• 제목/요약/키워드: Glass-net

검색결과 94건 처리시간 0.024초

2[MVA] 배전용 몰드변압기의 글라스넷 형상 최적설계 (Optimum Design of Glass Net in 2[MVA] Mold Transformer)

  • 전문호;김창업
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.107-112
    • /
    • 2011
  • In this paper, the optimum design of the glass net shape was studied to minimize the electric field of mold transformer. The glass net is used for reinforcement in structure between coils and epoxy, but it can cause to increase the electric field and the partial discharge. Therefore, the optimum design of glass net is required to minimize the electric field. In this paper, the objective function was approximated by using response surface method and then Zoom-in method was used for optimal design to minimize the electric field. The electric field was analysed using finite element method for each shape of glass nets.

Effect of the Oxide Glass on the Metal Sintering Behavior in Silver Thick-Film System

  • ;김호기
    • 한국세라믹학회:학술대회논문집
    • /
    • 한국세라믹학회 1986년도 Priceedings Of The Third Korea-Japan Seminar On New Ceramics
    • /
    • pp.259-267
    • /
    • 1986
  • The sintering behavior of silver-oxide glass composite thick-film has been studied with varing glass content. It is shown that during heat treatment glass became liquid phase to deeply affect the microstructure development of the silver particles and to control the physical properties of the thick-films. As glass content increased, the initial repacking of silver particles took place rapidly but the homogeneities of the microstructure showed different features. When the glass content was over some range, the silver particles exuded glass to decrease net energy and glass formed liquid pools separated from the solid skeletons. Finally the relations between the microstructures and electrical properties of the thick-film were discussed.

  • PDF

A formalism for the absorbed dose evaluation of the glass dosimeter

  • Ka-Young Park;Hyun-Chul Kim;Byoung-Chul Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2283-2287
    • /
    • 2023
  • We propose in the present work how the reference glass dosimeters can be introduced, which reflects the user irradiation condition. The reference glass dosimeters are used for correcting the reader fluctuation by reading it with sample glass dosimeters at the same time. Since they can be used without annealing after irradiation for long periods, one should consider both the fading effect and the natural background dose accumulation quantitatively. We construct an empirical but practical formalism of evaluating the absorbed dose on the glass dosimeter with the fading effect and the natural background dose accumulation considered.

제치장 콘크리트용 PC패널 개발에 관한 기초 실험 연구 (A Fundamental Study on the Development of Precast Exposed Concrete Pannel)

  • 표대수;황인성;홍상희;전충근;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.391-396
    • /
    • 2001
  • Exposed concrete execution is utilized insufficiently due to surface honecomb and undesirable appearance by entrapped air when existing placing method is applied. Therefore, surface glossing and impact properties of cement mortar incorporating fiber glass net blast furnace slag, expansive admixture and Polypropylene fiber are investigated in order to develop precast exposed concrete pannel by dry construction method. The kinds of the forms, placing method and admixture contents are varied. According to test results, surface glossing decrease with elapse of age. Considering the form kinds, surface glossing with acryle + astage shows the best performance. Placing horizontally shows positive results in reducing surface defects such as honecomb. Impacting resistance shows the best performance when glass fiber net applied, due to the enhance in toughness and absorption of impact.

  • PDF

Er과 Yb가 동시 첨가된 인산염계 유리를 이용한 이온 교환 도파로 광증폭기 (ion-Exchanged Waveguide Amplifier in Er/Yb-Doped Phosphate Glass)

  • 차상준;김원효;문종하
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 제13회 정기총회 및 2002년도 동계학술발표회
    • /
    • pp.172-173
    • /
    • 2002
  • An erbium-ytterbium co-doped phosphate glass waveguide amplifier, fabricated by two-step ion-exchange, is presented. The performance of the amplifiers are investigated in viewpoints of net gain, pump power, and noise figure. The waveguide has propagation loss of 0.7 dB/cm Including insertion loss at 1.304 $\mu\textrm{m}$. At a signal wavelength of 1.534 $\mu\textrm{m}$, a high net gain of 12.8 dB and low noise figure of less than 3.9 dB are archived in a 4 cm long waveguide when injected by 140 ㎽ of LD pump at 0.98$\mu\textrm{m}$ in single pass configuration.

  • PDF

Development of Powder Injection Molding Process for Fabrication of Glass Component

  • Lin, Dongguo;Lee, Junghyun;Park, Seong Jin
    • 한국분말재료학회지
    • /
    • 제23권1호
    • /
    • pp.26-32
    • /
    • 2016
  • Powder injection molding (PIM), which combines the advantages of powder metallurgy and plastic injection molding technologies, has become one of the most efficient methods for the net-shape production of both metal and ceramic components. In this work, plasma display panel glass bodies are prepared by the PIM process. After sintering, the hot isostatic pressing (HIP) process is adopted for improving the density and mechanical properties of the PIMed glass bodies. The mechanical and thermal behaviors of the prepared specimens are analyzed through bending tests and dilatometric analysis, respectively. After HIPing, the flexural strength of the prepared glass body reaches up to 92.17 MPa, which is 1.273 and 2.178 times that of the fused glass body and PIMed bodies, respectively. Moreover, a thermal expansion coefficient of $7.816{\times}10^{-6}/^{\circ}C$ is obtained, which coincides with that of the raw glass powder ($7.5-8.0{\times}10^{-6}/^{\circ}C$), indicating that the glass body is fully densified after the HIP process.

Biodentine과 복합레진, 글래스아이오노머의 물흡수도, 물용해도에 관한 비교 분석 (Comparison of water sorption / solubility of Biodentine, composite resin and glass ionomer cement)

  • 이의중;홍정민;민정범
    • 대한치과의사협회지
    • /
    • 제57권5호
    • /
    • pp.264-268
    • /
    • 2019
  • Objectives: This study aimed to measure the water sorption / solubility of Biodentine, composite resin and glass ionomer cement. Materials and Methods: The materials used in this study were Biodentine(BD), Filtek Z250(FZ) and Ketac Molar(KM). Twenty disc-shaped specimens of each material were prepared of 6mm diameter and 1mm thickness. All specimens were desiccated for 24 hours and weighed(m1). After then, They were immersed in distilled water and stored at $37^{\circ}C$. 1 week later, They were washed with running water, wiped with absorbent paper and weighed(m2). Finally, They were dried for 24 hours and weighed(m3). Water sorption and solubility, net water uptake were calculated. Results: KM and BD showed high water sorption than FZ(P<0.05). KM and BD exhibited similar water sorption(P<0.05). BD exhibited high solubility than KM(P=0.012). BD exhibited high net water uptake than FZ(P=0.008). Conclusion: Biodentine showed higher water sorption, solubility and net water uptake than Filtek Z250 and Ketac Molar. Within limitation of this study, it is not recommended to use Biodentine for permanent restoration.

  • PDF

흉부 CT 영상에서 결절의 밝기값, 재질 및 형상 증강 영상 기반의 GGN-Net을 이용한 간유리음영 결절 자동 분류 (Automated Classification of Ground-glass Nodules using GGN-Net based on Intensity, Texture, and Shape-Enhanced Images in Chest CT Images)

  • 변소현;정주립;홍헬렌;송용섭;김형진;박창민
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제24권5호
    • /
    • pp.31-39
    • /
    • 2018
  • 본 논문에서는 흉부 CT 영상에서 결절의 밝기값, 재질 및 형상 증강 영상 기반의 GGN-Net을 이용해 간유리음영 결절 자동 분류 방법을 제안한다. 첫째, 입력 영상에 결절 내부의 고형 성분의 유무 및 크기 정보가 포함될 수 있도록 밝기값, 재질 및 형상 증강 영상의 활용을 제안한다. 둘째, 다양한 입력 영상을 여러 개의 컨볼루션 모듈을 통해 획득한 특징맵을 내부 네트워크에서 통합하여 훈련하는 GGN-Net를 제안한다. 제안 방법의 분류정확성 평가를 위해 순수 간유리음영 결절 90개와 고형 성분의 크기가 5mm 미만인 혼합 간유리음영 결절 38개, 5mm 이상 고형 성분의 크기를 가지는 혼합 간유리음영 결절 23개의 데이터를 사용하였으며, 입력 영상이 간유리음영 결절 분류 결과에 미치는 영향을 비교하기 위해 다양한 입력 영상을 구성하여 결과를 비교하였다. 실험 결과, 밝기값, 재질 및 형상 정보가 함께 고려된 입력 영상을 사용한 제안 방법이 정확도가 82.75%로 가장 좋은 결과를 보였다.

Partitioning effects and corrosion characteristics of oxyapatite glass-ceramic wasteforms sequestering rare-earth elements

  • Kim, Miae;Kang, Jaehyuk;Yoon, Jang-Hee;Lee, Sang-Geul;Um, Wooyong;Kim, Hyun Gyu
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.997-1002
    • /
    • 2022
  • Oxyapatite[Ca2Nd8(SiO4)6O2] glass-ceramics have been suggested as wasteforms for the immobilisation of rare-earth radioactive nuclides because of their high waste-loading capability and good chemical durability. In particular, a partitioning effect is predicted to contribute to an enhancement of corrosion resistance in glass-ceramics compared with that of conjugate glasses of the same composition. Because rare-earths are inherently insoluble nuclides, detection of changes in corrosion behavior between glass-ceramics and conjugate glasses under normal conditions is not easy. In this study, therefore, we revealed the partitioning effect by exposing glass-ceramics and glasses to solution of pH 2, 7 and 10 at 90 ℃ for 20 d. In addition, we proposed the corrosion mechanism for oxyapatite glass-ceramics under various corrosion conditions. Especially, the glassy phase dissolved first, followed by the oxyapatite phase during pH 7 corrosion.

Artificial neural network approach for calculating mass attenuation coefficient of different glass systems

  • A. Benhadjira;M.I. Sayyed;O. Bentouila;K.E. Aiadi
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.100-105
    • /
    • 2024
  • In this study, we propose an alternative approach using Artificial Neural Networks (ANN) for determining Mass Attenuation Coefficients (MAC) in various glass systems. This method takes into account the weights of glass compositions, density, and photon energy as input features. The ANN model was trained and tested on a dataset consisting of 650 data points and subsequently validated through a K-fold cross-validation procedure. Our findings demonstrate a high level of accuracy, with R2 values ranging from 0.90 to 0.99. Additionally, the model exhibits robust extrapolation capabilities with an R2 score of 0.87 for predicting MAC values in a new glass system. Furthermore, this approach significantly reduces the need for costly and time-consuming computations and experiments, making it a potential tool for selecting materials for effective radiation protection.