• Title/Summary/Keyword: Generation rate

Search Result 3,010, Processing Time 0.036 seconds

Estimation of Freight Trip Generation Rates based on Commodity Flow Survey in Korea

  • Park, Minchoul;Sung, Hongmo;Chung, Sungbong
    • International Journal of Railway
    • /
    • v.5 no.4
    • /
    • pp.139-143
    • /
    • 2012
  • In Korea, almost 700 industrial parks are under operation. Generally, industrial parks consist of national industrial parks and local industrial parks which are managed by a central government and by local governments respectively. The developing countries such as Korea, China and Vietnam etc. have constructed many industrial parks, which result in the change of land use pattern and also affect future trip demands. Therefore, in estimating traffic demands, it is very important to consider the industrial park development. This study aims to improve the methodology in estimating a freight trip generation rate with the data based on a nationwide commodity freight survey. The result showed that it is desirable to apply freight trip generation rate by the industry sector in estimating freight trip generations and using the production area of firm as an indicator. Specially, the reliability of the rates through a survey could be made sure because a sample rate based on firms in industrial parks was over 25% and the response rate was over 67%. The sample rate and response rate are very superior as compared to surveys conducted in many other countries. Because industrial parks have significant effects on forecasting transportation demand in pre-feasibility studies of transport and logistics projects, it is expected that the accuracy of freight trip demands would be improved through the results of this study.

Avoided Generation Costs of IPPS Considering Forced Outage Rate and Economic Loading Order (고장정지율과 경제적 투입순서를 고려한 민자발전소의 회피발전비용 계산)

  • 원종률;박종배;김진호
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.47-58
    • /
    • 2002
  • This paper presents a new method for the evaluation of avoided generation costs. Unlike conventional load decrement method, it exactly considers forced outage rate and economic loading order of IPPs (Independent Power Producers). Therefore we can provide exact generation avoided costs of IPPs by the developed method. Because probabilistic simulation is conducted in this method, effects on the costs of IPPs are exactly considered. Also we suggest an allocation method of avoided generation costs by participation factor. In the case studies we have shown avoided generation costs considering loading order and forced out-age rate by using this method.

Speech rate in Korean across region, gender and generation (한국어 발화 속도의 지역, 성별, 세대에 따른 특징 연구)

  • Lee, Nara;Shin, Jiyoung;Yoo, Doyoung;Kim, KyungWha
    • Phonetics and Speech Sciences
    • /
    • v.9 no.1
    • /
    • pp.27-39
    • /
    • 2017
  • This paper deals with how speech rate in Korean is affected by the sociolinguistic factors such as region, gender and generation. Speech rate was quantified as articulation rate (excluding physical pauses) and speaking rate (including physical pauses), both expressed as the number of syllables per second (sps). Other acoustic measures such as pause frequency and duration were also examined. Four hundred twelve subjects were chosen from Korean Standard Speech Database considering their age, gender and region. The result shows that generation has a significant effect on both speaking rate and articulation rate. Younger speakers produce their speech with significantly faster speaking rate and articulation rate than older speakers. Mean duration of total pause interval and the total number of pause of older speakers are also significantly different to those of younger speakers. Gender has a significant effect only on articulation rate, which means male speakers' speech rate is characterized by faster articulation rate, longer and more frequent pauses. Finally, region has no effect both on speaking and articulation rates.

Economic Analysis for Introduction to Department Building of Co-generation (백화점용 건물에 열병합 도입에 따른 경제성 분석)

  • 김응상
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.92-100
    • /
    • 2002
  • In respect of global environment protection and efficient utilization of energy, co-generation systems, which have greatly higher efficiency than the other generations, have been developed and put to practical use. Assuming that the co-generation system would be operating in H-Department of Kwang-ju city, this paper calculates the difference between the heat and electricity rates by the conventional method and the co-generation system considers the cost of new investment and analyzes introduction economics based on the return on investment. The introduction is turned out to be recommendable, since the return of investment for co-generation equipment is about five years when the co-generation profits in heat and electricity rate. Additionally, accounting for interest rate drop, improvement of environmental matters or electricity rate increase, it is shown to be even more economical.

Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System (확산형 흡수식 냉동시스템의 기포펌프 성능실험)

  • 이재효;정의갑;윤재호;정의갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

Generation of emulsions due to the impact of surfactant-laden droplet on a viscous oil layer on water (벤츄리 노즐 출구 형상과 작동 조건에 따른 캐비테이션 기포 발생 특성 연구)

  • Changhoon Oh;Joon Hyun Kim;Jaeyong Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.94-102
    • /
    • 2023
  • Three design parameters were considered in this study: outlet nozzle angle (30°, 60°, 80°), neck length (1 mm, 3 mm), and flow rate (0.5, 0.6, 0.7, 0.8 lpm). A neck diameter of 0.5 mm induced cavitation flow at a venture nozzle. A secondary transparent chamber was connected after ejection to increase bubble duration and shape visibility. The bubble size was estimated using a Gaussian kernel function to identify bubbles in the acquired images. Data on bubble size were used to obtain Sauter's mean diameter and probability density function to obtain specific bubble state conditions. The degree of bubble generation according to the bubble size was compared for each design variable. The bubble diameter increased as the flow rate increased. The frequency of bubble generation was highest around 20 ㎛. With the same neck length, the smaller the CV number, the larger the average bubble diameter. It is possible to increase the generation frequency of smaller bubbles by the cavitation method by changing the magnification angle and length of the neck. However, if the flow rate is too large, the average bubble diameter tends to increase, so an appropriate flow rate should be selected.

Annual energy yield prediction of building added PV system depending on the installation angle and the location in Korea (건물적용 태양광발전시스템의 국내 지역에 따른 설치각도별 연간 전력생산량 예측에 관한 연구)

  • Kim, Dong Su;Shin, U Cheol;Yoon, Jong Ho
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • There have distinctly been no the installation criteria and maintenance management of BIPV systems, although the BIPV market is consistently going on increasing. In addition, consideration of the BIPV generation quantity which has been installed at several diverse places is currently almost behind within region in Korea. Therefore, the main aim of this study is to evaluate the BIPV generation and to be base data of reducing rate depending on regional installation angles using PVpro which was verified by measured data. Various conditions were an angle of inclination and azimuth under six major cities: Seoul, Daejeon, Daegu, Busan, Gwangju, Jeju-si for the BIPV system generation analysis. As the results, Seoul showed the lowest BIPV generation: 1,054kWh/kWp.year, and Jeju-si have 5percent more generation: 1,108.0kWh/kWp.year than Seoul on horizontal plane. Gwangju and Daejeon turned out to have similar generation of result, and Busan showed the highest generation: 1,193.5kWh/kWp.year, which was increased by over 13percent from Seoul on horizontal plane. Another result, decreasing rate of BIPV generation depending on regional included angle indicate that the best position was located on azimuth: $0^{\circ}$(The south side) following the horizontal position(an angle of inclination: $30^{\circ}$). And the direction on a south vertical position(azimuth: $0^{\circ}$, an angle of inclination: $90^{\circ}$) then turned out reducing rate about 40percent compared with the best one. Therefore, these results would be used to identify the installation angle of the BIPV module as an appropriate position.

Enhancing Effect of Organic Substances on Hydroxyl Radical Generation During Ozonation of Water: Stopped-Flow ESR Technique

  • Han, Sang-Kuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.12
    • /
    • pp.1907-1910
    • /
    • 2004
  • Generation of hydroxyl radical, one of their major active species in ozonation of water was directly observed with spin-trapping/electron spin resonance (ESR) technique using 5,5-dimethyl-pyrrolidine-1-oxyl (DMPO) as a spin-trapping reagent. Hydroxyl radical was trapped with DMPO as a stable radical, DMPO-OH. 80 mM of ozone produced $1.08{\times}10^{-6}$M of DMPO-OH, indicating that 1.4% of ${\cdot}$OH is trapped with DMPO if ${\cdot}$OH is produced stoichiometrically from ozone. Humic acid suppressed DMPO-OH generation in a dose-dependent manner. Generation rate of DMPO-OH was determined with ESR/stopped-flow measurement. Phenol derivatives increased the amount and generation rate of DMPO-OH, indicating that phenol derivatives enhance·OH generation during ozonation of water.

The Effect of Current Pulsing Parameters on the Spatter Generation Rate during $CO_2$Shielded Gas Metal Arc Welding ($CO_2$ 용접에서 전류 펄스 조건이 스패터 발생에 미치는 영향)

  • 강덕일;최재호;장영섭;김용석
    • Journal of Welding and Joining
    • /
    • v.16 no.4
    • /
    • pp.63-72
    • /
    • 1998
  • In this study, the effects of the current pulsing conditions, on the spatter generation rate during the $CO_2$ gas metal arc welding (GMAW) were investigated. Normally using the inverter type power supply, of which the welding current waveform was regulated to reduce the spatter generation rate, but in this study pulsing was imposed on the welding current. Observation of the metal transfer phenomena during the pulsed current GMAS indicated that the droplet transfer from the electrode via the short circuit transfer and the repelling transfer mode could be minimized by selecting optimum combinations of pulsing parameters, which include base and peak current, base and pak duration. It was also demonstrated in this study that proper combinations of the pulsing parameters led to reduce generation of spatters during GMAW shielded by $CO_2$ gas.

  • PDF

Relationship between Spatter Generation and Waveform Factors in Transitional Condition of $CO_2$ Welding ($CO_2$ 용접의 천이이행 조건에서 스패터 발생과 파형인자와의 관계)

  • 강봉용;이창한;김희진;장희석
    • Journal of Welding and Joining
    • /
    • v.16 no.4
    • /
    • pp.39-46
    • /
    • 1998
  • $CO_2$ gas shielded arc welding has been characterized with its harsh arc compared to Ar-based shielding gases and with its high level of spattere specially in welding current range of 250~300 amperes. In this range of welding current, the metal transfer mode showed to be changed from short circuit to globular with the increase of welding voltage resulting in so-called the transitional mode in which both modes of transfer appeared together. To characterize the transitional mode, the short circuit events were divided into two groups, i.e. normal short circuit (N.S.C) which has short circuit time $(t_s)$ over 2msec and instantaneous short circuit (I.S.C) of $t_s$$\leq$2msec. The experimental results showed that the number of N.S.C decreased almost linearly with the increase of welding voltage and appeared to be not related with spatter generation rate. However I.S.C became to be pronounced in the transitional condition and its number reached the maximum value at around 29.0 volts. Considering the relation with the spatter generation rate, it was found that the number of I.S.C had a very strong correlation with the spatter generation rate of the transitional condition. It was further demonstrated that spatter generation rate decreased quite linearly with the decrease of I.S.C frequency. It implies that I.S.C is the most important waveform factor controlling the spatter generation of the transitional mode, i.e. in the middle range of welding current. Based on these results, It was discussed that in the transitional mode the basic concept of waveform control for suppressing spatter generation would be different from the one applied for typical short circuit transfer mode of low welding current.

  • PDF