• 제목/요약/키워드: Geothermal Heat Pump System

검색결과 286건 처리시간 0.026초

군사시설 내 지열 히트펌프 시스템 적용에 따른 에너지 성능과 비용 절감 효과 평가 (Energy Performance and Cost Assessment for Implementing GroundSource Heat Pump System in Military Building)

  • 손병후;조경주;조동우
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.45-57
    • /
    • 2022
  • The Ministry of National Defense of the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of military facilities and to promote green growth policy in military sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. This paper analyzed energy performance and energy cost on the conventional heating and cooling system (baseline scenario) and three different alternative scenarios (ALT 1, ALT 2 and ALT 3) applied in a hypothetical military building. A building modeling and simulation software (DesignBuilder V6.1) with EnergyPlus calculation engine was used to calculate the energy consumption for each scenario. Overall, when the GSHPs are applied to both space airconditioning and domestic hot water (DHW) production, Alt-2 and Alt-3, the amount of energy consumption for target building can be greatly reduced. In addition, when the building envelope performance is increased like Alt-3, the energy consumption can be further reduced. The annual energy cost analysis showed that the baseline was approximately 161 million KRW, while Alt-3 was approximately 33 million KRW. Therefore, it was analyzed that the initial construction cost increase could be recovered within about 6.7 years for ALT 3. The results of this study can help decision-makers to determine the optimal strategy for implementing GSHP systems in military buildings through energy performance and initial construction cost assessment.

수치해석을 통한 수직 밀폐형 지중열 교환기의 열전달 거동 연구 (Thermal Behavior of Vertical Ground Heat Exchanger by Numerical Simulation)

  • 길후정;이철호;김주영;최항석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1638-1646
    • /
    • 2008
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 2-D finite element analysis, ANSYS, was employed to evaluate the temperature distribution on the borehole cross section involving HDPE pipe/grout/soil formation to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system which is equipped with a thermally insulating latice in order to reduce thermal interference between the inflow and outflow pipes. In addition, a 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of grout's thermal properties, rate of circulation pump, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Ground Heat Exchanger to the Overall Thermal Conductivity)

  • 공형진;임효재;최재호;손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.45-51
    • /
    • 2009
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

현장타설말뚝형 에너지 파일의 시공형태별 지중 열교환량에 관한 연구 (The Effect of Construction Methods on Geothermal Exchange Rates of Cast-in-place Energy Piles)

  • 박용부;남유진;심영종;손정락
    • 토지주택연구
    • /
    • 제3권2호
    • /
    • pp.169-175
    • /
    • 2012
  • 최근, 지열 냉난방 시스템의 초기 공사비를 절감하기 위해 연구되고 있는 에너지 파일의 열교환량을 산정하기 위해 2종류(부속연결형, 슬링키형)의 현장타설말뚝형(PRD, 시공심도 4.5m, 직경 1,200mm) 에너지 파일을 시험시공하고 수치 시뮬레이션에 의해 효율을 상호 비교하였다. 상호 비교결과에 의하면 지중 교환량은 운전시작과 함께 채열에 의한 지중온도의 저하에 의해 점점 감소하였고 부속연결형의 평균 열원수의 온도차는 난방운전에서 $0.37^{\circ}C$, 냉방운전에서 $0.34^{\circ}C$로 나타났다. 또, 부속연결형의 난방운전시 열교환량 231.4W/m보다 냉방운전의 방열량은 252.2W/m로서 9% 높았고 슬링키형은 난방 기간 평균 열교환량이 168.0W/m로 부속연결형에 비해 약 27% 낮은 열교환량을 얻었다.

사무시설에 수직형 지열원 냉 난방시스템의 경제성을 고려한 인입온도(EWT)에 관한 연구 (A Study on Entering Water Temperature in Vertical Closed Ground Loop System Considering the Economical Feasibility in Load of the Office Building)

  • 이병두;이대우;이세진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.579-585
    • /
    • 2009
  • Recently, Vertical-Closed Loop system using geothermal which is the most efficient among the building cooling and heating systems is coming into wide spread due to assistance of domestic policies. However, there is a limitation that a design of ground heat exchanger taking 60% of construction cost is done by GLD and GLHEPRO programs without specific guidelines and consideration on Entering Water Temperature(EWT). For getting an optimal EWT, we analyzed the costs for construction of ground heat exchanger and cooling and heating for 15 years. In the results, reduction of construction costs as the length of ground heat exchanger shortens was much greater than increase of the electrical power consumption as COP gets low. EWT that COP of heat pump can be 3.76 or above was below $31^{\circ}C$ in cooling and was over $5^{\circ}C$ in heating.

  • PDF

MW급 EGS 지열발전 상용화 기술개발사업의 추진 배경 및 계획 (Research Background and Plan of Enhanced Geothermal System Project for MW Power Generation in Korea)

  • 윤운상;송윤호;이태종;김광염;민기복;조용희;전종욱
    • 터널과지하공간
    • /
    • 제21권1호
    • /
    • pp.11-19
    • /
    • 2011
  • 지열에너지는 여러 신재생에너지원 중에서도 기저부하를 담당할 수 있는 중요한 자원으로 인식되고 있다. 국내에서도 천부지열을 이용한 지열냉난방은 효율 높은 신재생에너지 활용 사업으로 그 보급이 활성화 되어 있다. 반면, 전세계적으로 지열 발전 기술이 진일보하고, 그 시장이 크게 확대되고 있는 상황에서 아직까지 국내의 심부 지열을 이용한 지열 발전 기술은 낮은 단계에 머무르고 있다. 이러한 조건에서 2010년 12월에 국내 최초의 EGS(Enhanced Geothermal System) 지열 발전 상용화 기술 개발 과제가 착수되었다. 총 5개년의 기간으로 수행되는 이 과제는 2단계로 구분되어 진행될 계획이다. 처음 2년의 1단계에서는 3 km 심도에서 최소 $100^{\circ}C$의 지열저류층 온도를 확인하는 것을 주요 과제 내용으로 하여 지중 지열수 순환시스템의 설계가 이루어질 예정이다. 이후 3년을 통해 수행될 2단계에서는 5 km 심도의 생산정과 주입정 등 두 개의 지열발전정을 설치하고, 수리자극을 통하여 온도 $180^{\circ}C$의 지열저류층에서 유량 40 kg/s 이상의 지열수를 활용하는 MW급 지열발전소를 건립 운영하게 된다. 이 사업을 성공적으로 추진하기 위하여 현재 지질, 수리지질, 지구물리, 암석역학, 플랜트 엔지니어링 등 다양한 분야의 산학연 연구 기관 등이 망라되어 연구진을 구성한 상태이며, 이후 관심있는 여러 기관과 연구자들의 지원과 참여를 기대하고 있다.

수주지열정(SCW)을 이용한 천부지열 냉난방시스템 설계지침 (Design Guidlines of Geothermal Heat Pump System Using Standing Column Well)

  • 한정상;한혁상;한찬;김형수;전재수
    • 자원환경지질
    • /
    • 제39권5호
    • /
    • pp.607-613
    • /
    • 2006
  • 내 수문지열계 가운데 수주지열정(SCW)시스템을 합리적으로 설치이용할 수 있는 조건들은 심도별 지온증가율이 명확하고($2^{\circ}C/100m$심도), 기존의 지하수 열펌프가 필요로 하는 순환수의 유량에 비해 최소 $10{\sim}30%$의 중온의 심부지하수가 산출될 수 있어야 하며, 순환수를 공내로 재주입시 공내붕괴가 일어나지 않는 견고한 암석들이 존재 하여야 한다. 수주지열정의 1개공당 굴착심도는 평균 $400{\sim}500m$이며, 이로 부터 개발가능한 지열에너지는 공당 약 $30{\sim}40RT$ 규모인데 비해 1개 수직지중열교환기가 공급가능한 지열에너지는 $2{\sim}3RT$ 정도이다. 즉 수주지열정 1개공은 $10{\sim}15$개의 수직지중열교환기 역할을 한다. 따라서 이 방식은 수직루프 설치장소의 공간 문제를 해소할 수 있는 유일한 대안으로 인식되어, 현재 전국 각지에서 많은 수의 SCW들이 무분별 하게 비과학적으로 설치되고 있다. 이와 같이 해당지역 수문지열계의 수리 지질학적인 특성과 열적인 특성을 명확히 파악하지 않은 상태에서 수주지열정을 설계 시공하는 경우에 나타날 문제점들은 추후 합리적인 천부지열 개발 이용에 지대한 장애요인이 될 것이다. 따라서 본고는 국내 수문지열계에 적합한 수주지열정을 설계 하는데 있어 필요한 일종의 지침서를 제시하기 위해 작성되었다.

지중 유효 열전도도의 지역별 분포 (A Study on Regional Distribution of the Ground Effective Thermal Conductivity)

  • 공형진;권순기;지승규
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.43-47
    • /
    • 2016
  • 지열 히트펌프 시스템은 환경 친화적이고 에너지 절감 시스템으로 알려져 있다. 특히 지중 열교환기는 초기투자비와 시스템 성능을 결정하는 매우 중요한 요소다. 수직형 지열 시스템 설계를 위해서는 현장 열응답 테스트를 통해 지중 유효 열저항을 고려해야 한다. 본 연구에서는 지열이용검토서를 통해 접수된 전국의 지중 열전도도를 지역별로 분석하였다. 전국 평균 지중 열전도도는 2.56 W/mK로 분석되었다. 지중 열전도도가 가장 높은 지역은 서울로 평균 2.68 W/mK이고, 가장 낮은 지역은 부산으로 2.28 W/mK다. 또한 해안을 접하고 있는 지역의 열전도도는 전국 평균에 비해 약 30% 낮다.

열펌프의 고장감지 및 진단시스템 구축을 위한 실시간 정상상태 진단기법 개발 (Real-time steady state identification technology of a heat pump system to develop fault detection and diagnosis system)

  • 김민성;윤석호;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.282-287
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF

수직밀패형 지중열교환기의 설계인자가 보어홀 전열저항에 미치는 영향에 관한 연구 (A Study on the Effects of Design Parameters of Vertical Ground Heat Exchanger on the Borehole Thermal Resistance)

  • 장근선;김민준
    • 한국산학기술학회논문지
    • /
    • 제19권10호
    • /
    • pp.128-135
    • /
    • 2018
  • 현재 지열 열펌프 시스템에 수직밀폐형 지중열교환기가 가장 많이 적용되고 있으며, 수직밀폐형 지중열교환기의 성능에 영향을 미치는 주요 인자로는 지중 열전도율(k)과 보어홀 전열저항($R_b$)이 있다. 본 연구에서는 현장에서 측정된 열응답시험 데이터를 이용하여 보어홀 전열저항을 계산하였으며 지중열교환기 개별 설계인자들(순환수유량, 파이프 수, 그라우팅재)이 보어홀 전열저항에 미치는 영향을 분석하였다. 또한 도출된 그라우팅 열저항은 문헌에 제시된 다양한 상관식과 비교 분석하였다. 시험데이터를 통해 본 시험에서의 지중열교환기 보어홀 전열저항은 0.1303 W/m.K로 나타났으며, 보어홀 전열저항에서 그라우트 열저항이 66.6 %, 파이프 열저항이 31.5 %, 순환수 대류열저항이 1.9 %를 차지하여 그라우트가 보어홀 열전달에 가장 큰 영향을 미치는 인자임을 확인하였다. 또한 각 설계인자의 설계변수가 보어홀 전열저항에 미치는 영향을 분석한 결과 실리카샌드를 혼합하여 그라우트 열전도율를 높이는 방법이 파이프 수 증가나 순환수 유량증가보다 열전달 증진에 더 효과적임을 알 수 있었다.