The Study on Characteristics of Collected Filter as Analysis of Carbon in Airborne Particulate Matters by Elemental Analyzer (원소분석기를 사용한 부유입자상물질중의 탄소성분 분석시 포집여지의 특성에 관한 연구)

  • 황경철;조기철;최종욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.67-73
    • /
    • 1995
  • In order to study of characteristics of collected filter as analysis of carbon in airborne particulate matters by Elemental Analyzer, quartz fiber filter and glass fiber filter were used. The results are followed as; There was no difference of confidence in collection rate of airborne particulate matters between quartz fiber filter and glass fiber filter. Airborne particulate matters were collected on both filters evenly and the use of quartz fiber filter is better than glass fiber filter as analysis of carbon by thermal method.

  • PDF

A study on the Polymer surface treatment of GF-filter bag for collection of fine Particle like carbon black (카본블랙류 미세입자 포집을 위한 유리섬유 필터백의 고분자 표면처리에 관한 연구)

  • Lee, B.;Choi, H.L.;Moon, C.K.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.55-59
    • /
    • 2008
  • In this paper, we have investigated on collection efficiency of fine particle of glass fiber-filter bag according to the surface treatment. The solution consisted of polytetrafluoroethylene(teflon), graphite powder, silicon resin and water was used as a basic surface treatment agent. Tensile strength of glass filter-bag increased with up to 3hrs and then decreased with surface treatment time. Tensile strength and initial modulus of the glass fiber-filter bag treated by iodine after basic surface treatment for 3hrs were lower than those of basic surface treatment for 3hrs, however collection efficiency and fracture strain were higher than those of basic surface treatment for 3hrs. Glass fiber-filter bag with lower initial modulus and more strain will be extend the durable period and the one treated by iodine after basic surface treatment 3or 3hrs is expected high collection efficiency of fine particle. This method makes it possible to manufacture glass fiber-filter bag of the optimum condition.

  • PDF

Comparison of Glass Particle Contamination according to Method of Ampule Cutting and Needle Aspiration (유리앰풀 개봉 관련 요인에 따른 주사용액 내 유리조각 혼입 정도 비교)

  • Park, Jeong-Sook;Oh, Hyae-Ryeung;Seo, Bo-Hyae;Bhang, Jung-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.6
    • /
    • pp.1033-1041
    • /
    • 2006
  • Purpose: Glass particle contamination of the contents of single-dose glass ampules can occur upon opening. Different aspiration techniques, different sizes of needles, different sizes of ampules, and different cutting methods were studied to determine if they had any effect on glass particle contamination. Method: Different aspiration techniques(with filter, without filter), different sizes of needles(18G, 25G), different sizes of ampules(2ml, 20m1), and different cutting methods(with cotton, without cotton) were evaluated. Method: Twenty ampules were randomly assigned in each group. Three slides containing glass particles for each ampule were made and counted under a microscope by 3 study blind persons. Result: The number of glass particle contamination is much less when using a filter rather than without a filter. The number of glass particle contamination is much less when using a 25G needle rather than on 18G needle. The number of glass particle contamination is much less when using 2ml ampules rather than 20m1 ampules. The number of glass particle contamination is much less when using cotton rather than without cotton. Conclusion: It was shown that using a filter, a small size needle, smaller sized ampules and using cotton when cutting the ampule will decrease the risk of parenteral injection of glass particles.

A Study on Polynuclear Aromatic Hydrocarbons Emitted by Coking Time and Sampling Method in a Coke Oven Plant (코크스제조공정에서 탄화시간과 시료채취방법에 따른 다핵방향족탄화수소 발생에 관한 연구)

  • Yun, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.37-53
    • /
    • 1993
  • The polynuclear hydrocarbons (PAHs) emitted from coke oven standpipe were sampled using three sampling systems, including glass fiber filter+silver membrane filter, glass fiber filter+silver membrane filter+XAD-2 adsorbent tube, PTFE membrane filter+XAD-2 adsorbent tube, extracted by methylene chloride and analysed by gas chromathography using flame ionization detector. The results of this study were as follows. 1. Because the amounts of coke oven emissions(COE) were large, the analyses of PAHs were simple and possible without evaporation and concentration. Although the generation of COE was high during early stage of coking, the airborne concentration of PAHs was low and increased during late coking. 2. The contents of PAHs in COE were 1.35-2.81%. 3. The index components of PAHs were fluoranthene and pyrene. Their correlation coefficient to total PAHs were 0.96, 0.95, respectively. 4. The particulate PAHs were sampled by filter and gaseous PAHs by adsorbent tube. The collection efficiency of glass fiber filter+silver membrane filter was 20% of total amount sampled by filters+adsorbent and PTFE membrane filter 50%. Adsorbent tube must be attached to the filter to collect light and small PAH components. 5. The generation of acenaphthene and indeno (1,2,3-cd) pyrene were low and concentrations of fluorene and anthracene were $20-40ug/m^3$ throughout coking time. Other PAH eoncentrations were sometimes high. The generation of PAHs was low at 4-6 hours of coking time. The gaseous PAHs were generated earlier than particulate PAHs.

  • PDF

The Factors Influencing Glass Particles in Single Dose Glass Ampules upon Opening (유리앰플 개봉 시 미세 유리조각 유입에 영향을 미치는 요인)

  • Song, Ju-Yeon;Kim, Dong-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.14 no.2
    • /
    • pp.166-172
    • /
    • 2007
  • Purpose: The purpose of this study was to examine the factors influencing glass particle contamination in single dose glass ampules upon opening. Method: The study was single case experimental design. Different methods of opening ampule (hand, wooden stick), different sizes of ampules(1cc, 2cc) and different sizes of needles(17gauge, 23gauge, $5{\mu}m$ filter) were evaluated. Eighteen ampules were randomly assigned in each group. The number of glass ampule particles ${\ge}10{\mu}m$ was counted by microscope. Results: There was no significant difference in the number of particles aspirated by opening methods. But number of glass particles was much lower when using 1cc ampules rather than 2cc ampules and was also much lower when using smaller size needles and needles which include a $5{\mu}m$ filter rather than larger size of needles. Conclusion: We suggest that larger bore or unfiltered needles increase the risk of aspirating more glass particles than smaller bore or filter needles. In addition, these data show that a wooden stick can be used as a method opening glass ampules.

  • PDF

The Study on Pre-treatment Method of Filter for Analysing the Heavy Metals in Air Quality (대기중의 중금속 분석을 위한 여지의 전처리 방법에 관한 연구)

  • 김광래;이상칠;어수미;김민영;신재영;이재영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.16-19
    • /
    • 2002
  • This study was carried out to establish the standardized analysis method in order to decide accurate concentrations of hazardous metals in the air. Acid decomposition method used usually was compared to microwave digestion method. Comparing results of tested background concentration in blank filter, we found that the magnitude of element concentration was Na, Ca, K, Mg, Al and Ba by order. The element concentrations of Glass fiber filter were higher than those of Quartz fiber filter, and the number of undetected components in Glass fiber filter was lower than that in Quartz fiber filter. Thus it is supposed that the concentration of background elements in Glass fiber filter was higher than those in Quartz fiber filter The extraction rate of microwave digestion method was superior to those of acid decomposition method during the test of blank filter as well as SRM of NIST. In case of the SRM of NIST, the average extraction efficiency of acid decomposition Method and microwave pretreatment is 53.8∼82.7%, 81.3∼97.1%, respectively. This result might be caused by the closed system of Microwave, which make outflow and loss of components less. Also microwave digestion method has other merits such as the minimization of time, reagents, and contamination. Furthermore, if the extraction condition, extraction time and used acids are optimized, the better results will be represented.

  • PDF

Purification of Water Contaminants Using Activated Carbon Fiber Filter with Phenolic Resin Coated on Glass Fibers as a Precursor

  • Baek, Il-Hyun
    • Carbon letters
    • /
    • v.1 no.2
    • /
    • pp.82-86
    • /
    • 2000
  • The present research was undertaken to evaluate the possibility of water purification filter with activated carbon fibers (ACFs) using a very low cost precursor consisting of phenolic resin coated on glass fibers. The simplified procedure involving coating, curing and activation and a very low cost glass fiber as a raw material were adopted in order to reduce manufacturing cost. The breakthrough curves of the manufactured ACFs and the commercial activated carbon (AC, Calgon F-200) were investigated in the initial concentration range from 19 to 49 ppm for benzene, toluene and ethylbenzene. From breakthrough profiles, the manufactured ACFs had significantly faster adsorption kinetics than the AC. Especially the benzene breakthrough curves, the manufactured ACF (13 g of ACF with 32% of carbon on the glass) was over the limited level (5 ppb) after flowing of 32 l at initial concentration of 15 ppm, while the commercial AC was shown about 3 ppm in initial adsorption.

  • PDF

Compact Spatial Triple-Band-Stop Filter for Cellular/PCS/IMT-2000 Systems

  • Kim, Dong-Ho;Yeo, Jun-Ho;Choi, Jae-Ick
    • ETRI Journal
    • /
    • v.30 no.5
    • /
    • pp.735-737
    • /
    • 2008
  • We propose a novel spatial multi-band-stop filter using modified multiple loop array elements to block electromagnetic waves or signals of mobile phones in public facilities. It operates at the following frequency bands: Korean cellular (824 MHz to 894 MHz), Personal Communication Service (PCS) (1.75 GHz to 1.87 GHz), and IMT-2000 (1.92 GHz to 2.17 GHz). Two frequency selective surfaces with modified multiple-loop elements are printed on the top and bottom of a pair-glass pane, which is a pair of glass panes with an air gap between them. A modified multiple-loop element with a meander line is used to make the size of the filter compact. The simulated and measured results show good agreement, which confirms the usefulness of the proposed tri-band spatial filter.

  • PDF