• Title/Summary/Keyword: Generator protection

Search Result 271, Processing Time 0.029 seconds

Determination of Consistency according to the Status of Supplementary Education for Radiation Safety Management Managers (방사선안전관리책임자 보수교육의 현황에 따른 정합성 판단)

  • Seung-Chul Kim
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.7-12
    • /
    • 2024
  • Medical institutions wishing to install and operate diagnostic radiation generators must complete appointment training within one year of appointment based on the 「Medical Act」 and the 「Rules on Safety Management of Diagnostic Radiation Generator Devices」 which will come into effect on January 1, 2024. Additionally, You must receive supplementary education every three years from the date you received it. The strengthening of safety management for diagnostic radiation generators used in medical institutions means that although the radiation exposure that may occur when using diagnostic radiation generators is low, the risk of carcinogenesis may be higher than previously evaluated. In addition, safety management of diagnostic radiation generators can be said to be an essential requirement because it has been reported that the incidence of leukemia and other diseases is increasing in diagnostic radiation tests. However, the safety management training targets and programs for radiation exposure management operated by other organizations other than diagnostic radiation generators are significantly different. In addition, since the public institutions that are responsible for radiation safety management are divided, there is a risk of duplicative, excessive, and under-administrative application to medical institutions and educational institutions that install and operate diagnostic radiation generators. Therefore, we would like to determine their consistency by comparing domestic and foreign related cases and the provisions of the 「Medical Act」 and the 「Nuclear Safety Act」.

Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers (증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가)

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 1999
  • Characteristics of radiation field in the steam generator(S/G) water chamber of a PWR were investigated and the anticipated effective dose rates to the worker in the S/G chamber were evaluated by Monte Carlo simulation. The results of crud analysis in the S/G of the Kori nuclear power plant unit 1 were adopted for the source term. The MCNP4A code was used with the MIRD type anthropomorphic sex-specific mathematical phantoms for the calculation of effective doses. The radiation field intensity is dominated by downward rays, from the U-tube region, having approximate cosine distribution with respect to the polar angle. The effective dose rates to adults of nominal body size and of small body size(The phantom for a 15 year-old person was applied for this purpose) appeared to be 36.22 and 37.06 $mSvh^{-1}$) respectively, which implies that the body size effect is negligible. Meanwhile, the equivalent dose rates at three representative positions corresponding to head, chest and lower abdomen of the phantom, calculated using the estimated exposure rates, the energy spectrum and the conversion coefficients given in ICRU47, were 118, 71 and 57 $mSvh^{-1}$, respectively. This implies that the deep dose equivalent or the effective dose obtained from the personal dosimeter reading would be the over-estimate the effective dose by about two times. This justifies, with possible under- or over- response of the dosimeters to radiation of slant incidence, necessity of very careful planning and interpretation for the dosimetry of workers exposed to a non-regular radiation field of high intensity.

  • PDF

Radiological Risk Assessment for $^{99m}Tc$ Generator using Uncertainty Analysis (불확실성 분석을 이용한 $^{99m}Tc$ 발생기 사용의 방사선위험도 평가)

  • Jang, H.K.;Kim, J.Y.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.129-139
    • /
    • 2004
  • Recently, much attentions are paid to the risk associated with increased uses of medium size radiation sources in medical and industrial fields. In this study, radiation risks to the worker and to the general public due to $^{99m}Tc$ generator were assessed for both normal and accident conditions. Based on the event tree technique, exposure scenarios for various situations were derived. Uncertainty analysis based on the Monte-Carlo technique was applied to the risk assessment for workers and members of the public in the vicinity of the work place. In addition, sensitivity analysis was performed on each of the five independent input parameters to identify importance of the parameters with respect to the resulting risk. Because the frequencies of normal tasks are fat higher than those of accidents, the total risk associated with normal tasks were higher than the accident risk. The annual dose due to normal tasks were $0.6mSv\;y^{-1}$ for workers and $0.014mSv\;y^{-1}$ for public, while in accident conditions $3.96mSv\;y^{-1}\;and\;0.0016mSv\;y^{-1}$, respectively. Uncertainty range of accident risk was higher by 10 times than that of normal risk. Sensitivity analysis revealed that source strength, working distance and working time were crucial factors affecting risk. This risk analysis methodology and its results will contribute to establishment of risk-informed regulation for medium and large radioactive sources.

Calculation of Shielding Rate of Radiation Protective Equipment Using the X-ray Spectrum of IPEM Report-78 (IPEM Report-78의 엑스선 스펙트럼을 이용한 방사선 방호장비의 차폐율 계산)

  • Han, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.755-760
    • /
    • 2021
  • In this study, the shielding rate of major X-ray protective equipment used in the medical environment was calculated using X-ray spectrum data emitted from the diagnostic X-ray generator of The Institute of Physics and Engineering(IPEM) Report-78, and the applicability of radiation protection was investigated. Radiation shielding rates were calculated through reduction rates of air-kerma and total intensity for lead apron (0.3 mmPb), thyroid shield (0.5 mmPb), lead goggles (0.5 mmPb), and lead glass (1.8, 2.7, 3.3 mmPb) used for diagnostic X-ray protection. As a result, the shielding rate calculated as the air kerma reduction rate ranged from 96.31 to 100% at 80 kV, and 90.35 to 100% at 120 kV. In addition, the results of this calculation were well matched with the results of previous studies measuring the actual shielding rate, and it is expected that the X-ray spectrum data of IPEM Report-78 can be used for radiation protection.

A study on appropriate ship power system for pulse load combine with secondary battery (펄스부하에 적합한 이차전지 연동형 선박 전력시스템에 관한 연구)

  • Oh, Jin-Seok;Lee, Hun-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.962-968
    • /
    • 2013
  • Problem of greenhouse gases associated with global warming and the world rise in fuel oil prices due to the depletion of fossil fuel has attracted attention. For this reason, maritime transport business, has shown interest in green-ship technology to reduce the consumption of fuel and reduce greenhouse gas for environmental protection. Power system of the ship is one of the most important factors for safe operation. Therefore, at design of ship power system, most of existing vessel used comparative large capacity generator in order to respond peak load such as bow thruster, crane and etc. In the navigation of ship, marine generators most would be operated at low load operation. In the low load operation of the generation rate of 50% or less, the operation efficiency of the generator it deteriorated, to consume more fuel oil. It also, it means that adversely effect the life of the generator. In this paper, studied how to apply for a secondary battery in container ship that relatively frequent arrival and departure in port. As a result, in order to apply the secondary battery to increase the operating efficiency of the generator during the voyage, it was confirmed that it is possible to reduce fuel consumption.

A Study on Setting SPS for Generator Tripping Action considering Operating Conditions of Power Systems (전력계통 운영조건을 고려한 발전기차단용 SPS 동작설정에 관한 연구)

  • Gwon, Han Na;Son, Hyeok Jin;Kook, Kyung Soo;Yang, Sung-Chae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.411-417
    • /
    • 2014
  • Special Protection Scheme(SPS) for generator tripping action is an emergency control tool that secures the power system stability by instantly tripping the pre-determined number of generators to avoid the acceleration of the remaining generators in a large-scaled power plants when a fault occurs on the drawing transmission lines. However, since the existing operating conditions of SPS are set based on a peak demand, SPS could trip more generators than required if it is activated during the off-peak demand period. For this, this paper proposes the algorithm for setting the operating conditions of SPS through the online stability evaluation with the periodically updated operating conditions of power systems. The proposed algorithm adopts COA for the accuracy and speed of the stability evaluation, and can reduce the number of tripping generators by SPS during the off-peak demand period. This results in reducing the loss of profit caused by a fault on power systems.

Performance Analysis of CHP(Combined Heat and Power) for Various Ambient Conditions (외기조건변화에 따른 CHP 성능 해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Kim, Nam-Jin;Lim, Kyung-Bum;Seo, Young-Ho;Kim, Ki-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3353-3359
    • /
    • 2011
  • The co-generation system consisted of gas a turbine, a steam turbine, heat recovery steam generator and a heat exchangers for district heating was investigated in the present study. A back-pressure steam turbine (non-condensing type) was used. A partial load analysis according to the outdoor temperature in winter was conducted and optimal thermal load and power conditions was examined using the commercial computing software Thermoflex. As a result, under a constant thermal load, the power outputs of gas turbine and overall system increased as an outdoor temperature decreased. On the other hand, the reduction in exhaust gas temperature led to the decrease in output of steam turbine. Considering the portion of gas turbine in overall system in terms of the power output, it can be known that the tendency in power output of overall system was similar to that of the gas turbine.

Failure Prediction of Metal Oxide Varistor Using Nonlinear Surge Look-up Table Based on Experimental Data

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.317-322
    • /
    • 2015
  • The metal oxide varistor (MOV) is a major component of the surge protection devices (SPDs) currently in use. The device is judged to be faulty when fatigue caused by the continuous inflow of lightning accumulates and reaches the damage limit. In many cases, induced lightning resulting from lightning strikes flows in to the device several times per second in succession. Therefore, the frequency or the rate at which the SPD is actually exposed to stress, called a surge, is outside the range of human perception. For this reason, the protective device should be replaced if it actually approaches the end of its life even though it is not faulty at present, currently no basis exists for making the judgment of remaining lifetime. Up to now, the life of an MOV has been predicted solely based on the number of inflow surges, irrespective of the magnitude of the surge current or the amount of energy that has flowed through the device. In this study, nonlinear data that shows the damage to an MOV depending on the count of surge and the amount of input current were collected through a high-voltage test. Then, a failure prediction algorithm was proposed by preparing a look-up table using the results of the test. The proposed method was experimentally verified using an impulse surge generator

Environmental Noise Prediction and Countermeasures for Packaged Power Station (육상용 디젤엔진 발전플랜트의 환경소음 영향 평가 및 저감 대책)

  • Song, Keun-Bok;Kim, Won-Hyun;Kim, Dong-Hae;Bae, Jong-Gug
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.6-11
    • /
    • 2007
  • Packaged power station (PPS) is a stationary diesel engine generator set and developed for the supply of electric power to small villages, islands and factories etc. Therefore, the PPS is closely installed to residence area and sometimes cause the environmental noise problems. In this paper, environmental noise analysis was performed for the power plant with 28 sets of PPS. The initial analysis results showed the some difference between the measurement and analysis because of the inaccurate noise source data. To improve the accuracy of analysis, main noise sources were inversely estimated using the in-situ measurement data in the vicinity of PPS and steam boiler. As the results of re-analysis, the good agreement was obtained and it was concluded that the noise levels exceed the specified noise limit in residence area. In order to reduce the noise, the several methods such as geometry alteration of inlet duct, application of hybrid-type silencer and noise protection barrier were suggested and verified with the confirmed analysis model.

  • PDF

Design on a Dual Impulse Surge Protector for the Power over Ethernet Devices (PoE(Power Over Ethernet)에서 임펄스성 서지보호 이중화 장치 설계)

  • Jin, Jong-Ho;Kim, Young-Jin;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.8
    • /
    • pp.927-934
    • /
    • 2015
  • In this paper, in order to prevent impulse surge PoE(Power Over Ethernet) communications error caused by natural phenomenon in industrial sites, countermeasure design of impulse surge of PoE communications equipment is suggested by designing dual impulse surge protection circuit. In order to analyze characteristic of impulse surge noise signal, surge generating device which meet international standard IEC 61000-4-5 is invented. And this device shows that surge signal is weakened by designing dual PoE power supply protection circuit by connecting surge generating device to the PoE data transfer line.