• Title/Summary/Keyword: Globe Design

Search Result 64, Processing Time 0.027 seconds

Design and Implementation of Education Globe System Based on Multimedia (멀티미디어 기반 교육용 지구의 시스템의 설계 및 구현)

  • Cho Soo-Hyun;Kim Young-Hak;Lee Jae-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.4 s.42
    • /
    • pp.127-135
    • /
    • 2006
  • In the existing education using the globe. teaching contents are very simple and the relationship among learning units lacks a little bit because teaching materials are composed individually with the globe. Therefore, in this study, we developed the education glove system based on multimedia that is closely connected with teaching materials and the globe. This system is composed of the globe device and the learning software based on computer control. The globe device rotates itself on its axis as the solar center, and provides more efficient and visual education environment to students through the link between computer and the globe. The learning software provides the multimedia contents such as parallax, climate, culture, and education information about each country, and this software also can simulate the revolution of the earth around the sun. The globe device can be operated in off-line without the computer link. This system was developed by the industry cooperation and was displayed in the principal exhibitions. We have obtained positive results through the exhibitions and will promote the product in the future.

  • PDF

A Study on Structural Design of Cryogenic Miniature Globe Valve using Finite Element Method (유한요소법을 이용한 극저온 미니어쳐 글로브 밸브의 구조설계에 관한 연구)

  • Jeong, Ho-Seung;Cho, Jong-Rae;Kim, Jeong-Hwan;Kim, Jung-Ryul;Park, Jae-Hyoun;Kim, Young-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.343-349
    • /
    • 2007
  • This cryogenic miniature globe valve is used to transfer the liquified natural gas which temperature is $-169^{\circ}C$, supplied pressure is 30bar(3.0MPa). In the present work the temperature distribution and thermal deformation is calculated numerical the FE method is useful to predict the thermal matter of cryogenic miniature globe valve. For this reason, to optimum design of the cryogenic miniature globe valve the analysis of the parameter about bonnet has been studied. It's used 3-D modeling to analyze cryogenic globe valve, which is 1/2". Numerical study used 3-D modeling makes a decision of efficient process of product before producing in the factory. A commercial software(ANSYS 10.0) is used in the structural analysis for cryogenic globe valve.

Indoor Environmental Condition by Existing Front Balcony in Apartment House during Winter (아파트의 전면발코니 개조여부에 따른 겨울철 실내환경 측정비교)

  • Choi, Yoon-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.267-270
    • /
    • 2005
  • The purpose of this study was to make clear the indoor environmental efficiency of front balcony 'in apartment houses during winter. The field measurements of indoor environmental elements were carried out at an ordinary house with an existing front balcony and a house renovated the front balcony into the living room. The measurements in two-subject houses were taken on simultaneously the 20$^{th}$ ${\sim}$ 21$^{th}$ of January 2003. As results, the averages indoor temperature in the ordinary house and the renovated house were same as 23.6${\circ}$C, and the averages globe temperature in two houses were same as 23.7${\circ}$C. But, estimated heating time of the renovated house was longer than that of the ordinary house. The daily ranges of indoor temperature and globe temperature in the renovated house were wider than the ordinary house. The daily ranges of indoor temperature and globe temperature in the renovated house was longer than that of the ordinary house. The uniformity ratio range of daylight in the ordinary house were calculated at 1/3.4${\sim}$1/6.2, but those of the renovated house were 1/6${\sim}$1/16.2. Therefore. it was found that indoor temperature, globe temperature and uniformity ratio of daylight in the ordinary house maintained more constant than the renovated house by green house effect and earning effect of front balcony.

  • PDF

New Seat Design and Finite Element Analysis for Anti-Leakage of Globe Valve (글로브 밸브의 누설방지를 위한 시트 설계 및 유한요소해석)

  • Lee, Sung Ho;Kang, Gyeong Ah;Kwak, Jae-Seob;An, Ju Eun;Jin, Dong Hyun;Kim, Byung Tak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.1
    • /
    • pp.81-86
    • /
    • 2016
  • The valves used to control or shut off the flow through a pipeline can be divided into many different types, including gate valves, globe valves, and check valves. Globe valves, in particular, have excellent properties, and because they can easily control the flow under high-pressure conditions, they are generally used in LNG ship and steam pipelines. In this paper, a method for changing the shape of a seat was suggested to solve the valve leakage problem from a structural perspective. In addition, the stress distribution and directional deformation were compared for each model. The suggested models were thus validated, and the optimized seat structure, which includes a self-supporting capability for decreasing the amount of leakage, was determined.

Analysis of Experiments for 'Measuring the size of Earth in 8th Science Textbooks

  • Chae, Dong-Hyun
    • Journal of The Korean Association For Science Education
    • /
    • v.30 no.7
    • /
    • pp.901-907
    • /
    • 2010
  • The purpose of this study is to analyze methods for measuring the size of the Earth, put forth in 6 different Korean 8th grade science textbooks. The research questions are as follows: 1) Do they adequately map out the experiments for measuring the size of the earth by using the concept of the sun's altitude? 2) Do they reduce the size of the sun like as the Earth is similarly downsized to the globe? 3) Do they suggest the precise experimental conditions for selecting two equal longitudinal spots for measuring the size of the earth? 4) Do they design adequate experiments for exact measurement? 5) Do they offer a proportional expression for seeking the size of globe which is easily understood by students? 6) Do they develop experiments to measure actual size of the earth? Four graduate students and one researcher took part in this study. All conditions were unanimously agreed upon by the participants. The results are as follows. First, one publishing company must include the concept of the sun's altitude to accurately measure the size of the Earth. However, some textbooks fail to mention this. As such, the concept of the sun's altitude must be introduced to accurately measure the size of the Earth. Second, a reduced size globe is used as the actual earth so; the sun should be factored in with a reduced light value. Third, you have to lay a stress on two points at the same longitude. In other words, a shadow located at the same longitude from two randomly selected points. Most textbooks mention two points at the same longitude but two of them design the experiment with a shadow at the same longitude. Fourth, we need a method to precisely measure the angle between a stick and its shadow. The angle between the stick and the tip of its shadow is the sun's altitude difference. Fifth, we need to present more specific proportional expressions for calculating the size of the globe. Only 3 out of the 6 texts employed a proportional expression. Sixth, we need to calculate the size of the earth by accurately presenting the scale of the globe to attain the goal of the experiment. Two of the texts analyzed, designed the experiment for the purpose of calculating the size of the globe. Three of the texts designed their experiments to calculate the radius of globe which is not even relevant to the purpose of experiment.

A Study on the Flow Characteristics inside a Glove Valve for Ships (선박용 글로브 밸브의 유동특성에 관한 연구)

  • Bae, Ki-Hwa;Park, Jea-Hyoun;Kang, Sang-Mo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.110-118
    • /
    • 2008
  • It is essential for the valid design of a marine flow-control valve to exactly know its flow characteristics. The present study has numerically investigated the flow characteristics inside a marine throttle-type globe valve using a kind of commercial CFD code, CFX10.0, with an adoption of the SST (Shear-Stress Transport) turbulence model. To validate the numerical approach, the flow coefficients are compared with the experimental ones. Results show that the globe valve is effective in the control of flow rate according to the opening ratio in case of the forward-direction flow, whereas it is effective in the flow shutoff in case of the reverse-direction flow. Around the inlet of the valve, a recirculation region is formed due to the blunt body shape, the turbulence intensity becomes strengthened and then an abrupt pressure loss occurs.

Dynamic Modeling and Test of the Air-Operated Valve (공기구동밸브의 동특성 모델링 및 시험)

  • Cho T.D.;Lee H.Y.;Yang S.M.;Yang S.B.;Kwon B.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1808-1811
    • /
    • 2005
  • The prediction of AOV(air-operated valve) performance is normally evaluated by the allowable opening thrust margin for the opening and closing stroke. However, it is not easy to carry out the dynamic test measurement for all the valves in the nuclear power plant due to the safety and operating conditions. The analysis of the available and required thrust for the valve is simulated as an alternate method to turn around this obstacle. The required air pressures to the stem displacement are discussed for differential valve pressure obtained by experiment. The result of the simulation is compared with that of the experiment. SIMULINK in MATLAB was used for the simulation and the results show good agreement with the actual test carried out with Fisher globe valve.

  • PDF

an Analysis of the Variation on the Impedance Characteristic according to Effective Area of Globe Control Valve at Low Frequency Perturbation (저주파 압력섭동에서 글로브 제어밸브의 유효 단면적에 따른 임피던스 특성 변화 해석)

  • Park, Seungsoo;Yoon, Woongsup;ohm, Wonsuk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.718-723
    • /
    • 2017
  • In this paper, Analytical study is carried out on the impedance characteristics of the globe control valve, which is mainly used for thrust control in liquid rockets, according to the effective area at low frequency perturbation. The impedance tends to increase according to effective area and the cause of impedance characteristic change through flow field visualization is investigated. In the future, the information on the change in the impedance characteristics of the control valve can be used to obtain the impedance of the supply system and it can be utilized to predict pogo phenomenon as well as design accumulator and orifice to reduce the pogo phenomenon.

  • PDF

An Experimental Study on Difference of Thermal Sensation by Radiant Floor Heating (바닥난방 복사열에 의한 온열감 차이에 대한 실험연구)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Jeong, Youn-Hong
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.65-71
    • /
    • 2007
  • The purpose of this study was to analyze the difference of thermal sensation by radiant floor heating as ecological design element. The experimental investigations were carried out in climate chamber, and subjects were 34 college-age females in good health. The experimental variable was radiant heat by floor heating, and experimental controlled conditions were indoor temperature, relative humidity, and air velocity in climate chamber and clothing value and activity of subjects. The results are as follows. (1) Indoor temperature($21{\pm}0.5^{\circ}C$) in climate chamber were maintained as controlling. Clothing values of the subjects were controlled as average 0.73 clo. In the floor heating-off, globe temperature was average $23.2^{\circ}C$(22.4~24.1), but in the floor heating-on, globe temperature was average $24.8^{\circ}C$(23.0~25.5). (2) In the floor heating-off, thermal sensation rating was average -1.03(slightly cool), in the floor heating-on, thermal sensation rating was average +1.03(slightly warm). (3) There were the differences of thermal sensation by radiant floor heating although indoor temperatures were maintained in an equal state. (4) The thermal sensation rating was tending upward according as the globe temperature was getting higher.

Structure and Conceptual Design of a Water-Hammering-Type Honsang for Restoration

  • Lee, Yong-Sam;Kim, Sang-Hyuk
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.2
    • /
    • pp.221-232
    • /
    • 2012
  • We analyzed the manufacturing procedure, specifications, repair history, and details of celestial movements of the water-hammering type $Honsang$ (celestial globe). Results from our study on the remaining $Honsangs$ in China and Japan and on the reconstruction models in Korea were applied to our conceptual design of the water-hammering type $Honsang$. A $Honui$ (armillary sphere) and $Honsang$ using the water-hammering method were manufactured in $Joseon$ in 1435 (the 17th year of King $Sejong$). $Jang$ $Yeong-Sil$ developed the $Honsang$ system based on the water-operation method of $Shui$ $y{\ddot{u}}n$ $i$ $hsiang$ $t'ai$ in China. Water-operation means driving water wheels using a water flow. The most important factor in this type of operation is the precision of the water clock and the control of the water wheel movement. The water-hammering type $Honsang$ in $Joseon$ probably adopted the $Cheonhyeong$ (天衡; oriental escapement device) system of $Shui$ $y{\ddot{u}}n$ $i$ $hsiang$ $t'ai$ in China and the overflow mechanism of $Jagyeongnu$ (striking clepsydra) in $Joseon$, etc. In addition to the $Cheonryun$ system, more gear instruments were needed to stage the rotation of the $Honsang$ globe and the sun's movement. In this study, the water-hammering mechanism is analyzed in the structure of a water clock, a water wheel, the $Cheonhyeong$ system, and the $Giryun$ system, as an organically working operation mechanism. We expect that this study will serve as an essential basis for studies on $Heumgyeonggaknu$, the water-operating astronomical clock, and other astronomical clocks in the middle and latter parts of the $Joseon$ dynasty.