• 제목/요약/키워드: Generator Characteristics

검색결과 1,635건 처리시간 0.047초

대용량 발전기 고정자 바의 유전정접 특성 (Characteristics of Dissipation Factor in Large Generator Stator Bars)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.402-403
    • /
    • 2009
  • Accelerated aging tests were conducted under laboratory conditions on two generator stator bars. Electrical stress is applied in No. 1 model stator bar. Electrical and thermal stresses are applied in No. 2 model stator bar. As aging times increased from 0 to 11460h, dissipation factor($tan{\delta}$) test was performed on No. 1 and No.2 model stator bars. The ${\Delta}tan{\delta}$ of No. 1 and No. 2 stator bars increased with increased in aging time.

  • PDF

권선형 유도발전기 CVCF를 위한 2차 여자제어법에 관한 연구 (II) (A Study on the 2nd Excitation Method for CVCF Generation of Doubly-fed Induction Generator (II))

  • 안진우;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.45-48
    • /
    • 1990
  • This paper deals with the control strategy for constant voltage, constant frequency (CVCF) generation of doubly-fed Induction generator. As induction machine is a nonlinear and multivariable machine, so, the influential factors for CVCF generation of induction generator are the magnitude of output voltage, load current and its power factor, slip of the machine, etc. To get appropriate control scheme and to research the effect of its parameters, the control equation of induction machine is derived and tested. The derived condition is very useful for the CVCF control of the machine and for determing the characteristics of the system. The simulation results show that magnetizing reactance and rotor resistance is a very important parameter in this control system.

  • PDF

영구자석의 Halbach 배열에 의한 자기회로 특성과 초고속전동발전기에의 응용 (The magnetic circuit characteristics by Halbach array of permanent magnet and the application to the high speed motor-generator)

  • 장석명;서진호;박찬일;최상규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.71-73
    • /
    • 1996
  • Klaus Halbach has suggested the novel permanent magnet array using advanced analytical approaches in 1979. We utilize this Halbach array to compose the field system of high speed motor-generator. The ferro-magnetic materials of the electric machines cause the fatal energy loses in high frequency. But Halbach array enables to make the various field distribution without ferro-magnetic materials. Therefore, the energy loses can be reduced. This paper presents the magnetic characterics of Halbach array and the application to the motor-generator.

  • PDF

Fretting-Wear Characteristics of Steam Generator Tubes by Foreign Object

  • Jo Jong Chull;Jhung Myung Jo;Kim Woong Sik;Choi Young Hwan;Kim Hho Jung;Kim Tae Hyung
    • Nuclear Engineering and Technology
    • /
    • 제35권5호
    • /
    • pp.442-453
    • /
    • 2003
  • This study investigates the safety assessment of the potential for fretting-wear damages on steam generator (SG) U-tubes caused by foreign object in operating nuclear power plants. The operating SG shell-side flow field conditions are obtained from three-dimensional SG flow calculation using the ATHOS3 code. Modal analyses are performed for the finite element modelings of U-tubes to get the natural frequency, corresponding mode shape and participation factor. The wear rate of U-tube caused by foreign object is calculated using the Archard formula and the remaining life of the tube is predicted. Also, discussed in this study is the effect of the flow velocity and vibration of the tube on the remaining life of the tube.

증기발생기 전열관의 파열강도에 미치는 외압의 영향 (Effect of External Pressure on the Burst Strength of Steam Generator Tube)

  • 조성근;배봉국;석창성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.353-358
    • /
    • 2004
  • Tracing the study of the burst test of steam generator tube, few studies have been reported to effect of external pressure acting on secondary-side in service condition. In this study the burst tests of Inconel 690TT were conducted in order to evaluate burst strength characteristics under the effect of external pressure. We obtained the result that the burst strength of Inconel 690TT increased when external pressure increased while both total circumferential elongation and uniform burst elongation were not affected. Also, according to the increased of external pressure, the size of the burst opening became smaller and the tear was getting severe.

  • PDF

소형 독립형 풍력발전기의 진동 모니터링 및 분석 (Vibration Monitoring and Analysis of a Small Stand Alone Wind Turbine Generator)

  • 김석현;유능수;남윤수;이정완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.64-67
    • /
    • 2005
  • A vibration monitoring system for a small size wind turbine (WIT) is established and operated. The monitoring system consists of monolithic integrated chip accelerometer for vibration monitoring, anemometers for wind data acquisition and auxiliary sensors for atmospheric data. Using the monitoring system, vibration response of a 6kW stand alone WIT generator is investigated. Acceleration data of the WIT tower under various operation condition is acquired in real time using LabVIEW and the data are remotely transferred from the test site to the laboratory in school by internet. Vibration response characteristics of the tower structure are diagnosed in the aspect of stability of W/T. Wind data and electrical power performance are also investigated with the stability problem.

  • PDF

풍력발전기 소음 성능 실증 (Noise Performance Test and Evaluation of a Wind Turbing Generator)

  • 김석현;김태형;박무열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.241-245
    • /
    • 2005
  • This study introduces the wind turbine (W/T) noise evaluation procedure required in the international standard (IEC 61400-11) and monitoring system for the evaluation. Noise emission characteristics of a 750kW W/T generator is investigated. Test and evaluation are performed on J48 W/T model which is under operation in Daekwanryung Wind Test Site. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level and tonality of the W/T are estimated under the wind speeds required by the international standard.

  • PDF

양수발전소용 펌프수차${\cdot}$발전기 전동기 축계의 진동해석 (Vibration Analysis of Pump/Turbine and Generator/Motor Rotor System for Pumped Storage Power Stations)

  • 양보석;최병근;김용한;하현천
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.39-45
    • /
    • 1999
  • Pumped-storage power plants pumps the water from the lower reservoir to the upper reservoir using the extra electric power at night and generates electric power in the daytime. Currently it tends to be a high-head large-capacity machine. In this paper, we developed the computer programs for vibration analysis of the pump/turbine and generator/motor rotor system considering electromagnetic force, hydrodynamic unbalance force, dynamic characteristics of guide bearings and add mass of water. This program was verified by applying it to the real model and calculating the critical speed, natural mode and unbalance response.

  • PDF

저온 플라즈마 공정용 펄스발생 전원장치의 성능시험 (Test Results of Pulsed Power Supply for Nonthermal Plasma Process)

  • 장성덕;변영철;조무현;신동남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF

대용량 발전기 고정자 권선의 절연열화 특성 (Characteristics of Insulation Aging in Large Generator Stator Windings)

  • 김희동;이영준;주영호
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1375-1379
    • /
    • 2009
  • Insulation tests have been performed on two generator stator bars under accelerated aging under a laboratory environment. Electrical stress was applied to stator bar No.1, and electrical and thermal stresses were applied to stator bar No.2. Nondestructive stator insulation tests including the ac current, dissipation factor($tan{\delta}$), and partial discharge tests have been performed on both bars as the bars were aged for 11460 hours. Experimental test results show that ${\Delta}I$, ${\Delta}tan{\delta}$, and partial discharge of No. 1 and No.2 stator bars increased with increased in aging time. It has been concluded from the test that the stator insulation of the two generators are in good condition.