• Title/Summary/Keyword: Generator protection

Search Result 271, Processing Time 0.026 seconds

Comparative Analysis for the Frequency Estimation Algorithms (주파수 변화 추정 알고리즘 비교분석)

  • Kim, Chul-Hun;Kang, Sang-Hee;Nam, Soon-Ryul;Kim, Su-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1233-1234
    • /
    • 2006
  • Reliable frequency estimation is important for active power control, load shedding and generator protection. Thereby, frequency estimation is researched and some algorithms is proposed. This paper analyzed strength and weakness of each algorithms through comparative analysis of frequency estimation. Used algorithms are Zero Crossing detection, Discrete Fourier Transformation, Least Error Squares.

  • PDF

Comparative Analysis for the Frequency Estimation Algorithms (주파수 변화 추정 알고리즘 비교분석)

  • Kim, Chul-Hun;Kang, Sang-Hee;Nam, Soon-Ryul;Kim, Su-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1693-1694
    • /
    • 2006
  • Reliable frequency estimation is important for active power control, load shedding and generator protection. Thereby, frequency estimation is researched and some algorithms is proposed. This paper analyzed strength and weakness of each algorithms through comparative analysis of frequency estimation. Used algorithms are Zero Crossing detection, Discrete Fourier Transformation, Least Error Squares.

  • PDF

On UFR Settings Considering Wind Power Fluctuation In Jeju Island (제주도 풍력발전기 출력변동성을 고려한 적정 UFR 차단방식 연구)

  • Park, Min-Su;Chun, Yeong-Han;Byun, Sung-Hyun;Yang, Jeong-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.445-450
    • /
    • 2014
  • Jeju power system is connected to the mainland power system through HVDC, and receives about half of required electricity through the HVDC lines. Jeju power system already experienced black out when a generator tripped at the moment of the HVDC line faults. But, UFR operated as was expected when HVDC line fault occurred at that time. As the penetration level of wind turbines increases, it is required to set UFR again considering intermittent wind turbin outputs. In this paper, we address a new way of UFR setting through computer simulation.

The Design of UFR with Fast Frequency Measurement Technique (고속의 주파수 계측 알고리즘을 갖는 저주파 계전기 설계)

  • Park, Jong-Chan;Kim, Byung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • In this paper, the frequency estimator and DFT filter gain compensation for UFR(Under Frequency protection Relay) is introduced. Due to the sudden appearance of generator loads or faults in power system, the frequency is supposed to deviate from its nominal value. Because a frequency calculation is based on phase information, it needs sufficient sampling data to figure out a precious frequency. Therefore the frequency measurement for UFR needs excellent qualities such as high speed and precision with low sampling frequency Authors propose the frequency estimator which compares the vector differences and the DFT filter gain compensation which identifies DFT filter error and correct it. Using the frequency estimator and compensation, UFR which has the 0.01[ms] calculation delay and 0.003[Hz] measurement error is implemented with digital processor.

Design and Fabrication of Wide-band Transient Voltage Blocking Device (광대역 과도전압 차단장치의 설계 및 제작)

  • 송재용;이종혁;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.330-334
    • /
    • 1999
  • This paper presents a new transient voltage blocking device (TBD) for commucation facilities with low power and high frequency bandwidth. Conventional protection devices have some problems such as low frequency bandwidth, low energy capacity and high remnant voltage. In order to improve these limitations, the new TBD, which consists of a gas tube, avalanche diodes and junction type field effect transistors (JFETs), was designed and fabricated JFETs were used as an active non-linear element and a high speed switching diode with low capacitance limits high current. Therefore the avalanche diodes with low energy capacity are protected from the high current, and the TBD has a very small input capacitance. From the performance test using surge generator, which can produce 1.2/50${\mu}\textrm{s}$ 4.2 k$V_{max}$, 8/20${\mu}\textrm{s}$ 2.1 kA$\sub$max/, it is confirmed that the proposed TBD has an excellent protection performance in tight clamping voltage and limiting current characteristics.

  • PDF

The Study of Fast Frequency Measurement Technique for Protection Relay (계전기를 위한 고속의 주교수 계측 알고리즘)

  • Kim, Beung-Jin;Lee, Chang-Ho;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.211-213
    • /
    • 2005
  • In this paper, the frequency compensator for digital protective relay is introduced. Due to sudden appearance of generation-load or fault in power system, the frequency can deviate from its nominal value. The Orthogonal filter adopted to digital protective relay is exposed to the problem. Therefore, the frequency variation makes a difficult to protective function and power measurement in digital protective relay. The essential property of the proposed algorithm presented is its outstanding immunity to both signal orthogonal component magnitudes and DFT filter gain variations which ensures below 0.05Hz accuracy of estimation. Additionally, the proposed method has excellent characteristics with low signal sampling rate. Based on the frequency estimation, author design under frequency protection relay for generator and verifies its performance with several experimental tests.

  • PDF

Development of a Loss of Mains Detection Method for Distributed Resources (분산 전원의 고립 운전 검출 기법 개발)

  • Jang, S.I.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.42-45
    • /
    • 2001
  • The islanding protection for distributed resources (DR) becomes an important and emerging issue in power system protection since the distributed generator installations are rapidly increasing and most of the installed systems are interconnected with distribution network. In order to avoid the negative impacts on distributed network resulting from islanding operations of DR, it is necessary to detect the loss of mains (LOM) effectively. This paper presents a new LOM detection method using the rate of change in total harmonic distortion (THD) of current. The proposed method effectively detects LOM of the DR unit operating in parallel with the distribution network. We also verified the efficiency of the proposed method using the radial distribution network of IEEE 34 bus model.

  • PDF

Microwave Dielectric Absorption Spectroscopy Aiming at Novel Dosimetry Using DNAs

  • Izumi, Yoshinobu;Hirayama, Makoto;Matuo, Youichirou;Sunagawa, Takeyoshi
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.21-25
    • /
    • 2017
  • Background: We are developing L-band and S-band microwave dielectric absorption systems aiming novel dosimetry using DNAs, such as plasmid DNA and genomic DNA, and microwave technology. Materials and Methods: Each system is composed of a cavity resonator, analog signal generator, circulator, power meter, and oscilloscope. Since the cavity resonator is sensitive to temperature change, we have made great efforts to prevent the fluctuation of temperature. We have developed software for controlling and measurement. Results and Discussion: By using this system, we can measure the resonance frequency, f, and ${\Delta}Q$ (Q is a dimensionless parameter that describes how under-damped an oscillator or resonator is, and characterizes a resonator's bandwidth relative to its center frequency) within about 3 minutes with high accuracy. Conclusion: This system will be expected to be applicable to DNAs evaluations and to novel dosimetric system.

Considerations Review on Setting of Distance Relay using Technical Standards (기술기준에 의한 거리계전기 정정시 고려사항 검토)

  • Moon, Su-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1141-1145
    • /
    • 2018
  • Generally, in nuclear plants, distance relay (21R) has adapting to protect and to operate main protective of transmission lines and backup protective of main generator. Operation of 21R was required and based on exactly accurate calculation and criteria. But presently method of 21R setting has applied according to protection devices operation guide of KPX, excepting IEEE and ISA standards, which have a difference review directions, consider parameters and devices, also consideration factors were affected to relay operations by uncertain guides. therefore this paper proposed new protection relay setting method and unvague criteria from IEEE 741 and ANSI/ISA 67.04.01, and reviewed a different results through numerical calculation results for methods and criteria including previous and established 21r setting by IEEE, ANSI/ISA Technical standards.

Development of class I surge protection device for the protection of offshore wind turbines from direct lightning (해상풍력발전기 직격뢰 보호용 1등급 바리스터 개발)

  • Geon Hui Lee;Jae Hyun Park;Kyung Jin Jung;Sung-Man Kang;Seung-Kyu Choi;Jeong Min Woo
    • Journal of Wind Energy
    • /
    • v.14 no.4
    • /
    • pp.50-56
    • /
    • 2023
  • With the abnormal weather phenomena caused by global warming, the frequency and intensity of lightning strikes are increasing, and lightning accidents are becoming one of the biggest causes of failures and accidents in offshore wind turbines. In order to secure generator operation reliability, effective and practical measures are needed to reduce lightning damage. Because offshore wind turbines are tall structures installed at sea, the possibility of direct lightning strikes is very high compared to other structures, and the role of surge protection devices to minimize damage to the electrical and electronic circuits inside the wind turbine is very important. In this study, a varistor, which is a key element for a class 1 surge protection device for direct lightning protection, was developed. The current density was improved by changing the varistor composition, and the distance between the electrode located on the varistor surface and the edge of the varistor was optimized through a simulation program to improve the fabrication process. Considering the combined effects of heat distribution, electric field distribution, and current density on the optimized varistor surface, silver electrodes were formed with a gap of 0.5 mm. The varistor developed in this study was confirmed to have an energy tolerance of 10/350 ㎲, 50kA, which is a representative direct lightning current waveform, and good protection characteristics with a limiting voltage of 2 kV or less.