• Title/Summary/Keyword: Generation Type

Search Result 2,879, Processing Time 0.026 seconds

A Study on Power Storage Apparatus of combined Generation System 3kW Proto Type Photovoltaic/Wind Generation (3kW proto type 태양광/풍력 복합발전시스템의 전력보상장치에 관한 연구)

  • Park Se-Jun;Kang Byung-Bog;Yoon Jeong-Phil;Lim Jung-Yeol;Cha In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.74-77
    • /
    • 2002
  • Combined generation system of Photovoltaic and wind generation have shortcoming that is different output power according to change of weather. So, the combined generation system is required backup system that such as a storage battery to supply energy, when not enough photovoltaic and wind power source for power supply equally and continually, because the energy source is changeable and stable through change of weather as irradiation, temperature, wind speed, wind direction, seasons, etc..

  • PDF

Effect of the Biased Third Electrode of a Wire-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics (선대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 바이어스된 3전극의 영향)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.648-652
    • /
    • 2008
  • Corona discharge and ozone generation characteristics of a wire-plate plasma reactor, with a biased third electrode, have been investigated with an emphasis on the role of the bias voltage and frequency applied on the third electrode. It was found that the wire-plate plasma reactor, with the biased third electrode, had a switching characteristic on its I-V characteristics for negative and positive discharges, which is very different from that of a conventional wire-plate plasma reactor without the third electrode. As a result, the corona discharge and ozone generation characteristics of the proposed plasma reactor could be controlled by adjusting the bias voltage and frequency of the third electrode. The corona onset and breakdown voltages, and ozone generation and yield, were increased compared with those of without the third electrode. These, however, reveal the effectiveness of the biased third electrode.

A study of high-efficiency rotating condensing hybrid solar LED street light module system (고효율 회전 집광형 하이브리드 태양광 LED 가로등 모듈 시스템 연구)

  • Min, Kyung-Ho;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.50-55
    • /
    • 2021
  • Solar power generation, which is one of the methods of using solar energy, has a high possibility of practical implementation compared to other renewable energy power generation, and it has the characteristic that it can generate as much power as needed in necessary places. In addition, maintenance is easy, unmanned operation is possible, and power management can be performed more efficiently if operated in a hybrid method with existing electric energy. Therefore, in this study, numerical analysis using a computer program was performed to analyze the efficient operation and performance improvement of solar energy of the rotating condensing type solar LED street lamp. As a result, the two-axis tracking type could obtain 15.23 % more electricity per year than the fixed type, and additional auxiliary power generation was required for the fixed type by 19 % per year than the tracking type. As a result of computational fluid dynamics(CFD) simulation for PV module surface temperature prediction, the The surface temperature of the Photovoltaics(PV) module incident surface was predicted to be about 10℃ higher than that of the fixed type.

The utility of digital evaluation based on automatic item generation in mathematics: Focusing on the CAFA system (수학교과에서 자동문항생성 기반의 디지털 평가 활용 방안: CAFA 시스템을 중심으로)

  • Kim, Sungyeun
    • The Mathematical Education
    • /
    • v.61 no.4
    • /
    • pp.581-595
    • /
    • 2022
  • The purpose of this study is to specify the procedure for making item models based on ontology models using automatic item generation in the mathematics subject through the CAFA system, and to explore the generated item instances. As an illustration for this, an item model was designed as a part of formative assessment based on the content characteristics, including concepts and calculations, and process characteristics, including application, using the representative values and the measures of dispersion in Mathematics of the 9th grade based on the evaluation criteria achievement standards. The item types generated in one item model were a best answer type, a correct answer type, a combined-response type, an incomplete statement type, a negative type, a true-false type, and a matching type. It was found that HTML, Google Charts, TTS, figures, videos and so on can be used as media. The implications of the use of digital evaluation based on automatic item generation were suggested in the aspects of students, pre-service teachers, general teachers, and special education, and the limitations of this study and future research directions were presented.

바이러스 외피단백질 유전자로 형질전환된 연초 식물체의 TMV 저항성 발현 및 유전자 안정성

  • 박성원;이기원;이청호;이영기;강신웅;최순용
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.1
    • /
    • pp.77-81
    • /
    • 1999
  • Tobacco plants(Nicotiana tabacum cv. NC82) transformed with TMV CP cDNA were self-fertilized until 8th generation (R$_{8}$), and the transgenic plants from 6th to 8th generation were analized for their resistance to tobacco mosaic virus(TMV) and stability of the gene expression. The 6th generation of the plants(R$_{6}$) showed high resistance(81-91 %) to TMV at eight weeks after artificial inoculation with the virus. The transgenic cell line 601 was the most prominant in the expression of resistance. 98 % of the plants showed no symptom without any agronomic phynotepe variation when they were inoculated with the virus in a experimental field. However, 2% of the plants were revealed as delay type of symptom with mild mosaic on a few leaves. The viral resistance in greenhouse tests of the 7th generation (R$_{7}$) was 54-64%, and the number of delay type plants were increased than that of 6th generation plants. In the 8th generation, 81 % of the plants was complete resistant to the virus. The TMV CP cDNA of the transgenic plants of each generation was also confirmed by genomic PCR, and there was no systemic viral multiplication in the resistant plants. It suggests that the viral resistance and gene expression of the transgenic plants might be stable through the generations.ons.s.

  • PDF

Simulation Method of Photovoltaic Generation Systems using EMTP Type Simulators (EMTP형 시뮬레이터를 이용한 태양광발전시스템 모의 방법)

  • Park Minwon;Yu In-Keun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.6
    • /
    • pp.303-308
    • /
    • 2005
  • As the cost of photovoltaic(PV) generation systems continues to decrease, utility interactive systems are becoming more economically viable. Furthermore, increases in consumer awareness correspond to a willingness to pay a premium price for clean electrical energy generated using renewable energy resources. Especially, PV generation systems, in particular, is undergoing a rapid expansion-showing an industrial growth of approximately 40$\%$ per year in the worldwide, as PV cell and systems technology improve new markets become increasingly accessible. This has resulted in an increased demand for the simulation scheme and operational technologies of utility interactive PV devices and systems. The simulation schemes that can be applied to the utility interactive PV generation systems readily and cheaply under various conditions considering the sort of solar cell, the capacity of systems and the converter system as well are strongly expected and emphasized among researchers. So far, authors have been introducing the simulation method of PV generation systems with several papers. In this paper, authors introduce the simulation way of PV generation systems using EMTP type simulators; EMTP/ATP, EMTDC/PSCAD, RTDS, with each examples. And, by connecting the voltage amplifier to the RTDS a novel simulation method which is extremely close to the real condition of PV generation system is also introduced.

A High Efficiency Ozone Generation Using a Electrode-edge Discharge and a Dielectric-Barrier Discharge (전극연면방전(電極沿面放電)과 유전체장벽방전(誘電體障壁放電)을 공용(共用)한 고효율(高效率) 오존발생(發生))

  • Choi, Jae-Gu;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1410-1412
    • /
    • 1995
  • A high efficiency ozone generation using both of a electrode-edge discharge and a dielectric-harrier discharge from a modified silent type ozone generator has been proposed and studied for small scale applications. It is found that the output ozone concentration of the proposed generator depended greatly upon the air gap spacing and the applied power frequency and voltage on the ozone generation. The ozone generator showed higher ozone concentration than the same size of the ceramic type surface ozone generator(Masuda type one). And, it is found that the generator had a potential to be used as an ozone generator for small scale applications.

  • PDF

Effect of a Cylindrical Third Electrode of a Point-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics (침대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 원통형 3전극의 영향)

  • Moon, Jae-Duk;Jung, Ho-Jun;Jung, Jae-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.933-937
    • /
    • 2007
  • A point plate type nonthermal plasma reactor, with a grounded cylindrical third electrode which closely- encompasses the needle point, have been investigated with an emphasis on the role of the third electrode. It was found that the point plate airgap, with the grounded third electrode, had a switching characteristic on its I V characteristics for negative and positive discharges, which is very different from that of a conventional point plate airgap without a third electrode. The corona discharge and ozone generation characteristics of the plasma reactor with the grounded cylindrical third electrode, such as the corona onset voltage. the breakdown voltage. the corona current. and the amount of output ozone, were influenced significantly by the height of the third electrode. and these characteristics can be controlled by adjusting the height of the third electrode.

Pretilt Angle Generation for Nematic Liquid Crystal on a Homeotropic Alignment Layer (수직배향층에서의 네마틱액정의 프리틸트각 발생)

  • 서대식;김형규;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.2
    • /
    • pp.130-132
    • /
    • 2001
  • The mechanisms of pretilt angle generation in nematic liquid crystal (NLC) with negative dielectric anisotropy on a rubbed polyimide (PI) surface for homeotropic alignment were studied. The pretilt angle of negative type NLC was smaller than that of the positive type NLC for all rubbing strength regions on the rubbed PI surface. The pretilt angle generated in NLC does not attributable to steric interaction between the fluorine moiety of NLC and the polymer surface on the rubbed PI surface. Consequently, the mechanism of the pretilt angle generation for homeotropic alignment is different from the one for homogeneous alignment.

  • PDF

NOISE CHARACTERISTICS OF SIMPLIFIED FORWARD-TYPE RESONANT CONVERTER

  • Higashi, Toru
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.559-562
    • /
    • 2000
  • The problem of noise generation due to PWM switched-mode power converter has been widely noticed from the viewpoint of Electromagnetic Interference(EMI). Many kings of topologies for resonant converters have been developed both to overcome this noise problem and to attain high power efficiency. It is reported in references that resonant converters which are derived from PWM converter using resonant switch show much lower noise characteristics than PWM converter, and that current-mode resonant converter is more sensitive to stored charge in rectifying diode than voltage-mode counterpart concerning surge generation at diode’s turn-off. On the other hand, above mentioned resonant converters have defect of high-voltage stress on semiconductor switch and complicated circuit configuration. Hence, the simplified Forward-type resonant converter has been proposed and investigated due to its prominent features of simplicity of circuit configuration, low voltage stress and high stability. However, its noise characteristics still remain unknown. The purpose of this paper is to study quantitatively the noise characteristics of this simplified Forward-type resonant converter by experiment and analysis. The influence of parasitic elements and stored charge in rectifying diode on noise generation has been clarified.

  • PDF