• 제목/요약/키워드: Geothermal anomaly

검색결과 23건 처리시간 0.023초

우리나라의 지열자원 분표 (Distribution of geothermal resources of Korea)

  • 김형찬;이철우;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.674-677
    • /
    • 2005
  • The characteristics of geothermal resources in Korea was roughly estimated using hot springs, 580 geothermal gradients and 338 heat flow data. In the aspect of hot springs with geologic structure, location of hot springs coincide with fault zone, especially younger age of Cretaceous to Tertiary. In the aspect of geothermal gradients, Pohang area shows the highest geothermal gradient anomaly, which is covered with unconsol idated rock of low thermal conductivity preserving the residual heat from igneous activity or radioactivity elements decay. In the aspect of heat flow density, high anomaly can be found along the zone connecting Uljin-Pohang-Busan on the southeastern part of Korean peninsula at which big fault zone as Yangsan fault is well developed.

  • PDF

경북 포항지역에서의 심부 지열수자원 개발 사례 (Development of deep-seated geothermal energy in the Pohang area, Korea)

  • 송윤호;이태종;김형찬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.693-696
    • /
    • 2005
  • KIGAM (Korea Institute of Geoscience and Mineral Resources) launched a new project to develop the low-temperature geothermal water in the area showing high geothermal anomaly, north of Pohang city, for large-scale space heating. Surface geologic and geophysical surveys including Landsat 1M image analysis, gravity, magnetic, Magnetotelluric (MT) and controlled-source audio-frequency MT (CSAMT), and self-potential (SP) methods have been conducted and the possible fracture zone was found that would serve as deeply connected geothermal water conduit. In 2004, two test wells of 1.1km and 1.5km depths have been drilled and various kinds of borehole survey including geophysical logging, pumping test, SP monitoring, core logging and sample analysis have followed. Temperature of geothermal water at the bottom of 1.5km borehole reached over $70^{\circ}C$ and the pumping test showed that the reservoir contained huge amount of geothermal water. Drilling for the production well of 2 km depth is on going. After test utilization and the feasibility study, geothermal water developed from the production well is going to be provided to nearby apartments.

  • PDF

지온경사 산출을 위한 효율적인 온도검층자료 이용방법 연구 (A study on the Effective Utilization of Temperature Logging Data for Calculating Geothermal Gradient)

  • 김형찬
    • 자원환경지질
    • /
    • 제32권5호
    • /
    • pp.503-517
    • /
    • 1999
  • The purpose of this study is to verfify a more effecive techique for calculating geothermal gradient. this study examines 370 data of temperature-logging having been collected since 1985. The daya are divided into three different grades grades according to the type of temperature-depth plots: 204 data show typical linear gradient (Grade A); 126 data do not explicitily show the gradient becase of various external effects such as water flow (Grade B); and the rest 40 data do not show the gradient at all (Grade D). The new technique for calculating geothermal gradient is to be required to use Greade-B data more effctiviely. This new technique includes (1) calculating the independer depth of atmospheric temperature in the earth; (2) drawing a distribution map of subsurface tempurature by using the distribution map of subsurface temperature by using Grade-A data at the independent depth; and (3) recalculating geothermal gradient of Grade-B data by using the distrbution map of subsurface temperature, borehole depth, and bottom temperature of Grade-B data by using the distribution map of subsurface temperature, borehole depth, and bottom temperature of Grade-B data. As a result, 330 data-both Grade-A and Grade-B data--can be used to draw a distribution map of hot spradient. The map clearly distinguishes anomaly areas, and helps interpret their relations to the distribution of hot springs, geology, geological structures, and geophysical anomaly areas. These new results reveal that the average of geothermal in south Korea is 25.6$^{\circ}C$/km, when calculated to the Kriging method.

  • PDF

유성온천지역의 지질구조 및 지온분포 연구 (Characterization on the Geological Structures and Geothermal Gradient Distribution in the Yusong Area)

  • 정지곤;서만철;김경수;황형중
    • 지질공학
    • /
    • 제7권3호
    • /
    • pp.173-189
    • /
    • 1997
  • 유성온천장을 중심으로 불측 인접지역에서의 온천개발 가능성을 평가하기 위하여 주변의 지질구조와 지온분포에 관한 연구를 시도하였다. 연구지역 주변지역에서 온천수 형셩과 관련된 요인은 단층과 암맥이며 물탐자료와 지온측정자료 해석결과는 이를 어느 정도 뒷받침하고 있다. EW 예상 단층선은 본 지역의 북부를 스쳐 지나가며 N40$^{\circ}$W 예상 단층선은 본 지역의 서측에서 EW의 예상 단층과 교차한다. 이러한 예상 단측의 위지는 선구조선의 분석, 물탐자료 및 자료 및 지온측정의 결과에서 잘 반영된다. 연구지역 내에는 3개조의 암맥이 관입되어 있는 것으로 판단된다. 지온측정 결과 지온 이상대와 암맥의 위치는 서로 일치하며, 지하 1m와 0.5m 사이의 온도차는 3$^{\circ}C$ 이상이다. 지하 1m와 0.5m 사이의 온도차는 2.5$^{\circ}C$ 이상의 지온 이상대는 연구지역 내에서 N80$^{\circ}$W의 방향으로 형성되어 있다. 암맥의 경사는 암맥의 직선적인 분포나 노두에서의 조사결과로부터 거의 수직인 것으로 판단된다. 온도 이상대 분포와 암맥의 위치로부터 연구지역 내에서 온천수 부존 가능 위치로 세곳을 들을 수 있으며 이들 지점에서 4$0^{\circ}C$ 이상의 온천수를 확보할 수 있는 깊이는 170~200m 내외로 추정된다.

  • PDF

지열자료 정보 D/B 구축 요소 (Geothermal properties for Database)

  • 김형찬;박정민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.28-31
    • /
    • 2006
  • It is require to construct geothermal database to develop geothermal energy as renewable energy policy. It must be consist of geologic data, borehole data and geophysical data for geothermal database. In aspect of geology, there are included the distribution of geology, structural geology, geological time, rock name, density of rock, porosity, thermal diffusivity, specific capacity and thermal conductivity In order to calculate the heat general ion, it is needed to analysis the radioactivity elements as U, Th and K of rock. In aspect of borehole data, there are included temperature of depth, surface temperature and geothermal gradient And also there is geotherrnornetry using chemical components of groundwater as Na Ca, K and $SiO_2$. In aspect of geophysical data, there are some thematic map as booger gravity anomaly data and magnetic survey data and etc. In addition, it is important to descript the distribution of hot spring and water temperature.

  • PDF

EGS 지열 저류층 유체 유동에 의한 SP 반응 모델링 (Modeling of SP responses for geothermal-fluid flow within EGS reservoir)

  • 송서영;김빛나래;남명진;임성근
    • 지구물리와물리탐사
    • /
    • 제18권4호
    • /
    • pp.223-231
    • /
    • 2015
  • 자연 전위(SP, self-potential)의 발생에는 여러 요인이 있으나 이 연구에서는 지하수의 유동에 의해 자연적으로 발생하는 유동 전위(streaming potential) 또는 전기역학적 전위(electrokinetic potential)에 대해 주로 논의한다. 유동 전위는 다공질 매질에서의 물의 흐름에 의해 인공적인 전류원 없이 전류가 발생하여 야기된 전위이다. 기존의 유동 전위를 이용한 지열 저류층 해석에서는 지표면 전위 분포 계산을 위해 일반적으로 시추공에서 주입되거나 생산되는 지하수로부터 발생하는 SP 이상만을 고려하였고, 온도 차이가 나는 지열 저류층에서의 지열수 순환에 따라 발생할 수 있는 SP에 대한 수치 모델링에는 한계가 있었다. 이에 따라 사면체 요소를 바탕으로 한 3차원 전기비저항 유한요소법에 기초하여 지열 저류층 내에서의 주입정, 생산정에 의한 SP 이상뿐만 아니라 지열 저류층에서의 지열수 순환에 따른 SP 이상까지 고려할 수 있는 알고리듬을 개발하였다. 본 논문에서는 개발한 알고리듬을 검증 한 후, 간단한 지열 저류층 모델에 지열수 주입과 양수의 효과에 의한 SP 이상대의 SP 반응을 분석하였다. 향후 개발한 알고리듬을 이용하여 지층의 물성을 고려한 지열수 유동 속도 등도 고려함으로써 보다 심도 있게 지열 저류층 SP 반응을 분석하고자 한다.

제주도 중산간 지역 MT 및 AMT 탐사자료의 2차원 역산 (A two-dimensional inversion of MT and AMT data from mid-mountain area of Jeiu island)

  • 이태종;송윤호;우치다토시히로;박인화;임성근
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 공동학술대회 논문집
    • /
    • pp.21-26
    • /
    • 2005
  • 제주도 중산간 지역에서 자기지전류 (MT) 및 가청주파수대역 자기지전류 (AMT) 탐사자료를 얻고 이를 이용하여 2차원 역산을 수행하였다. 두 개의 남-북 방향 측선에 대한 역산결과 제주도에서 특징적으로 나타나는 미고결 퇴적층이 10 ohm-m 내외로 두 개의 측선 전반에 걸쳐 나타났으며 측선 중앙부에서 4 km 이상의 심도까지 연장된 저비저항 이상대가 존재하는 것으로 나타났다. 그러나 이 저비저항 이상대가 제주도 주변 바다의 영향인지 과거의 화산활동과 관련된 것인지에 대한 해석을 뒷받침해 줄 어떠한 정보도 아직은 확보되지 않아 향후 추가적인 연구가 요구된다. MT 주파수대만을 이용한 경우와 이것에 AMT 주파수대를 포함해서 역산을 수행한 경우를 비교한 결과, 우리나라와 같이 전기비저항이 높은 지질구조에서는 AMT 자료를 함께 얻어 천부 분해능을 확보하는 것이 심부구조 해석에 도움이 되는 것으로 나타났다.

  • PDF

포항 지열 개발지역에서의 지열 저류층에 대한 SP 모델링

  • 임성근;이태종;송윤호;;송영수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.417-421
    • /
    • 2004
  • Self-potential (SP) survey was carried out at Pohang geothermal field. SP measurement showed clear positive anomaly at northern part of the test wells, which can be a up-flow zone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. To give a clearer image of the fluid flow pattern around the test wells, a two-dimensional numerical simulation was applied to construct a numerical block model of the fluid flow system based on SP and magnetotelluric survey results. The result suggests existence of two high permeability zones including the main manifestation area in the northern part of the test wells.

  • PDF

심부 지열에너지 개발 가능성 파악을 위한 제주도 증산간 지역에서의 MT 탐사 (Magnetotelluric surveys from mid-mountain area of Jeju Island for evaluating possible structures for deep-seated geothermal energy)

  • 이태종;이성곤;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.434-437
    • /
    • 2006
  • Though numerous drilling has been performed in Jeju Island for development of ground water, the wells are mostly located along the coast lines or at low altitude area, and can hardly be found on the mid-mountain area. Two-dimensional magnetotelluric (MT) surveys have been carried out to cover the lack of geological Informal ion on the mid-mountain area and to figure out any possible structures or evidences for deep geothermal energy remained. Two-dimensional (2-D) inversion of MT data for four survey lines surrounding the Halla mountain show a thick layer having around 10 ohm-m in the depth of a few hundred meters throughout the survey area, which can be considered as the unconsol idated sedimentary layer. And they also show a conductive anomaly extending to more than 2km depth at the central part of each survey lines, which can possibly be related with old volcanic activities during the formation of Halla Mt.. Further seological/geophysical investigations should be followed.

  • PDF

유한요소법을 이용한 전자탐사 토모그래피 연구 (Electromagnetic Tomography Using Finite Element Method)

  • 손정술;송윤호;김정호
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.185-190
    • /
    • 2007
  • In this study, we developed the 2.5D EM modeling and inversion algorithm for cross-hole source and receiver geometry. Considering the cross-hole environment, we use a VMD (vertical magnetic dipole) as a source and vertical magnetic fields as a measuring data. Developed inversion algorithm is tested for the isolated block model which has a conductive and a resistivity anomaly respectively. For the conductive anomaly, its size and resistivity are inverted well on the inversion results, while for the resistive anomaly, the location of anomalous block is shown on the inverted section, but its values are far from the exact value. Furthermore, artificial conductive anomalies are shown around the resistive anomalous zone. If we consider the inversion artifact shown in the test inversion of restive block, it is almost impossible to image the resistive zone. However, the main target of EM tomography in the engineering problem is conductive target such as fault zone, and contaminated zone etc., EM tomography algorithm can be used for detecting the anomalous zone.

  • PDF