• Title/Summary/Keyword: Generating device

Search Result 325, Processing Time 0.026 seconds

Performance Evaluation and Technical Development of Eco-environmental Photovoltaic Leisure Ship with Sail-controlling Device With Respect to Solar-Hybrid Generating System (풍력 Sail 돛 제어장치를 이용한 친환경 태양광 레져보트의 하이브리드 발전시스템 관련 성능평가에 대한 연구)

  • Oh, Kyoung Gun;Moon, Byung Young;Lee, Ki Yeol
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.57-67
    • /
    • 2016
  • As a new technical approach, an attempt was made to realize a photovoltaic system for an eco-environmental leisure ship by simultaneously actuating nine photovoltaic solar panels in association with the application of a sail-controlling system using wind energy. In this approach, the photovoltaic system consisted of a solar module, an inverter, a battery, and the relevant components, while the sail-controlling device was equipped with sail up/down and mast turning systems. The previously mentioned eco-environmental leisure ship utilizes a photovoltaic hybrid system that uses solar and wind energy as renewable energy sources. Furthermore, this research included a performance evaluation of the manufactured prototype, the acquisition of the purposed quantity values, and development of the purposed items. The significant items, including the sail up/down speed (seconds) and mast turning angle (degrees) were evaluated for a performance test. A wind direction sensitivity of 90% and maximum instant charging power of 900 W were also obtained in the process of the performance evaluation. In addition, the maximum sail time was also evaluated in order to acquire the optimum value. The performance evaluation showed that the prototype with a photovoltaic hybrid system was suitable for sailing an eco-environmental leisure ship using solar and wind energy.

The Case Study on the Application of the Standard Method for the Estimation of Range and Degree of Fisheries Damages Caused by Warm Water Drained by Generating Plants (발전소 온배수에 의한 어업피해범위와 정도 및 어업처분을 결정하는 표준화 방안의 적용사례분석)

  • Kang Yong-Joo;Kim Ki-Soo
    • The Journal of Fisheries Business Administration
    • /
    • v.37 no.1 s.70
    • /
    • pp.73-93
    • /
    • 2006
  • This paper tries to apply the standard method for the estimation of range and degree of fisheries damages caused by warm water drained by generating plants to a real situation. The theoretic foundation of the study has been shown in the article published on the journal of fisheries business administration of last year. The paper tries to examine the degree of external appicability of the theoretic model through empirical study. The results of the study are as follows. The model has been found a successful device for the estimation of fisheries damages caused by warm water drained by generating plants. It also shows a possibility to work in any other fisheries damage cases caused by several kinds of public undertaking on coastal areas. The key of the model is the successful derivation of the quantity amount of the critical variation of environmental factors for example, in this case, water thermal variation. Therefore the countinous and appropriate collection of law data on the environmental factors under a viewpoint of statistics is essential to the usefulness of the model.

  • PDF

The Realization of DSP Board for Customer's Power Quality Improvement System by Power-Electronics Device (수용가용 전력전자방식 전력품질 보상장치을 위한 DSP 보드 구현)

  • Lim, Stewart;Lee, Eun-Woong;Kim, Sung-Heon;Sohn, H.K.;Jeong, J.H.;Cho, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.729-732
    • /
    • 2001
  • Digital signal processors(DSP) are widely used in modern power conversion devices, ac motor drives. However, generating pulse-width modulation(PWM) gating signals requires so high sampling rates that most computation resources of the DSP must be devoted to generating them. This paper presents an ASIC realization of 2 channel space-vector PWM(SVPWM). The developed DSP(ECLDSP) board can transmit gating signals to 2 converter/inverter and control them. ECLDSP board is used for control the various kinds of power-quality improvement systems.

  • PDF

Study on Generating Network Data for Pedestrians (보행자를 위한 네트워크 생성에 관한 연구)

  • Kim, Ji-Young;Lee, Jae-Bin;Yu, Ki-Yun
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.7-8
    • /
    • 2010
  • Due to development of wireless environment and portable device, it is possible to use navigation out of car. Specially, pedestrians can freely walk openspace, so there are limits that we use network data of car navigation systems for pedestrian navigation systems. Therefore, in this paper, we proposed the method of generating network data for pedestrians based on the exiting spatial data sets.

  • PDF

Harmonic Motion-based Simulator Design for Multipurpose Sports Simulation

  • Yang, Jeong-Yean
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.163-169
    • /
    • 2015
  • This study proposes a sports simulation device with various harmonics generation. The proposed system is composed of 6 degrees of freedom simulator devices and three types of sports simulation such as walking, snowboard, and jet-ski. In this research, every joint movement is designed with a crank-and-slider mechanism, which is efficient for generating continuous curvature smoothly. Contrary to the conventional spatial simulator with linear actuators, harmonics generation and its spatial combinations become the crucial issue in this research. The harmonic pattern in each joint is modelled for generating smooth curvatures that are also superposed for achieving overall motions. In addition, the targeted motions of sports simulations have different physical factors of periodic gait motion, frictionless surface, and buoyant effects, which are respectively designed by integrating three dimensional graphics information.

A Method for Generating a Plant Model Based on Log Data for Control Level Simulation (제어시뮬레이션을 위한 생산시스템 로그데이터 기반 플랜트 모델 생성 방법)

  • Ko, Minsuk;Cheon, Sang Uk;Park, Sang Chul
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.1
    • /
    • pp.21-27
    • /
    • 2013
  • Presented in the paper is a log data based modeling method for effective construction of a virtual plant model which can be used for the virtual PLC (Programmable Logic Controller) simulation. For the PLC simulation, the corresponding virtual plant, consisting of virtual devices, is required to interact with the input and output symbols of a PLC. In other words, the behavior of a virtual device should be the same as that of the real device. Conventionally, the DEVS (Discrete Event Systems Specifications) formalism has been used to represent the behavior a virtual device. The modeling using DEVS formalism, however, requires in-depth knowledge in the simulation area, as well as the significant amount of time and efforts. One of the key ideas of the proposed method is to generate a plant model based on the log data obtained from the production system. The proposed method is very intuitive, and it can be used to generate the full behavior model of a virtual device. The proposed approach was applied to an AGV (Automated Guided Vehicle).

Comparison of the torque stability of Implant Torque Controllers

  • Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Korean Dental Science
    • /
    • v.2 no.1
    • /
    • pp.19-27
    • /
    • 2009
  • Tightening of the screws in implant restorations should be accurate and precise. If applied torque is too low, screw loosening would be occurred. With too high torque, the screw fracture might take place. Various torque generating devices are developed and employed to apply a proper torque. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; electronic torque controller, torque limiting device, torque indicating device and contra angle torque driver. Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were done with each torque controller. All implant torque controllers have shown slight errors and deviations. The torque liming device exhibited the most accurate data. No significant difference was found among the mean de-torque values of the electronic torque controller, torque indicating device and contra angle torque driver. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

  • PDF

The Influence of The Starting Permanent Magnet on Mo-Load Speed of The Salient Pole Rotor Type Single Phase SRM (영구자석 기동장치가 회전자 돌극형 단상 SRM의 무부하 속도에 미치는 영향)

  • Kim, Jun-Ho;Lee, Eun-Woong;Cho, Hyun-Kil;Lee, Seong-Min;Lee, Hwa-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.73-75
    • /
    • 2002
  • Single phase SRM(switched reluctance motor) is very simple in structure and in driving circuit than three phase SRM. But it can't be started by itself. The prototype of salient pole rotor type single phase SRM was fabricated in former research and the starting device was installed in bottom of the rotor for generating start torque. The starting device is composed of permanent magnet and it is placed the rotor at specific position which is generated positive torque when the prototype is started. Therefore the prototype was started by itself but it is also affected the torque and the speed in operation. On this paper, the influence of the starting device on no-load speed of the prototype was confirmed by measurement of no-load speed according to installation of the starting device or not.

  • PDF

The Effect of Visual Feedback on One-hand Gesture Performance in Vision-based Gesture Recognition System

  • Kim, Jun-Ho;Lim, Ji-Hyoun;Moon, Sung-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.551-556
    • /
    • 2012
  • Objective: This study presents the effect of visual feedback on one-hand gesture performance in vision-based gesture recognition system when people use gestures to control a screen device remotely. Backgroud: gesture interaction receives growing attention because it uses advanced sensor technology and it allows users natural interaction using their own body motion. In generating motion, visual feedback has been to considered critical factor affect speed and accuracy. Method: three types of visual feedback(arrow, star, and animation) were selected and 20 gestures were listed. 12 participants perform each 20 gestures while given 3 types of visual feedback in turn. Results: People made longer hand trace and take longer time to make a gesture when they were given arrow shape feedback than star-shape feedback. The animation type feedback was most preferred. Conclusion: The type of visual feedback showed statistically significant effect on the length of hand trace, elapsed time, and speed of motion in performing a gesture. Application: This study could be applied to any device that needs visual feedback for device control. A big feedback generate shorter length of motion trace, less time, faster than smaller one when people performs gestures to control a device. So the big size of visual feedback would be recommended for a situation requiring fast actions. On the other hand, the smaller visual feedback would be recommended for a situation requiring elaborated actions.

Fabrication of high-frequency therapy device for deep part and temperature distribution characteristic according to electrode condition of RET (심부투열용 고주파 치료기의 제작과 RET 전극조건에 따른 온도 분포 특성)

  • Jung, Jae-Won;Kim, Beong-Ju;Kim, Ki-Seon
    • Journal of Advanced Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.267-271
    • /
    • 2018
  • A high-frequency therapy device with improved output by modifying a high-frequency stimulator was fabricated. The details of the design include generating part design, high-frequency transformer design, large output FET installation, DC voltage input part design and gate input driver design. Based on the real test using the pork meat, the temperature distributions according to the current electric transfer method, penetration depth, electrode diameter size were measured. In the CET method, the penetration depth was 0.5 cm and in the RET method, the penetration depth was 20 cm or more. In addition, it was confirmed that the temperature rise according to the penetration depth in the RET system was substantially constant, and the temperature rise was remarkable as the electrode diameter was small. As a result, it has been confirmed that the high frequency therapy device is highly affected by various conditions of the electrode.