• Title/Summary/Keyword: Global equivalence ratio

Search Result 27, Processing Time 0.021 seconds

환기 조건에 따른 화재거동 연구 (On the Fire Behavior Due to the Ventilation Condition in the Fire Compartment)

  • 김성찬
    • 대한기계학회논문집B
    • /
    • 제32권5호
    • /
    • pp.367-373
    • /
    • 2008
  • A series of fire experiments has been conducted to provide an improved understanding of the fire structure of under-ventilated compartment fires. A comprehensive and quantitative assessment of gaseous species from the fire was made in the upper layer of fire in a 40 % reduced scale ISO 9705 fire compartment. The global equivalence ratio (GER) concept was used to characterize the fire behavior for various fire sizes, fuel types and ventilation conditions. The oxygen concentration in the upper layer reached to zero near the global equivalence ratio of $0.4{\sim}0.6$ while the carbon monoxide concentration increases with increasing the global equivalence ratio. Classification parameters of ISO19706 were also compared with the reduced scale experimental data for under ventilation fire.

실제 규모의 구획화재에서 총괄당량비와 화재특성의 상관관계에 관한 실험적 연구 (An Experimental Study on Relationship Between Global Equivalence Ratio and Fire Characteristics in Full-Scale Compartment Fires)

  • 황철홍;박충화;고권현
    • 한국연소학회지
    • /
    • 제15권3호
    • /
    • pp.32-39
    • /
    • 2010
  • An experimental study was conducted to investigate the relationship between global equivalence ratio(GER) and fire characteristics in an ISO 9705 room. Heptane fuel was burned with different fuel flow rates and doorway widths in order to force the room to be placed in different GER conditions. It was observed that after the onset of under-ventilated fire conditions, temperature and unburned fuel components such as CO and soot increased with increasing heat release rate (HRR), regardless of the doorway width. From the analysis of local mixture fraction, it was reconfirmed that the inclusion of soot production in the product composition was very important to predict accurately the chemical conditions inside the compartment, particularly for the under-ventilated fire conditions. In addition, the local equivalence ratio (LER) was directly proportional to the GER with a unit gradient regardless of doorway width when the soot production was included in the chemical products. This finding provided an important potential that the GER could be used to correlate the local thermal and chemical environment measured at the upper layer of a full-scale enclosure when soot was included.

희박 예혼합 덤프 연소기에서 OH 자발광을 이용한 열 방출에 관한 실험적 연구 (Experimental Study on Heat Release in a Lean Premixed Dump Combustor using OH Chemiluminescence Images)

  • 문건필;이종호;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1146-1151
    • /
    • 2004
  • Measurements of OH chemiluminescence in an atmospheric pressure, laboratory-scale dump combustor at equivalence ratios ranging from 0.63 to 0.89 were reported. The signal from the first electronically excited state of OH to ground state was detected through a band-pass filter with an ICCD. The objectives of this study are two: One is to see the effects of equivalence ratio on global heat release rate and local Rayleigh index distribution. To get the local Rayleigh index distribution, the line-of-sight images were inverted by tomographic method, such as Abel de-convolution. Another aim is to investigate the validity of using OH chemiluminescence acquired with an ICCD as a qualitative measure of local heat release. For constant inlet velocity and temperature, the overall intensities of OH emission acquired at different equivalence ratio showed periodic and higher value at high equivalence ratio. OH intensity averaged over one period of pressure increased exponentially with equivalence ratio. Local Rayleigh index distribution clearly showed the region of amplifying or damping the combustion instability as equivalence ratio increased. It could provide an information/insights on active control such as secondary fuel injection. Finally, local heat release rate derived from reconstructed OH images were presented for typical locations.

  • PDF

연료 종류 및 당량비에 따른 Flame Spray 화염장의 열-유동 특성 연구 (Thermal and Flow Characteristics of Fluid with Fuel Type and Equivalence Ratio in Flame Spray Process)

  • 이재빈;김대윤;신동환;이성혁
    • 한국분무공학회지
    • /
    • 제18권4호
    • /
    • pp.202-208
    • /
    • 2013
  • The present study aims to investigate the flow characteristics with respect to fuel type and equivalence ratio in the flame spray coating process. The flame spray flow is characterized by much complex phenomena including combustion, turbulent flows, and combined heat transfer. The present study numerically simulated the flam spray process and examined the gas dynamics involving combustion, gas temperature and velocity distributions in flame spray process by using commercial computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). In particular, we studied the effect of fuel type and equivalence ratio on thermal and flow characteristics which could substantially affect the coating performance. From the results, it was found that the gas temperature distributions were varied with different fuels because of reaction times were different according to the fuel type. The equivalence ratio also could change the spatial flame distribution and the characteristics of coated layer on the substrate.

A Modeling Study of Local Equivalence Ratio Fluctuation in Imperfectly Premixed Turbulent Flames

  • Moon, Hee-Jang
    • Journal of Mechanical Science and Technology
    • /
    • 제18권8호
    • /
    • pp.1479-1489
    • /
    • 2004
  • The effect of fluctuation of Equivalence Ratio (ER) in a turbulent reactive field has been studied in order to check the global combustion characteristics induced by the local fluctuation. When the flow is premixed on a large scale, closer examination on a small scale reveals that local fluctuations of ER exist in an imperfectly premixed mixture, and that these fluctuations must be considered to correctly estimate the mean reaction rate. The fluctuation effect is analyzed with DNS by considering the joint PDF of reactive scalar and ER, followed by modeling study where an extension of stochastic mixing models accounting for the ER fluctuation is reviewed and tested. It was found that models prediction capability as well as its potential is in favor to this case accounting the local ER fluctuation. However, the effect of local fluctuation did not show any notable changes on the mean global characteristics of combustion when statistical independence between the reactive scalar and ER field is imposed, though it greatly influenced the joint PDF distribution. The importance of taking into account the statistical dependency between ER and combustible at the initial phase is demonstrated by testing the modeled reaction rate.

화학발광을 활용한 연소계측 연구동향 (Recent Research Works on Chemiluminescence as Measures of Combustion Characteristics)

  • 서성현;문인상
    • 한국추진공학회지
    • /
    • 제18권1호
    • /
    • pp.73-84
    • /
    • 2014
  • 본 논문에서는 화학발광 계측을 통한 연소화염의 당량비, 열방출율과 같은 물리량 판단에 대한 최신 연구결과를 정리 분석하였다. 현대의 연소장치는 연소의 동적 안정성 증대 및 공해물질 배출억제를 위해 세밀한 제어가 필요하다. 화학발광 세기 계측을 통한 물리량 파악은 그 적용에 있어서 많은 상대적 장점을 지니고 있다. 그러나 본 방법은 당량비, 연소압력, 입구온도, 난류세기, 연료 종류 등에 의해 많은 영향을 받는다. 연구결과를 종합하면, 메탄/공기 예혼합 화염에서 $CH^*/OH^*$가 연료 과농 조건을 제외하고 당량비와 밀접한 관계가 있다. 또한 넓은 공간에서 측정된 $OH^*$, $CH^*$ 신호는 전체 열방출율과 비례관계를 갖는 것으로 판단된다.

상호작용하는 대향류 메탄 및 수소 예혼합화염에서 당량비 조건에 따른 상호작용 모드 변화 (Interaction Mode Change According to the Equivalence Ratios in the Interacting Methane and Hydrogen Counterflow Premixed Flames)

  • 박지웅;오창보
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.13-16
    • /
    • 2012
  • The interaction between methane and hydrogen premixed flames with the different equivalence ratio and global strain rate was investigated numerically in one-dimensional counterflow field. The OPPDIF code and GRI-v3.0 were used to simulate the interacting flames. Overall trends in the maximum heat release rates of $CH_4{^-}$ and $H_2$-side flame were examined with the variation of $a_g$. The interaction mode of the flames were classified according to the equivalence ratios and Lewis numbers of each flame and global strain rate.

  • PDF

희박 예혼합 덤프 연소기에서 OH 자발광을 이용한 열 방출에 관한 실험적 연구 (Experimental Study on Heat Release in a Lean Premixed Dump Combustor Using OH Chemiluminescence Images)

  • 문건필;이종호;전충환;장영준
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1368-1375
    • /
    • 2004
  • Measurements of OH chemiluminescence in an atmospheric pressure, laboratory-scale dump combustor at equivalence ratios ranging from 0.63 to 0.89 were reported. The signal from the first electronically excited state of OH to ground state was detected through a band-pass filter with an ICCD. The objectives of this study are two: One is to see the effects of equivalence ratio on global heat release rate and local Rayleigh index distribution. To get the local Rayleigh index distribution, the line-of-sight images were inverted by tomographic method, such as Abel do-convolution. Another aim is to investigate the validity of using OH chemiluminescence acquired with an ICCD as a qualitative measure of local heat release. For constant inlet velocity and temperature, the overall intensities of OH emission acquired at different equivalence ratio showed periodic and higher value at high equivalence ratio. OH intensity averaged over one period of pressure increased exponentially with equivalence ratio. Local Rayleigh index distribution clearly showed the region of amplifying or damping the combustion instability as equivalence ratio increased. It could provide an information/insights on active control such as secondary fuel injection. Finally, local heat release rate derived from reconstructed OH images were presented fur typical locations.

희박 예혼합 모형 가스터빈 연소기의 OH 자발광을 이용한 연소불안정성에 대한 실험적 연구 (Experimental Study on Combustion Instability Mechanism in a Lean Premixed Model Gas Turbine Combustor using OH Chemiluminescence Images)

  • 이재호;이종호;장영준;전충환
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.259-264
    • /
    • 2005
  • 연소불안정과 밀접한 관련이 있는 열방출의 측정은 연소불안정을 제어하는데 매우 중요하다. 따라서 본 연구에서는 희박예혼합연소에서 반응영역의 위치와 전체, 국소 열방출률의 지표로 많이 사용되는 $OH^{\ast}$ 이미지를 ICCD를 이용해 취득하였다. 본 연구의 목적은 당량비가 전체 열방출률과 국소 레일라이 지수 분포에 미치는 영향을 알아보는 것이다. 국소 레일라이 지수 분포는 선적분된 이미지를 아벨 역변환 시켜서 화염의 중앙 단면 정보를 통해 얻을 수 있었다. 각 당량비 조건에서, 한 주기 동안의 열방출의 평균값은 당량비가 증가함에 따라 지수 함수적으로 증가하였다. 국소 레일라이 지수 분포 결과로부터, 연소불안정을 증폭시키거나 소멸시키는 영역을 분명히 알 수 있었다. 이것은 넓은 당량비 조건에 대한 화염구조와 연소불안정 영역에 대한 통찰력을 제공한다.

  • PDF

EGR 시스템을 적용한 린-리치 연소시스템의 공해물질 배출 특성 연구 (The Pollutant Emissions Characteristics of Lean-Rich Combustion System with Exhaust Gas Reciculation)

  • 오휘성;유병훈;김종현;이창언
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.233-234
    • /
    • 2014
  • Lean-rich combustion system was composed both fuel-lean and fuel-rich flame at once. Each of fuel-lean and fuel-rich combustion types to reduce Thermal $NO_x$ and obtain flame stability. This study was confirmed a stability of flame through variation of flame shape that EGR was applied and compared the emission characteristics of EGR lean-rich combustion system to normal premixed combustion system at real condition to review a utility of the system. As a result, emission index of $NO_x$ and CO generated from EGR lean-rich combustion system at global equivalence ratio is 0.85 just half level($NO_x$ 0.31 g/kg, CO 0.08g/kg) compared to the amount generated from normal premixed combustion system at equivalence ratio is 0.78.

  • PDF