• 제목/요약/키워드: Glide path preparation

검색결과 17건 처리시간 0.028초

Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구 (Efficiency of the nickel-titanium rotary instruments for glide path preparation: in-vitro preliminary study)

  • 김현철;곽상원;하정홍
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.688-694
    • /
    • 2017
  • Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.

  • PDF

Comparison of the ability of Reciproc and Reciproc Blue instruments to reach the full working length with or without glide path preparation

  • Adiguzel, Mehmet;Tufenkci, Pelin
    • Restorative Dentistry and Endodontics
    • /
    • 제43권4호
    • /
    • pp.41.1-41.7
    • /
    • 2018
  • Objectives: The purpose of the present study was to compare the mean preparation times and frequency with which Reciproc and Reciproc Blue instruments reached the full working length in mandibular molars, with or without glide path preparation. Materials and Methods: Previously untreated mesiobuccal and mesiolingual canals with completely formed apices were randomly divided into 6 groups (n = 50) depending on the usage of Reciproc (RC; VDW), Reciproc Blue (RC Blue; VDW), C-Pilot (CP; VDW), and R-Pilot (RP; VDW) files: RC, RC Blue, RC + C-Pilot (RC-CP), RC-Blue + C-Pilot (RC Blue-CP), RC+R-Pilot (RC-RP), and RC Blue + R-Pilot (RC Blue-RP). A glide path was prepared using the hand-operated C-Pilot or the machine-operated R-Pilot instruments, respectively. The ${\chi}^2$ test, analysis of variance, and the Tukey post hoc test were used for statistical comparisons. Results: No statistically significant differences were observed in the distribution of the frequency of reaching the full working length in the RC (94%), RC Blue (88%), RC-CP (94%), RC Blue-CP (90%), RC-RP (96%), and RC Blue-RP (92%) groups (p > 0.05). Conclusions: Preparation of a glide path did not have a significant effect on reaching the full working length using these systems.

Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

  • Yared, Ghassan
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.85-90
    • /
    • 2015
  • This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickeltitanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating motion with very small angles. Hand files are not used regardless of the complexity of the canal anatomy. It also allows achieving predictable results in canal negotiation and glide path creation in challenging canals without the risk of instrument fracture.

Influence of a glide path on the dentinal crack formation of ProTaper Next system

  • Turker, Sevinc Aktemur;Uzunoglu, Emel
    • Restorative Dentistry and Endodontics
    • /
    • 제40권4호
    • /
    • pp.286-289
    • /
    • 2015
  • Objectives: The aim was to evaluate dentinal crack formation after root canal preparation with ProTaper Next system (PTN) with and without a glide path. Materials and Methods: Forty-five mesial roots of mandibular first molars were selected. Fifteen teeth were left unprepared and served as controls. The experimental groups consist of mesiobuccal and mesiolingual root canals of remaining 30 teeth, which were divided into 2 groups (n = 15): Group PG/PTN, glide path was created with ProGlider (PG) and then canals were shaped with PTN system; Group PTN, glide path was not prepared and canals were shaped with PTN system only. All roots were sectioned perpendicular to the long axis at 1, 2, 3, 4, 6, and 8 mm from the apex, and the sections were observed under a stereomicroscope. The presence/absence of cracks was recorded. Data were analyzed with chi-square tests with Yates correction. Results: There were no significant differences in crack formation between the PTN with and without glide path preparation. The incidence of cracks observed in PG/PTN and PTN groups was 17.8% and 28.9%, respectively. Conclusions: The creation of a glide path with ProGlider before ProTaper Next rotary system did not influence dentinal crack formation in root canals.

Reciprocating 파일 시스템에서 Glide Path가 근관만곡도 유지에 미치는 영향 (The Effect of Glide Path on Canal Centering Ability in Reciprocating File System)

  • 장기철;김진우;조경모;박세희
    • 구강회복응용과학지
    • /
    • 제28권3호
    • /
    • pp.245-252
    • /
    • 2012
  • 본 실험은 왕복 회전 운동을 하는 단일 파일 시스템으로서 Reciproc과 WaveOne을 이용하였으며 glide path를 형성했을 때와 안 했을 때의 근관의 중심 변위율과 만곡도의 감소를 비교하여 새로운 단일 파일 시스템에서 glide path가 근관 성형 후 근관의 형태에 미치는 영향을 연구하였다. 총 40개의 모형 근관에 메틸렌블루 용액을 주입한 후 근관성형 전 이미지를 스캔 하였다. 네 개의 그룹으로 나누어졌으며 그룹 1은 PathFile (Dentsply Maillefer) #1, 2, 3 사용 후 R25 크기의 Reciproc 파일(VDW)을 사용하여 근관 성형하였다. 그룹 2는 PathFile 사용 없이 R25 크기의 Reciproc 파일을 사용하여 근관 성형하였다. 그룹 3은 PathFile #1, 2, 3 사용 후 Primary 크기의 WaveOne 파일 (Dentsply Maillerfer)을 이용하여 근관 성형하였다. 그룹 4는 PathFile 사용 없이 WaveOne 파일을 이용하여 근관 성형하였다. 파일은 모두 21 mm 길이를 사용했다. 각각의 파일을 위한 전기 모터로 Reciproc 파일은 VDW.SILVER motor (VDW), WaveOne 파일은 Waveone endo motor (Dentsply Maillefer)와 PathFile은 X-SMART (Dentsply Maillefer)를 사용하였다. 근관 성형을 마친 모형 근관을 다시 이미지 스캔 하였다. 성형 전, 후의 이미지를 Adobe Photoshop CS 3 (Adobe Systems Incorporated)을 이용하여 중첩하여 평가하였다. 중심 변위율은 Calhoun과 Montgomery에 의해 제안된 다음 공식을 사용하여 계산되었다:CR=|X1-X2|/Y. 실험 결과 근관의 만곡도가 감소하는 치근단 1, 2 mm level에서는 glide path의 형성에 따른 근관의 중심 변화율의 통계학적 유의성이 보이지 않았다. 근관 만곡 부위인 치근단 3, 4, 5 mm level에서는 glide path를 부여한 것이 통계학적으로 유의성 있게 낮은 중심 변위율을 보였다. 치근단 1 mm level에서는 Reciproc 파일이 유의성 있게 낮은 중심 변위율을 보였고, 치근단 1, 6 mm level을 제외한 모든 level에서 WaveOne 파일이 유의성 있게 낮은 중심 변위율을 보였다. 치근단 6 mm level에서는 Reciproc과 WaveOne의 차이는 관찰할 수 없었고 glide path를 형성한 그룹이 형성하지 않은 그룹에 비해 유의성 있게 낮은 중심 변위율을 보였다. 본 실험을 통해 만곡된 근관에서 근관 성형 전 glide path의 형성은 근관의 원래 형태를 유지하는데 필수적이며, 만곡된 근관에서는 WaveOne 파일 시스템의 선택이 근관의 원래 형태를 유지하는데 더 적절할 것으로 생각된다.

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

Effect of repetitive pecking at working length for glide path preparation using G-file

  • Ha, Jung-Hong;Jeon, Hyo-Jin;Abed, Rashid El;Chang, Seok-Woo;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제40권2호
    • /
    • pp.123-127
    • /
    • 2015
  • Objectives: Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods: The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). Results: The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Conclusions: Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals

  • Ha, Jung-Hong;Park, Sang-Shin
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.215-219
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect ($2.796{\pm}0.134$) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files

  • Uslu, Gulsah;Inan, Ugur
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.22.1-22.8
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files. Materials and Methods: Forty-four WaveOne Primary files were used and divided into four groups (n = 11). In the first group (0 WaveOne), the WaveOne Primary files served as a control group and were not used on acrylic blocks. In the 1 WaveOne Group, acrylic blocks were prepared using only WaveOne Primary files, and in the PF+WaveOne group and PG+WaveOne groups, acrylic blocks were first prepared with PathFile or ProGlider NiTi files, respectively, followed by the use of WaveOne Primary files. All the WaveOne Primary files were then subjected to cyclic fatigue testing. The number of cycles to failure was calculated and the data were statistically analyzed using one-way analysis of variance (ANOVA) and the Tukey honest significant difference multiple-comparison test at a 5% significance level. Results: The highest number of cycles to failure was found in the control group, and the lowest numbers were found in the 1 WaveOne group and the PF+WaveOne group. Significant differences were found among the 1 WaveOne, PF+WaveOne, and control groups (p < 0.05). No statistically significant differences were found between the PG+WaveOne group and the other three groups (p > 0.05). Conclusion: Glide path preparation with NiTi rotary files did not affect the cyclic fatigue resistance of WaveOne Primary files used on acrylic blocks.

Comparison of postoperative pain intensity after using reciprocating and continuous rotary glide path systems: a randomized clinical trial

  • Adiguzel, Mehmet;Yilmaz, Koray;Tufenkci, Pelin
    • Restorative Dentistry and Endodontics
    • /
    • 제44권1호
    • /
    • pp.9.1-9.9
    • /
    • 2019
  • Objectives: The aim of this study was to compare postoperative pain intensity after root canal treatment with One G (OG) vs. R-Pilot (RP) files used for glide path preparation. Materials and Methods: Ninety-three single-canaled mandibular premolar teeth with asymptomatic non-vital pulp were randomly assigned into 3 groups (n = 31): OG, RP, or without glide path (WGP). After creating the glide path, the root canals were prepared using sequential Mtwo rotary files to size 30/0.05. One endodontic specialist carried out single-visit endodontic treatment. The patients were asked to rate the severity of postoperative pain on a visual analogue scale at 24, 48, and 72 hours after the visit. They were also asked to record their intake of prescribed analgesics taken. The data were analyzed using the ${\chi}^2$, Friedman, Kruskal-Wallis, and Mann-Whitney U tests. Results: In all 3 groups, postoperative pain decreased significantly at each time interval (p < 0.05). At 24 hours, the OG group had less postoperative pain than the WGP group (p < 0.05). However, no significant difference was found between the RP group and the others. No statistically significant difference was found among the WGP, OG, and RP groups in postoperative pain intensity at 48 or 72 hours or in analgesic tablet intake at the 3 assessed time intervals. Conclusions: The OG group had less postoperative pain than the WGP group in the first 24 hours. The OG and RP systems were similar regarding postoperative pain intensity and analgesic intake.