• Title/Summary/Keyword: Generator mode

Search Result 483, Processing Time 0.031 seconds

Power Control of a Hoist System Using Supercapacitor (수퍼캐패시터를 이용한 권상부하 시스템의 전력 제어)

  • Kim, Sang-Min;Yoo, Hyun-Jae;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.561-568
    • /
    • 2005
  • This paper proposes a method that distributes the load power and stores the regenerated energy for a hoist-load system using the supercapacitor, an energy storage device. The crane, which is a representative hoist-load system, operates in two modes. The first is the hoist-up mode in which the load container is lifted up: the maximum power is required at the end of acceleration. The second is the hoist-down mode in which the load container is lifted down; the regenerated energy is wasted by the resistor In this paper, the supercapacitor stores the regenerated energy in the hoist-down operation and supplies the peak power demand in the hoist-up operation. The same structure as the commercially available three-phase inverter is proposed as a bidirectional do-dc converter to charge and discharge the supercapacitor. A power control algorithm is proposed to optimize the load sharing between the generator and the supercapacitor. Using the proposed method, it is effected that the generator size can be cut down to one third of the original one; it leads to the reduction of the fuel consumption, noise and air pollution. Simulation and experimental results verify the effectiveness of the Proposed method.

AN EVALUATION OF THE APERIODIC AND FLUCTUATING INSTABILITIES FOR THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN INTEGRAL REACTOR

  • Kang Han-Ok;Lee Yong-Ho;Yoon Ju-Hyeon
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.343-352
    • /
    • 2006
  • Convenient analytical tools for evaluation of the aperiodic and the fluctuating instabilities of the passive residual heat removal system (PRHRS) of an integral reactor are developed and results are discussed from the viewpoint of the system design. First, a static model for the aperiodic instability using the system hydraulic loss relation and the downcomer feedwater heating equations is developed. The calculated hydraulic relation between the pressure drop and the feedwater flow rate shows that several static states can exist with various numbers of water-mode feedwater module pipes. It is shown that the most probable state can exist by basic physical reasoning, that there is no flow rate through the steam-mode feedwater module pipes. Second, a dynamic model for the fluctuating instability due to steam generation retardation in the steam generator and the dynamic interaction of two compressible volumes, that is, the steam volume of the main steam pipe lines and the gas volume of the compensating tank is formulated and the D-decomposition method is applied after linearization of the governing equations. The results show that the PRHRS becomes stabilized with a smaller volume compensating tank, a larger volume steam space and higher hydraulic resistance of the path $a_{ct}$. Increasing the operating steam pressure has a stabilizing effect. The analytical model and the results obtained from this study will be utilized for PRHRS performance improvement.

Simulation of Water/steam into Sodium Leak Behavior for an Acoustic Noise Generation Mechanism Study

  • Kim, Tae-Joon;Hwang, Sung-Tai;Jeong, Kyung-Chai;Park, Jong-Hyeun;Valery S. Yughay
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.145-155
    • /
    • 2001
  • This simulation first allows us to define a transition zone from a bubble to jet mode of the argon out-flow and hereinafter to define a similar area for water-steam leak in the KALIMER SG (Korea Advanced Liquid Metal Reactor Steam Generator) using a water mock-up system, taking into account the KALIMER leak classification and tube bundle design, as a simulation of a real water-steam into sodium leak. in accordance with leak conditions in the KALIMER SG, the transition from bubbling to jetting is studied by means of turbulence regime simulation for argon out-flow through a very small orifice, which has the equivalent diameter of about 0.253 mm. finally the noise generation mechanism is explained from the existing experimental data. We also confirmed the possibility of micro-leak detection from the information of the bubbling mode through simulations and the experiment in this study.

  • PDF

Development of Efficient Operational Mode for Wind-Diesel Hybrid System

  • Asghar, Furqan;Kim, Se-Yoon;Kim, Sung Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.5
    • /
    • pp.554-561
    • /
    • 2014
  • Hybrid wind Diesel stand-alone power systems are considered economically viable and effective to create balance between production and load demand in remote areas where the wind speed is considerable for electric generation, and also, electric energy is not easily available from the grid. In Wind diesel hybrid system, the wind energy system is the main constitute and diesel system forms the back up. This type of hybrid power system saves fuel cost, improves power capacity to meet the increasing demand and maintains the continuity of supply in the system. Problem we face in this system is that even after producing enough power through wind turbine system, considerable portion of this power needs to be dumped due to short term oversupply of power and to maintain the frequency within close tolerances. As a result remaining portion of total energy supplied comes from the diesel generator to overcome the temporal energy shortage. This scenario decreases the overall efficiency of hybrid power system. In this study, efficient Simulink modeling for wind-diesel hybrid system is proposed and some simulations study is carried out to verify the feasibility of the proposed scheme.

A New Start-up Method for a Load Commutated Inverter for Large Synchronous Generator of Gas-Turbine

  • An, Hyunsung;Cha, Hanju
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.201-210
    • /
    • 2018
  • This paper proposes a new start-up method for a load commutated inverter (LCI) in a large synchronous gas-turbine generator. The initial rotor position for start-up torque is detected by the proposed initial angle detector, which consists of an integrator and a phase-locked loop. The initial rotor position is accurately detected within 150ms, and the angle difference between the real position and the detected position is less than 1%. The LCI system operates in two modes (forced commutation mode and natural commutation mode) according to operating speed range. The proposed controllers include a forced commutation controller for the low-speed range, a PI speed controller and a PI current controller, where the forced commutation controller is connected to the current controller in parallel. The current controller is modeled by Matlab/Simulink, where a six-pulse delay of the thyristor and a processing delay are considered by using a zero-order hold. The performance of the proposed start-up method is evaluated in Matlab/Psim at standstill and at low speed. To verify the feasibility of the method, a 5kVA LCI system prototype is implemented, and the proposed initial angle detector and the system performance are confirmed by experimental results from standstill to 900rpm.

Dynamic model and simulation of microturbine generation system for grid-connected operation (마이크로터빈발전시스템 계통연계운전을 위한 동적 모델링 및 시뮬레이션)

  • Hong, Won-Pyo;Cho, Jea-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.105-110
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for grid-connected operation. The system comprises of a permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of Power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in grid-connected operation mode of a DG system. The control strategies for grid connected operation mode of DG system is also presented.

  • PDF

Dynamic Model of Microturbine Generation System for Stand-Alone Mode Operation (마이크로터빈발전시스템 독립운전을 위한 동적 모델링)

  • Cho, Jea-Hoon;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.210-216
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market. In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for stand-alone operation. The system comprises of a permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in stand-alone operation mode of a DG system.

Design and Analysis of Universal Power Converter for Hybrid Solar and Thermoelectric Generators

  • Sathiyanathan, M.;Jaganathan, S.;Josephine, R.L.
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.220-233
    • /
    • 2019
  • This work aims to study and analyze the various operating modes of universal power converter which is powered by solar and thermoelectric generators. The proposed converter is operated in a DC-DC (buck or boost mode) and DC-AC (single phase) inverter with high efficiency. DC power sources, such as solar photovoltaic (SPV) panels, thermoelectric generators (TEGs), and Li-ion battery, are selected as input to the proposed converter according to the nominal output voltage available/generated by these sources. The mode of selection and output power regulation are achieved via control of the metal-oxide semiconductor field-effect transistor (MOSFET) switches in the converter through the modified stepped perturb and observe (MSPO) algorithm. The MSPO duty cycle control algorithm effectively converts the unregulated DC power from the SPV/TEG into regulated DC for storing energy in a Li-ion battery or directly driving a DC load. In this work, the proposed power sources and converter are mathematically modelled using the Scilab-Xcos Simulink tool. The hardware prototype is designed for 200 W rating with a dsPIC30F4011 digital controller. The various output parameters, such as voltage ripple, current ripple, switching losses, and converter efficiency, are analyzed, and the proposed converter with a control circuit operates the converter closely at 97% efficiency.

Behavior Analysis of a Self Excited Induction Generator with Various Loads for a Hybrid Electric Propulsion System (하이브리드 전기추진시스템 구축을 위한 SEIG의 출력 특성 분석)

  • Yang, Joo-Ho;Choi, Gyo-Ho;Lee, Jae-Min;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.22 no.1
    • /
    • pp.41-47
    • /
    • 2018
  • This paper analyzes the output characteristics of a self excited induction generator with isolated mode according to change of its speeds and loads for building a hybrid electric propulsion system in special purpose ships by using power take off. The induction generators are being considered as an alternative choice to the well-developed generators because of their lower unit cost, inherent ruggedness, operational and maintenance simplicity. However, the generator working by stand alone has a few problems that the reactive power is required to establish the air gap magnetic flux, and the induced voltage and magnetizing current fluctuate when the load is varied. In spite of its advantages, basic design data of the capacitor bank and behaviors of the output characteristics of the generator are not sufficient for the system. Based on the operating condition(speed range of main engine) of the target boat, a reduced experimental equipment system was constructed to analyze the output characteristics of the SEIG. And a suitable capacitor bank of a stand-alone generator and its output characteristics under various loads was investigated in detail through these experiments. According to the experimental result, it was confirmed that the capacitor bank should be $70{\mu}F{\sim}100{\mu}F$, and the proper SEIG induced voltage should be DC 80 V ~ 250 V in order to storage electrical energy into a battery.

A Thermoelectric Energy Harvesting Circuit For a Wearable Application

  • Pham, Khoa Van;Truong, Son Ngoc;Yang, Wonsun;Min, Kyeong-Sik
    • Journal of IKEEE
    • /
    • v.21 no.1
    • /
    • pp.66-69
    • /
    • 2017
  • In recent year, energy harvesting technologies from the ambient environments such as light, motion, wireless waves, and temperature again a lot of attraction form research community [1-5] due to its efficient solution in order to substitute for conventional power delivery methods, especially in wearable together with on-body applications. The drawbacks of battery-powered characteristic used in commodity applications lead to self-powered, long-lifetime circuit design. Thermoelectric generator, a solid-state sensor, is useful compared to the harvesting devices in order to enable self-sustained low-power applications. TEG based on the Seebeck effect is utilized to transfer thermal energy which is available with a temperature gradient into useful electrical energy. Depending on the temperature difference between two sides, amount of output power will be proportionally delivered. In this work, we illustrated a low-input voltage energy harvesting circuit applied discontinuous conduction mode (DCM) method for getting an adequate amount of energy from thermoelectric generator (TEG) for a specific wearable application. With a small temperature gradient harvested from human skin, the input voltage from the transducer is as low as 60mV, the proposed circuit, fabricated in a $0.6{\mu}m$ CMOS process, is capable of generating a regulated output voltage of 4.2V with an output power reaching to $40{\mu}W$. The proposed circuit is useful for powering energy to battery-less systems, such as wearable application devices.