• Title/Summary/Keyword: Generation rate

Search Result 3,001, Processing Time 0.025 seconds

Heat Generation Model of Angular Contact Ball Bearing with Oil-Air Lubrication

  • Na, Hee-Hyeong;Rhim, Yoon-Chul
    • KSTLE International Journal
    • /
    • v.1 no.1
    • /
    • pp.63-68
    • /
    • 2000
  • Angular contact ball bearings are mainly used in the spindle, which requires high speed and stiffness. The heat generation is studied by experiments and simulations using a pair of angular contact ball bearings. The temperature variation of inner and outer races and the temperature increment distribution are measured by using thermocouples for the rotational speed, preload, viscosity of lubricant. The measured values from experiments are used to estimate the heat conduction rate. The method of oil-air lubrication is used for the experiment. The amount of conduction heat transfer to the test spindle and the convection heat transfer coefficients long the spindle are computed by using inverse method with temperature increment distribution. Total heat generation rate is estimated with the heat partition rate which is calculated from temperatures of inner and outer races. In addition, the empirical factor of oil-air lubrication method for Palmgren's heat generation model is suggested. The empirical friction coefficients, which are obtained from the experiments, depend on the preload condition, and can give us more accurate estimation of the heat generation in ball bearings.

  • PDF

Choice of Efficient Sampling Rate for GNSS Signal Generation Simulators

  • Jinseon Son;Young-Jin Song;Subin Lee;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.3
    • /
    • pp.237-244
    • /
    • 2023
  • A signal generation simulator is an economical and useful solution in Global Navigation Satellite System (GNSS) receiver design and testing. A software-defined radio approach is widely used both in receivers and simulators, and its flexible structure to adopt to new signals is ideally suited to the testing of a receiver and signal processing algorithm in the signal design phase of a new satellite-based navigation system before the deployment of satellites in space. The generation of highly accurate delayed sampled codes is essential for generating signals in the simulator, where its sampling rate should be chosen to satisfy constraints such as Nyquist criteria and integer and non-commensurate properties in order not to cause any distortion of original signals. A high sampling rate increases the accuracy of code delay, but decreases the computational efficiency as well, and vice versa. Therefore, the selected sampling rate should be as low as possible while maintaining a certain level of code delay accuracy. This paper presents the lower limits of the sampling rate for GNSS signal generation simulators. In the simulation, two distinct code generation methods depending on the sampling position are evaluated in terms of accuracy versus computational efficiency to show the lower limit of the sampling rate for several GNSS signals.

Effects of Environmental Variables on Hydrogen Generation from Alkaline Solutions using used Aluminum Cans (알칼리 용액에서 알루미늄 재활용 캔을 이용한 수소생산에 미치는 환경 인자의 영향)

  • Yun, Kwi-Sub;Park, Chan-Jin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • This study examined the effect of environmental variables, such as the NaOH concentration and solution temperature, on the rate of hydrogen generation from NaOH solutions through the corrosion of used aluminum cans as a potential candidate material for the safe and economic production of hydrogen. Corrosion of the used aluminum cans was promoted by increasing the NaOH concentration and solution temperature because of the loss of aluminum passivity. The measured rate of hydrogen generation from the NaOH solutions increased with increasing NaOH concentration due to the catalytic activity of NaOH in the hydrolysis process. However, at higher solution temperatures, the rate of hydrogen generation rate was less affected by the NaOH concentration than that at lower temperature.

Estimation of Parking Requirements of an Apartment (공동주택 주차장 설치기준)

  • Oh, Jae Hak;Park, Junsik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4D
    • /
    • pp.451-457
    • /
    • 2009
  • This study verifies parking requirements of an apartment suggested in parking generation law in Korea through analysing the surveyed parking generation rate. It is revealed that the parking requirements according to the gross floor area in parking generation law is similar to the surveyed parking generation rate as an average but the differences of each requirements by region and apartment's size are not significant. Parking generation rate results in strong correlation with the number of household rather than the gross floor area, and the new requirements suggested in this study, based on the number of household, shows significant difference by region and apartment's size, which is consistent with common sense. This study suggests parking requirements of an apartment, based on the number of household, by region and apartment's size for 6 groups. Surveyed parking generation rate of each group is fitted to statistical distribution and the mean value of fitted statistical distribution is suggested as the parking requirements of each group. Parking requirements based on the number of household is easily recognized of its relative and absolute value, and moreover is consistent with the surveyed parking generation rate.

Measurement of Waste Generation in Seawater Aquaria by Common Conger (Astroconger myriaster) arld Olive Flounder (Paralichyhus olivaceus) (해수활어수조에서 붕장어 (Astroconger myriaster)와 넙치 (Puralichyhus olivaceus)에 의한 오염물 발생량 산정)

  • SUH Kuen-Hack;SHIN Jeong-Sik;JO Jae-Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.6
    • /
    • pp.492-497
    • /
    • 2004
  • Waste concentration and waste generation rate in seawater aquaria by common conger (Astrocongey myriaster) and olive flounder (Paralichyhus olivaceus) were investigated. The initial fish density of common conger and olive flounder were $3{\%}\;and \;2.8{\%}$ of total weight of aquarium water, respectively Wastes in the seawater aquaria, such as protein, total suspended solid (TSS), ammonia, turbidity and chemical oxygen demand (COD) increased with days after stocking. Protein generation rate of common conger increased until 1 day after stocking while that of olive flounder increased until 3 days. The average protein generation rates of common conger and olive flounder were $0.28g/kg{\cdot}day\;and\;0.21g/kg{\cdot}day$, respectively. The trends of other waste generation rate were similar to protein generation rate.

The method for the classification according to their kinds and the estimation of unit generation rate for promoting recycling of construction and demolition(c&d) debris (건설폐기물 재활용촉진을 위한 종류별 분류 및 발생원단위 산정 방안)

  • Lee, Hi Sun;Kim, Dong Sik
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.1
    • /
    • pp.86-100
    • /
    • 2008
  • It is needed to classify the kinds of construction and demolition(c&d) debris to 6 catagories of waste concrete, waste asphalt concrete, waste wood, scraps, combustible waste and incombustible waste in order to properly do a separate discharge and to estimate unit generation rate in construction site. Also, in this case, the unit treating cost for mixed wastes should be applied with the unit treating cost for combustible waste. The construction standard materials estimation data is used for basic data for estimating unit generation rate. The mixed wastes in this data should be classified to waste wood, combustible waste and incombustible waste, and their ratio is obtained by using the unit generation rate of Asia Pacific Environment and Management Institute and Seoul Metropolitan Development Institute. The waste amounts generated from newly-built construction can be obtained from multiplying the loss rate by the amount of materials used from construction standard estimation data. Also, those from dismantling construction can be obtained by subtracting waste amount generated during newly-built construction from total input amount of materials in newly-built construction. Those in two cases can be used in construction site. It can be used for estimating the amount generated and establishing the treating plan in the case of setting up the policy of waste management and doing the environment impact assessment.

  • PDF

A Study on the Optimal Condition for Minimizing Spatter Generation at GMAW Robot (GMAW Robot에서 Spatter최소 발생 조건에 관한 연구)

  • Kim, Han-Sik;Han, Shin-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.2
    • /
    • pp.83-91
    • /
    • 2008
  • GMAW(Gas Metal Arc Welding) processes are usually used in industrial side in order to get its high productivity. But those are only adopted in the semi-automated welding equipment because of a lot of welding spatters. Many industrial robot actually percents from being engaged in the welding processes. The welding spatter problem of causes blocking them being a fully automated welding process.This study was carried out to investigate the optimal conditions for minimizing welding spatter generation at GMAW robot. The spatter can be significantly reduced below 2% of welding spatter generation at the following conditions ; First, below 18V at the wire-feed rate 2.0mm/min Second, below 23V at the wire-feed rate 3.6mm/min Third, below 24V at the wire-feed rate 5.5mm/min.

  • PDF

Respiration rate of the Fuji apple according to the ULO storage conditions (ULO 저장에서의 사과 Fuji의 호흡속도)

  • Gang, Jun-Su;Lee, Ho-Jae;Choe, Jong-Uk
    • Food Science and Preservation
    • /
    • v.1 no.2
    • /
    • pp.87-92
    • /
    • 1994
  • For the measurement of the change of respiration rate caused by the gas content of storage atmosphere which furnishes important data for the interpretation of ULO storage, GC was used. It has been shown that the respiration rate and respiratory heat generation rate of Fuji apple is more than doubled in normal low temperature storage when compared with ULO storage, and that in ULO storage the respiration rate and respiratory heat generation rate directly proportional to the concentration of O2 in storage atmosphere as well as inversely proportional to that of CO2. It was possible to establish a functional formula for the respiratory heat generation rate of Fuji apple in all the storage conditions in terms of u=-0.7638+0.0003 O2-0.0007 log(CO2)+0.1369 log(Tb) concerning temperature and the concentration of O2 and CO2

  • PDF

Multi-Stage Generation Allocation Game Considering Ramp-rate Constraints (경쟁적 전력시장에서 발전기 증감발률을 고려한 다중시간 발전량 배분 게임)

  • Park, Yong-Gi;Park, Jong-Bae;Roh, Jae-Hyung;Kim, Hyeong-Jung;Shin, Jung-Rin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.509-516
    • /
    • 2011
  • This paper studies a novel method to find the profit-maximizing Nash Equilibriums in allocating generation quantities with consideration of ramp-rates under competitive market environment. Each GenCo in a market participates in a game to maximize its profit through competitions and play a game with bidding strategies. In order to find the Nash equilibriums it is necessary to search the feasible combinations of GenCos' strategies which satisfy every participant's profit and no one wants various constraints. During the procedure to find Nash equilibriums, the payoff matrix can be simplified as eliminating the dominated strategies. in each time interval. Because of the ramp-rate, generator's physically or technically limits to increase or decrease outputs in its range, it can restrict the number of bidding strategies of each generator at the next stage. So in this paper, we found the Nash Equilibriums for multi-stage generation allocation game considering the ramp-rate limits of generators. In the case studies, we analyzed the generation allocation game for a 12-hour multi-stage and compared it with the results of dynamic economic dispatch. Both of the two cases were considered generator's ramp-rate effects.