• Title/Summary/Keyword: Generating Efficiency

검색결과 655건 처리시간 0.024초

CAD 형상 데이터를 이용한 비정렬 표면 격자계의 자동 생성 기법 (AUTOMATIC GENERATION OF UNSTRUCTURED SURFACE GRID SYSTEM USING CAD SURFACE DATA)

  • 이봉주;김병수
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.68-73
    • /
    • 2007
  • Computational Fluid Dynamics (CFD) approach is now playing an important role in the engineering process in these days. Generating proper grid system in time for the region of interest is prerequisite for the efficient numerical calculation of flow physics using CFD approach. Grid generation is, however, usually considered as a major obstacle for a routine and successful application of numerical approaches in the engineering process. CFD approach based on the unstructured grid system is gaining popularity due to its simplicity and efficiency for generating grid system compared to the structured grid approaches, especially for complex geometries. In this paper an automated triangular surface grid generation using CAD(Computer Aided Design) surface data is proposed. According to the present method, the CAD surface data imported in the STL(Stereo-lithography) format is processed to identify feature edges defining the topology and geometry of the surface shape first. When the feature edges are identified, node points along the edges are distributed. The initial fronts which connect those feature edge nodes are constructed and then they are advanced along the CAD surface data inward until the surface is fully covered by triangular surface grid cells using Advancing Front Method. It is found that this approach can be implemented in an automated way successfully saving man-hours and reducing human-errors in generating triangular surface grid system.

DEA모형을 이용한 전력회사의 효율성 분석에 관한 연구 (Measuring Efficiency of Global Electricity Companies Using Data Envelopment Analysis Model)

  • 김태웅;조성한
    • 자원ㆍ환경경제연구
    • /
    • 제9권2호
    • /
    • pp.349-371
    • /
    • 2000
  • Data Envelopment Analysis model is a linear programming based technique for measuring the relative performance of organizational units where the presence of multiple inputs and outputs makes comparison difficult. A common measure for relative efficiency is weighted sum of outputs divided by weighted sum of inputs. DEA model allows each unit to adopt a set of weight that shows it in the most favorable light in comparison to the other unit. In this paper, we present the mathematical background and characteristics of DEA model, and give a short case study where we apply the DEA model to evaluate the relative efficiencies of 51 global electricity companies. The technical efficiency and scale efficiency are also to be investigated. Generating capacity and the number of employees are used for input data, and revenue, net profit and electricity sales are used for output data. We find that the companies with 100% relative efficiency are only 9 among 51 electricity companies. And the technical and scale efficiency of KEPCO is 98.7% and 78.89%, respectively. This means that the inefficiency of KEPCO is caused by the scale inefficiency. The analysis shows that the employees should be decreased by 15% at minimum to get the 100% efficiency. The result suggests that KEPCO needs the structural reform to improve the efficiency.

  • PDF

확률적 DEA모형에 의한 품목농협의 효율성 분석 (An Analysis of the Efficiency of Item-based Agricultural Cooperative Using the DEA Model)

  • 이상호
    • 농업생명과학연구
    • /
    • 제45권6호
    • /
    • pp.279-289
    • /
    • 2011
  • 이 논문에서는 부트스트래핑 DEA 모형을 이용하여 품목농협의 효율성 분석 값의 통계적 유의성을 분석하였다. 분석결과, 첫째, 일반적 DEA모형에 의한 기술효율성은 0.878로 추정된 반면, 부트스트래핑 기법을 적용하면 0.804로 추정되었다. 그러나 두 값의 차이는 신뢰구간 범위 내에 있기 때문에 통계적으로는 유의하지 않다. 또한 95% 유의수준하에서 기술효율성의 통계적 신뢰수준은 0.726에서 0.874로 분석되었다. 둘째, 일반적 DEA모형에서 효율적인 품목농협으로 추정된 19개 농협 모두 부트스트래핑 기법을 적용한 경우 비효율적인 것으로 추정되었다. 이는 일반적 DEA모형의 경우 비효율적인 품목농협이 효율적인 것으로 추정될 수 있다는 것이다.

기수지역 선박평형수의 염소 생성 효율에 미치는 전기화학 처리의 영향 (Effect of Electrochemical Treatment on the Chlorine Generation Efficiency of Ballast Water in the Brackish Zone)

  • 최용선;이유기
    • 한국재료학회지
    • /
    • 제29권1호
    • /
    • pp.16-22
    • /
    • 2019
  • Indirect oxidation using chlorine species oxidizing agents is often effective in wastewater treatment using an electrochemical oxidation process. When chlorine ions are contained in the wastewater, oxidizing agents of various chlorine species are produced during electrolysis. In a ballast water management system, it is also used to treat ballast water by electrolyzing seawater to produce a chlorine species oxidizer. However, ballast water in the brackish zone and some wastewater has a low chlorine ion concentration. Therefore, it is necessary to study the chlorine generation current efficiency at various chlorine concentration conditions. In this study, the chlorine generating current efficiency of a boron-doped diamond(BDD) electrode and insoluble electrodes are compared with various chloride ion concentrations. The results of this study show that the current efficiency of the BDD electrode is better than that of the insoluble electrodes. The chlorine generation current efficiency is better in the order of BDD, MMO(mixed metal oxide), $Ti/RuO_2$, and $Ti/IrO_2$ electrodes. In particular, when the concentration of sodium chloride is 10 g/L or less, the current efficiency of the BDD electrode is excellent.

Free-Piston 엔진용 평판형 선형 발전기를 이용한 기동모드 해석 (Starting Mode Analysis of Flat-type Linear Generator for Free-Piston Engine)

  • 김영욱;임재원;정현교
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.966-971
    • /
    • 2008
  • Free-piston engine system is a new type energy converter which uses a linear motion of piston by using linear generator. In free-piston engine system, the piston is not connected to a crank-shaft. The major advantages of free-piston engine system are high efficiency and low mechanical loss from the absence of motion conversion devices. Linear generator of free-piston engine system is used as generator and starting motor. In design step, considering of back-emf and detent force characteristics for generating mode and thrust and control characteristics for starting mode is needed. In this research, generating mode of flat-type linear generator and tubular-type linear generator is analyzed by finite element analysis method and starting mode of both type linear generators is analyzed by using capability curve. Capability curve is plotted from electrical parameters of both type linear generator and motion profile is calculated from mechanical parameters.

A Study On Novel MPPT Method Using Averaging of Voltage Ripple

  • Choi Hae-Ryong;Gho Jae-Surk;Choe Gyu-Ha;Kim Heung-Geun;Shin Woo-Surk
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.692-697
    • /
    • 2001
  • Of two photovoltaic systems such as stand-alone type and utility interactive one, the utility interactive systems are so valuable for power peak-cut particularly in summer season. For the maximum power point tracking(MPPT) by which the generating energy can be maximized, many control methods have been reported up to now. To overcome the disadvantages of the conventional ones, a new MPPT algorithm is proposed which can improve both tracking ability and generating efficiency of photo voltaic system without chopper.

  • PDF

The Interconnection Technology of Small Self-generating System with Distribution Line

  • Park, Kyung-sun;Chiu Hwang
    • 에너지공학
    • /
    • 제8권1호
    • /
    • pp.76-84
    • /
    • 1999
  • The demand of Small Self-generating System (SSS) including Small Cogeneration System (SCS) is constantly increasing with the need of electricity and/or thermal in office, hospital, hotel, and small factory, etc. It is especially recommended to operate SCS in the heat-following mode to maximize the efficiency of generator. In case of the heat-following mode SCS has got to be connected to distribution system so as to send surplus power to the utility or receive the short power from utility. But the interconnection of SSS with distribution system causes a few problems such as the bad power quality, and low security. If SSS is not promptly disconnected after faults occur (Islanding of SSS), it can not only damage equipment of utility and adjacent customers but also endanger life of human due to overvoltage or overcurrent. In this paper it has been deeply discussed if interconnection of engine self-generator/control system satisfies the protective requirement for SSS or not. 500 kW engine generator running in the Jodo island has been used to perform the analysis of interconnection.

  • PDF

JBURG를 이용한 JIT컴파일러 생성에 관한 연구 (A study on the generation of JIT compiler using JBURG)

  • 강경우
    • 정보처리학회논문지A
    • /
    • 제12A권1호
    • /
    • pp.59-64
    • /
    • 2005
  • 본 연구에서는 JBURG를 이용하여 JIT 컴파일러를 생성하는 방법을 제안하였다. JBURG는 Java를 위한 상향식 트리패턴 일치 코드생성기를 생성하는 도구이다. 본 연구에서 제안한 방법은 트리패턴 사이에 관계를 조사함으로 고안되었다. 제안된 방법은 패턴들 사이의 관계를 이용해 분석하고 불필요한 점검을 피할 수 있다는 점에서 기존의 연구결과인 JBURG보다 효율적이다. 필요한 분석들은 코드생성기를 만드는 시간에 수행되기 때문에 실제 코드를 생성해야 하는 컴파일 시간에 효율을 늘일 수 있다.

패킷 통신 네트워크 설계를 위한 시뮬레이티드 애닐링 방법에서 초기해와 후보해 생성방법 (Generating Mechanisms of Initial and Candidate Solutions in Simulated Annealing for Packet Communication Network Design Problems)

  • 임동순;우훈식
    • 한국경영과학회지
    • /
    • 제29권3호
    • /
    • pp.145-155
    • /
    • 2004
  • The design of a communication network has long been a challenging optimization problem. Since the optimal design of a network topology is a well known as a NP-complete problem, many researches have been conducted to obtain near optimal solutions in polynomial time instead of exact optimal solutions. All of these researches suggested diverse heuristic algorithms that can be applied to network design problems. Among these algorithms, a simulated annealing algorithm has been proved to guarantee a good solution for many NP-complete problems. in applying the simulated annealing algorithms to network design problems, generating mechanisms for initial solutions and candidate solutions play an important role in terms of goodness of a solution and efficiency. This study aims at analyzing these mechanisms through experiments, and then suggesting reliable mechanisms.

연료전지 발전 시스템의 직류/교류 변환기 (DC/AC converters for the power generating system using fuel cell)

  • 김용호;권기현;김진수;정용호;최경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1035-1037
    • /
    • 1992
  • Generally, fuel cell has characteristics of low voltage, large current and voltage variation under load change. Therefore, DC output voltage of fuel cell is too low to convert into AC with high efficiency and good performance. For this reason, fuel cell generating system is composed of DC-DC converter and inverter in cascade. This paper used 2-phase boost DC-DC converter to obtain low distortion waveform and reduce input-output current ripple, and discussed inverter which can be operated in independent drive mode and utility line interface drive mode. Then, the change of modes can be achived smoothly.

  • PDF