• 제목/요약/키워드: Glass wool

검색결과 122건 처리시간 0.024초

알루미늄 소결재를 이용한 흡음 특성 연구 (Study of sound absorption characteristics using the sintered aluminium plate)

  • 노대호;김재수;윤진국;강현주;신종철;김원용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1071-1076
    • /
    • 2002
  • The purpose of this paper is to examine sound absorption characteristics of sintered Al(aluminum) plate. Comparison between experiment and theoretical analysts by using empirical formula are made. Based on comparison. it is found that Voronina model gives more reasonable explanation for sound absorption characteristics of sintered Al plates. Effect of air gap with varying the thickness of plates are also investigated, which concludes that the air gap generally increase absorption but for too thick thickness of Al plates. Al plates with air gap shows 0.85∼0.9 of NRC(Noise Reduction Coefficient) measured in reverberation room. which is comparable to glass wool. Comparison between normal and random Incident absorption shows that random incident absorption is higher than normal incident absorption.

  • PDF

ISO 13784-1과 ISO TS 17431(Model Box Test)에 적용을 통한 실대규모화재시편의 열방출율 분석 (Application to ISO 13784-1 and ISO TS 17431 as Real scale fire test methods for analyzing sandwich panel's Heat release rate)

  • 박계원;정재군;권오상;유용호;김흥열
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.196-200
    • /
    • 2011
  • ISO 13784-1 sandwich panel tests were conducted by FILK, KICT in Korea and SP in Sweden. Sandwich panels composed of steel sheets, EPS and glass wool supplied by FILK were tested. And in parallel, the same materials were tested using ISO TS17431 model box tests at GBRC and TUS in Japan.

  • PDF

실대규모 화재시험시 플래시오버와 연기발생율간의 상관성 연구 (Study on Correlation between flashover and smoke production rate in real scale reaction-to-fire test)

  • 박계원;임홍순;정재군;김운형
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.289-296
    • /
    • 2010
  • This study is aiming at analyzing correlation between flashover's time and maximum smoke production rate's time on sandwich panel specimens. For this analysis, KS F ISO 137481-1 has been performed for 23 kinds of sandwich panels which mainly consist of EPS, PIR, PUR, Glass wool and so on. KS F ISO 13784-1 represents real scale reaction-to-fire test and focuses on measuring flashover phenomenon rather than other tests as like ISO 5660-1 and SBI.

  • PDF

다양한 산업부산물들의 포졸란 반응성 비교분석 (Comparative Analysis of Various Industrial By-Products Pozzolanic Activity)

  • 최익제;김지현;정철우;이수용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.32-33
    • /
    • 2016
  • In this work, pozzolanic activities of various waste materials were compared with those of well-known pozzolanic materials. Uncondensed and densified silica fume, two ASTM class F fly ashes with different calcium contents, and bentonite powder, ceramic powder obtained from wash basin, and waste glass wool, which can possibly possess pozzolanic property were chosen for comparison. Drop in electrical conductivity at 40℃ saturated lime solution was measured for each materials. The amount of Ca(OH)2 decomposed from cement paste at 450~500℃ was also measured used to evaluate pozzolanic activity. The 28 day compressive strength were used to observe the mechanical property enhanced by various waste materials.

  • PDF

틸팅 열차용 허니콤 복합판재의 투과손실 (Transmission loss of Honeycomb Composite Panel of the Tilting Train)

  • 김석현;임봉기;김재철;장윤태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1088-1091
    • /
    • 2009
  • In a tilting train, aluminium honeycomb composite panel is used for the high speed and light weight. Side wall of the tilting train includes the composite panel of carbon fiber, aluminium honeycomb and epoxy fiber as a main structure. In this study, we measure the transmission loss (TL) of the honeycomb composite panel and analyse the sound insulation performance by using the orthotropic plate model. We investigate experimentally how the air gap, plywood and glass wool improve the sound insulation performance of the composite panel. The purpose of the study is to provide practical information for the improvement of TL of the honeycomb composite panel used for the tilting train.

  • PDF

주름강판의 차음성능 향상 방안 (Improvement Strategy of the Sound Insulation Performance of a Corrugated Steel Panel)

  • 이현우;김석현;김정태;김재철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1097-1102
    • /
    • 2009
  • In a railway vehicle, corrugated steel panel is widely used for the floor panel because of its high bending stiffness and light weight. However, this panel shows lower sound insulation performance than that of the plate with the same weight. Especially, in a particular frequency band, transmission loss (TL) rapidly decreases and it results in the deterioration of TL of the overall floor panel. This study identifies that the remarkable drop in TL is caused from the local resonance of the periodic corrugated structure. This study shows that the frequency band of the TL drop can be controlled by the proper design of the corrugated structure. In addition, improvement effect of TL by attaching foam and glass wool is estimated by experiment. The purpose of the study is to provide the practical information for the improvement of the sound insulation performance of the corrugated steel.

  • PDF

하향식 바이오매스 가스화장치의 개발 및 평가 (Development and Assessment of a Downdraft Gasifier for Biomass Gasification)

  • 홍성구;심재훈
    • 한국농공학회논문집
    • /
    • 제50권4호
    • /
    • pp.89-97
    • /
    • 2008
  • A downdraft gasifier was manufactured for biomass gasification. The gasifier was designed based on the principles of gasification presented in previous studies. The pipes of 25mm diameter were used for both supplying air and discharging producer gas. Wood charcoals were mostly used for fuels. The concentration of CO ranged from 25 to 35%, comparable to the values presented in other studies. The temperature outside wall of the gasifier was measured up to $400^{\circ}C$, indicating a great heat loss. When glass wool was cover over the wall, some parts of wire mesh located in the bottom of the reactor were molten down. There were several modifications that should be made in order to improve its efficiency and obtain more stable continuous gasification, including insulation, reduction in pressure loss, durable bottom meshes, the optimum length of reaction part, and safety.

혼합재 및 입도에 따른 경량기포콘크리트의 강도특성 개선 (Improvement of Strength in ALC using Admixtures and Grain Size)

  • 김영엽;송훈;이종규;추용식
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.79-82
    • /
    • 2007
  • Recently, the use of ALC has became increasingly popular. ALC is a unique building material. Because of its cellular nature, it is lightweight, self-insulating, sound and fireproof, as well as insect and mold resistant. Furthermore, ALC is free of VOCs and various fibers associated with wood and glass wool construction. However, ALC have high water absorption, low compressive strength and popout the origin of the low surface strength in its properties. These properties make troubles under construction such as cracking and popout. Thus, this study is to improve the fundamental strength by controls of increasing of admixtures, and grain size. Admixtures make use of metakaolin, silica fume, sodium silicate and sodium hydroxide. From the test result, the ALC using admixture have a good fundamental properties compared with plain specimen. Compressive strength, specific strength and abrasion's ratio were improved depending on increasing admixtures ratio's, and grain size.

  • PDF

Cone-Calorimeter와 연기밀도챔버를 이용한 고무발포단열재의 연기밀도 비교 (Smoke Density Comparison of Rubber Foam Insulator by the test between Cone-Calorimeter and Smoke Density-Chamber)

  • 조희기;이덕희;이철규;이동우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.941-946
    • /
    • 2005
  • Kinds of Sound & Thermal Insulator are being used for materials of railroad vehicles as a barrier of beat and noise. Glass Wool, PE foam, PP foam are such kinds of materials. In case of fire, it shows various combustion properties. In this study, we compared the Smoke Density of the Rubber Foam Insulator by test between Cone-Calorimeter and Smoke Density-Chamber. The results showed that the Rubber Foam Insulator had an important role in the insulator thickness and the test method, We forecast the smoke density by test between Cone-Calorimeter and Smoke Density-Chamber.

  • PDF

틸팅열차 측면재의 차음 전략 (Sound Insulation Strategy of the Side Panels in a Tilting Train)

  • 김석현;서태건
    • 산업기술연구
    • /
    • 제31권A호
    • /
    • pp.33-38
    • /
    • 2011
  • In an express tilting train, side wall insulating the noise from the exterior sound source consists of two parts. One is the layered composite panel including aluminum honeycomb, glass wool and nomex honeycomb. The other is the double glazed window. In this study, sound insulation performance of the two parts is investigated by mass law and experiment. Based on ASTM E2249-02, the intensity sound transmission loss (TL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance in respect of weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy for the interior noise reduction is investigated.

  • PDF