• Title/Summary/Keyword: Generator set

Search Result 388, Processing Time 0.026 seconds

Classification of Axis-symmetric Flaws with Non-Symmetric Cross-Sections using Simulated Eddy Current Testing Signals (모사 와전류 탐상신호를 이용한 비대칭 단면을 갖는 축대칭 결함의 형상분류)

  • Song, S.J.;Kim, C.H.;Shin, Y.K.;Lee, H.B.;Park, Y.W.;Yim, C.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.510-517
    • /
    • 2001
  • This paper describes an initial study for the application of eddy current pattern recognition approaches to more realistic flaw characterization in steam generator tubes. For this purpose, finite-element model-based theoretical eddy current testing (ECT) signals are simulated from 5 types of OD flaws with the variation in flaw size parameters and testing frequency. In addition, three kinds of software are developed for the convenience in the application of steps in pattern recognition approaches such as feature extraction feature selection and classification by probabilistic neural networks (PNNs). The cross point of the ECT signals simulated from flaws with non-symmetric cross-sections shows the deviation from the origin of the impedance plane. New features taking advantages of this phenomenon are added to complete the feature set with a total of 18 features. Then, classification with PNNs are performed based on this feature set. The PNN classifiers show high performance for the identification of symmetry in the cross-section of a flaw. However, they show very limited success in the interrogation of the sharpness of flaw tips.

  • PDF

Analysis of $CO_2$ and Harmful Gases Caused by Using Burn-type $CO_2$ Generators in Greenhouses (연소식 $CO_2$ 발생기 사용시 온실 내 $CO_2$ 및 유해가스 농도 분석)

  • Park, Jong-Seok;Shin, Jong-Wha;Ahn, Tae-In;Son, Jung-Eek
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.177-183
    • /
    • 2010
  • Bum-type $CO_2$ generators are widely used in greenhouses for the purpose of $CO_2$ supply for photosynthesis and greenhouse heating. However harmful gases included in the air might give severe effects on the plant growth. For investigating the possible emission of harmful gases from commercial bum-type $CO_2$ generators, we carried out the analysis of the harmful by-products (NO, NOx, $NO_2$, CO, and VOCs) and $CO_2$ caused by using a bum-type $CO_2$ generator in greenhouses. And the harmful by-products from different type of fuels such as kerosene, LPG, and LNG were quantified. In order to minimize the uncertainties from a $CO_2$ generator, 4 different $CO_2$ generators were utilized in four plastic greenhouses and a glasshouse located at different places during the experimental works. The results showed that the concentration of NOx is proportional to $CO_2$ concentration. Levels of harmful gases in the most of greenhouses, where the new bum-type $CO_2$ generators were installed, were lower than 1.0 ppm when $CO_2$ concentration was set at 1,000 ppm. In case of LNG combustion, the concentration of CO reached out up to 300 ppm and pre-treatment for CO reduction, such as the adsorption process, would be inevitable to abate the adverse effects on plant growth.

A Study on Water Level Control of PWR Steam Generator at Low Power Operation and Transient States (저출력 및 과도상태시 원전 증기발생기 수위제어에 관한 연구)

  • Na, Nan-Ju;Kwon, Kee-Choon;Bien, Zeungnam
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.3 no.2
    • /
    • pp.18-35
    • /
    • 1993
  • The water level control system of the steam generator in a pressurized water reactor and its control problems are analysed. In this work the stable control strategy during the low power operation and transient states is studied. To solve the problem, a fuzzy logic control method is applied as a basic algorithm of the controller. The control algorithm is based on the operator's knowledges and the experiences of manual operation for water level control at the compact nuclear simulator set up in Korea Atomic Energy Research Institute. From a viewpoint of the system realization, the control variables and rules are established considering simpler tuning and the input-output relation. The control strategy includes the dynamic tuning method and employs a substitutional information using the bypass valve opening instead of incorrectly measured signal at the low flow rate as the fuzzy variable of the flow rate during the pressure control mode of the steam generator. It also involves the switching algorithm between the control valves to suppress the perturbation of water level. The simulation results show that both of the fine control action at the small level error and the quick response at the large level error can be obtained and that the performance of the controller is improved.

  • PDF

Measurement of Rainfall using Sensor Signal Generated from Vehicle Rain Sensor (차량용 레인센서에서 생성된 센서시그널을 이용한 강우량 측정)

  • Kim, Young Gon;Lee, Suk Ho;Kim, Byung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.227-235
    • /
    • 2018
  • In this study, we developed a relational formula for observing high - resolution rainfall using vehicle rain sensor. The vehicle rain sensor consists of eight channels. Each channel generates a sensor signal by detecting the amount of rainfall on the windshield of the vehicle when rainfall occurs. The higher the rainfall, the lower the sensor signal is. Using these characteristics of the sensor signal generated by the rain sensor, we developed a relational expression. In order to generate specific rainfall, an artificial rainfall generator was constructed and the change of the sensor signal according to the variation of the rainfall amount in the artificial rainfall generator was analyzed. Among them, the optimal sensor channel which reflects various rainfall amounts through the sensitivity analysis was selected. The sensor signal was generated in 5 minutes using the selected channel and the representative values of the generated 5 - minute sensor signals were set as the average, 25th, 50th, and 75th quartiles. The calculated rainfall values were applied to the actual rainfall data using the constructed relational equation and the calculated rainfall amount was compared with the rainfall values observed at the rainfall station. Although the reliability of the relational expression was somewhat lower than that of the data of the verification result data, it was judged that the experimental data of the residual range was insufficient. The rainfall value was calculated by applying the developed relation to the actual rainfall, and compared with the rainfall value generated by the ground rainfall observation instrument observed at the same time to verify the reliability. As a result, the rain sensor showed a fine rainfall of less than 0.5 mm And the average observation error was 0.36mm.

TACAN modulation generator for antenna purpose that precisely adjusts factor of modulation (변조도를 정밀하게 조정 하는 TACAN 안테나용 변조신호발생기)

  • Kim, Jong-Won;Son, Kyong-Sik;Lim, Jae-Hyun
    • Journal of Digital Convergence
    • /
    • v.15 no.4
    • /
    • pp.275-284
    • /
    • 2017
  • TACAN(TACtical Air Navigation) was created to support military aircraft's short range navigation (200~300 mile). TACAN must fulfill a condition of MIL-STD-291C, the U.S. Military Standards, which addresses the sum of 15Hz and 135Hz should be within 55%, following the factor of modulations for both to be $21{\pm}9%$ each. Within the existing TACAN antenna, modulation factor for 15Hz and 135Hz are created differently depending on its diameter, wavelength, angle of gradient, internal modulation method or using frequency code. It brings up a problem where applications needed to be stopped and repaired when modulating signal exceeds the standard of MIL-STD-291C since the existing TACAN antenna does not have coordination function. Hence, plan and produce a modulating signal generator using FPGA, and check the changes in the modulation factor for 15HZ and 135Hz, depending on the values that have been set in each criteria. Moreover, allow the modulating signal generator to be automatically adjusted based on the monitoring signal emitted by antenna, and place alarm sound just in case if it exceeds the standard.

Effects of Gaseous Ozone Exposure on Bacterial Counts and Oxidative Properties in Chicken and Duck Breast Meat

  • Muhlisin, Muhlisin;Utama, Dicky Tri;Lee, Jae Ho;Choi, Ji Hye;Lee, Sung Ki
    • Food Science of Animal Resources
    • /
    • v.36 no.3
    • /
    • pp.405-411
    • /
    • 2016
  • The effects of gaseous ozone exposure on the bacterial counts and oxidative properties were evaluated in duck and chicken breast fillets, which were stored under a continuous flux of gaseous ozone (10×10−6 kg O3/m3/h) at 4±1℃ for 4 d. The ozone generator was set to on for 15 min and off for 105 min, and this cyclic timer was set during storage. Ozone effectively reduced the growth of coliform, aerobic and anaerobic bacteria in both chicken and duck breast. However, lipid oxidation occurred faster in duck breast than chicken breast with higher degree of discoloration, TBARS value, and antioxidant enzyme (glutathione peroxidase and catalase) activity decline rates. It is concluded that ozone effectively controlled the growth of bacteria in both chicken and duck breast with less effects on oxidative deterioration in chicken breast.

Characteristic of Vibration in Windturbine System (풍력발전시스템의 진동특성)

  • Kim, Jung-Su;Lee, Hyoung-Woo;Park, No-Gill;Kim, Young-Duk;Kim, Soo-Yum;Lee, Dong-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.786-795
    • /
    • 2011
  • This paper described the characteristic of vibration in wind turbine system including gearbox housing, gear drive, blade, generator. Especially, in planetary gear set, planet gears are supported by flexible pin. So, in planet gear, to consider not only torsional movement but also lateral movement. And include housing movement, because wind turbine system is supported by mount. To find out the characteristic of vibration, take the excitation source and study campbell diagram in operating range. Results of campbell diagram, resonances are occurred at 81.2HZ, 104.7Hz by 2nd tooth passing frequency. And resonance are also occurred at 264.5HZ, 377Hz, 424.6Hz by 3th tooth passing frequency. From the result, take vibration reduced measures.

A Study on Logic Built-In Self-Test Using Modified Pseudo-random Patterns (수정된 의사 무작위 패턴을 이용한 효율적인 로직 내장 자체 테스트에 관한 연구)

  • Lee Jeong-Min;Chang Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.8 s.350
    • /
    • pp.27-34
    • /
    • 2006
  • During Built-In Self-Test(BIST), The set of patterns generated by a pseudo-random pattern generator may not provide sufficiently high fault coverage and many patterns were undetected fault. In order to reduce the test time, we can remove useless patterns or change from them to useful patterns. In this paper, we reseed modify the pseudo-random and use an additional bit flag to improve test length and achieve high fault coverage. the fat that a random tset set contains useless patterns, so we present a technique, including both reseeding and bit modifying to remove useless patterns or change from them to useful patterns, and when the patterns change, we choose number of different less bit, leading to very short test length. the technique we present is applicable for single-stuck-at faults. the seeds we use are deterministic so 100% faults coverage can be achieve.

Dynamic Droop-based Inertial Control of a Wind Power Plant

  • Hwang, Min;Chun, Yeong-Han;Park, Jung-Wook;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1363-1369
    • /
    • 2015
  • The frequency of a power system should be maintained within the allowed limits for stable operation. When a disturbance such as generator tripping occurs in a power system, the frequency is recovered to the nominal value through the inertial, primary, and secondary responses of the operating synchronous generators (SGs). However, for a power system with high wind penetration, the system inertia will decrease significantly because wind generators (WGs) are operating decoupled from the power system. This paper proposes a dynamic droop-based inertial control for a WG. The proposed inertial control determines the dynamic droop depending on the rate of change of frequency (ROCOF). At the initial period of a disturbance, where the ROCOF is large, the droop is set to be small to release a large amount of the kinetic energy (KE) and thus the frequency nadir can be increased significantly. However, as times goes on, the ROCOF will decrease and thus the droop is set to be large to prevent over-deceleration of the rotor speed of a WG. The performance of the proposed inertial control was investigated in a model system, which includes a 200 MW wind power plant (WPP) and five SGs using an EMTP-RV simulator. The test results indicate that the proposed scheme improves the frequency nadir significantly by releasing a large amount of the KE during the initial period of a disturbance.

Activation of Multiple Transcriptional Regulators by Growth Restriction in Pseudomonas aeruginosa

  • Yeom, Doo Hwan;Im, Su-Jin;Kim, Soo-Kyoung;Lee, Joon-Hee
    • Molecules and Cells
    • /
    • v.37 no.6
    • /
    • pp.480-486
    • /
    • 2014
  • Growth restriction by antibiotics is a common feature that pathogenic bacteria must overcome for survival. The struggle of bacteria to escape from growth restriction eventually results in development of antibiotic-resistance through the expression of a set of genes. Here we found that some physiologically important transcriptional regulators of Pseudomonas aeruginosa including QscR, a quorum sensing (QS) receptor, SoxR, a superoxide sensor-regulator, and AntR, a regulator of anthranilate-related secondary metabolism, are activated by various growth-restricted conditions. We generated the growth-restricted conditions by various methods, such as overexpression of PA2537 and treatment with antibiotics or disinfectants. The overexpression of PA2537, encoding an acyltransferase homologue, tightly restricted the growth of P. aeruginosa and significantly activated QscR during the growth restriction. Similarly, treatments with gentamycin, tetracycline, and ethanol also activated QscR near their minimal inhibitory concentrations (MICs). Some non-QS regulators, such as AntR and SoxR, were also activated near the MICs in the same conditions. However, LasR and PqsR, other QS receptors of P. aeruginosa, were not activated, suggesting that only a specific set of transcriptional regulators is activated by growth restriction. Since paraquat, a superoxide generator, significantly activated QscR and AntR, we suggest that the oxidative stress generated by growth restriction may be partly involved in this phenomenon.