• 제목/요약/키워드: Geometric Information

Search Result 1,534, Processing Time 0.03 seconds

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.

Possibility Estimating of Unaccessible Area on 1/5,000 Digital Topographic Mapping Using PLEIADES Images (PLEIADES 영상을 활용한 비접근지역의 1/5,000 수치지형도 제작 가능성 평가)

  • Shin, Jin Kyu;Lee, Young Jin;Choi, Hae Jin;Lee, Jun Hyuk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.299-309
    • /
    • 2014
  • This paper evaluated the possibility for 1/5,000 digital topographic mapping by using PLEIADES images of 0.5m GSD(Ground Sampling Distance) resolution that has recently launched. Those results of check points by applying the initial RPC(Rational Polynomial Coefficient) of PLEIADES images came out as; RMSE of those were $X={\pm}1.806m$, $Y={\pm}2.132m$, $Z={\pm}1.973m$. Also, if we corrected geometric correction using 16 GCP(Ground Control Point)s, the results of RMSE became $X={\pm}0.104m$, $Y={\pm}0.171m$, $Z={\pm}0.036m$, and t he RMSE of check points were $X={\pm}0.357m$, $Y={\pm}0.239m$, $Z={\pm}0.188m$; which of those results indicated the accuracy of standard adjustment complied in error tolerances of the 1/5,000 scale. Additionally, we converted coordinates of points, obtained by TerraSAR. for comparing with measurements from GPS(Global Positioning System) surveying. The RMSE of comparing converted and GPS points were $X={\pm}0.818m$, $Y={\pm}0.200m$, $Z={\pm}0.265m$, which confirmed the possibility for 1/5,000 digital topographic mapping with PLEIADES images and GCPs. As method of obtaining GCPs in unaccessible area, however, the outcome evaluation of GCPs extracted from TerraSAR images was not acceptable for 1/5,000 digital topographic mapping. Therefore, we considered that further researches are needed on applicability of GCPs extracted from TerraSAR images for future alternative method.

Understanding of the Duplex Thrust System - Application to the Yeongwol Thrust System, Taebaeksan Zone, Okcheon Belt (듀플렉스트러스트시스템의이해 - 옥천대태백산지역영월트러스트시스템에의 적용)

  • Jang, Yirang
    • Economic and Environmental Geology
    • /
    • v.52 no.5
    • /
    • pp.395-407
    • /
    • 2019
  • The duplex system has been considered as an important slip-transfer mechanism to evaluate the evolution of orogenic belts. Duplexes are generally found in the hinterland portion of fold-thrust belts and accommodate large amounts of total shortening. Thus, understanding its geometric and kinematic evolution can give information to evaluate the evolution of the entire orogenic belt. Duplexes are recognized as closed-loop thrust traces on map view, indicating higher connectivity than imbricate fans. As originally defined, a duplex is an array of thrust horses which are surrounded by thrust faults including the floor and roof thrusts, and imbricate faults between them. Duplexes can accommodate regional layer-parallel shortening and transfer slip from a floor thrust to a roof thrust. However, an imbricate fault is not the only mean for layer-parallel shortening (LPS) and displacement transfer within duplexes. LPS cleavages and detachment folds can also play the same role. From this aspect, a duplex can be divided into three types; 1) fault duplex, 2) cleavage duplex and 3) fold duplex. Fault duplex can further be subdivided into the Boyer-type duplex, which was firstly designed duplex system in the 1980s that widely applied most of the major fold-thrust belts in the world, and connecting splay duplex, which has different time order in the emplacement of horses from those of the Boyer-type. On the contrary, the cleavage and fold duplexes are newly defined types based on some selected examples. In the Korean Peninsula, the Yeongwol area, the western part of the Taebaeksan Zone of the Okcheon Belt, gives an excellent natural laboratory to study the structural geometry and kinematics of the closed-loops by thrust fault traces in terms of a duplex system. In the previous study, the Yeongwol thrust system was interpreted by alternative duplex models; a Boyer-type hinterland-dipping duplex vs. a combination of major imbricate thrusts and their connecting splays. Although the high angled beds and thrusts as well as different stratigraphic packages within the horses of the Yeongwol duplex system may prefer the later complicate model, currently, we cannot choose one simple answer between the models because of the lack of direct field evidence and time information. Therefore, further researches on the structural field investigations and geochronological analyses in the Yeongwol and adjacent areas should be carried out to test the possibility of applying the fold and cleavage duplex models to the Yeongwol thrust system, and it will eventually provide clues to solve the enigma of formation and its evolution of the Okcheon Belt.

A Study on the Possibility of Producing a Floor Plan of 「Donggwoldo(東闕圖)」 through the Use of Rubber Sheeting Transformation - With a Focus on the Surroundings near the Geumcheongyo Bridge in Changdeokgung Palace - (러버쉬팅변환을 통한 「동궐도(東闕圖)」의 평면도 제작 가능성 연구 - 창덕궁 금천교 주변을 중심으로 -)

  • Lee, Jae-Yong;Kim, Young-Mo
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.4
    • /
    • pp.104-121
    • /
    • 2017
  • The present study attempted to produce the floor plan of the surroundings near Geumcheongyo Bridge in Changdeokgung Palace of the Late Joseon Period through the use of rubber sheeting transformation based on the drawing principles of "Donggwoldo(東闕圖)". First, the study compared the actual sizes of the major buildings that have existed since the production of "Donggwoldo(東闕圖)" with the sizes depicted in the picture to reveal that the front elevation of the buildings was produced by reducing it by approximately 1/200. However, the study could not confirm the same production proportions for the side elevation. Only the lengths of the side elevation were depicted at around half of the actual proportions, and as the diagonal line angles were found to be at an average of $39^{\circ}$, the study confirmed they were drawn in a manner similar to cabinet projection. Second, the study created an obliquely projected floor plan by inversely shadowing the drawing principles of "Donggwoldo(東闕圖)" and produced a floor plan of the surroundings near Geumcheongyo Bridge in Changdeokgung Palace through the use of rubber sheeting transformation. Projective transformation was confirmed as most suitable during the transformation, and with standard error of 2.1208m, the relatively high accuracy of the transformation shows that the production of a floor plan for "Donggwoldo(東闕圖)" is significant. Furthermore, it implies the possibility of producing floor plans for various documentary paintings produced using the paralleled oblique drawing method in addition to "Donggwoldo(東闕圖)". Third, the study evaluated the accuracy of the spatial information provided by the produced floor plan by comparing the three items of Geumcheongyo Bridge location, Geumcheongyo Bridge and Jinseonmun Gate arrangement, and Geumcheon stone embankment location. The results confirmed the possibility of utilizing the floor plan as a useful tool which helps understand the appearance of the surroundings at the time of "Donggwoldo(東闕圖)" production because it is parallel to the excavation results of the Geumcheongyo Bridge and its context. Therefore, the present study is significant in that it seeks the possibility of producing spatial information recorded in "Donggwoldo(東闕圖)" by applying rubber sheeting transformation and consequently in that it presents a new methodology for understanding the appearance of the East Palace of the Late Joseon Period.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

Study on the Chemical Management - 2. Comparison of Classification and Health Index of Chemicals Regulated by the Ministry of Environment and the Ministry of the Employment and Labor (화학물질 관리 연구-2. 환경부와 고용노동부의 관리 화학물질의 구분, 노출기준 및 독성 지표 등의 특성 비교)

  • Kim, Sunju;Yoon, Chungsik;Ham, Seunghon;Park, Jihoon;Kim, Songha;Kim, Yuna;Lee, Jieun;Lee, Sangah;Park, Donguk;Lee, Kwonseob;Ha, Kwonchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.58-71
    • /
    • 2015
  • Objectives: The aims of this study were to investigate the classification system of chemical substances in the Occupational Safety and Health Act(OSHA) and Chemical Substances Control Act(CSCA) and to compare several health indices (i.e., Time Weighted Average (TWA), Lethal Dose ($LD_{50}$), and Lethal Concentration ($LC_{50}$) of chemical substances by categories in each law. Methods: The chemicals regulated by each law were classified by the specific categories provided in the respective law; seven categories for OSHA (chemicals with OELs, chemicals prohibited from manufacturing, etc., chemicals requiring approval, chemicals kept below permissible limits, chemicals requiring workplace monitoring, chemicals requiring special management, and chemicals requiring special heath diagnosis) and five categories from the CSCA(poisonous substances, permitted substances, restricted substances, prohibited substances, and substances requiring preparation for accidents). Information on physicochemical properties, health indices including CMR characteristics, $LD_{50}$ and $LD_{50}$ were searched from the homepages of the Korean Occupational and Safety Agency and the National Institute of Environmental Research, etc. Statistical analysis was conducted for comparison between TWA and health index for each category. Results: The number of chemicals based on CAS numbers was different from the numbers of series of chemicals listed in each law because of repeat listings due to different names (e.g., glycol monoethylether vs. 2-ethoxy ethanol) and grouping of different chemicals under the same serial number(i.e., five different benzidine-related chemicals were categorized under one serial number(06-4-13) as prohibited substances under the CSCA). A total of 722 chemicals and 995 chemicals were listed at the OSHA and its sub-regulations and CSCA and its sub-regulations, respectively. Among these, 36.8% based on OSHA chemicals and 26.7% based on CSCA chemicals were regulated simultaneously through both laws. The correlation coefficients between TWA and $LC_{50}$ and between TWA and $LD_{50}$, were 0.641 and 0.506, respectively. The geometric mean values of TWA calculated by each category in both laws have no tendency according to category. The patterns of cumulative graph for TWA, $LD_{50}$, $LC_{50}$ were similar to the chemicals regulated by OHSA and CCSA, but their median values were lower for CCSA regulated chemicals than OSHA regulated chemicals. The GM of carcinogenic chemicals under the OSHA was significantly lower than non-CMR chemicals($2.21mg/m^3$ vs $5.69mg/m^3$, p=0.006), while there was no significant difference in CSCA chemicals($0.85mg/m^3$ vs $1.04mg/m^3$, p=0.448). $LC_{50}$ showed no significant difference between carcinogens, mutagens, reproductive toxic chemicals and non-CMR chemicals in both laws' regulated chemicals, while there was a difference between carcinogens and non-CMR chemicals in $LD_{50}$ of the CSCA. Conclusions: This study found that there was no specific tendency or significant difference in health indicessuch TWA, $LD_{50}$ and $LC_{50}$ in subcategories of chemicals as classified by the Ministry of Labor and Employment and the Ministry of Environment. Considering the background and the purpose of each law, collaboration for harmonization in chemical categorizing and regulation is necessary.

Serological Survey for the Major Viral Diseases in the Layers (국내 산란계의 주요 바이러스성 질병에 대한 혈청학적 모니터링 결과 및 분석)

  • Lee, Hae-Rim;Kim, Jong-Man;Kim, Jin-Hyung;Kim, Chang-Moon;So, Hyun-Hee;Lee, Dong-Woo;Ha, Bong-Do;Hong, Song-Chol;Mo, In-Pil
    • Korean Journal of Poultry Science
    • /
    • v.37 no.4
    • /
    • pp.361-372
    • /
    • 2010
  • Serological evaluation for the poultry is important for various reasons, such as designing and assessing the vaccination program and diagnosing diseases and for this reason, serologic tests for the layer flocks have been conducted on a regular basis. Moreover, the nationwide serological survey and analysis are essential to understand the epidemiological status of national poultry industry. In this sense, the study was conducted to evaluate the immune status of the layer flocks with the sera submitted to Avian Disease Laboratory, Chungbuk National University in 2009, and several important viral diseases were selected for evaluation including low pathogenic avian influenza (LPAI), Newcastle disease (ND), infectious bronchitis (IB) and avian metapneumovirus (aMPV). For LPAI and ND, the age-related patterns of geometric mean titer (GMT) changes were similar but there were differences in the flock positive rate and the level of GMT due to the different vaccination policy. In the case of IB, the values of GMT showed that the field infection was more prevalent than expected. For aMPV, positive birds in a flock increased as the layers got older, which reflected the course of field infection because vaccination against aMPV was not allowed in 2009. From this study, the immune status for the main viral diseases in layers became more clarified but this information was limited because of only one year study. Therefore, serological survey needs to be conducted on a yearly basis and furthermore include broilers and breeders for a better understanding of the health status in the national poultry industry.

Radiation Absorbed Dose Calculation Using Planar Images after Ho-166-CHICO Therapy (Ho-166-CHICO 치료 후 평면 영상을 이용한 방사선 흡수선량의 계산)

  • 조철우;박찬희;원재환;왕희정;김영미;박경배;이병기
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.155-162
    • /
    • 1998
  • Ho-l66 was produced by neutron reaction in a reactor at the Korea Atomic Energy Institute (Taejon, Korea). Ho-l66 emits a high energy beta particles with a maximum energy of 1.85 MeV and small proportion of gamma rays (80 keV). Therefore, the radiation absorbed dose estimation could be based on the in-vivo quantification of the activity in tumors from the gamma camera images. Approximately 1 mCi of Ho-l66 in solution was mixed into the flood phantom and planar scintigraphic images were acquired with and without patient interposed between the phantom and scintillation camera. Transmission factor over an area of interest was calculated from the ratio of counts in selected regions of the two images described above. A dual-head gamma camera(Multispect2, Siemens, Hoffman Estates, IL, USA) equipped with medium energy collimators was utilized for imaging(80 keV${\pm}$10%). Fifty-nine year old female patient with hepatoma was enrolled into the therapeutic protocol after the informed consent obtained. Thirty millicuries(110MBq) of Ho-166-CHICO was injected into the right hepatic arterial branch supplying hepatoma. When the injection was completed, anterior and posterior scintigraphic views of the chest and pelvic regions were obtained for 3 successive days. Regions of interest (ROIs) were drawn over the organs in both the anterior and posterior views. The activity in those ROIs was estimated from geometric mean, calibration factor and transmission factors. Absorbed dose was calculated using the Marinelli formula and Medical Internal Radiation Dose (MIRD) schema. Tumor dose of the patient treated with 1110 MBq(30 mCi) Ho-l66 was calculated to be 179.7 Gy. Dose distribution to normal liver, spleen, lung and bone was 9.1, 10.3, 3.9, 5.0 % of the tumor dose respectively. In conclusion, tumor dose and absorbed dose to surrounding structures were calculated by daily external imaging after the Ho-l66 therapy for hepatoma. In order to limit the thresholding dose to each surrounding organ, absorbed dose calculation provides useful information.

  • PDF

Application of Terrestrial LiDAR for Reconstructing 3D Images of Fault Trench Sites and Web-based Visualization Platform for Large Point Clouds (지상 라이다를 활용한 트렌치 단층 단면 3차원 영상 생성과 웹 기반 대용량 점군 자료 가시화 플랫폼 활용 사례)

  • Lee, Byung Woo;Kim, Seung-Sep
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.177-186
    • /
    • 2021
  • For disaster management and mitigation of earthquakes in Korea Peninsula, active fault investigation has been conducted for the past 5 years. In particular, investigation of sediment-covered active faults integrates geomorphological analysis on airborne LiDAR data, surface geological survey, and geophysical exploration, and unearths subsurface active faults by trench survey. However, the fault traces revealed by trench surveys are only available for investigation during a limited time and restored to the previous condition. Thus, the geological data describing the fault trench sites remain as the qualitative data in terms of research articles and reports. To extend the limitations due to temporal nature of geological studies, we utilized a terrestrial LiDAR to produce 3D point clouds for the fault trench sites and restored them in a digital space. The terrestrial LiDAR scanning was conducted at two trench sites located near the Yangsan Fault and acquired amplitude and reflectance from the surveyed area as well as color information by combining photogrammetry with the LiDAR system. The scanned data were merged to form the 3D point clouds having the average geometric error of 0.003 m, which exhibited the sufficient accuracy to restore the details of the surveyed trench sites. However, we found more post-processing on the scanned data would be necessary because the amplitudes and reflectances of the point clouds varied depending on the scan positions and the colors of the trench surfaces were captured differently depending on the light exposures available at the time. Such point clouds are pretty large in size and visualized through a limited set of softwares, which limits data sharing among researchers. As an alternative, we suggested Potree, an open-source web-based platform, to visualize the point clouds of the trench sites. In this study, as a result, we identified that terrestrial LiDAR data can be practical to increase reproducibility of geological field studies and easily accessible by researchers and students in Earth Sciences.

Characterization of Fault Kinematics based on Paleoseismic Data in the Malbang area in the Central Part of the Ulsan Fault Zone (고지진학적 자료를 이용한 울산단층대 중부 말방지역에서의 단층운동 특성 해석)

  • Park, Kiwoong;Prasanajit, Naik Sambit;Gwon, Ohsang;Shin, Hyeon-Cho;Kim, Young-Seog
    • Journal of the Korean earth science society
    • /
    • v.43 no.1
    • /
    • pp.151-164
    • /
    • 2022
  • According to the records of historical and instrumental earthquakes, the southeastern part of the Korean Peninsula is considered the highest seismic activity area. Owing to recent reports of numerous Quaternary faults along the Yangsan and Ulsan fault zones, paleoseismological studies are being actively conducted in these areas. The study area is located in the central part of the Ulsan fault zone, where the largest number of active faults have been reported. Based on lineament and geomorphic analysis using LiDAR images and aerial photographs, fault-related landforms showing topographic relief were observed and a trench survey was conducted. The trench length 20 m, width 5 m, depth 5 m is located approximately 300 m away to the northeast from the previously reported Malbang fault. From the trench section, we interpreted the geometric and kinematic characteristics of the fault based on the deformed features of the Quaternary sedimentary layers. The attitude of the reverse fault, N26°W/33°NE, is similar to those of the reported faults distributed along the Ulsan fault zone. Although a single apparent displacement of approximately 40 cm has been observed, the true displacement could not be calculated due to the absence of the slickenline on the fault plane. Based on the geochronological results of the cryogenic structure proposed in a previous study, the most recent faulting event has been estimated as being earlier than the late Wurm glaciation. We interpreted the thrust fault system of the study area as an imbrication structure based on the previous studies and the fault geometry obtained in this additional trench. Although several previous investigations including many trench surveys have been conducted, they found limited success in obtaining the information on fault parameters, which could be due to complex characteristics of the reverse fault system. Additional paleoseismic studies will contribute to solving the mentioned problems and the comprehensive fault evolution.