• Title/Summary/Keyword: Geometric method

Search Result 3,010, Processing Time 0.032 seconds

Reproducibility of the Assessment of Myocardial Function Using Gated Tc-99m-MIBI SPECT and Quantitative Software (게이트 Tc-99m-MIBI SPECT와 Cedars 소프트웨어를 이용한 심근 기능 측정의 재현성)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Ahn, Ji-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.403-413
    • /
    • 1998
  • Purpose: We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. Materials and Methods: We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Results: Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/- 42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml +/- 39 ml), and EF from 20% to 65% (51% +/- 14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. Conclusion: We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m-MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect.

  • PDF

Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1) (유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1))

  • Park, Jung-Wook;Park, Eui-Seob;Kim, Taehyun;Lee, Changsoo;Lee, Jaewon
    • Tunnel and Underground Space
    • /
    • v.28 no.5
    • /
    • pp.400-425
    • /
    • 2018
  • This study presents the research results and current status of the DECOVALEX-2019 project Task B. Task B named 'Fault slip modelling' is aiming at developing a numerical method to simulate the coupled hydro-mechanical behavior of fault, including slip or reactivation, induced by water injection. The first research step of Task B is a benchmark simulation which is designed for the modelling teams to familiarize themselves with the problem and to set up their own codes to reproduce the hydro-mechanical coupling between the fault hydraulic transmissivity and the mechanically-induced displacement. We reproduced the coupled hydro-mechanical process of fault slip using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. A methodology to formulate the hydro-mechanical coupling relations of two different hydraulic aperture models and link the solid element of TOUGH2 and the interface element of FLAC3D was suggested. In addition, we developed a coupling module to update the changes in geometric features (mesh) and hydrological properties of fault caused by water injection at every calculation step for TOUGH-FLAC simulator. Then, the transient responses of the fault, including elastic deformation, reactivation, progressive evolutions of pathway, pressure distribution and water injection rate, to stepwise pressurization were examined during the simulations. The results of the simulations suggest that the developed model can provide a reasonable prediction of the hydro-mechanical behavior related to fault reactivation. The numerical model will be enhanced by continuing collaboration and interaction with other research teams of DECOLVAEX-2019 Task B and validated using the field data from fault activation experiments in a further study.

A Destructive Method in the Connection of the Algorithm and Design in the Digital media - Centered on the Rapid Prototyping Systems of Product Design - (디지털미디어 환경(環境)에서 디자인 특성(特性)에 관한 연구(硏究) - 실내제품(室內製品) 디자인을 중심으로 -)

  • Kim Seok-Hwa
    • Journal of Science of Art and Design
    • /
    • v.5
    • /
    • pp.87-129
    • /
    • 2003
  • The purpose of this thesis is to propose a new concept of design of the 21st century, on the basis of the study on the general signification of the structures and the signs of industrial product design, by examining the difference between modern and post-modern design, which is expected to lead the users to different design practice and interpretation of it. The starting point of this study is the different styles and patterns of 'Gestalt' in the post-modern design of the late 20th century from modern design - the factor of determination in industrial product design. That is to say, unlike functional and rational styles of modern product design, the late 20th century is based upon the pluralism characterized by complexity, synthetic and decorativeness. So far, most of the previous studies on design seem to have excluded visual aspects and usability, focused only on effective communication of design phenomena. These partial studies on design, blinded by phenomenal aspects, have resulted in failure to discover a principle of fundamental system. However, design varies according to the times; and the transformation of design is reflected in Design Pragnanz to constitute a new text of design. Therefore, it can be argued that Design Pragnanz serves as an essential factor under influence of the significance of text. In this thesis, therefore, I delve into analysis of the 20th century product design, in the light of Gestalt theory and Design Pragnanz, which have been functioning as the principle of the past design. For this study, I attempted to discover the fundamental elements in modern and post-modern designs, and to examine the formal structure of product design, the users' aesthetic preference and its semantics, from the integrative viewpoint. Also, with reference to history and theory of design my emphasis is more on fundamental visual phenomena than on structural analysis or process of visualization in product design, in order to examine the formal properties of modern and post-modern designs. Firstly, In Chapter 1, 'Issues and Background of the Study', I investigated the Gestalt theory and Design Pragnanz, on the premise of formal distinction between modern and post-modern designs. These theories are founded upon the discussion on visual perception of Gestalt in Germany in 1910's, in pursuit of the principle of perception centered around visual perception of human beings. In Chapter 2, I dealt with functionalism of modern design, as an advance preparation for the further study on the product design of the late 20th century. First of all, in Chapter 2-1, I examined the tendency of modern design focused on functionalism, which can be exemplified by the famous statement 'Form follows function'. Excluding all unessential elements in design - for example, decoration, this tendency has attained the position of the international style based on the spirit of Bauhause - universality and regularity - in search of geometric order, standardization and rationalization. In Chapter 2-2, I investigated the anthropological viewpoint that modern design started representing culture in a symbolic way including overall aspects of the society - politics, economics and ethics, and its criticism on functionalist design that aesthetic value is missing in exchange of excessive simplicity in style. Moreover, I examined the pluralist phenomena in post-modern design such as kitsch, eclecticism, reactionism, hi-tech and digital design, breaking away from functionalist purism of modern design. In Chapter 3, I analyzed Gestalt Pragnanz in design in a practical way, against the background of design trends. To begin with, I selected mass product design among those for the 20th century products as a target of analysis, highlighting representative styles in each category of the products. For this analysis, I adopted the theory of J. M Lehnhardt, who gradated in percentage the aesthetic and semantic levels of Pragnantz in design expression, and that of J. K. Grutter, who expressed it in a formula of M = O : C. I also employed eight units of dichotomies, according to the G. D. Birkhoff's aesthetic criteria, for the purpose of scientific classification of the degree of order and complexity in design; and I analyzed phenomenal aspects of design form represented in each unit. For Chapter 4, I executed a questionnaire about semiological phenomena of Design Pragnanz with 28 units of antonymous adjectives, based upon the research in the previous chapter. Then, I analyzed the process of signification of Design Pragnanz, founded on this research. Furthermore, the interpretation of the analysis served as an explanation to preference, through systematic analysis of Gestalt and Design Pragnanz in product design of the late 20th century. In Chapter 5, I determined the position of Design Pragnanz by integrating the analyses of Gestalt and Pragnanz in modern and post-modern designs In this process, 1 revealed the difference of each Design Pragnanz in formal respect, in order to suggest a vision of the future as a result, which will provide systemic and structural stimulation to current design.

  • PDF

Biological Study on the Increment of Survival Rate during Early Life Cycle in th Rockfish, Sebastes schlegeli (Telostei: Scorpaenidae) - I. Effects of Ammonia on Survival and Growth of the Larvae and Juveniles Stage (조피볼락, Sebastes schlegeli의 초기생활사 동안 생존율 향상을 위한 생물학적 연구 - I. 자어의 생존과 성장에 미치는 암모니아의 영향)

  • Chin, Pyung;Shin, Yun-Kyung;Kim, Hak-Gyoon;Lee, Jeong-Sick;Kim, Hyung-Soo
    • Korean Journal of Ichthyology
    • /
    • v.10 no.1
    • /
    • pp.98-105
    • /
    • 1998
  • The effect of ammonia on survival and growth of the larval rockfish, Sebastes schlegeli was examined by a static renewal bioassay method. The tolerance of larvae to ammonia toxicity was more sensitive at the early larvae, but increased with the development of larvae. In 14 day-old-larvae after parturition, the mortality with treatment of each concentration of ammonia was 5% at control group and 0.0112 $NH_3$mg/l, whereas it was increased up to 27.5% at exposure group of 0.1230 $NH_3$mg/l with higher concentration. Regression equation between ammonium concentration(X) and mortality(Y) was followed; Y=0.516+3.482 X($r^2=0.4737$, P<0.01). The NOEC(no-observable-effect concentration) and LOEC (lowest-observable-effect concentration) to mortality compared to control group were 0.100 $NH_3mg/l$ and 0.1230 $NH_3$mg/l, respectively and chronic value(ChV) which is the geometric mean of the NOEC and LOEC was 0.1110 $NH_3$mg/l. Body length after 7-days exposure in control group, 0.0112 $NH_3$mg/l and 0.1230 $NH_3$mg/l were 7.8325mm, 7.700mm and 7.05mm, respectively. The NOEC, LOEC and chronic value(ChV) were 0.0335 $NH_3$mg/l, 0.0558 $NH_3$mg/l and 0.0432 $NH_3$mg/l, respectively.

  • PDF

Comparison of Electrical Signal Properties about Top Electrode Size on Photoconductor Film (광도전체 필름 상부 전극크기에 따른 전기적 신호 특성 비교)

  • Kang, Sang-Sik;Jung, Bong-Jae;Noh, Si-Cheul;Cho, Chang-Hoon;Yoon, Ju-Sun;Jeon, Sung-Pyo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Currently, the development of direct conversion radiation detector using photoconductor materials is progressing in widely. Among of theses photoconductor materials, mercuric iodide compound than amorphous selenium has excellent absorption and sensitivity of high energy radiation. Also, the detection efficiency of signal generated in photoconductor film varies by electric filed and geometric distribution according to top-bottom electrode size. Therefore, in this work, the x-ray detection characteristics are investigated about the size of top electrode in $HgI_2$ photoconductor film. For sample fabrication, to solve the problem that is difficult to make a large area film, we used the spatial paste screen-print method. And the sample thickness is $150{\mu}m$ and an film area size is $3cm{\times}3cm$ on ITO-coated glass substrate. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a magnetron sputtering system and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$. From experimental measurement, the dark current, sensitivity and SNR of the $HgI_2$ film are obtained from I-V test. From the experimental results, it shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high dark current. Therefore, the optimized size of electrode is importance for the development of photoconductor based x-ray imaging detector.

The Phenomenological Comparison between Results from Single-hole and Cross-hole Hydraulic Test (균열암반 매질 내 단공 및 공간 간섭 시험에 대한 현상적 비교)

  • Kim, Tae-Hee;Kim, Kue-Young;Oh, Jun-Ho;Hwang, Se-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.39-53
    • /
    • 2007
  • Generally, fractured medium can be described with some key parameters, such as hydraulic conductivities or random field of hydraulic conductivities (continuum model), spatial and statistical distribution of permeable fractures (discrete fracture network model). Investigating the practical applicability of the well-known conceptual models for the description of groundwater flow in fractured media, various types of hydraulic tests were applied to studies on the highly fractured media in Geumsan, Korea. Results from single-hole packer test show that the horizontal hydraulic conductivities in the permeable media are between $7.67{\times}10^{-10}{\sim}3.16{\times}10^{-6}$ m/sec, with $7.70{\times}10^{-7}$ m/sec arithmetic mean and $2.16{\times}10^{-7}$ m/sec geometric mean. Total number of test interval is 110 at 8 holes. The number of completely impermeable interval is 9, and the low permeable interval - below $1.0{\times}10^{-8}$ m/sec is 14. In other words, most of test intervals are permeable. The vertical distribution of hydraulic conductivities shows apparently the good correlation with the results of flowmeter test. But the results from the cross-hole test show some different features. The results from the cross-hole test are highly related to the connectivity and/or the binary properties of fractured media; permeable and impermeable. From the viewpoint of the connection, the application of the general stochastic approach with a single continuum model may not be appropriate even in the moderately or highly permeable fractured medium. Then, further studies on the investigation method and the analysis procedures should be required for the reasonable and practical design of the conceptual model, with which the binary properties, including permeable/impermeable features, can be described.

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

Sediment Particulate Motions Over a Ripple Under Different Wave Amplitude Conditions (파랑에 의한 해저 사련 위에서의 유사입자의 거동 특성)

  • Chang, Yeon S.;Ahn, Kyungmo;Hwang, Jin H.;Park, Young-Gyu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.6
    • /
    • pp.374-385
    • /
    • 2013
  • Sediment particle motions have been numerically simulated over a sinusoidal ripple. Turbulent boundary layer flows are generated by Large Eddy Simulation, and the sediment particle motions are simulated using Lagrangian particle tracking method. Two unsteady flow conditions are used in the experiment by employing two different wave amplitudes while keeping other conditions such as wave period same. As expected, the amount of suspended sediment particles is clearly dependent on the wave amplitude as it is increasing with increasing flow intensity. However, it is also observed that the pattern of suspension may be different as well due to the only different condition caused by wave amplitude. Specially, the time of maximum sediment suspension within the wave period is not coincident between the two cases because sediment suspension is strongly affected by the existence of turbulent eddies that are formed at different times over the ripple between the two cases as well. The role of these turbulent eddies on sediment suspension is important as it is also confirmed in previous researches. However, it is also found the time of these eddies' formation may also dependent on the wave amplitude over rippled beds. Therefore, it has been proved that various flow as well as geometric conditions under waves has to be considered in order to have better understanding on the sediment suspension process over ripples. In addition, it is found that high turbulent energy and strong upward flow velocities occur during the time of eddy formation, which also supports high suspension rate at these time steps. The results indicate that the relationship between the structure of flows and bedforms has to be carefully examined in studying sediment suspension at coastal regions.

Effect of Package Size and Pasteurization Temperature on the Quality of Sous Vide Processed Spinach (Sous Vide 가공 시금치의 품질에 미치는 포장단위 및 살균온도의 영향)

  • 장재덕;김기태;이동선
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.195-200
    • /
    • 2004
  • Microbial lethal value and nutrient retention of sous vide processed spinach were evaluated with mathematical model prediction and experimental trial for different package sizes and pasteurization temperatures. The package size covers 500 g, 1 kg and 2 kg, while the pasteurization temperature includes 80, 90 and 97$^{\circ}C$. The basic process scheme consists of filling blanched spinach into barrier plastic film pouch, sealing under vacuum, pasteurization in hot water with over pressure and final cooling to 3$^{\circ}C$. Pasteurization condition was designed based on attainment of 6 decimal inactivation of Listeria monocytogenes at geometric center of the pouch package by heating cycle, which was determined by general method. Heat penetration property of the package and thermal destruction kinetics were combined to estimate the retention of ascorbic acid and chlorophyll. Smaller packages with shorter pasteurization time gave better nutrient retention, physical and chemical qualities. Larger package size was estimated and confirmed experimentally to give higher pasteurization value at center, lower ascorbic acid and chlorophyll contents caused by longer heat process time. Lower pasteurization temperature with longer process time was predicted to give lower pasteurization value at center and lower ascorbic acid, while chlorophyll content was affected little by the temperature. Experimental trial showed better retention of ascorbic acid and chlorophyll for smaller package and higher pasteurization temperature with shorter heating time. The beneficial effect of smaller package and higher pasteurization temperature was also observed in texture, color retention and drip production.

Development of Optimum Grip System in Developing Design Tensile Strength of GFRP Rebars (GFRP 보강근의 설계 인장강도 발현을 위한 적정 그립시스템 개발)

  • You Young-Chan;Park Ji-Sun;You Young-Jun;Park Young-Hwan;Kim Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.947-953
    • /
    • 2005
  • Previous test results showed that the current ASTM(American Standard for Testing and Materials) grip adapter for GFRP(Glass Fiber Reinforced Polymer) rebar was not fully successful in developing the design tensile strength of GFRP rebars with reasonable accuracy. It is because the current ASTM grip adapter which is composed of a pair of rectangular metal blocks of which inner faces are grooved along the longitudinal direction does not take into account the various geometric characteristics of GFRP rebar such as surface treatment, shape of bar cross section as well as physical characteristics such as poisson effect, elastic modulus in the transverse direction and so on. The objective of this paper is to provide how to proportion the optimum diameter of inner groove in ASTM grip adapter to develop design tensile strength of GFRP rebar. The proportioning of inner groove in ASTM grip adapter is based on the force equilibrium of GFRP rebar between tensile capacity and minimum frictional resistance required along the grip adapter. The frictional resistance of grip adapter is calculated based on the compressive strain compatibility in radial direction induced by the difference between diameter of GFRP rebar and inner groove In ASTM grip. All testing procedures were made according to the CSA S806-02 recommendations. From the preliminary test results on round-type GFRP rebars, it was found that maximum tensile loads acquired under the same testing conditions is highly affected by the diameter of inner groove in ASTM grip adapter. The grip adapter with specific dimension proportioned by proposed method recorded the highest tensile strength among them.