• Title/Summary/Keyword: Glass material

Search Result 2,845, Processing Time 0.027 seconds

An Experimental Study on the Degradations of Material Properties of Vinylester/FRP Reinforcing Bars under Accelerated Alkaline Condition (급속 알칼리 환경하에서의 비닐에스터/FRP 보강근의 재료성능 저하 특성에 관한 실험적 연구)

  • Oh, Hongseob;Kim, Younghwan;Jang, Naksup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.51-59
    • /
    • 2019
  • There is increasingly more research focusing on the application of FRP reinforcing bars as an alternative material for steel reinforcing bars, but most such research look at short term behavior of FRP reinforced structures. In this study, the microscopic analysis and tensile behavior of Basalt and Glass FRP bars under freezing-thawing and alkaline conditions were experimentally evaluated. After 100 cycles of the freezing and thawing, the tensile strength and elastic modulus of FRP bars decreased by about 5%. In the case of microstructure of FRP bars during the initial 20 days, no significant damages of FRP bar sections were found under $20^{\circ}C$ alkaline solution; however, the specimens immersed in $60^{\circ}C$ alkaline solution were found to experience resin dissolution, fiber damage and the separation of the resin-fiber interface. In the alkaline environment, the strength decrease of about 10% occurred in the environment at $20^{\circ}C$ for 100 days, but the tensile strength of FRPs exposed for 500 days decreased by 50%. At temperature of $40^{\circ}C$ and $60^{\circ}C$, an abrupt decrease in the strength was observed at 50 and 100 days. Especially, the tensile strength decrease of Basalt fiber Reinforced Polymer bars showed more severe degradation due to the damage caused by dissolution of resin matrix and fiber swelling in alkaline solution. Therefore, in order to improve the long-term performance of the surface braided FRPr reinforcing bars, surface treatment is required to ensure alkali resistance.

ITZ Analysis of Cement Matrix According to the Type of Lightweight Aggregate Using EIS (EIS를 활용한 경량골재 종류별 시멘트 경화체의 계면특성 분석)

  • Kim, Ho-Jin;Jung, Yoong-Hoon;Bae, Je-Hyun;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.498-505
    • /
    • 2020
  • Aggregate occupies about 70-85% of the concrete volume and is an important factor in reducing the drying shrinkage of concrete. However, when constructing high-rise buildings, it acts as a problem due to the high load of natural aggregates. If the load becomes large during the construction of a high-rise building, creep may occur and the ground may be eroded. Material costs increase and there are financial problems. In order to reduce the load on concrete, we are working to reduce the weight of aggregates. However, artificial lightweight aggregates affect the interface between the aggregate and the paste due to its higher absorption rate and lower adhesion strength than natural aggregates, affecting the overall strength of concrete. Therefore, in this study, in order to grasp the interface between natural aggregate and lightweight aggregate by type, we adopted a method of measuring electrical resistance using an EIS measuring device, which is a non-destructive test, and lightweight bone. The change in the state of the interface was tested on the outside of the material through a blast furnace slag coating. As a result of the experiment, it was confirmed that the electric resistance was about 90% lower than that in the air-dried state through the electrolyte immersion, and the electric resistance differs depending on the type of aggregate and the presence or absence of coating. As a result of the experiment, the difference in compressive strength depending on the type of aggregate and the presence or absence of coating was shown, and the difference in impedance value and phase angle for each type of lightweight aggregate was shown.

Structural Performance Evaluation of Reinforced Concrete Column Reinforced with Aramid Fibers and PET Fibers (아리미드섬유와 PET섬유시트로 보강한 철근콘크리트 기둥의 구조성능평가)

  • Dong-Hwan Kim;Min-Su Jo;Jin-Hyeung Choi;Woo-Rae Cho;Kil-Hee Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.78-85
    • /
    • 2023
  • This study evaluates the performance of reinforced concrete columns using hybrid fiber sheets for structural behavior. The purpose of this method is to improve the load-bearing capacity of the reinforced structure by impregnating a hybrid fiber sheet, which is woven by arranging aramid and glass fibers uniaxially and attached to an aged concrete structure requiring reinforcement with epoxy. In particular, not only the weight reduction of the material obtained by using a fiber lighter than the steel material, but also the low-strength, high-toughness fiber element among the fibers used delays the brittle fracture of the high-strength, low-toughness fiber element. The low-strength, high-toughness fiber element among the fibers used delays the brittle fracture of the high-strength, low-toughness fiber element, resulting in weight reduction compared to steel. The study conducted structural tests on four specimens, with the hybrid reinforcement method and failure mode as main variables. Specimen size and loading conditions were chosen to be comparable with previous studies. The structural performance of the specimen was evaluated using energy dissipation capacity and ductility. Analysis shows that excellent results can be obtained with the hybrid fiber sheet reinforcement.

Preparation and Properties of Crosslinked Thermo-responsive Poly(N-isopropylacrylamide) Gel Materials For Smart Windows - Effect of Glycerol Content in Water/Glycerol Solvent - (스마트 윈도우용 가교 열감응성 폴리(N-이소프로필아마이드) 겔 소재의 제조 및 특성 - 물/글리세롤 혼합용매 중의 글리세롤 함량의 영향 -)

  • Park, Jae-Hyong;Kim, Il-Jin;Lee, Dong-Jin;Sim, Jae-Hak;Song, Min-Seop;Lee, Young-Hee;Yoo, Jung-Whan;Kim, Han-Do
    • Clean Technology
    • /
    • v.24 no.2
    • /
    • pp.112-118
    • /
    • 2018
  • Thermo-responsive polymers that exhibit phase transition in response to temperature change can be used as materials for smart windows because they can control solar light transmission depending on the outside temperature. The development of thermo-responsive polymers for smart windows that can be used over a wide temperature range is desirable. To obtain high performance smart windows materials, three-dimensional thermo-responsive poly(N-isopropylacrylamide) (PNIPAm) gels were prepared by free radical polymerization from monomer N-isopropylacrylamide, N, N'-methylenebis acrylamide (MBAm) as a crosslinking agent, ammonium persulfate (APS) as a strong oxidizing agent/tetramethylene diamine as a catalyst, and a mixture of two solvents (water/glycerol). This study examined the effect of glycerol content on the lower critical solution temperature (LCST), freezing temperature and the solar light transmittance of crosslinked PNIPAm gel films. The LCST and freezing temperature of PNIPAm gel films were found to be significantly decreased from 34.3 and $6.3^{\circ}C$ to 28.2 and $-6.5^{\circ}C$ with increasing glycerol content from 0 wt% to 10 wt%, respectively. It was found that the transparent PNIPAm gel films at $25^{\circ}C$ (temperature < LCST) were converted to translucent gels at higher temperature ($45^{\circ}C$) (temperature > LCST). These results suggested that the crosslinked PNIPAm gel materials prepared in this study could have high potential for application in smart glass materials.

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

Lung Biopsy after Localization of Pulmonary Nodules with Hook Wire (Hook Wire를 이용한 폐결절의 위치선정 및 생검)

  • Kim, Jin-Sik;Hwang, Jae-Joon;Lee, Song-Am;Lee, Woo-Surng;Kim, Yo-Han;Kim, Jun-Seok;Chee, Hyun-Keun;Yi, Jeong-Geun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.681-686
    • /
    • 2010
  • Background: A chest computed-tomography has become more prevalent so that it is more common to detect small sized pulmonary nodules that have not been found in previous simple chest x-ray. If those detected nodules are undersized or located in pulmonary parenchyma, it is difficult to accomplish a biopsy since it is vulnerable to explore them either grossly or digitally. Thus, in our hospital, a thoracoscopic pulmonary wedge resection was performed after locating a lesion by means of hook wire with CT-guided. Material and Method: 31 patients (17 males and 14 female patients) from December in 2006 to June in 2010 became our subjects; their 34 pulmonary nodules were subjected to the thoracoscopic pulmonary wedge resection after locating a lesion by means of hook wire with CT-guided. Also we analyzed a possibility of hook wire dislocation, a frequency of conversion to open thoracotomy, time consumed to operation after location of a lesion, operation time, post operation complication, and histological diagnosis of the lesion. Result: 12 of 34 cases were ground glass lesion, whereas 22 cases of them were solitary pulmonary lesion. The median value of the lesion was 8mm in size (range: 3 to 23 mm), while the median value was 12.5 mm in depth (range: 1 to 34 mm). The median value of time consumed from location of the lesion to anesthetic induction was 86.5 minutes (41~473 minutes); furthermore the mean value of operation time was 103 minutes (25~345 minutes). Intrathoracic wire dislocation was found in one case, but a target lesion was successfully excised. Open thoracotomy was performed in four cases due to pleural adhesion. However, there was no case of conversion to open thoracotomy due to failure to detect a target lesion. In histological diagnosis, metastatic cancer were found in 15 cases, which were the most common, primary lung cancer were in 9 cases, non-specific inflammation were in 3 cases, tuberculosis inflammation were in 2 cases, lymph nodes were in 2 cases, active tuberculosis were in 1 case, atypical adenomatous hyperplasia was in 1 case and normal lung parenchymal finding was in 1 case, respectively. Conclusion: In our hospital, in order to accomplish a precise histological diagnosis of ground-glass lesion and pulmonary nodules in lung parenchyma, location of pulmonary nodules were exactly located with hook wire under chest computed-tomography, which was followed by lung biopsy. We concluded that this was an accurate, minimally invasive and valuable method to minimize the complications and increase of cost of medical service provided.

THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS (구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구)

  • Park, Yeon-Hong;Min, Byung-Soon;Choi, Ho-Young;Park, Sung-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF

Development of Optimum Grip System in Developing Design Tensile Strength of GFRP Rebars (GFRP 보강근의 설계 인장강도 발현을 위한 적정 그립시스템 개발)

  • You Young-Chan;Park Ji-Sun;You Young-Jun;Park Young-Hwan;Kim Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.947-953
    • /
    • 2005
  • Previous test results showed that the current ASTM(American Standard for Testing and Materials) grip adapter for GFRP(Glass Fiber Reinforced Polymer) rebar was not fully successful in developing the design tensile strength of GFRP rebars with reasonable accuracy. It is because the current ASTM grip adapter which is composed of a pair of rectangular metal blocks of which inner faces are grooved along the longitudinal direction does not take into account the various geometric characteristics of GFRP rebar such as surface treatment, shape of bar cross section as well as physical characteristics such as poisson effect, elastic modulus in the transverse direction and so on. The objective of this paper is to provide how to proportion the optimum diameter of inner groove in ASTM grip adapter to develop design tensile strength of GFRP rebar. The proportioning of inner groove in ASTM grip adapter is based on the force equilibrium of GFRP rebar between tensile capacity and minimum frictional resistance required along the grip adapter. The frictional resistance of grip adapter is calculated based on the compressive strain compatibility in radial direction induced by the difference between diameter of GFRP rebar and inner groove In ASTM grip. All testing procedures were made according to the CSA S806-02 recommendations. From the preliminary test results on round-type GFRP rebars, it was found that maximum tensile loads acquired under the same testing conditions is highly affected by the diameter of inner groove in ASTM grip adapter. The grip adapter with specific dimension proportioned by proposed method recorded the highest tensile strength among them.

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

A Study of School Waste Disposal Status and Its Reforms (Public Primary and Secondary Schools in Seoul) (학교 쓰레기 처리현황과 개선에 관한 연구 - 서울시 공립 초.중등학교를 대상으로 -)

  • 노성빈
    • Hwankyungkyoyuk
    • /
    • v.3 no.1
    • /
    • pp.130-140
    • /
    • 1992
  • The purpose of this study was to survey the trends of waste products in schools, its gathering and disposal, identification of problems and to analyze its disposal. Moreover, this study was aimed at basic suggestions about the establishment and plans of waste environmental education. 98 public primary and secondary schools were surveyed in Seoul during the month of March and April, 1991. Information was collected from each educational association by random sampling. Questionaries were used for this survey. To understand the disposal status of school waste and its reforms, this study surveyed the amount of waste by products, their origin and analyzed the disposal by type, one number of schools and teachers involved. The dump sited and disposal methods of school waste, its problems, and the status of school waste educations were researched, and ideal disposal methods and plans for waste education were suggested. The results were as follows. 1. The School's trash was produced by followings: paper, vinyle plastics, food, woods, metals, ceramics, glass, bottles, and ash from the heating system. The biggest cause of the school's waste as shown by the survey was a lack of environmental awareness(39.8%). The second biggest was the use of a one time use of disposable paper products(27.6%). 2. Waste collection by different grade levels were proven to be important but as you move from elementary to high school, the waste collecting operation decreased, in this connection between the students and waste collection itself it was significant on the other hand the teachers were not working as significant variables. 3. Of the school that collected waste 69.5 percent of the schools separately grouped common waste and recyclable waste. 25 schools(42.4%) received improvement on their environmental awareness of trash collection through this method. 4. From the number of disposal sites in surveyed schools, it was determined that the education of the necessity for separation of waste was performed in vain and accordingly the should require a real education in the future. 5. Regarding the method of disposal of waste the survey indicated that the #1 method of disposal was partial burning and the remains carried to a dump site by others(35,7%). In elementary schools the entire waste was taken by individuals to a dump site (33.3%). In high schools partial burning and then transported by individuals #1 in our survey(50%). 6. Relative to the problem of the treatment to waste, the emission of smoke from the burning was considered to be the #1 priority in our survey (62.3%) the problem of trash collection being delayed was 52.1%(1in our survey). 7. The present situation of environmental education of waste us lacking. Under present circumstances, the practice of public announcements for improvement and waste-paper collection has been going on vigorously but lacking in education as to the preparation of compositions for students the themes of public exhibitions, the organizing of voluntary associations should be part of the education system to reinforce student's awareness of proper waste disposal. 8. The most economical alternative for disposal was recycling usable waste or combustible material through a variety of education we can therefore educate students bring this education to their homes public servants will also be able to benefit in the waste disposal process with proper education. In conclusion we should intensify the systemical organization and the education of our waste disposal for a better environment.

  • PDF