by gloss polishing at 5-min intervals for up to 25 min using automatic dental barrel finishing. The specimens were photographed using a 3D optical microscope, and their surface roughness and grinding angle were measured. Results: The Ra (centerline average roughness) values of all the specimens, except for crown & bridge 10 group and those in the control group that were not polished using automatic barrel finishing, were <0.2 ㎛. However, polishing time needs to be controlled to realize the desired surface roughness and grinding amount considering the hardness of the resin used. Conclusion: Gloss polishing of 3D-printed resin can be realized using automatic dental barrel finishing. However, polishing time needs to be controlled to realize the desired surface roughness and grinding amount considering the hardness of the resin used.

전해연마를 적용한 미세 마이크로 니들의 표면 향상에 대한 연구 (A study on the Surface Improvement of Fine-Micro Needles Applying Electrochemical Polishing)

  • 정성택;김현정;위은찬;공정식;백승엽
    • Design & Manufacturing
    • /
    • 제13권3호
    • /
    • pp.48-52
    • /
    • 2019
  • As the consumer market in the mold, automation and aerospace industries grows, the demand for chemical machining using on electrochemical polishing increases. To enhance the surface roughness and gloss of the micro-needle, we have studied for an electrochemical polishing. Electrochemical polishing requires the chemical reaction of solution and material according to the electrolyte and electrode. In this study, sulfuric acid(30%), phosphoric acid(50%), and DI-water(20%)were used as the electrolytic solution, and the electrolytic solution temperature used $58^{\circ}C$. Electrochemical polishing was carried out in experimental conditions, and the micro-needle experiment was carried out from the basic experiment to obtain the experimental conditions. Experimental results show that as the voltage and current increase, the surface roughness improved and the gloss is improved. So, the best result for this experiment was obtained in condition 6, which improved micro-needle.

복합레진의 광택 및 표면조도에 관한 연구 (A STUDY ON THE GLOSS AND ROUGHNESS OF THE COMPOSITE RESIN)

  • 조승주;이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.67-80
    • /
    • 1990
  • This study was performed for elucidating the effects on surface polishing of composite resins. In this study, Silux(microfilled), Graft(hybrid), Bisfil- I (hybrid posterior) and Hi-pol(conventional) were used. Sixty specimens were made with 4 brands of composite resins and Optilux system in $2.0{\times}1.3{\times}1.0cm$ resin block which has a cavity with 0.5cm diameter and 0.5cm depth. Polishing was done with #600 sand paper and Soflex, Super-snap, Micron finishing system, or Composite polishing kit. Final polished surfaces were measured by roughness tester(Kasaka Lab. Ltd., Japan) and image analyser(Omnimet Image Analyser, Buehler, USA). The results were as follows, 1. The celluloid strip produced the smoothest surfaces. 2. Light curing microfilled composite resin, Silux, had smoother surface than any others. 3. The surfaces polished by Soflex were smoothest. 4. Aluminum oxide disk, Soflex and Super-Snap, made smoother surface than diamond bur, M.F.S., or silicon point, Composite polishing kit. 5. The roughness values of surface polished by M.F.S. composed of diamond burs, were less than those of Composite polishing kit made from silicone points.

  • PDF

표면도포제에 따른 수복용 글라스 아이오노머 세멘트의 표면조도 비교 (A COMPARATIVE STUDY ON SURFACE ROUGHNESS OF GLASS IONOMER CEMENT BY SURFACE COATING AGENT)

  • 최병재;황동환
    • 대한소아치과학회지
    • /
    • 제23권4호
    • /
    • pp.915-924
    • /
    • 1996
  • The purpose of this paper is to investigate the surface roughness of glass ionomer cement during initial setting time followed by applying surface coating agent. No other finishing or polishing procedure is done and each surface coating agents (varnish, adhesive, gloss, sealant) are used after filling of glass ionomer cement. Surface roughness indices(Ra) are measured and surface contours are obtained electronically by Surfcorder SEF-30D(Kosaka laboratory Ltd., Japan). The results are as follows: 1. During initial setting time, surface roughness increases slightly regardless of surface coating agents. But it is statistically insignificant. (p>0.05) 2. Among surface coating agents used, Ra indices of group using varnish are high significantly compared to other groups regardless of elapsed time.(p<0.05) Among the groups which has used other surface coating agents except for the varnish group, similar Ra index all over the experiment is obtained, when compared to control group (no agent). 3. If no surface treatment is performed, tri-cure glass ionomer cement (Vitremer) has higher Ra Index than light cure glass ionomer cement (Fuji II LC) (t<0.05). But there is no difference between two groups in Ra index if any kinds of agents are applied except for sealant. (t>0.05)

  • PDF

다중초점화상기법(多重焦點畵像技法)을 적용(適用)한 면섬유광택분석(綿纖維光澤分析) 및 면직물(綿織物)의 광택(光澤)에 관(關)한 연구(硏究) (Application of the Multi-Focusing Composite Image for the Cotton Fiber Luster Analysis and Cotton Fabric Luster Analysis)

  • 문선혜;김종준;전동원
    • 패션비즈니스
    • /
    • 제7권5호
    • /
    • pp.108-118
    • /
    • 2003
  • Surface properties, including the texture and the luster, of cotton fibers and yarns thereof play an important role in textile technology. The convolutions and the cross-sectional shape of the cotton fiber affect the fabric texture and the luster accordingly. Mercerization of the cotton fabric affects the luster, strength, and other properties of the fabric. In this study, the effect of mercerization was examined on the luster of the cotton fabric, together with the effect of polishing treatment. One of the traditional methods determining the fabric luster is the use of glossmeter or goniometric glossmeter. The use of glossmeter gives successful results in determining the gloss of rather flat and continuous surface such as plastic sheet, painted surface, or paper products. Since the textile fabrics have diverse surface structures and textures, these could be regarded as having three-dimensional surface. Such complexity imposes some difficulties for differentiating subtle surface luster properties of diverse textile fabrics. The advancement in the area of imaging technologies has enabled the micro-scale analysis of the surface textures and the fabric luster recently. Using a CCD camera, the surface luster images were taken at various incident illumination conditions. Microscale analysis, including the blob analysis, of the images could differentiate the subtle luster properties present in a group of cotton fabric samples comprising mercerized cotton fabric, non-mercerized cotton fabric, polished cotton fabric, and a 'standard' cotton fabric. The glossmeter measurement gave satisfactory but limited differentiation among the samples, whose luster differences are easily recognizable with visual observation, except for the mercerized cotton fabric sample and the non-mercerized cotton fabric. The microscale analysis of the fabric luster could, therefore, help understand the nature of diverse textile fabric luster.

세종 합강리 유적 출토 고대 유리구슬의 특성 연구 (A Characteristics on the Ancient Glass Beads Excavated from the Site of Hapgang-ri in Sejong, Korea)

  • 김은아;김규호;강지원;윤천수
    • 보존과학회지
    • /
    • 제36권5호
    • /
    • pp.405-420
    • /
    • 2020
  • 본 연구는 세종 합강리 유적을 중심으로 발굴 유적과 유물을 조사한 고고학적 접근과 주구토광묘 15호에서 유일하게 출토된 유리구슬의 표면, 단면, 조성 특성을 분석한 보존과학적 접근으로 구분하여 융합적 연구를 시도하였다. 묘의 형태와 출토유물을 통한 고고학적 연구에서 합강리 유적은 주구토광묘의 등장 시기가 2세기 후엽부터이고 유리구슬이 출토된 주구토광묘 15호 편년은 2세기 후엽~3세기 초엽으로 추정할 수 있다. 유리구슬 완형은 형태, 색상 및 제작기법을 파악하고 유리구슬편 16점은 단면관찰과 화학 조성을 분석한 결과에서 청색 계통은 감청색과 자색으로, 적색 계통은 적갈색으로 구분되며 세부 색상에서 청색 계통은 광택과 명도에 따라 다양하게 분포하나 적색 계통은 균일도가 높게 나타난다. 제작기법은 표면의 줄무늬와 기포배열에서 늘인기법으로 확인되며 구슬 양 끝부분에서 열처리나 연마 흔적도 관찰된다. 유리구슬 편 16점의 화학 조성은 포타쉬유리군 3점과 소다유리군 13점으로 분류된다. 소다유리군 13점에 대한 안정제 특성은 청색과 적색 계통에 따라 구분된다. 이중에서 적색 계통의 안정제 특성은 지금까지 다른 지역에서 확인된 적갈색 유리구슬과 다른 조성으로 구분되는 점이 특이하다. 착색제는 청색 계통이 MnO 성분을 함유한 코발트(Co), 그리고 적색 계통은 구리(Cu)와 철(Fe)이다.

소비자 가치기반 디자인 평가 모형: 제품 속성, 인지 속성, 소비자 가치의 3단계 접근 (Design Evaluation Model Based on Consumer Values: Three-step Approach from Product Attributes, Perceived Attributes, to Consumer Values)

  • 김건우;박도형
    • 지능정보연구
    • /
    • 제23권4호
    • /
    • pp.57-76
    • /
    • 2017
  • 최근 정보 기술의 발전 속도가 매우 빠르게 변화하고 있다. 스마트폰과 태블릿 같은 IT 기기에서 이런 변화들이 두드러지고 있다. 이전의 IT 기기들은 기능상의 혁신과 진보를 통해 소비자들을 끌어들였지만, 현재는 IT 제품 상에서 기능상 발전과 혁신은 둔화되었다. 기능상 차별점이 줄어든 시점에서 기업들은 외관과 디자인적 측면에서 차별화를 시도하고 있다. 스마트폰의 외관적 변화를 반영하듯 소비자들도 성능보단 디자인을 스마트폰 구매의 중요 요인으로 삼고 있다. 스마트폰은 패션 아이템의 하나로 자리매김하게 되었고, 스마트폰의 디자인과 외형이 지속적으로 중요해짐에 따라 해당 제품에 대해 소비자들이 느끼는 디자인 가치가 무엇인지도 중요해졌으며, 무엇에 영향을 받는지도 중요해졌다. 소비자들이 느끼는 가치가 중요해짐에 따라 소비자들이 해당제품의 디자인에 대해 평가하는 메커니즘을 밝힐 필요성이 존재하며, 적절한 가치를 전달하기 위해 디자인을 평가할 수 있는 모형이 필요하다. 디자인과 관련한 기존 연구들은 소비자들의 인지와 가치 부분에 초점을 맞추어 연구를 하였지만, 제품 속성 자체에 대한 부분은 고려하지 않은 경향이 있으며, 제품이 갖고 있는 객관적인 속성들에 따라 소비자들의 인지가 변화하는 과정과 최종적으로 느끼는 가치에 대한 메커니즘을 밝힌 연구는 부재한 것으로 나타났다. 따라서 본 연구는 스마트폰 제품이 갖고 있는 객관적 속성인 제품 속성과 객관적 속성을 통해 느끼는 소비자들의 인지, 가치에 대해 평가할 수 있는 메커니즘을 설계하고, 이를 평가할 수 있는 3단계 디자인 평가 모형을 제시하려 한다. 3단계 디자인 평가 모형은 제품 속성, 인지 속성, 소비자 가치까지 모든 단계를 고려한 정량화된 모형으로 스마트폰 분야만이 아닌 사용자경험 분야에 전반적으로 적용 가능할 것으로 기대하며, 기업이 갖고 있는 소비자 데이터와 결합한다면, 특정 소비자층을 겨냥한 제품 생산 및 설계가 가능한 지능형 디자인 가치 평가 모형으로 발전할 수 있을 것으로 예상한다.