• 제목/요약/키워드: Generator Sensitivity

검색결과 167건 처리시간 0.028초

원자력 발전소 터빈-발전기 고진동 저감에 대한 고찰 (Analysis of High Vibration in Nuclear Turbine-Generator)

  • 이우광;고우식;김계연;구재량
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.46-50
    • /
    • 2007
  • The nuclear power plant's turbine-generator system had been suffered form some problems, such as high shaft vibration, generator casing crack, stator coil water leakage, high $H_2$ gas consumption rate. Those kinds of problems were related to high vibration. So nuclear plant decided to replace generator in order to reduce rotor high vibration and high thermal sensitivity. A series of effort to reduce turbine-generator vibration was carried out as followings, first of all, replacement of generator, analysis of turbine-generator vibration, LP B rotor shop balancing, improvement of LP B/Gen coupling run-out, improvement of Generator basement and field balancing. Finally the nuclear turbine-generator's shaft vibration was reduced below $60{\mu}m$ from over $200{\mu}m$ which is very excellent vibration in nuclear turbine-generator in Korea.

  • PDF

발전기 이산 민감도를 이용한 효율적인 우선순위법의 대규모 예방정비계획 문제에의 적용 연구 (An Effective Priority Method Using Generator's Discrete Sensitivity Value for Large-scale Preventive Maintenance Scheduling)

  • 박종배;정만호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.234-240
    • /
    • 1999
  • This paper presents a new approach for large-scale generator maintenance scheduling optimizations. The generator preventive maintenance scheduling problems are typical discrete dynamic n-dimensional vector optimization ones with several inequality constraints. The considered objective function to be minimized a subset of{{{{ { R}^{n } }}}} space is the variance (i.g., second-order momentum) of operating reserve margin to levelize risk or reliability during a year. By its nature of the objective function, the optimal solution can only be obtained by enumerating all combinatorial states of each variable, a task which leads to computational explosion in real-world maintenance scheduling problems. This paper proposes a new priority search mechanism based on each generator's discrete sensitivity value which was analytically developed in this study. Unlike the conventional capacity-based priority search, it can prevent the local optimal trap to some extents since it changes dynamically the search tree in each iteration. The proposed method have been applied to two test systems (i.g., one is a sample system with 10 generators and the other is a real-world lage scale power system with 280 generators), and the results anre compared with those of the conventional capacith-based search method and combinatorial optimization method to show the efficiency and effectiveness of the algorithm.

  • PDF

Small Signal Stability Analysis of Doubly Fed Induction Generator including SDBR

  • Shawon, Mohammad Hasanuzzaman;Al-Durra, Ahmed;Caruana, Cedric;Muyeen, S.M.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.31-39
    • /
    • 2013
  • This paper presents small signal stability analysis of a doubly fed induction generator (DFIG) based wind farm including series dynamic braking resistor (SDBR) connected at the stator side. A detailed mathematical model of wind turbine, DFIG machine and converters and SDBR is presented in this paper to derive the complete dynamic equations of the studied system. Small signal stability of this system is carried out by modal and sensitivity analysis, participation factors and eigenvalue analysis. Finally, this paper presents an analysis of the dynamic behavior of DFIG based wind farm under voltage dip condition with and without SDBR.

난수발생기와 일반화된 회귀 신경망을 이용한 DNA 서열 분류 (DNA Sequence Classification Using a Generalized Regression Neural Network and Random Generator)

  • 김성모;김근호;김병환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권7호
    • /
    • pp.525-530
    • /
    • 2004
  • A classifier was constructed by using a generalized regression neural network (GRU) and random generator (RG), which was applied to classify DNA sequences. Three data sets evaluated are eukaryotic and prokaryotic sequences (Data-I), eukaryotic sequences (Data-II), and prokaryotic sequences (Data-III). For each data set, the classifier performance was examined in terms of the total classification sensitivity (TCS), individual classification sensitivity (ICS), total prediction accuracy (TPA), and individual prediction accuracy (IPA). For a given spread, the RG played a role of generating a number of sets of spreads for gaussian functions in the pattern layer Compared to the GRNN, the RG-GRNN significantly improved the TCS by more than 50%, 60%, and 40% for Data-I, Data-II, and Data-III, respectively. The RG-GRNN also demonstrated improved TPA for all data types. In conclusion, the proposed RG-GRNN can effectively be used to classify a large, multivariable promoter sequences.

발전력 재배분을 이용하여 과도안정도를 향상하기 위한 Newton's Approach 응용 (Application of Newton's Approach for Transient Stability Improvement by Using Generation Rescheduling)

  • 김규호
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.68-75
    • /
    • 2013
  • This paper presents a scheme to improve transient stability using Newton's Approach for generation rescheduling. For a given contingency, the energy margin and sensitivities are computed. The bigger energy margin sensitivity of generator is, the more the generation of the generator effects to the transient stability. According to energy margin sensitivity, the control variables of generation rescheduling are selected. The fuel cost function is used as objective function to reallocate power generation. The results are compared to the results of time simulation to show its the effectiveness.

액체로켓엔진의 성능 민감도 분석 (Performance Sensitivity Analysis of Liquid Rocket Engine)

  • 조원국;박순영
    • 항공우주기술
    • /
    • 제12권1호
    • /
    • pp.200-206
    • /
    • 2013
  • 액체로켓엔진에서 추진제 밀도와 공급 압력 변화에 대한 성능 민감도를 분석하였다. 해석 프로그램은 터보펌프-가스발생기 연계시험 결과와 비교하여 1% 오차를 가지는 것으로 확인되었다. 연료 공급압력이 증가하면 혼합비 감소로 인해 엔진 연소압이 감소하였고 연료의 밀도가 증가하면 혼합비 감소에도 불구하고 추진제 유량이 증가하므로 엔진 연소압이 증가하는 것으로 예측되었다. 또한 산화제의 밀도가 증가되거나 공급압력이 증가하면 엔진의 연소압이 증가할 것으로 분석되었다.

선형 OTA를 이용한 삼각파/구형파 발생기 (A Triangular/Square Waveforms Generator Using Linear OTA's)

  • 박상렬;박지만정원섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.663-666
    • /
    • 1998
  • A triangular/square waveforms generator with current controllable frequency is described. The genertor utilizes operational transconductance amplifiers as switching elements. The circuit built with commercially available components exhibits good linearity of current to frequency and relatively low temperature sensitivity.

  • PDF

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

A Spring Back Calculation Model for the Sensitivity Analysis of Tube Design Parameters of Helical Steam Generator

  • Kim, Yong-Wan;Kim, Jong-In;Huh, Hyung;Park, Jin-Seok;Kim, Ji-Ho
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 추계학술발표회요약집
    • /
    • pp.355.2-355
    • /
    • 1999
  • The spnng back phenomena occurring in the coiling process of a steam generator tube induces the dimensional inaccuracy and makes the coiling procedure difficult. In this research, an analytical model was developed to evaluate the amount of the spring back for SMART steam generator tubes. The model was developed on the basis of beam theory and elastic-perfectly plastic material property. This model was extended to consider the effect of plastic hardening and the effect of the tensile force on the spring back phenomena. Parametric studies were performed for various design variables of steam generator tubes in order to minimize the spring back in the design stage. A sensitivity analysis has shown that the low yield strength, the high elastic modulus, the small helix diameter, and the large tube diameter result in a small amount of the spring back. The amount of the spring back can be controlled by the selection of adequate design values in the basic design stage and reduced to an allowable limit by the application of the tensile force to the tube during the coiling process.rocess.

  • PDF

The Level Control System Design of the Nuclear Steam Generator for Robustness and Performance

  • Lee, Yoon-Joon;Lee, Heon-Ju;Kim, Kyung-Yeon
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.157-168
    • /
    • 2000
  • The nuclear steam generator level control system is designed by robust control methods. The feedwater controller is designed by three methods of the H$\infty$, the mixed weight sensitivity and the structured singular value. Then the controller located on the feedback loop of the level control system is designed. For the system performance, the controller of simple PID whose coefficients vary with the power is selected. The simulations show that the system has a good performance with proper stability margins.

  • PDF