Evaluation of Indoor Environmental Factors in Office Building with Underfloor Air-Conditioning (UFAC) System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.36-45
    • /
    • 2001
  • During the last decade, an increasing interest in Underfloor Air-Conditioning (UFAC) systems has emerged. The purpose of this paper is to evaluate the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. The physical measurements and the Interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation (POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey .

  • PDF

마이크로파 위성관측과 모델 재분석에서 조사된 전지구에 대한 하부 성층권 온도의 추세 (Global Temperature Trends of Lower Stratosphere Derived from the Microwave Satellite Observations and GCM Reanalyses)

  • 유정문;윤선경;김규명
    • 한국지구과학회지
    • /
    • 제22권5호
    • /
    • pp.388-404
    • /
    • 2001
  • 하부 성층권 온도의 추세에 대한 위성관측과 모델 결과들의 상대적인 정확성을 평가하기 위하여 두 종류의 위성관측 MSU 채널 4(57.95GHz) 밝기온도 자료들과 1981${\sim}$1993년 기간의 두 종류의 대순환 모델(ECMWF and GEOS) 재분석 자료들을 시계열 회귀분석으로 상호 비교하였다. 1980${\sim}$1999년 기간의 위성자료는 이 연구에서 유도된 직하점 MSU4와 여러 주사각에서 유도된 SC4(Spencer and Christy, 1993)이다. 위 기간에 전지구에 대한 MSU 하부 성층권 온도는 화산폭발과 관련된 냉각화 경향(-0.35K/decade)을 보였으며, 이러한 경향은 육지보다 해양에서 1.2배 컸다. 자료들의 공통 기간(1981${\sim}$1993년)에 대한 하부 성층권 온도의 아노말리는 두 종류 관측자료와 GEOS에서 전지구적으로 냉각화 경향(-0.14${\sim}$-0.42K/decade)을 보였으나, ECMWF는 북반구를 제외하고 온난화(0.06K/decade)를 보였다. 온도 연주기는 SC4를 제외하고 다른 세 종류 자료에서 유사한 위상과 함께 현저하였다. 온도 추세에 대한 95%신뢰도 조사에서 MSU 채널 4의 하부 성층권 온도에 대한 신뢰도가 채널 2(53.74GHz)의 중간 대류권 온도보다 더 낮았다. 또한 두 기층 사이의 온도 추세 감율이 북반구 육지에서 가장 컸다. MSU4에 대한 SC4 및 모델 재분석 결과들의 상관은 전지구의 경우에 SC4(r=0.96)에서 가장 높았고, ECMWF(r=0.61)에서 가장 낮았다. 한반도의 경우에는 GEOS에서 가장 높았고(r=0.88), ECMWF에서 가장 낮았다(r=0.73). MSU4에 대한 SC4, ECMWF의 상관은 아열대 제트류가 위치하는 $30^{\circ}$ 위도대에서 낮았으나(r<0.6) 그 외의 지역에서는 대체로 높았다(r>0.6). 한반도 부근에서 하부 성층권 온도의 냉각화 경향은 모든 자료에서 공통적으로 나타났다. 이러한 추세는 SC4(-0.82K/decade)에서 가장 컸으며, MSU4(-0.38K/decade), GEOS(-0.28K/decade), ECMWF(-0.07K/decade) 순으로 나타났다.

  • PDF

하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교 (The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제42권5호
    • /
    • pp.22-30
    • /
    • 2014
  • 조경용 녹음수가 하절기 옥외공간에서 인간이 느끼는 열쾌적성에 미치는 효과를 객관적으로 검증하기 위하여 수형이 서로 다른 미국참나무, 배롱나무, 참느릅나무 등 세 종의 수목를 선정하여 일사차단율과 평균복사온도 저감 효과를 비교분석하였다. 또한, 주기적으로 수관부 사진을 촬영하여 수관부의 변화특성도 비교 검토하였다. 일사량과 건구온도, 흑구온도를 현장에서 자동으로 계측 기록할 수 있는 시스템을 구축하여 각 수목의 수관 하부에 지면으로부터 1.1m 위치에 설치하고, 2013년 4월 1일부터 동년 11월 30일까지 매 분 단위로 기록될 수 있도록 설정하였다. 수관의 천공차폐율 분석결과, 비교적 일정한 상태를 유지한 것으로 나타난 2013년 6월 1일부터 동년 8월 30일까지의 자료 중, 우천과 이상 기상일 자료를 제외한 오전 10시에서 오후 2시까지의 자료를 통계 분석에 이용하였다. 10분 단위 평균값으로 환산된 총 6,640건의 흑구온도와 건구온도를 바탕으로 평균복사온도를 환산하였으며, 이를 각 시험구의 일사량과 비교 분석하였다. 분석 대상 기간 중 미국참나무와 배롱나무, 참느릅나무 수관부의 평균 천공차폐율은 각각 99%, 98%, 97%였으며, 각 수관하부에 도달한 평균 태양 복사량은 $106W/m^2$, $163W/m^2$, $202W/m^2$로 대조구의 $823W/m^2$와 비교했을 때, 최소 75%이상이 차단된 것으로 나타났다. 또한, 평균복사온도의 경우, 각각 $30.34^{\circ}C$, $33.34^{\circ}C$, $34.77^{\circ}C$로 계산되어 대조구의 $46.0^{\circ}C$와 비교했을 때, 적게는 $10^{\circ}C$에서 많게는 $16^{\circ}C$까지 수목의 수관부에 의해서 저감된 것으로 나타났다. 일사량과 평균복사온도의 관계를 회귀분석한 결과, 매우 밀접한 선형관계를 형성하고 있었으며, 설명력도 매우 높게 분석되었다. 결론적으로 본 연구를 통해서 하절기 옥외공간에서 녹음수의 수관은 일사량의 상당부분을 차단함으로써 인간이 체감하는 열쾌적성을 개선하는데 매우 중요한 역할을 하고 있다는 점을 객관적으로 확인할 수 있었다. 따라서, 옥외공간에 더 많은 녹음수와 숲을 조성하여 그늘 지역을 증가시킴으로써 인간의 하절기 옥외활동에 부정적 영향을 주고 있는 불필요한 열에너지를 현격하게 저감시켜 쾌적한 열환경을 효과적으로 조성할 수 있을 것이다.

Investigation of school building microclimate using advanced energy equipment: Case study

  • Alwetaishi, Mamdooh;Alzaed, Ali;Sonetti, Giulia;Shrahily, Raid;Jalil, Latif
    • Environmental Engineering Research
    • /
    • 제23권1호
    • /
    • pp.10-20
    • /
    • 2018
  • Buildings are responsible of major energy consumption globally. In addition, they are linked to thermal comfort. The need to provide comfort becomes more crucial in schools as they are the place where students learn, and develop their skills. This research aims to investigate the energy responsiveness of new and traditional school building design, where major variation in form, amount of external walls and glazing are different. The research focused on indoor microclimate condition of selected schools in the city of Jeddah where the climate is hot and humid using advanced tools for monitoring. The research uses advanced energy equipment to measure several aspects such as floor temperature, roof temperature, globe temperature and other factors which can lead to predictable thermal comfort of users. The findings suggest that a larger area of glazing shielded from sunlight has a greater influence on both indoor condition and general thermal sensation. The finding also suggests that the glazing ratio is a major contributor on indoor thermal pattern which can result in an increase in temperature profile between from $7-10^{\circ}C$. The findings of this research can assist in the improvement in the design of the prototype school building in hot and humid climate.

고온.고압용 벨로우즈 실 밸브의 유동 특성 및 열응력 해석 (Thermal Stress Analysis and Flow Characteristics of a Bellows-Seal Valve for High Pressure and Temperature)

  • 김광수;이종철;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제8권6호
    • /
    • pp.40-46
    • /
    • 2005
  • Because of design and manufacturing costs, it is important to predict an expected life of bellows with component stresses of bellows as its design factors and material characteristics. In this study, numerical analyses are carried out to elucidate the thermal and flow characteristics of the bellows-seal gate and globe valves for high temperature (max. $600^{\circ}C$) and for high pressure (max. $104 kgf/cm^2$) conditions. Using commercial codes, FLUENT, which uses FVM and SIMPLE algorithm, and ANSYS, which uses FEM, the pressure and temperature fields are graphically depicted. In addition, when bellows have an axial displacement, thermal stress affecting bellows life is studied. The pressure and temperature values obtained from the flow analyses are adopted as the boundary conditions for thermal stress analyses. As the result of this study, we got the reasonable coefficients for valve and thermal stress for bellows, compared with existing coefficients and calculated values.

도시의 기온 분석을 통한 지역별 열 환경 특성 해석과 동·하절기 계절 간 비교연구 (Comparison Study on Thermal Environment Characteristics in Each Region and the Seasons of Summer and Winter Through Air Temperature Analysis in Urban Areas)

  • 최동호;이부용
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.83-93
    • /
    • 2012
  • This study is to perform the effect of urbanization in urban and suburban districts, and to identify regional characters of climate according to the analysis of slope at rise, and descent of temperature and globe temperature, correlation between seasonal temperature analysis, and calculation of degree hour. According to this study, the result is summarized as follows. (1) The average temperature, rated from high to low, consists of residential area, Daegu weather station, intracity, green belt, water-front green belt, and suburban. (2) At the rise and descent of temperature, the result of the slope change of in each point may be one of the useful indexes to be able to perform the regional unique thermal characteristic, including the seasonal urbanization. (3) Although there is a difference between the surface of the earth and ambient environment. The result of the correlation of temperature between summer and winter is that temperature slope in urban districts was higher than in suburban districts, and the difference of slope was unvaried among the four observations in the same city region. (4) To show objectively, regional thermal characteristics in urban and suburban districts, the exponentiation of winter degree hour and summer degree hours were checked. The result of the exponentiation is that the more artificial a region, the lower index.

풍력발전용 복합소재 블레이드의 적외선 열화상 검사를 이용한 신뢰성 검증 (A Study on Reliability Validation by Infrared Thermography of Composite Material Blade for Wind Turbine Generator)

  • 강병권;남문호;임익성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권3호
    • /
    • pp.176-181
    • /
    • 2014
  • In these days, new and renewable energy is getting popular around globe and wind power generator is one of the renewable energy. In this study, we conducted a study on defect detection of composite material blade for wind power generator by applying active infrared thermography and produced a defect test piece by applying composite material used for blade of wind power generator. An infrared thermal camera and 2 kW halogen lamp are used for the purpose of research as equipments. Also, we analyzed temperature characteristic by using infrared thermal camera after checking a heat source on a test piece and found effectiveness of infrared thermography to blade of wind power generator by detecting defects resulting from temperature difference of a test piece, which eventually improve the safety and reliability of the composite material blade.

보건기상정보 제공을 위한 폭염특보 운영현황 및 개선방안 조사 (Investigation of Operation and Improvement for Heat Watch Warning System to Provide Health-Weather Information)

  • 황미경;강윤희;김성민;김유근
    • 한국환경과학회지
    • /
    • 제28권2호
    • /
    • pp.277-285
    • /
    • 2019
  • Heat watch warning systems are operating in Korea and several other countries (China, the United Kingdom, France, the United States, Germany, Australia, and Japan). The heat wave indices used in this system are the heat index, perceived temperature, the wet bulb globe temperature, and the daily maximum temperature. To improve the heat wave advisory and warning system, some suggestions have been made. The meteorological-health index (i.e., indirect index), has especially been proposed in previous studies. This information should be provided not only to vulnerable groups (seniors, infants, and children), but also to outdoor workers who may be particularly exposed to heat waves. In addition, to have sufficient preemptive response times, the need for an extension of the heat watch warning period was suggested. Finally, the subdivision of administrative units and risk stages was proposed.

On Interesting Correlation between Meteorological Parameters and COVID-19 Pandemic in Saudi Arabia

  • Haq, Mohd Anul;Ahmed, Ahsan
    • International Journal of Computer Science & Network Security
    • /
    • 제22권4호
    • /
    • pp.159-168
    • /
    • 2022
  • The recent outbreak of COVID-19 pandemic cases around the globe has affected Saudi Arabia with around 15, 00,000 confirmed cases within the initial 4 months of transmission. The present investigation analyzed the relationship between daily COVID-19 confirmed cases and meteorological parameters in seventeen cities of KSA. We used secondary published data from the Ministry of Health, KSA daily dataset of COVID-19 confirmed case counts. The meteorological parameters used in the present investigation are temperature, humidity, dew point, and wind speed. Pearson correlation and Spearman rank correlation tests were utilized for data analysis. The incubation period of COVID-19 varies from 1 day to 14 days as per available information. Therefore, an attempt has been made to analyze the effects of meteorological factors with bins of 1, 3, 7, and 14 days. The results suggested that the highest number of correlations (15 cities) was observed for temperature (maximum, minimum, and average) and humidity (12 cities) (minimum and average). The dew point showed relationships for 7 cities and wind showed moderate correlations only for 2 cities. The study results might be useful for authorities and stakeholders in taking specific measures to combat the Covid-19 pandemic.

1904년 이래의 부산 기후 변동성 및 생활기상지수들의 기후변화 특성 연구 (A Study on Characteristics of Climate Variability and Changes in Weather Indexes in Busan Since 1904)

  • 전하은;하경자;김혜렴
    • 대기
    • /
    • 제33권1호
    • /
    • pp.1-20
    • /
    • 2023
  • Holding the longest observation data from April 1904, Busan is one of the essential points to understand the climate variability of the Korean Peninsula without missing data since implementing the modern weather observation of the South Korea. Busan is featured by coastal areas and affected by various climate factors and fluctuations. This study aims to investigate climate variability and changes in climatic variables, extremes, and several weather indexes. The statistically significant change points in daily mean rainfall intensity and temperature were found in 1964 and 1965. Based on the change point detection, 117 years were divided into two periods for daily mean rainfall intensity and temperature, respectively. In the long-term temperature analysis of Busan, the increasing trend of the daily maximum temperature during the period of 1965~2021 was larger than the daily mean temperature and the daily minimum temperature. Applying Ensemble Empirical Mode Decomposition, daily maximum temperature is largely affected by the decadal variability compared to the daily mean and minimum temperature. In addition, the trend of daily precipitation intensity from 1964~2021 shows a value of about 0.50 mm day-1, suggesting that the rainfall intensity has increased compared to the preceding period. The results in extremes analysis demonstrate that return values of both extreme temperatures and precipitation show higher values in the latter than in the former period, indicating that the intensity of the current extreme phenomenon increases. For Wet-Bulb Globe Temperature (effective humidity), increasing (decreasing) trend is significant in Busan with the second (third)-largest change among four stations.