• Title/Summary/Keyword: Generator protection

Search Result 271, Processing Time 0.03 seconds

Commercial Grade Item Dedication of Digital Devices for Safety-related System in Nuclear Power Plant (원자력발전소 안전등급 계통 적용을 위한 디지털 상용기기 품질검증)

  • Hong, Young Hee;Bae, Byung Hwan;Park, Jaehyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1637-1639
    • /
    • 2014
  • In the past, the analog protection relays have been widely used for the safety-related systems in the nuclear power plants due to their stability and reliability. Meanwhile, as the high performance digital system has been developed, the digital systems have been adopted in the non-safety systems. However, since the digital systems currently used in the non-safety systems were not developed according to Q-class standard, Commercial Grade Item Dedication (CGID) procedure should be performed in order to apply them to the safety-related system. The purpose of this paper is to describe the CGID procedure including the analysis of the hardware architecture as well as the software embedded in protective relay to apply to the emergency diesel generator in the nuclear power plant. The entire CGID procedure was performed strictly according to the international standard and regulations.

A Framework for measuring query privacy in Location-based Service

  • Zhang, Xuejun;Gui, Xiaolin;Tian, Feng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.5
    • /
    • pp.1717-1732
    • /
    • 2015
  • The widespread use of location-based services (LBSs), which allows untrusted service provider to collect large number of user request records, leads to serious privacy concerns. In response to these issues, a number of LBS privacy protection mechanisms (LPPMs) have been recently proposed. However, the evaluation of these LPPMs usually disregards the background knowledge that the adversary may possess about users' contextual information, which runs the risk of wrongly evaluating users' query privacy. In this paper, we address these issues by proposing a generic formal quantification framework,which comprehensively contemplate the various elements that influence the query privacy of users and explicitly states the knowledge that an adversary might have in the context of query privacy. Moreover, a way to model the adversary's attack on query privacy is proposed, which allows us to show the insufficiency of the existing query privacy metrics, e.g., k-anonymity. Thus we propose two new metrics: entropy anonymity and mutual information anonymity. Lastly, we run a set of experiments on datasets generated by network based generator of moving objects proposed by Thomas Brinkhoff. The results show the effectiveness and efficient of our framework to measure the LPPM.

Performance Analysis of CHP Condersing Season heat load Conditions (계절별 부하 특성을 고려한 CHP 성능 해석)

  • Seo, Young-Ho;Lee, Joon-Hee;Kim, Nam-Jin;Kim, Jong-Yoon;Cho, Sung-Kap;Jeon, Yong-Han
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.454-459
    • /
    • 2010
  • This paper is a actual design case applied to make a bid for CHP plant construction in some country. The purpose of this study is to optimize the system performance for the requirement conditions written in ITB by the client. The system consists of gas turbine, steam turbine, heat recovery steam generator and heat exchangers for district heating. The performance analysis is conducted for various seasons conditions and heat load. As a result, air density and heat load is reduced in accordance with decreasing of the outdoor temperature, therefore the system power is reduced. Considering this, the design parameters to meet the requriement conditions are optimized.

A study of communication-based protection coordination for networked distribution system (네트워크 배전계통용 통신기반 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Lee, HakJu
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.43-48
    • /
    • 2022
  • Although the distribution system has been structured as complicated as a mesh in the past, the connection points for each line are always kept open, so that it is operated as a radial distribution system (RDS). For RDS, the line utilization rate is determined according to the maximum load on the line, and the utilization rate is usually kept low. In addition, when a fault occurs in the RDS, a power outage of about 3 to 5 minutes occurs until the fault section is separated, and the healthy section is transferred to another line. To improve the disadvantages of the RDS, research on the construction of a networked distribution system (NDS) that linking multiple lines is in progress. Compared to the RDS, the NDS has advantages such as increased facility utilization, load leveling, self-healing, increased capacity connected to distributed generator, and resolution of terminal voltage drop. However, when a fault occurs in the network distribution system, fault current can flow in from all connected lines, and the direction of fault current varies depending on the fault point, so a high-precision fault current direction determination method and high-speed communication are required. Therefore, in this paper, we propose an accurate fault current direction determination method by comparing the peak value polarity of the fault current in the event of a fault, and a communication-based protection coordination method using this method.

AN EXPERT SYSTEM FOR SETTING AND COORDINATION OF PROTECTIVE RELAYS (보호계전기의 정정 협조 전문가 시스템)

  • Lee, Seung-Jae;Kim, Ki-Hwa;Cho, Young-Ik;Yoon, Sang-Hyun;Yoon, Man-Chul;Lee, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.358-362
    • /
    • 1991
  • This paper describes enhancements made on PROSET, an, expert system which can perform setting and coordination of protective relays used in the ultra-high voltage transmission systems. Enhancements include the friendly and convenient environment for rulebase management and system manipulation, expanded setting capability, and faster processing speed which have been achieved through adoption of the new rule representation, rule order independent IE, rulebase editor, local database generator, Interface to PSS/E fault program, RB expansion etc.

  • PDF

Protection Coordination Study in Smart Grid with Diesel Generator (디젤발전기가 포함된 스마트그리드 보호계전 방안 연구)

  • Lee, Kang-Wan;Hong, Jong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.784-785
    • /
    • 2011
  • 보호계전시스템은 전력계통 운영 상태를 감시하여 전기 사고시 고장부분을 분리함으로써 전력공급 신뢰성 제고 및 고장파급 억제 기능을 수행한다. 스마트그리드는 신재생에너지원을 포함한 다양한 분산전원을 구비하고 있어, 전기 고장시 이들 분산전원으로부터 고장전류가 고장점으로 유입된다. 앞으로 보급 확산이 예상되는 소규모 스마트 그리드 구성 및 운전 형태별 고장전류를 해석하고 이를 이용하여 실현 가능한 스마트그리드 보호계전시스템의 구현 및 이의 동작 설정 값을 계산한다. 아울러 스마트그리드에 발생한 고장전류 크기 및 분포에 관련한 보호계전시스템의 적정성을 조사 및 분석한다.

  • PDF

Study on the Failure Case of Potential Transformer for Generator Protection Relay (발전기 보호계전기용 계기용변성기(PT) 손상 사례에 관한 연구)

  • Park, Jin-Yeub;Chin, Soo-Hwan;Park, In-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2065-2066
    • /
    • 2011
  • 기계적에너지를 전기적에너지로 변환하는 발전기를 내 외부 고장으로부터 보호하기 위해 보호계전기가 설치되어 있으며, 이러한 보호계전기의 동작신호 중 하나인 전압신호를 검출하기 위해 발전기와 변압기를 연결하는 모선에 설치된 계기용변성기를 이용한다. 본 논문은 발전기의 보호계전기용 계기용변성기 손상원인에 관한 연구로서, 계기용변성기의 철공진에 이한 손상가능성을 고찰하였고 발전소에 많이 사용되는 G사의 계기용변성기와 손상된 I사의 계기용변성기에 대한 전기적 시험결과를 비교하였으며, 계기용변성기를 직접 절개하여 제작 및 적용특성을 분석하였다. 그 결과 발전기 전압신호 검출용 계기용변성기는 발전기 중성점 접지형태에 관계없이 반드시 Line to Line type을 적용해야 함을 도출했다.

  • PDF

Pulsed Power Modulator based on IGBTs (IGBT 기반 고압 펄스전원장치)

  • Ryoo, H.J.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.43-46
    • /
    • 2007
  • In this paper, a novel new pulse power generator based on IGBT stacks is proposed for pulse power application. Proposed scheme consists of series connected 9 power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. The synchronization of gating signal is important for series operation of IGBTs. For gating signal synchronization, full bridge inverter and pulse transformer generates on-off signals of IGBT gating and specially designed gate power circuit was used. Proposed scheme has lots of advantages such as long lifecyle, compact size, flat topped pulse forming, small weight, protection for arc, high efficiency and flexibility to generate various kinds of pulse output.

  • PDF

Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.

Development of 60KV Pulsed Power Supply using IGBT Stacks (IGBT 직렬구동에 의한 60KV 펄스 전원장치 개발)

  • Ryoo, Hong-Je;Kim, Jong-Soo;Rim, Geun-Hie;Goussev, G.I.;Sytykh, D.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.88-99
    • /
    • 2007
  • In this paper, a novel new pulse power generator based on IGBT stacks is proposed for pulse power application. Because it can generate up to 60kV pulse output voltage without any step- up transformer or pulse forming network, it has advantages of fast rising time, easiness of pulse width variation and rectangular pulse shape. Proposed scheme consists of series connected 9 power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. To reduce component for gate power supply, a simple and robust gate drive circuit is proposed. For gating signal synchronization, full bridge invertor and pulse transformer generates on-off signals of IGBT gating with gate power simultaneously and it has very good characteristics of short circuit protection.