• 제목/요약/키워드: Geometric standard deviation

검색결과 101건 처리시간 0.025초

불검출 자료를 포함한 작업환경측정 자료의 분석 방법 비교 (A Comparison of Analysis Methods for Work Environment Measurement Databases Including Left-censored Data)

  • 박주현;최상준;고동희;박동욱;성예지
    • 한국산업보건학회지
    • /
    • 제32권1호
    • /
    • pp.21-30
    • /
    • 2022
  • Objectives: The purpose of this study is to suggest an optimal method by comparing the analysis methods of work environment measurement datasets including left-censored data where one or more measurements are below the limit of detection (LOD). Methods: A computer program was used to generate left-censored datasets for various combinations of censoring rate (1% to 90%) and sample size (30 to 300). For the analysis of the censored data, the simple substitution method (LOD/2), β-substitution method, maximum likelihood estimation (MLE) method, Bayesian method, and regression on order statistics (ROS)were all compared. Each method was used to estimate four parameters of the log-normal distribution: (1) geometric mean (GM), (2) geometric standard deviation (GSD), (3) 95th percentile (X95), and (4) arithmetic mean (AM) for the censored dataset. The performance of each method was evaluated using relative bias and relative root mean squared error (rMSE). Results: In the case of the largest sample size (n=300), when the censoring rate was less than 40%, the relative bias and rMSE were small for all five methods. When the censoring rate was large (70%, 90%), the simple substitution method was inappropriate because the relative bias was the largest, regardless of the sample size. When the sample size was small and the censoring rate was large, the Bayesian method, the β-substitution method, and the MLE method showed the smallest relative bias. Conclusions: The accuracy and precision of all methods tended to increase as the sample size was larger and the censoring rate was smaller. The simple substitution method was inappropriate when the censoring rate was high, and the β-substitution method, MLE method, and Bayesian method can be widely applied.

고농도 수은 노출자의 혈 중 및 뇨 중 수은 농도 변화에 관한 연구 (Patterns of Mercury Concentrations in Blood and Urine After High Mercury Exposure)

  • 윤충식;임상혁;하권철
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.71-80
    • /
    • 2001
  • Blood and urine mercury level of three workers were monitored during 60~80 days after high exposure to mercury at the silver refining plant. Mercury was used to form silver-mercury amalgam from plating sludge. Workers were exposed to mercury about 70 days at the several processes, such as hand held weaving, vibration table, and heating from the furnace. mercury was analysed by atomic absorption spectroscopy-vapor generation technique. Recovery from the biological sample was 95.51% and pooled standard deviation was 0.033. At the time of study, there was no work at the workplace. So, airborne mercury concentration was measured with area sampling 5 days after the work, ranged from 0.1459 to 1.2351 mg/㎥(Arithmatic mean 0.4711 mg/㎥, Geometric mean 0.3566 mg/㎥) at the inside of the plant, that is far above the ACGIH's TLV(0.025 mg/㎥) and ranged from 0.0073 to 0.0330 mg/㎥ at the outdoor. Blood mercury levels at the beginning of the monitoring were 4~14 times greater than the American Conference of Governmental Industrial Hygienists Biological Exposure Index(ACGIH BEI, 15 ug/L). Blood mercury levels were decreased logarithmically, that is, rapidly at the high level and slowly at the low level but sustained above the level of the ACGIH BEI 60~80 days after the work. Urine mercury levels at the beginning of the monitoring were 8~16 times greater than the ACGIH BEI(35 ug/g creatinine). Urine mercury levels were decreased logarithmically, but correlation between urine level and off-days were lower than those of blood. Decreasing pattern of blood mercury levels were little affected than that of urine levels when the chelating agent, D-penicillamine, was administered. There was correlation between blood mercury level and urine mercury level(0.81~0.83) but it didn\`t mean that the highest blood mercury level corresponded the highest urine mercury level. In our study, Case 1 always shows the highest level in urine but case 3 always shows the highest level in blood. Creatinine correction represented better correlations between urine mercury levels and blood levels, and between urine levels and off-days rather than by urine volume. Spot urine sampling had a wide variation than that of whole day urine sampling. So, We recommend spot urine sampling for screening and whole day urine sampling for exact diagnosis.

  • PDF

인체기관지내의 입자펄스 확산 실험 (Dispersion of Particle Pulse in Human Lung Airway)

  • 이진원;이동엽;추경호
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권5호
    • /
    • pp.511-518
    • /
    • 1998
  • 세기관지의 구조와 이상유무의 신속 정확한 측정을 위해 세계적으로 활발히 연구되고 있는 에어로졸볼러스기법을 확립하기 위하여, 호흡과정 중 흡기에 공급된 입자펄스가 호흡의 진행에 따라 인체기관지내에서 대류분산된 결과로 호기중 입자농도의 증가된 분포폭을 측정하는 장치를 개발하고 이를 이용한 검증실험을 수행하였다. 개발된 장치는 인체에 무해한 sebacic acid를 이용하여 평균입경이 1 $\mu$m이고 기하표준편차가 1.2정도인 임자를 $10^{9}$개/cc 정도의 고농도로 발생하고, 솔레노이드밸브를 이용하여 호흡중의 원하는 시점에 정확히 짧은 펄스형태로 입자를 공급하며, 레이저광산란을 이용하여 흡기와 호기중의 입자농도의 시간변화를 측정한다. 흡기중의 농도분포는 매우 매끈한 분포를 보임으로써 발생장치와 측정장치의 정강작동은 잘 검증되었다. 농도의 시간변화 측정치로부터 계산된 분산도를 1차원 대류확산방정식 이론치 및 외국에서 보고된 실험결과와 비교한 격과, 입자도달깊이에 따른 분산도의 변화에 대한 정성적인 실험결과는 이론치와 상당히 잘 일치하고 기존의 결과보다도 견과의 산포가 개선되었다. 다만 아직도 산포가 상당히 남아있어 개선의 여지를 가지고 있으며, 외국 결과와의 분산도의 타이는 신체조건의 타이 등으로 파악되었다. 산포도의 개선을 위해서는 호흡시에, 특히 최고농도점 부근에서, 호흡유량이 일정하게 유지되어야만 불규칙 이차파형의 형성을 방지하여 측정결과의 해석에 오차를 줄일 수 있음을 확인하였다.

  • PDF

Bit-dropping에 의한 Overload Control 방식을 채용한 Packet Voice Multiplexer의 성능 분석에 관한 연구 (Performance Analysis of a Packet Voice Multiplexer Using the Overload Control Strategy by Bit Dropping)

  • 우준석;은종관
    • 한국통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.110-122
    • /
    • 1993
  • 음성이 패킷망을 통해 전송될때 각각의 call들에 의해서 발생되는 패킷들은 statistical multiplexer에 의해 다중화 되는데 이때 overload control이 필요하다. Overload control 방식은 음성 traffic을 coding하는 방식과 밀접한 관계가 있으며 그동안 많은 연구가 진행되어 왔다. CCITT에서는 최근에 packetized voice protocol에 대한 권고안 초안인 G.764를 작성하였는데 여기에서 embedded coding을 사용하는 경우에 bit dropping 방식을 사용하면 매우 훌륭하게 overload control을 할 수 있다는 사실을 언급하였다. 이에 따라 본 논문에서는 음성을 embedded ADPCM으로 coding하여 CCITT권고안 G.764에 따라 전송하는 경우에, bit dropping 방식에 따른 overload control 방식을 사용하는 패킷 multiplexer의 성능을 분석하고자 한다. 성능 분석을 위해서는 먼저 multiplexer에 도착하는 중첩된 packet arrival process에서 패킷들의 interarrival time들 간에 존재하는 큰 correlation을 정확히 나타낼 수 있는 수학적인 model이 필요하다. 본 논문에서는 Poisson process나 birth-and-death process에 비해 이들 packet arrival process를 상대적으로 정확히 표현할 수 있는 Makov-modulated Poisson Process(MMPP)를 사용하여 모델링을 하였다.따라서 성능분석은 MMPP/G/1 queueing system에 대한 분석과 비슷하다. 다만 서비스 시간의 분포가 시스템의 상태에 따라 달라지는데 이러한 경우에 대해서는 기존의 논문에서 분석되지 않았다. 성능분석을 통하여 queue에서 서비스를 기다리는 패킷의 수에 대한 분포의 Z-transform을 구하고 이를 이용하여 임의의 시간에서의 queue length와 waiting time의 평균과 표준편차를 구하였다. 이를 통하여 bit dropping 방식에 의한 overload control이 음성의 질을 많이 저하시키지 않으면서도 overload control을 하지 않을 때에 비해 statistical multiplexer에서 훨씬 많은 수의 call을 수용할 수 있도록 하는 효과를 가진다는 사실을 확인 하였다. 또한 패킷이 queue에서 떠난 직후와 임의의 시간에서 구한 queue length와 waiting time의 평균과 표준편차가 매우 비슷하다는 사실을 알 수 있었다. 본 논문에서와 마찬가지로 임의의 시간에서의 분석은 매우 복잡한 경우가 대부분이므로 이러한 사실을 이용하면 매우 간단히 성능분석을 할 수 있을 것이다.

  • PDF

정사보정량 계산을 위한 Ortho-Calc v1.0 프로그램의 개발과 검증 (Development and Inspection of the Ortho-Calc v1.0 Program for the Calculation of the Orthometric Correction)

  • 이석배;심정민
    • 대한공간정보학회지
    • /
    • 제23권3호
    • /
    • pp.41-47
    • /
    • 2015
  • 표고를 정확하게 결정하기 위해서는 수준측량에 의해 얻게 되는 기하학적 표고차뿐만 아니라 중력의 차이에 의한 물리적인 표고차를 고려해 주어야 하는데 이것이 정사보정량이다. 정사보정량은 평탄지에서는 무시할 정도로 그 양이 작으나 표고가 높은 산악지에서는 그 양을 고려해 주어야만 정확한 표고를 산출할 수 있으며, 계산과정이 복잡하여 쉽게 계산할 수 없는 어려움이 있다. 본 연구에서는 이러한 정사보정량을 쉽게 계산할 수 있도록 비주얼 베이직 프로그램을 이용한 사용자 친화형 프로그램 Ortho-Calc. v1.0을 개발하였다. Nassar와 Hwang & Hsiao, 그리고 Strang Van Hees의 알고리즘을 이용하여 정사보정량을 선택적으로 계산할 수 있도록 하였으며 결과를 검증한 결과 기존 연구결과와 표준편차 0.024mm의 높은 정밀도를 나타내었다. 따라서 본 연구에서 개발한 정사보정량 계산 프로그램 Ortho-Calc. v1.0 프로그램이 널리 보금되어 활용된다면 정사보정량 계산을 빠르고 쉽게 할 수 있도록 기여할 것이며 우리나라의 정표고 성과 고시에도 기여할 수 있을 것으로 기대된다.

치과기공소 주조체 산세척과정에서 발생하는 폐수내 중금속 농도 (A Study on Heavy Metal Concentrations in Waste Water Produced in the Casting Pickling Process at Dental Technical Laboratories)

  • 정다이;사공준
    • 한국환경보건학회지
    • /
    • 제44권1호
    • /
    • pp.55-62
    • /
    • 2018
  • Objectives: This study set out to measure the heavy metal concentrations in waste water produced in the casting pickling process at dental technical laboratories and examine the actual state of its treatment. Methods:The investigator measured the concentrations of each heavy metal at 55 dental technical laboratories using an inductively coupled plasma optical emission system. Results: The annual usage of electrolytes was under 10 L in 50 (90.9%), and was 10L or more in five (9.1%) laboratories. Among the laboratories, 15 (27.3%) commissioned the treatment of waste,12 (21.8%) treated the waste with general sewage,and 28 (50.9%) treated the waste in aseptic tank. The arithmetic $mean{\pm}standard$ deviation and the geometric mean of chrome(Cr) were $75.3{\pm}50.9$ and 58.3 mg/L; those of cobalt (Co) were $112.3{\pm}106.7$ and 66.1 mg/L; those of nickel (Ni) were $62.9{\pm}83.5$ and 8.9 mg/L; those of molybdenum (Mo) were $17.1{\pm}13.4$ and 12.0 mg/L; those of iron (Fe) were $31.5{\pm}44.1$ and 6.2 mg/L; those of lead (Pb) were $0.3{\pm}0.3$ and 0.3 mg/L; those of beryllium (Be) were $3.6{\pm}3.6$ and 2.0 mg/L. The hydrogen ion concentration was under pH 2 across all the samples. Conclusions: The findings show that the dental technical laboratories were not doing well with the separation, storage, collection, and treatment of the electrolytes they discarded, and that most of the electrolytes were introduced through the general sewage or aseptic tank. The causes of this include alack of perception among the practitioners at dental technical laboratories and contracted companies avoiding collection for economic reasons. There is a need for education to improve the perceptions of waste water treatment among the practitioners at dental technical laboratories. Environment-related departments should be stricter with legal applications in the central and local governments. It is also required to provide proper management of commissioned treatment.

Comparison of pharmacokinetic characteristics of sildenafil citrate chewable tablets and film-coated tablets in healthy male subjects

  • Yoo, Hyounggyoon;Cho, Sang Min;Choi, Youn Woong;Lee, Hye Jung;Kwon, Ji-Hye;Kim, Soo-Whan;Kim, Jae Woo;Lee, SeungHwan;Hong, Jang-Hee
    • Translational and Clinical Pharmacology
    • /
    • 제25권3호
    • /
    • pp.153-156
    • /
    • 2017
  • UI14SDF100CW is a chewable tablet of sildenafil citrate, which was developed to improve compliance through convenience of administration. The purpose of this study was to compare the pharmacokinetic (PK) properties of sildenafil citrate chewable tablets (UI14SDF100CW) and conventional sildenafil citrate film-coated tablets ($Viagra^{(R)}$, Pfizer). A randomized, open-label, single dose, two-treatment, two-period, two-way crossover study was conducted in 60 healthy male volunteers. In each period, the subjects received a single oral dose of UI14SDF100CW or $Viagra^{(R)}$ (both tablets contain 140.45 mg of sildenafil citrate, which is equivalent to 100 mg of sildenafil). Serial blood samples were collected up to 24 h post-dose for PK analysis. The plasma concentration of sildenafil was determined using a validated HPLC-MS/MS assay. PK parameters of sildenafil were calculated using non-compartmental methods. The plasma concentration-time profiles of sildenafil in both formulations were similar. For UI14SDF100CW, the $C_{max}$ and $AUC_{last}$ of sildenafil were $1068.69{\pm}458.25$ (mean${\pm}$standard deviation) mg/L and $3580.59{\pm}1680.29h{\cdot}mg/L$, and the corresponding values for $Viagra^{(R)}$ were $1146.84{\pm}501.70mg/L$ and $3406.35{\pm}1452.31h{\cdot}mg/L$, respectively. The geometric mean ratios (90% confidence intervals) of UI14SDF100CW to $Viagra^{(R)}$ for $C_{max}$ and $AUC_{last}$ were 0.933 (0.853-1.021) and 1.034 (0.969-1.108), respectively, which met the bioequivalence criteria of Korean regulatory agency. In conclusion, UI14SDF100CW and $Viagra^{(R)}$ showed similar PK properties. Therefore, UI14SDF100CW can be an alternative to sildenafil for the treatment of erectile dysfunction, providing better compliance.

PM10 질량농도 측정을 위한 시료채취기의 비교 연구 (A Comparison Study of Aerosol Samplers for PM10 Mass Concentration Measurement)

  • 박주면;구자건;정태영;권동명;유종익;서용칠
    • 대한환경공학회지
    • /
    • 제31권2호
    • /
    • pp.153-160
    • /
    • 2009
  • PM10(공기역학 직경${\leq}$10 ${\mu}m$) 시료채취기는 사람이 부유 먼지에 잠재적으로 노출되는 정도를 정량화하고 정부의 규제에 대응하기 위한 목적으로 사용된다. 본 연구는 동일한 PM10 분리한계 직경을 가지지만 다른 기울기를 가지는 미국 환경청의 PM10 시료채취 기준과 미국산업위생전문가협의회/유럽표준위원회/국제표준기구의 흉곽성 PM10 시료채취 기준을 이론과 실험을 통해 비교 평가하고자 수행되었다. 이를 위해 미국 환경청의 기준을 따르는 4개의 PM10 시료채취기와 흉곽성 PM10 기준과 일치하는 1개의 RespiCon 시료채취기를 비교 평가 수단으로 사용하였으며, 1개의 DustTrak 측정기를 PM10의 실시간 질량농도를 확인하기 위하여 사용하였다. 6개 시료채취기를 다양한 크기 분포를 가지는 비산재를 이용하여 입자 발생 챔버안에서 실험하였다. 이론적 질량농도는 측정된 비산재의 입자크기 분포 특성(기하평균 = 6.6 ${\mu}m$, 기하표준편차= 1.9)을 각 시료채취 기준에 적용하여 계산하였다. 챔버 실험을 통하여 측정된 질량농도 결과는 흉곽성 PM10 시료채취 기준을 가지는 RespiCon 시료채취기가 미국 환경청의 PM10 기준을 가지는 PM10 시료채취기보다 상대적으로 작은 질량농도를 측정함으로써 이론적 질량농도와 일치하였다. 전체적 챔버 실험 결과는 PM10 시료채취기를 기준 시료채취기로 사용하였을 때, (1) RespiCon 시료채취기는 PM10 시료채취기로 포집된 PM10 먼지 질량농도에 비해 평균 60% 정도 낮게 측정한 것을 의미하는 정규화계수 1.6으로 나타났으며 (2) PM10 유입구를 사용한 DustTrak 실시간 채취기는 2.1의 보정계수를 가지는 것으로 분석되었다.

자궁경부암 환자의 근접치료시 재현성 평가 (Reproducibility of Applicator Position with High dose rate brachytherapy in uterine cervical cancer)

  • 김종화;손정혜;정칠;김미화
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.29-33
    • /
    • 2003
  • I. 목적 외부방사선 치료와 같이 근접치료 시에도 재현성을 평가하기 위해 bone의 위치와 tandem, ovoid 간의 거리를 측정하여 치료 setting의 재현성을 평가함으로써 자궁경부암 환자의 근접치료시 치료의 재현성을 평가하고자 하였다. II. 대상 및 방법 1999년부터 2001년 10월까지 본원을 내원해서 근접치료를 시행한 자궁경부암 환자중 tandem, ovoid을 사용한 52명을 대상으로 근접치료시 촬영한 film(환자1명당 3회촬영)을 가지고 측정하였다. Os을 기준으로 환자의 center축을 잡고 tandem, ovoid의 위치와 pubic symphysis, sacrum, coccyx등과의 거리를 각각 측정하여 치료 setting의 재현성을 평가하였다. III. 결과 환자 52명에 대한 tandem, ovoid의 위치와 pubic symphysis, sacrum, coccyx등과의 거리에 대한 표준 편차 결과는 다음과 같은 분포로 나타났다. 1) 각 tandem angle 의 표준편차는 $0^{\circ}{\sim}2.89^{\circ}$이다. 2) pubic symphysis에서 Os까지의 높이는 $0cm{\sim}0.79cm$ 3) sacrum에서 tandem tip까지의 거리는 $0cm{\sim}0.9cm$ 4) Os level에서 coccyx까지의 거리는 $0.06cm{\sim}0.76cm$ 5) ovoid tip에서 Os까지의 거리는 오른쪽은 $0cm{\sim}0.53cm$ 6) ovoid tip에서 Os까지의 거리는 왼쪽은 $0cm{\sim}0.45cm$ 7) 첫번째 source위치에서 ovoid사이의 거리는 $0cm{\sim}0.36cm$ 8) tandem에서 ovoid tip까지의 거리는 $0cm{\sim}0.31cm$ IV. 결론 자궁경부암 치료에 있어 근접치료는 중요한 치료 방법이다. 환자 치료간에 재현성을 평가해본 결과 대체로 만족 할 만한 수치를 보였으며 고선량율 근접치료에서 재현성 평가는 중요할 것이고 계속적으로 평가할 필요가 있을 것이다.

  • PDF

정적 후처리방식에 의한 GPS의 측위정도 개선 (Improvement of GPS positioning accuracy by static post-processing method)

  • 김민선;신현옥
    • 수산해양기술연구
    • /
    • 제39권4호
    • /
    • pp.251-261
    • /
    • 2003
  • 기선장에 따른 GPS 위치 정도 및 분포를 측정하기 위하여 2002년 5월 29일부터 6월 2일까지 2대의 GPS수신기 (L1, 12채널)를 이용하여 고정점에서 30분에서 24시간동안 관측하는 실험을 수행하였다. 기준국(PKNU)과 이동, 국립지리원의 GPS 상시관측소에서 수신한 GPS 데이터는 동적 및 정적 후처리방식으로 처리하였으며, 그 결과를 요약하면 다음과 같다. 1. 2002년 5월 31일 차단각 (cut-off angle) $15^{\circ}$에서 6시간 이상 관측 가능한 위성은 16개였고, 위성은 주로 동서방향으로 배치되어 있었다. 10분마다 평균한위성 수와 GDOP는 각각 8개, 3.89이었다. 2. 후처리 전후의 GPS 평균위치는 모두 기준점에서 남서쪽으로 편위 (단독 측위 : 1.17m, 후처리 : 평균 0.43m)되었다. 확율원 오차는 단독 측위가 6.65m이었고 이를 동적 후처리하면 단독 측위의 약 33.8%(표준편차 0=17.2), 정적 후처리하면 단독 측위의 약 5.3% (0=2.2)로 감소시 킬 수 있었다. 3. 정적 후처리방식으로 구한 기선장 x(Km)와 확률원 오차 y(m) 의 관계식은 y = 0.0016x + 0006 $(R^2=0.87)$이었다. 본 연구에서 사용한 1주파용 GPS 수신기를 이용하여 정적 후처리방식으로 위치를 측정하는 경우, 기선장을 100Km 이내로 하고 GPS 수신시간을 30분 이상으로 하면 확율원 오차 20 Cm 이내의 측위가 가능함을 알 수 있었다.