• Title/Summary/Keyword: Glass Fibre

Search Result 64, Processing Time 0.022 seconds

Experimental study on strengthening of R.C beam using glass fibre reinforced composite

  • Mini, K.M.;Alapatt, Rini John;David, Anjana Elizabeth;Radhakrishnan, Aswathy;Cyriac, Minu Maria;Ramakrishnan, R.
    • Structural Engineering and Mechanics
    • /
    • v.50 no.3
    • /
    • pp.275-286
    • /
    • 2014
  • This paper reports the influence of number of layers and length of GFRP sheets wrapped onto RCC beams for strengthening. Twelve beams of size $700mm{\times}150mm{\times}150mm$ were cast and tested. Two beams without GFRP and ten beams wrapped in different lay-up patterns with one and two layers of GFRP sheets was subjected to three point loading test and ultrasonic pulse velocity test. Initial crack load, ultimate failure load and types of failure have been observed and noted. Experimental results indicate a significant increase in initial and ultimate load carrying capacity of GFRP wrapped beams compared to unwrapped beams. The failed control specimen was retrofitted using U wrap scheme and tested under three point loading.

An Investigation on the Crystal Growth Studies and Emission line shape in $Er^{3+}$-doped Sodium Tellurite Glasses

  • Joshi, Purushottam;Jha, Animesh
    • Ceramist
    • /
    • v.10 no.3
    • /
    • pp.67-74
    • /
    • 2007
  • Crystallisation kinetics of the erbium doped soda-tellurite glasses were studied using the differential thermal analysis (DTA) and differential scanning calorimetery (DSC) techniques. The DTA curves in the temperature range of 350 K to 650 K were obtained from isochronal heating rates, chosen in the range of 2 to 20 K/min. DSC isothermal curves were used to calculate the fraction of crystals formed on reheating. The apparent activation energies for devitrification were derived by measuring the shifts in the values of $T_g$ and $T_x$ with heating rates, using the Kissinger method. The derived values of apparent activation energies for isochronal and isothermal methods varied in the range of $190-204\;{\pm}\;5\;kJ\;mol^{-1}$. The X-ray powder diffraction analysis of heat treated and transparent samples showed the presence of nano-scale size sodium-tellurite crystals. These crystallites were found to have a strong influence on the full width of half maxima of the transition in $Er^{3+}:\;^4I_{13/2}{\rightarrow}^4I_{15/2}$, which extended from 70 nm in the vitreous materials to 132 nm in glass-ceramic materials.

  • PDF

Surface static properties in polymer hybrid material after plasma treatment (플라즈마 처리한 고분자 복합재료의 표면특성변화)

  • Park, Jong-Kwan
    • 전자공학회논문지 IE
    • /
    • v.44 no.3
    • /
    • pp.6-11
    • /
    • 2007
  • In this study, which was performed to identify a degradation mechanism in macromolecular insulating material, the contact angle, surface potential decay, surface resistance rate and XPS analysis were compared after exposure of fibre-glass-reinforced polymer laminate to plasma discharge. In the case of chemical changes arising from plasma treatment, carboxyl radicals were generated mainly in the plasma-treated surface, which was rapidly changed to a hydrophilic surface. In the corona potential decay study to determine the electrical changes, leading to a negative surface for the untreated specimen. However, in the case of the hydrophilic surface, a lot of carboxy radicals(-COO) acting as positive polarity were generated, resulting in a positive surface. Owing to such a positive surface, the charges of applied negative polarity were decreased rapidly.

Bond properties of steel and sand-coated GFRP bars in Alkali activated cement concrete

  • Tekle, Biruk Hailu;Cui, Yifei;Khennane, Amar
    • Structural Engineering and Mechanics
    • /
    • v.75 no.1
    • /
    • pp.123-131
    • /
    • 2020
  • The bond performance of glass fibre reinforced polymer (GFRP) bars and that of steel bars embedded in Alkali Activated Cement (AAC) concrete are analysed and compared using pull-out specimens. The bond failure modes, the average bond strength and the free end bond stress-slip curves are used for comparison. Tepfers' concrete ring model is used to further analyse the splitting failure in ribbed steel bar and GFRP bar specimens. The angle the bond forces make with the bar axis was calculated and used for comparing bond behaviour of ribbed steel bar and GFRP bars in AAC concrete. The results showed that bond failure mode plays a significant role in the comparison of the average bond stress of the specimens at failure. In case of pull-out failure mode, specimens with ribbed steel bars showed a higher bond strength while specimens with GFRP bars showed a higher bond stress in case of splitting failure mode. Comparison of the bond stress-slip curves of ribbed steel bars and GFRP bars depicted that the constant bond stress region at the peak is much smaller in case of GFRP bars than ribbed steel bars indicating a basic bond mechanism difference in GFRP and ribbed steel bars.

Non-destructive evaluation of steel and GFRP reinforced beams using AE and DIC techniques

  • Sharma, Gaurav;Sharma, Shruti;Sharma, Sandeep K.
    • Structural Engineering and Mechanics
    • /
    • v.77 no.5
    • /
    • pp.637-650
    • /
    • 2021
  • The paper presents an investigation of the widely varying mechanical performance and behaviour of steel and Glass Fibre Reinforced Polymer (GFRP) reinforced concrete beams using non-destructive techniques of Acoustic Emission (AE) and Digital Image Correlation (DIC) under four-point bending. Laboratory experiments are performed on both differently reinforced concrete beams with 0.33%, 0.52% and 1.11% of tension reinforcement against balanced section. The results show that the ultimate load-carrying capacity increases with an increase in tensile reinforcement in both cases. In addition to that, AE waveform parameters of amplitude and number of AE hits successfully correlates and picks up the divergent mechanism of cracking initiation and progression of failure in steel reinforced and GFRP reinforced concrete beams. AE activity is about 20-30% more in GFRP-RC beams as compared to steel-RC beams. It was primarily due to the lower modulus of elasticity of GFRP bars leading to much larger ductility and deflections as compared to steel-RC beams. Furthermore, AE XY event plots and longitudinal strain profiles using DIC gives an online and real-time visual display of progressive AE activity and strains respectively to efficaciously depict the crack evolution and their advancement in steel-RC and GFRP-RC beams which show a close matching with the micro-and macro-cracks visually observed in the actual beams at various stages of loading.

A Study on Structural Design and Analysis of Composite Fairing to Reduce Air Resistance (공기 저항력 저감을 위한 복합재 페어링 구조 설계 및 해석 연구)

  • Yonggyu, Lee;Hyunbum, Park
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.6
    • /
    • pp.64-73
    • /
    • 2022
  • This study aimed to design a 3D fairing shape to reduce the air resistance of commercial vehicles. Rankine Half Body was applied to design the fairing shape, and the design was verified through aerodynamic analysis. Aerodynamic loads were calculated considering the speed conditions of commercial vehicles and gust conditions to ensure the structural safety of the fairing. A glass fibre/epoxy composite material was used to design a fairing structure that satisfied the safety factor 3. The structural safety of the lightest fairing was confirmed through structural analysis.

Flexural behaviour of GFRP reinforced concrete beams under cyclic loading

  • Murthy, A. Ramachandra;Gandhi, P.;Pukazhendhi, D.M.;Samuel, F. Giftson;Vishnuvardhan, S.
    • Structural Engineering and Mechanics
    • /
    • v.84 no.3
    • /
    • pp.361-373
    • /
    • 2022
  • This paper examines the flexural performance of concrete beams reinforced with glass fibre-reinforced polymer (GFRP) bars under fatigue loading. Experiments were carried out on concrete beams of size 1500×200×100 mm reinforced with 10 mm and 13 mm diameter GFRP bars under fatigue loading. Experimental investigations revealed that fatigue loading affects both strength and serviceability properties of GFRP reinforced concrete. Experimental results indicated that (i) the concrete beams experienced increase in deflection with increase in number of cycles and failed suddenly due to snapping of rebars and (ii) the fatigue life of concrete beams drastically decreased with increase in stress level. Analytical model presented a procedure for predicting the deflection of concrete beams reinforced with GFRP bars under cyclic loading. Deflection of concrete beams was computed by considering the aspects such as stiffness degradation, force equilibrium equations and effective moment of inertia. Nonlinear finite element (FE) analysis was performed on concrete beams reinforced with GFRP bars. Appropriate constitutive relationships for concrete and GFRP bars were considered in the numerical modelling. Concrete non linearity has been accounted through concrete damage plasticity model available in ABAQUS. Deflection versus number of cycles obtained experimentally for various beams was compared with the analytical and numerical predictions. It was observed that the predicted values are comparable (less than 20% difference) with the corresponding experimental observations.

Comparison of the post cementation efficacy using different cements and methods (포스트 접착 시멘트의 종류와 적용 방법에 따른 접착 효율 비교)

  • Cho, Ok-In;Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.48 no.9
    • /
    • pp.680-687
    • /
    • 2010
  • The purpose of this study was to compare post cementation efficacy according to the different adhesive systems and cement delivery methods. A total of 40 extracted human single-rooted premolar teeth were randomly divided in four groups according to the two luting agents of Unicem applicap (3M ESPE, St. Paul, MN, USA) or Variolink II (Ivoclar Vivadent, Liechtenstein) and cement delivery methods of direct cement application or lentulo spiral application. After restoration using glass?fiber posts, the samples were embedded in acrylic resin. Three sections of 2 mm thickness were prepared from each specimen, and the post in each section was subjected to a push-out test. The data were analysed statistically at significant level of 95%. The Unicem had significantly higher push-out bond strength than Variolink and the lentulo spiral application made higher bond strength (p<0.05). Adhesive failure between cement and dentin was predominant in all groups. The Unicem of self-etch system and cement delivery using lentulo spiral showed clinically acceptable and comparable bonding strength for the fiber post.

Finite Element Modelling of Axially Compressed GFRP Cylindrical Panels (축방향으로 압축을 받는 GFRP 원통형 판넬의 유한요소 모델링)

  • Kim, Ki Du
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.15-25
    • /
    • 1993
  • In order to promote the efficient use of composite materials, effort is currently being directed at the development of design criteria for composite structures. Insofar as design against buckling is concerned, it is well known that, for metal shells, a key step is the definition of 'knockdown' factors on the elastic critical buckling stress accounting mainly for the influence of initial geometric imperfections. At present, the imperfection sensitivity of composite shells has not been explored in detail. Due to the large number of parameters influencing buckling response (considerably larger than for isotropic shells), a very large number of tests would be needed to quantify imperfection sensitivity experimentally. An alternative approach is to use validated numerical models for this task. Thus, the objective of this paper is to outline the underlying theory used in developing a composite shell element and to present results from a validation exercise and subsequently from a parametric study on axially loaded glass fibre-reinforced plastic (GFRP) curved panels using finite element modelling. Both eigenvalue and incremental analyses are performed, the latter including the effect of initial geometric imperfection shape and amplitude, and the results are used to estimate 'knockdown' factors for such panels.

  • PDF

A Study on Design of 500W Class High Efficiency Horizontal Axis Wind Turbine System(HAWTS) Blade Using Natural Fiber Composites (친환경 소재를 적용한 500W급 고효율 수평축 풍력터빈 블레이드 설계에 관한 연구)

  • Park, Gwanglim;Kong, Changduk;Lee, Haseung;Park, Hyunbum
    • Composites Research
    • /
    • v.28 no.3
    • /
    • pp.104-111
    • /
    • 2015
  • In this work, a structural design on 500W class horizontal axis wind turbine blade using natural-fibre composite is performed. The structural design result of flax composite blade is compared with the result of glass composite blade. The structural design of the wind turbine blade is carried out using the simplified methods such as the netting rule and the rule of mixture. The structural safety of the designed blade structure is investigated through the various load cases, stress, deformation and buckling analyses using the commercial FEM. The structural test of the manufactured prototype blade was performed to confirm the structural analysis results including strains, natural frequencies and deformations. According to the comparison results, it was confirmed that the analysis results are well agreed with the experimental results.