• 제목/요약/키워드: Generator Stator Windings

검색결과 106건 처리시간 0.03초

Comparative Analysis of 10 MW Superconducting Wind Power Generators with Three-phase and Nine-phase Armature Windings

  • Kim, Taewon;Woo, Sang-Kyun;Sung, Hae-Jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.343-347
    • /
    • 2019
  • When referring to weight, volume, and efficiency, a SuperConducting Synchronous Generator (SCSG) is definitely superior to conventional generators as a large-scale wind power generation system. The SCSG is connected to a full power converter that transmits the energy from the SCSG to the power grid. To reduce the current stress and system cost, the SCSG which has nine-phase armature windings with three converters is used. This paper deals with a comparative analysis of 10 MW superconducting wind power generators with three-phase and nine-phase armature windings. The stator windings of SCSGs are of various types. Using the finite element method, SCSGs are analyzed and compared in terms of the weight and volume of SCSGs, the total length of the superconducting wire, harmonics, torque performance, and efficiency. The analyzed results will be effectively utilized to design large-scale superconducting generators for wind power generation systems.

2중 공극형 횡자속 영구자석 동기발전기 설계 및 특성분석 (Design and Characteristics Analysis of Dual Air-Gap Axial-Flux type Permanent-Magnet Synchronous Generator)

  • 배성우;황돈하;강도현;김용주;최경호;김동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1063-1066
    • /
    • 2003
  • This paper presents the design and characteristics analysis of axial-flux permanent-magnet (PM) synchronous generator of two air-gap. Dual axial-flux type PM synchronous generator commonly appears in applications where the generator axial dimension is more limited than the radial dimension. The strengths of dual axial-flux generator include ; (1) by employing two air-gaps, the rotor-stator attractive forces are balanced and no net axial or thrust load appeals on the generator hearings ; (2) heat produced by the stator windings appears on the outside of the generator, making it relatively easy to remove, and so on. In this paper, the simple magnetic equivalent circuit approach is used for initial design iteration, and the finite-element method is applied to analyze the detailed characteristics. The test results of driving characteristics are presented as well. The results are very similar to predicted performance of design.

  • PDF

교류발전기 보호를 위한 고장검출 알고리즘의 비교 분석 (A Comparative Analysis of fault Detection Algorithm for AC Generator Protection)

  • 박철원;신광철;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.75-77
    • /
    • 2007
  • Current percentage differential relaying has been recognized as the principal basis of main protection for stator windings of AC generator. The DWT has merit of obtaining frequency characteristics in time domain. In order to compensate for DFT's defects, we proposed fault detection algorithm using DWT. This paper describes a comparative analysis about conventional DFT-based DFR and advanced DWT-based relaying.

  • PDF

스위치드 릴럭턴스 발전기의 스위칭에 따른 특성 (Characteristics Analysis According to Switching of Switched Reluctance Generator)

  • 오재석;오주환;권병일
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1356-1361
    • /
    • 2008
  • A switched reluctance generator(SRG) has simple magnetic structure, and needs simple power electronic driving circuit. But, a SRG are no windings or permanent magnets on the rotor, and there are concentrated windings placed around each salient pole on the stator. Because of the characteristics of time-sharing excitation, the control of SRG is very flexible. And there are several parameters for controlling SRG, such as switch turn-on angle, switch turn-off angle, and exciting voltage and controlling mode, all these will affect the generation greatly. A SRG has positive torque at increasing inductance region and negative torque at decreasing inductance region. In this paper, we studied characteristics about the switch turn-on and off angles according to switch method for constant output voltage of the fixed speed SRG. It is the acoustic noise and torque ripple characteristics. Characteristics for a switch angle and method are presented by experiment using a 50W SRG with 12/8 poles.

IGBT 인버터 구동 유도전동기 고정자 권선에서의 과도전압 분포 해석 (Analysis of Overvoltage Distribution in Stator Winding of Induction Motor Driven by IGBT PWM Inverter)

  • 배성우;황돈하;김용주;김동희;김민회;이인우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.17-20
    • /
    • 2002
  • In this paper voltage distribution in stator windings of induction motor driven by IGBT PWM inverter is studied. To analyze the irregular voltage of stator winding, equivalent circuit model of inverter-cable-motor was proposed and high frequency parameter is computed by using finite element method (FEM). Electro-magnetic transient program (EMTP) analysis of the whole system for induction motor and PWM inverter is proposed. Induction motor, 50[HP], and a switching surge generator was built to consider the voltage distribution. The results of EMTP analysis compared with experimental results.

  • PDF

Behaviour Analysis of Self Excited Induction Generator Feeding Linear and No Linear Loads

  • Moulahoum, Samir;Kabache, Nadir
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1371-1379
    • /
    • 2013
  • Application of induction machines in wind turbine driven generators is a good alternative due to their good characteristics such as efficiency, reliability and low cost. Nevertheless, when isolated operation is required, the application of external capacitive bank, connected to the stator windings, to provide self-excitation results in a rather complex analysis. This paper presents an analysis of self-excited induction generator connected to a load either directly or by an intermediate of a power converter. At first a dynamic model of the induction generator accounting for magnetic saturation is developed. Then a number of balanced and unbalanced capacitors, passive and active loads are verified. Experimental results obtained from laboratory tests are compared to those simulated; the two are shown to be in good agreement.

고압회전기 고정자 권선의 부분방전 측정 (Partial Discharge Measurements of High Voltage Rotating Machine Stator Windings)

  • 김희동;이영준;공태식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1828-1830
    • /
    • 2003
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in two 4.16kV and three 6.6kV motors. These tests were conducted using a conventional partial discharge detector(PDD) and turbine generator analyzer(TGA). Off-line PD measurements were performed on five high voltage motors. PD magnitudes ranged from 1000 pC to 5400 pC at the normal line-to-ground voltage. Five high voltage motors have been equipped with 80pF epoxy-mica coupler on the motor terminal box. The PD pulse from sensors were measured with the TGA instrument. TGA summarizes each plot with two Quantities such as the peak PD magnitude(Qm) and the total PD activity(NQN). The defect mechanisms of high voltage motor can be associated with PD patterns such as internal, slot and conductor surface discharges. The PDD and TGA test results of No. 4 motor showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

발전기 고정자 단말권선 모델링 및 진동 특성 분석 (Modeling/Vibration Analysis of Generator Stator End Windings)

  • 배용채;이현;홍승모
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1805-1809
    • /
    • 2000
  • 발전기 운전중 발생되는 전자력은 고정자 권선 특히 단말권선와 진동을 유발시켜 피로 균열을 발생시킬 수 있으며 이로 인한 권선 누수 사고 및 발전기 수명 저하를 초래할 수 있다. 본 논문에서는 500MW급 발전기 고정자 단말 권선을 모델링하여 이를 운전중인 발전기 고정자 권선 단말부의 진동 특성과 비교하였다.

  • PDF

동기 발전기의 평형 및 불평형 고장해석 (Balanced and Unbalanced Fault Analysis of Synchronous Generator)

  • 박철원;안준영;이종수;이상성;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.402-404
    • /
    • 2006
  • In this paper, we simulated transient-state under fault in stator windings of synchronous generator. The fault types are line to ground fault, line to line short fault, and three phase short fault. For fault analysis of generator system, the voltage equation of a synchronous machine using the two-axis theory was used. It can be used to analyze important features of faults and to develop enhanced protection methods.

  • PDF