• Title/Summary/Keyword: Generation Type

Search Result 2,890, Processing Time 0.034 seconds

Analytical Approach for Optimal Allocation of Distributed Generators to Minimize Losses

  • Kaur, Navdeep;Jain, Sanjay Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1582-1589
    • /
    • 2016
  • In this paper the integration of Distributed Generation (DG) in radial distribution system is investigated by computing the optimal site and size of DG to be placed. An analytical expression based on equivalent current injection has been derived by utilizing topological structure of radial distribution system to find optimal size of DG to minimize losses. In the presented formulation, the optimal DG placement is obtained without repeatedly computing the load flow. The proposed formulation can be used to find the optimal size of all types of DGs namely Type-I, Type-II, Type-III and Type-IV DGs. The investigations are carried out on IEEE 33-bus and 69-bus radial distribution systems. The optimal DG placement results into reduction in active and reactive power losses and improvement in voltage profile of the buses.

Characteristics of Ozonizers Manufactured in Energy & Environment Electromagnetic Lab. of Yeungnam University

  • Song, Hyun-Jig;Kim, Ki-Chai;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.11-16
    • /
    • 1999
  • Discharge characteristics research for high voltage and large current electric machinery design, the development of ozonizer with high yield and efficiency for environment improvement, generation of plasma & laser and EMI EMC are research fields of Enersy & Environment Electromagnetic Laboratory(EEEL) in the school of electrical & electronic engineering of Yeungnam University. On this paper, we would like to introduce the discharge and ozone generation characteristics of ozonizers designed and manufactured by EEEL. After starting research for fluid gas discharge characteristics early in the 1980's, high voltage nozzle(HVN) type ozonizer, neon lamp(Nelamp) type ozonizer, ozone lamp(Olamp) type ozonizer and multi-discharge type ozonizer(MDO) have been investigated since 1990.

  • PDF

The Characteristics of High Ozone Concentration.Yield Multi-discharge Type Ozonizer for Water Environment Improvement (수질환경개선용 고농도·고수율 다중방전형 오존발생기의 특성)

  • ;宋炫直
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.203-203
    • /
    • 1999
  • In this paper, high concentration·yield multi-discharge type ozonizer( MDO ) of new discharge type using superposed silent discharge was designed and manufactured. MDO can be consisted with 3 kind of superposed silent discharge type ozonizer( SDO ) in accordance with power supply method that supplying power, which has 180[°] phase difference, to 3 electrodes and double gap. At the moment discharge characteristics and ozone generation characteristics of each SDO were investigated in accordance with quantify of supplied gas, the number of SDO, and the shapes of each SDO. In result ozone generation characteristics of 17185[ppm] and 783[g/kWh] were obtained, and whorl ozone of 17185[ppm] was in contact with dyeing water waste decolonization characteristics was excellent, so it confirmed that MDO could be used as water environment improvement facility.

Characteristics of Ozonizer with Variation of Vaccum in Internal Electrode (고주파전원형 오존발생기의 방전 캡 변화 특성)

  • 이창호;전병준;이상근;송현직;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.381-385
    • /
    • 2003
  • In this paper, a co-axial type ozonizer varied with discharge gap was designed and manufactured for investigating $\circled1$ discharge characteristics with variation of output voltage power supply, flow rate and gap $\circled2$ ozone generation characteristics with variation of flow rate, gap and discharge power. pure oxygen was used as process gas of the co-axial type ozonizer. In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured. Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode.

  • PDF

The Characteristics of the Discharge Lamp Type Ozonizer using Pulse Power Source for Carnation Productivity Improvement (카네이션 생산성 향상을 위한 펄스 전원을 활용한 방전관형 오존발생기의 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.68-74
    • /
    • 2007
  • For carnation productivity improvement, compact-low cost discharge lamp type ozonizer using pulse power source is designed and manufactured. This paper describes the discharge characteristics and the ozone generation characteristics with variation of the output voltage of pulse power source, the quantity of flowing air and the operating number of ozonizer. The important conclusions are as follows. The discharge voltage and current values are proportional to the output voltage of pulse power source. The ozone concentration and generation are proportional to the output voltage of pulse power source and the number of ozonizer. The maximum value of the ozone concentration and generation of the discharge lamp type ozonizer can be obtained 890[ppm] and 59.7[mg/h] respectively. In the carnation productivity house, when the discharge lamp type ozonizer is used the carnation is good quality in the uniformity of the carnation stalk thickness and increased the productivity through improvement of the air and the soil.

A Study on the Improved Lamp Ttpe Ozonizer(ILO) (개선된 램프형 오존발생기에 관한 연구)

  • Rahman, Fayzur;Lee, Sang-Keun;Chun, Byung-Joon;Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.109-117
    • /
    • 1999
  • In this paper, improved lamp type ownizer( ILO ), which utilizes the superposition of lamp type ownizer( LO ) and surface discharge operation, is designoo and manufactured for the purpose of characteristic improverrent of an LO employoo for installation of environrrent improverrent and good health using Ultraviolet(U.V.) photochemical reactions Irethoc1s. The ownizer consists of 2 types( LO and ILO ), and owne concentration, owne generation and owne yield were investigated in accordance with discharge power and quantity of suwlioo gas. The results of owne concentration, owne generation and owne yield were ILO > LO. So, owne generation characteristics of the lamp type ownizer were improved. At a discharge power of 19[W], owne concentration, owne generation, and owne yield of the ILO are each improvoo than LO 124[%] at the gas flow $1[\ell/min]$ and 143[%] at the gas flow $1[\ell/min]$. The maximum values of owne concentration, owne generation and owne yield were found as 712[ppm], 128[mg/h] and 6750[mg/kWh] respectively.tively.

  • PDF

A Study on Characteristics of Spatial Composition of Japanese Contemporary Detached House - Focused on Family Composition - (가족형태에 따른 일본단독주택 공간구성의 특징 - 일본건축학회 작품선집(作品選集)(건축잡지(建築雜誌) 증간(增刊): 2006-2010)에 수록된 주택을 중심으로 -)

  • Lee, Jeong-Mee
    • Journal of the Korean housing association
    • /
    • v.23 no.6
    • /
    • pp.39-47
    • /
    • 2012
  • In this study, it was analyzed that, the way of securing publicity and privacy in family and type of public space of the Japanese contemporary detached house, by the composition type of family from one person home to four generation family home. Mostly the living room is made as open plan of LDK type. Mostly, the entrance hall is separate with living room. Even if the case of the entrance hall is connected with living room, it is planned to be recognized as entrance hall, by making entrance poach or connecting it with stair hall. In many case, the public space is designed as traditional Japanese style, such as wellhole style space (吹拔け), courtyard, and Japanese style room (和室). The Japanese style room is adjacent to living room, and used as the space of receiving guests. The wellhole style space and courtyard are recognized as the center of the house, and used as buffer space for ensuring privacy of each generation. The most different point between bachelor house and multi generation family house is another LDK space, living room or kitchen for parents' generation is made separately. Particularly there are many case of making separate small kitchen space, therefore it can be known that, the separation of kitchen space is recognized more importantly than that of living room. And there are many case of making separate entrance hall, two houses under one roof. The spatial composition like this can said as rational method of ensuring the privacy of each generation, and using the public space together as necessary.

Installation and Safety Evaluation of Tracking-type Floating PV Generation Structure (추적식 수상 태양광발전 구조물의 시공 및 안전성 평가)

  • Jang, Min-Jun;Kim, Sun-Hee;Lee, Young-Geun;Woo, Sang-Byock;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Pultruded glass fiber reinforced polymeric plastic (PFRP) and FRP member manufactured by sheet molding compound (SMC) have superior mechanical and physical properties compared with those of conventional structural materials. Since FRP has an excellent corrosion-resistance and high specific strength and stiffness, the FRP material may be highly appreciated for the development of floating-type photovoltaic (PV) power generation system. In this paper, advanced floating PV generation system made of PFRP and SMC is designed. In the design, it includes tracking solar altitude by tilting photovoltaic arrays and tracking solar azimuth by spinning structures. Moreover, the results of the finite element analysis (FEA) are presented to confirm stability of entire structure under the external loads. Additionally, installation procedure and mooring systems in the Hap-Cheon Dam are discussed and the measurement of strain under the actual circumstances is conducted for assuring stability of actually installed structures. Finally, by comparison with allowable stress, appropriate safety of structure is confirmed to operate the system.

Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings (주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가)

  • Kim, Deok-Sung;Kim, Beob-Jeon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.35-45
    • /
    • 2017
  • The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was -6.5 to $61.0^{\circ}C$ for mounted modules, $-6.0{\sim}73.9^{\circ}C$ for semi-integrated modules and -5.5 to $88.9^{\circ}C$ for integrated modules. The temperature loss of each installation type was -14.0 to 16.1%, -13.8 to 21.9%, and -13.6 to 28.5%, respectively.

Eddy Current Testing of Weldment by Plus(+) Point Probe (Plus(+) Point Probe를 이용한 용접부 와전류검사)

  • Lee, Hee-Jong;Kim, Yong-Sik;Nam, Mim-Woo;Yoon, Byung-Sik;Kim, Seok-Kon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.6
    • /
    • pp.426-432
    • /
    • 1999
  • A plus-point eddy current test(ECT) probe was developed to examine the defects on the welds of pumps, valves, and pipings which are the major components of the electric power plants, non-destructive evaluation (NDE) techniques for detecting and sizing the flaws were studied adapting this probe. Differential plus-point ECT probe is consists of two "I"-type coils crossed each other and has an advantage having a small influence on the sensitivity by lift-off variation to the conventional types of probe. The specimens with crack-like electro discharge machining(EDM) notches on the weld of type 304 stainless-steel were fabricated in order to evaluate the plus-point ECT probe response to the flaws. NDE techniques to detect and size the flaws and estimate the flaw type were established with this specimens.

  • PDF