• Title/Summary/Keyword: Glassy carbon electrode

Search Result 170, Processing Time 0.024 seconds

A Study on Enhancement of Np Extraction by TBP Through the Electrochemical Adjustment of Np Oxidation State by Using a Glassy Carbon Fiber Column Electrode

  • Kim, Kwang-Wook;Song, Kee-Chan;Lee, Eil-Hee;Park, In-Kyu;Yoo, Jae-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.309-315
    • /
    • 2000
  • The changes of Np oxidation state in nitric acid and the effect of nitrous acid on the oxidation state were analyzed by spectrophotometry, solvent extraction, and electrochemical methods. An enhancement of Np extraction to 30 vol.% TBP was carried out through adjustment of Np oxidation state by using a glassy carbon fiber column electrode system. The information of electrolytic behavior of nitric acid was important because the nitrous acid affecting the Np redox reaction was generated during the electrolytic adjustment of the Np oxidation state. The Np solution used in this work consisted of Np(V) and Np(Ⅵ)without (IV). The composition of Np(V) in the range of 0.5M -5.5 M nitric acid was 32% ~ 19%. The electrolytic oxidation of Np(V) to Np(Ⅵ)in the solution enhanced Np extraction efficiency about five times higher than the case without the electrolytic oxidation. It was confirmed that the nitrous acid of less than about 10-5 M acted as a catalyst to accelerate the chemical oxidation reaction of Np(V) to Np(Ⅵ).

  • PDF

Electrochemical Dechlorination of 1,2,4-Trichlorobenzene Using a Reticulated Vitreous Carbon Electrode

  • Paeng, Ki-Jung;Lim, Chae-Yun;Lee, Bo-Young;Myung, No-Seung;Rhee Paeng, In-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.9
    • /
    • pp.1329-1332
    • /
    • 2003
  • Stepwise dechlorination of 1,2,4-trichlorobenzene was observed at a glassy carbon electrode in dimethylformamide containing 0.1 M tetraethylammonium perchlorate. Especially, dechlorination to dichlorobenzene and further to monochlorobenzene or benzene was successfully demonstrated with a porous reticulated vitreous carbon electrode. Electrochemical dechlorination of polychlorobenzenes employing a flow cell with a reticulated vitreous carbon working electrode is also described. Preliminary experiments with a flow cell showed that dechlorination of trichlorobenzene to dichlorobenzene was partially completed while dechlorination to benzene or monochlorobenzene was not successful, suggesting that a flow rate and electrolysis time should be further optimized for the complete electrolysis.

Voltammetric Determination of Copper(II) Using Glassy Carbon Electrodes Modified with Nafion-DTPA-Glycerol

  • Park, Chan-Ju;Park, Eun-Heui;Chung, Keun-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.177-180
    • /
    • 2003
  • A glassy carbon electrode(GCE) modified with nafion-DTPA-glycerol was used for the highly selective and sensitive determination of a trace amount of Cu$\^$2+/. Various experimental parameters, which influenced the response of nafion-DTPA-glycerol modified electrode to Cu$\^$2+/, were optimized. The copper(II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry, A linear range was obtained in the concentration range 1.0${\times}$10$\^$-8/M∼1.0${\times}$10$\^$-6/M Cu(II) with 7 min preconcentration. Further, when an approximate amount of lead(II) is added to the test solution, nafion-DTPA-glycerol modified glassy carbon electrode has a dynamic range of 2 orders magnitude(1.0${\times}$10$\^$-9/M∼1.0${\times}$10$\^$-7/M). The detection limit(3 $\sigma$) was as low as 5.0${\times}$10$\^$-6/M(0.032ppb). The interferences from other metal ions could be reduced by adding KCN into the sample solutions. This method was applied to the determination of coppe,(II) in certified reference material(3.23${\times}$10$\^$-7/M, 21ppb), sea water(9.50${\times}$10/sup-7/M, 60ppb). The result agrees satisfactorily with the value measured by Korea Research Institute of Standard and Science.

  • PDF

A Study on in-situ Electrolytic Stripping of a Metal Ion by Using a Highly Packed Glassy Carbon Fiber Column Electrode System (고밀집 Glassy Carbon 섬유 다발체 전극 전해계를 이용한 금속 이온의 in-situ 전해 역추출 특성 연구)

  • Kim, Kwang-Wook;Kim, Young-Hwan;Lee, Eil-Hee;Yoo, Jae-Hyung
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.475-480
    • /
    • 1998
  • A study on the electrochemical reduction of uranium (VI) to uranium (IV) was carried out in the mixed phases of an organic phase with uranium (VI) and aqueous phase of nitric acid by use of a highly packed glassy carbon (GC) fiber column electrode system, and a model for in-situ electrolytic stripping of uranium (VI) was suggested. The electrochemical reduction of uranium (VI) occurred faster in organic phase than in aqueous phase of the mixed phases. The uranium stripping yield increased and then became constant with the increase of organic flow rate of the electrolytic system due to the increase of diffusion resistance of uranium ions in the organic phase into the aqueous phase. Aqueous flow rate, on the other hand, didn't affect the total uranium (VI) reduction current in the system. The system combined with electrochemical reduction was confirmed to be much more effective than the simple system without it in stripping uranium.

  • PDF

Differential Pulse Voltammetry of Lead(II) ton at Nation- EDTA-Glycerol Modified Glassy Carbon Electrodes (Nation-EDTA Glycerol이 수식된 유리탄소전극에서 납(II) 이온의 펄스차이전압전류법)

  • 박상희;박찬주;박은희;고영춘;정근호
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.53-58
    • /
    • 2002
  • A method for the determination of lead(II) ion using a nafion-EDTA(ethylene diamine tetraacetic acid)-glycerol modified glassy carbon electrode was proposed. Lead(II) ion is accumulated at the electrode by complexation and electrostatic attraction with nafion-EDTA-glycerol and detected at -0.560$\pm$0.015V (vs. Ag/AgCl) by differential pulse voltammetry. For the determination of lead(II) ion, a standard calibration curve if obtained from 10$^{-9}$ M lead(II) ion to 10$^{-7}$ M, and the detection limit(3s) is as low as 5.0$\times$10$^{-10}$ M.

Determination of Higenamine in the Commercial Aconiti Tuber and Its Pharmaceutical Preparations

  • Hahn, Young-Hee;Cheong, Kyo-Soon;Paik, Seung-Whan;YunChoi, Hye-Sook
    • Korean Journal of Pharmacognosy
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 1986
  • A cardiac principle of Aconiti tuber, higenamine was analyzed with a differential pluse voltammetry employing a glassy carbon electrode. The peak potentials for the oxidation of higenamine were varied depending on the pH of the media. Higenamine at the concentration of $5.4{\times}10^{-7}M$ (0.146ppm) was easily determined using a pH 7.0 phosphate buffer. The amounts of higenamine in the crude Aconiti tuber and tablets containing A. tuber were determined by a standard addition method after extracting with methanol, partitioning with a mixture of $H_2O$ and $CHCl_3$, and freeze-drying the aqueous layer.

  • PDF

Electrocatalytic Reduction of Dioxygen at Schiff base Co(II) Complexes supported Glassy Carbon Electrode in various pH Solution

  • Park, Kyoung-Hee;Rim, Chae-Pyeong;Chjo, Ki-Hyung;Jeon, Seungwon;Choi, Yong-Kook
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.617-622
    • /
    • 1995
  • Electrocatalytic reduction of dioxygen has been investigated by cyclic voltammetry at glassy carbon electrode modified with new Co(II)-Schiff base complexes in aqueous solutions of various pH. The reduction potentials of dioxygen at chemically adsorbed electrodes show the dependence of pH between pH 4 and 14. The catalytic effect is large and the reaction occurs via two or four electron transfer in various pH solution.

  • PDF

Effect of Transition Metal(II)-N,N-Bis(salicylaldehyde)phenylenediimines on the Electrochemical Reduction of Thionyl Chloride

  • 김현수;최용국;조기형;국성근;우희권
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.3
    • /
    • pp.223-227
    • /
    • 1996
  • Catalytic effects of transition metal (Co2+, Ni2+) complexes of N,N-bis(salicylaldehyde)-o-phenylenediimine (SOPD), N,N-bis(salicylaldehyde)-m-phenylenediimine (SMPD), and N,N-bis(salicylaldehyde)-p-phenylenediimine (SPPD), on the reduction of thionyl chloride at glassy carbon electrode, are evaluated by determining the kinetic parameters with cyclic voltammetric technique. The charge transfer process for the reduction of thionyl chloride is strongly affected by the concentration of the catalysts. Some quadridentate Schiff base-M(Ⅱ) complexes show sizable catalytic activities for the reduction of thionyl chloride. Catalytic effects of [M(Ⅱ)(SOPD)] complexes are slightly larger compared to [M(Ⅱ)2(SMPD)2] and [M(Ⅱ)2(SPPD)2] complexes. On those electrodes deposited with the catalysts, the observed exchange rate constants (ko) are in the range of 0.89-2.28 × 10-7 cm/s, while it is 1.24 × 10-7 cm/s on the bare glassy carbon electrode.

Kinetic Study of the Electrooxidation of Mefenamic Acid and Indomethacin Catalysed on Cobalt Hydroxide Modified Glassy Carbon Electrode

  • Saghatforoush, Lotfali.;Hasanzadeh, Mohammad.;Karim-Nezhad, Ghasem.;Ershad, Sohrab.;Shadjou, Nasrin.;Khalilzadeh, Balal.;Hajjizadeh, Maryam.
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.1341-1348
    • /
    • 2009
  • Electrocatalytic oxidation of two anti-inflammatory drugs (Mefenamic acid and Indomethacin) was investigated on a cobalt hydroxide modified glassy carbon (CHM-GC) electrode in alkaline solution. The process of oxidation and its kinetics were established by using cyclic voltammetry and chronoamperometry techniques as well as steady state polarization measurements. Voltammetric studies indicated that in the presence of under study drugs, the anodic peak current of low-valence cobalt species increased, followed by a decrease in the corresponding cathodic current. This result indicates that the drugs were oxidized via cobalt hydroxide species immobilized on the electrode surface via an E$\acute{C}$ mechanism. A mechanism based on the electrochemical generation of Co (IV) active sites and their subsequent consumption by the drugs in question was also investigated. The constants rate of the catalytic oxidation of the drugs and the electron-transfer coefficients reported.

Electrochemical Behaviour of (2,4-difluoro-phenyl)-(2-phenyl-1H-quinolin-4-ylidene)-amine in Aprotic Media (비양자성 매개물에서 (2, 4-difluoro-phenyl)-(2-phenyl-1H-quinolin-4-ylidene)-amine의 전기화학적 반응)

  • Kumari, Mamta;Sharma, D.K.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.50-56
    • /
    • 2011
  • The electrochemical reduction of (2,4-difluoro-phenyl)-(2-phenyl-1H-quinolin-4-ylidene)-amine was investigated in 0.1 M tetrabutylammoniumbromide in N,N-dimethylformamide at glassy carbon electrode (GCE) using the technique of cyclic voltammetry at the room temperature (290 K). The reduction of imines occurs in two successive steps, involving one electron in each. In this medium the first peak was observed at about -0.793 V (vs Ag/$Ag^+$) at the glassy carbon electrode surface, which is more stable and well defined as compared to the second peak. The diffusion coefficient ($D_0$) of imine in the investigated solvent media has been calculated using the modified Randles-Sevcik equation. The electron transfer coefficient ($\alpha$) of the reactant species has also been calculated.