• 제목/요약/키워드: Generated load

검색결과 1,305건 처리시간 0.023초

유리단 국소의치의 교합하중 적용시 이중금관, 어태치먼트 및 RPI clasp 유지장치에 따라 지대치와 의치상에 미치는 응력 비교 (Comparison of Stress of the Abutment Teeth and Denture Base in Distal Extension Removable Partial Dentures Retained Konus Crown, Precision Attachment and RPI Clasp with the Occlusal Load Application)

  • 전인식;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.331-346
    • /
    • 2006
  • Free-end partial dentures, which are supported by teeth surrounded by dental root membranes and elastic mucous membrane tissues, may cause stress to the abutment teeth due to external force imposed on the denture base, increase the mobility of the abutment teeth, and bring about a change in the periodontal tissue. General retainers used in partial dentures are categorized into clasp, attachment, and Konus crown. Stress imposed on the abutment teeth and mobility of the denture base have relations with the lifetime of a crown and abutment teeth, and have direct relations with the chewing ability. Thus, a need arises to make a comparative analysis of stress of the three direct retainers on the abutment teeth and interpret the mobility of the denture base. This study designed three kinds of removable partial dentures (one kind of attachment partial denture, one kind of Konus crown partial denture, and one kind of clasp partial denture), and fabricated Dentiforms of bilateral partial dentures (Kennedy Class I) with lower left 1st premolar and lower right 1st and 2nd premolars being as the abutment teeth. A strain gauge was installed in the mesial and distal surface of the lowerr left 1st premolar (No. 34) of the fabricated dentiform and in the lower part of the denture base, and installed were a clasp partial denture, an attachment partial denture, and a Konus crown partial denture. Then, the vertical static load of 5kgf and 7.5kgf at the occlusion surface of the lower left No. 6 molar was generated for a total of 20 frequencies of load each using a push-full gauge, and thus a change in the output of the strain gauge was measured. With the respective application of Konus crown, attachment and RPI clasp in the free-end partial denture, surveyed was the distribution of stress imposed on the abutment teeth and the denture base according to the location of occlusion force load so as to come up with the following results. 1. Konus crown and attachment partial dentures generated much stress, and more stress on the abutment teeth than RPI clasp dentures did. Attachment dentures tended to further intensify stress on the abutment teeth than Konus crown dentures did. 2. Attachment dentures and Konus dentures imposed less stress on the denture base than RPI clasp dentures did. There was no stress difference between Attachment and Konus crown dentures. 3. Dentures that were designed with the application of retainers using sturdy linkage methods tended to be less mobile.

  • PDF

신뢰도 기반 활하중모델에 의한 강합성 사장교의 충격계수 평가 (Evaluation of Impact Factor in Composite Cable-Stayed Bridges under Reliability-based Live Load Model)

  • 박재봉;박용명;김동현;이종한
    • 한국강구조학회 논문집
    • /
    • 제25권4호
    • /
    • pp.335-346
    • /
    • 2013
  • AASHTO LRFD 및 도로교한계상태설계기준에서는 신뢰도 기반 활하중 모델로부터 결정된 트럭하중과 차로하중을 동시에 재하하도록 하고 있으며, 트럭하중은 충격계수를 고려하되 차로하중은 충격계수를 적용하지 않도록 규정하고 있다. 본 연구에서는 중앙경간 230m, 400m 및 540m의 멀티케이블 강합성 사장교를 대상으로 트럭하중과 차로하중이 동시에 주행하는 경우에 대해 차량-교량 상호작용 해석을 수행하고 케이블과 보강거더의 충격계수를 평가하였다. 트럭하중은 6-자유도의 차량 모델을 사용하였으며, 차로하중은 일련의 1축 차량이 연행해서 주행하는 것으로 모사하였다. 교량의 감쇠비가 충격계수에 미치는 영향을 평가하였으며, 충격에 영향을 미치는 주요 인자인 노면조도와 주행속도를 해석변수로 고려하였다. 노면조도는 ISO 8608 규정에 근거하여 랜덤 생성하였으며, 차량-교량 상호작용해석 시 노면조도는 트럭하중에만 적용하였다. 한편, 사장교의 충격계수 평가를 위해 실무에서 사용되고 있는 영향선 기법에 의한 충격계수를 동적 상호작용 해석에 의한 결과와 비교하였다.

터널 굴착 발파하중 시간이력 생성 (Generation of blast load time series under tunnelling)

  • 안재광;박두희;신영완;박인준
    • 한국터널지하공간학회 논문집
    • /
    • 제16권1호
    • /
    • pp.51-61
    • /
    • 2014
  • 발파가 인근 시설물에 미치는 영향을 수치적으로 규명하기 위해서는 발파하중 시간이력을 적용한 동적 해석을 수행해야 한다. 발파하중은 실측하기 어렵기에 다양한 참고문헌에서 제시된 경험적 시간이력이 일반적으로 사용된다. 경험적 폭굉압과 시간이력은 다양한 환경변수를 고려하여 보정해야 하지만 이에 대한 가이드라인이 명확하게 제시되지 않아 해석에 어려움이 있다. 본 연구에서는 시험발파를 모사하는 2차원 동적 수치해석을 수행하여 계측기록과 상응하는 경험적 발파하중 시간이력을 도출하였다. 발파로 인한 파쇄영역은 원형으로 가정하여 모델링 하였으며 발파하중을 경계벽에 수직방향으로 재하하였다. 특히, 해석 결과에 지반의 감쇠비는 큰 영향을 미칠 수 있으므로 이를 정확하게 산정해야 한다. 시험적으로 계산된 감쇠식의 기울기는 발파하중의 크기에는 영향을 받지 않으며 하중의 주파수와 지반의 감쇠비에 의해서만 결정되므로 지반 감쇠비는 발파 감쇠식에 상응하도록 결정하였다. 해석 결과, 발파하중은 암반의 파쇄에 소요되는 에너지 손실을 고려하지 않으므로 이를 보정없이 적용할 경우 발파로 인하여 유발되는 진동을 크게 과대예측하므로 이를 감소시켜야 하는 것으로 나타났다.

슬라이딩 거더를 가진 라멘의 온도거동과 구조효율 (Thermal Behavior and Structral Efficiency of Rahmen with Sliding-Girder)

  • 정달영;정창현;임성순
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.1-7
    • /
    • 2020
  • 일반라멘가교의 거동에 영향을 미치는 여러 하중들 중에서 온도하중은 중요한 하중임에도 불구하고 이에 대한 충분한 검토가 부족한 실정이다. 일반라멘가교의 온도하중에 의한 응력을 감소시키기 위해서는 열변형으로 인한 거더의 수평변위는 자유롭고, 발생내력은 최소가 되도록 하여야 한다. 슬라이딩가교는 일반라멘가교와 달리 온도하중으로 인한 축방향 변형을 허용하여 축응력을 감소시키고 휨응력은 전달시키는 구조이다. 본 연구는 슬라이딩거더를 가진 라멘가교의 온도거동과 구조효율성을 일반라멘가교와 비교하여 분석하였다. 분석을 위하여 경간장 10, 20, 30, 40m, 교각높이 2, 4, 6m의 경우에 대하여 일반라멘가교와 슬라이딩가교의 구조해석을 수행하였다. 하중은 연직 고정하중과 축방향 온도하중을 재하하고, 마찰계수는 매끄러운 상태와 윤활상태의 중간인 0.4를 적용하였다. 구조해석결과 슬라이딩가교는 온도하중 증가에 관계없이 경간장 증가에 따라 응력이 증가하며 일반라멘가교는 온도가 증가하거나 경간장이 증가할수록 응력이 증가하였다. 일반라멘가교에 비해 슬라이딩가교의 거더 중앙부 응력은 20에서 50%, 교각 하단부 응력은 50에서 90% 감소하였다. 따라서 온도하중이 작용하는 슬라이딩가교는 축응력이 감소하며 동일 제원의 일반라멘가교와 비교하여 구조효율성을 확보할 수 있다.

배합조건 및 다짐하중에 따른 포러스 콘크리트의 특성에 관한 실험적 연구 (An Experimental Study on the Properties of Porous Concrete according to the Mix Factors and Compaction Load)

  • 임서형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권3호
    • /
    • pp.83-91
    • /
    • 2015
  • 포러스 콘크리트는 시멘트, 물 그리고 굵은골재로 구성되어 있으며, 공기 및 물의 투과 그리고 흡음 등 지구 환경부하를 저감시키기 위해 사용되어 왔다. 그러나 포러스 콘크리트의 물리적, 역학적 성상은 시공시 이루어지는 다짐하중에 의해 변한다. 따라서 본 연구에서는 결합재 종류, 물-결합재비, 목표공극율에 따른 포러스 콘크리트의 물리적, 역학적 성상을 파악하였으며 특히, 다짐하중에 따른 포러스 콘크리트의 공극율, 강도, 투수계수의 물성변화를 파악하였다. 본 연구에서 사용한 골재는 부순자갈 생산과정에서 발생되는 부산물로서 최대크기는 13mm이다. 연구결과, 포러스 콘크리트의 목표 공극율, 투수계수, 압축강도는 공극율과 밀접한 상관성을 지니고 있으며, 공극율은 포러스 콘크리트의 배합설계로 제시할 수 있는 가능성이 있는 것으로 판단되다. 포러스 콘크리트의 압축강도는 팽창재 치환율 5%에서 가장 높게 나타났으며, 실리카 흄 치환율 10%에서 치환하지 않은 콘크리트보다 32% 높게 나타났다. 그리고 다짐하중을 변화시킨 본 연구결과 압축강도는 하중 15kN부터 증가하였고, 공극율은 하중 0.8kN부터, 투수계수는 하중 35kN부터 각각 감소하는 것으로 나타났다.

직렬 아크에 따른 도체의 산화물 증식 및 전압 파형 분석 (The Analysis of Voltage Waveform and Oxidation Growth of Conductor with Series Arc)

  • 최충석;김향곤;김동욱;김동우
    • 전기학회논문지P
    • /
    • 제55권3호
    • /
    • pp.146-152
    • /
    • 2006
  • In order to analyze the characteristics of series arcs that could happen in poor connections of electrical facilities, we made an apparatus which is similar to actual situation. series arcs are generated between copper and copper, copper and bronze, copper and brass, bronze and bronze, and then oxidation growth and voltage waveform were measured. A very small vibration with constant movement is needed to grow oxidation initially, whereas oxidation growth proceeded without a vibration after a certain amount of time. At first, blue white flame was generated initially between copper and copper, and then yellow flame was generated. In case of contact between copper and copper, the length of oxidation growth was about 7.1[mm] in 90[min]. In case of contact between copper and brass, the length of oxidation growth was about 4.3[mm] in 90[min], When bronze is contacted with copper, the lengths of oxidation growth were about 1.4[mm] in 20[min] and 2.7[mm] in 40[min] respectively, and no more oxidation growth was shown after that. In case of contact between brass and brass, the length of oxidation growth was about 1.2[mm] in 90[min], so it was the smallest compared to other cases. When copper is contacted with copper, the current through the load was about 1.6[A] and the power dissipation increased from 19[W] to 31[W]. In case of oxidation growth between copper and brass, the voltage changed from 8.4[V] to 11[V]. However, the voltage drop and the power dissipation between copper and brass were small compared to oxidation growth between copper and copper. When series arcs were generated between bronze and copper, a peak was shown at the beginning of voltage increase, and 40[min] later, oxidation material was not grown any longer. When oxidation growth occurred, voltage waveform showed irregular waveforms with tiny ripples.

골프스윙 3분절 시스템의 Joint Torque의 산출 (A Calculation of Joint Torque for Triple Segmental System in Golf Swing)

  • 임정;황인승
    • 한국운동역학회지
    • /
    • 제16권4호
    • /
    • pp.105-113
    • /
    • 2006
  • The purpose of this study was to analyze the joint torque of triple segmental system in golf driver swing. For this purpose, joint torque were calculated. In order to determine the load on the lumbar region, a triple segmental system was set for wrist, left shoulder and lumbar, torque working on the lumbar region were estimated. For this study, a total of 7 professional golfers were sampled, and then, their driver swings were recorded with two high-speed digital video cameras (180 frames/sec.) to be synthesized into 3-dimensional images and coordinated. Then, Eular's equation was used to produce some kinematic data, which were used to calculate joint torque with Newton's function. All data were calculated using LabVIEW 6.1 graphic program. The results of this study can be summarized as follows; It was found that the joint torque was generated in the direction opposite the target on wrist and shoulder during down swing, while in the direction towards the target on the lumbar region. During impact and release, the torque on the wrist joint was converted from the direction opposite the target to the direction towards the target, while the torque on the lumbar region was generated vice versa. The joints on the club-arm-shoulder were generated in the opposite direction at the beginning of down swing when the torque on the thorax-pelvis began to be generated, and then, the torque on the thorax-pelvis began to lower, while that on the club-arm-shoulder began to increase. Thus, a rapid decrease of the torque on the lumbar region linked to the low trunk acted to increase moment and joint torque on the arm-club region.

복합재료 적층 구조물의 음향방출 특성 연구 (A study on the acoustic emission characteristics of laminated composite structures)

  • 박재성;김광수;이호성
    • Composites Research
    • /
    • 제16권6호
    • /
    • pp.16-22
    • /
    • 2003
  • 음향방출 신호를 측정하면 운용 중에 구조물 내부의 파손 발생이나 진전 시점을 측정할 수 있는 장점이 있다. 본 연구에서는 보강된 복합적층 패널의 압축 시험에서 발생하는 음향방출 신호를 측정하여 누적 신호 분포와 주파수 특성을 분석하였다. 보강 패널의 좌굴 발생과 좌굴 모드의 변환시 음향방출 신호가 발생하였으며, 파손 발생 후 진전시 연속적인 신호가 나타났다. 복합재료 본딩 체결부의 강도 시험에서는 발생하는 음향방출 신호와 파손 형태와의 관계를 분석하였다. 본 연구의 음향방출 신호 분석에 사용된 특성은 시간에 따른 누적 히트(hit) 분포, 주파수 특성과 신호의 크기이다. 본 연구를 통하여 음향방출 신호의 연속적인 발생은 파손의 진전에 따라 나타나는 특성이며, 측정된 음향방출 신호의 주파수 특성을 분석함으로써 적층 복합재료에서 나타나는 파손 모드와의 관계를 유추할 수 있다. 내부 응력크기에 따라 모재균열, 층간분리 또는 디본딩, 섬유파손을 각각 100 근방, 220kHz 근방, 500kHz이상으로 분류할 수 있다.

구름접촉피로시험을 통한 고속철도 레일연마량 분석 (Analysis for Optimal Rail Grinding Amount by Rolling Contact Fatigue Test in High Speed Railway)

  • 성덕룡;장기성;박용걸
    • 한국철도학회논문집
    • /
    • 제15권2호
    • /
    • pp.141-146
    • /
    • 2012
  • 차륜과 레일의 반복적인 구름접촉은 레일 표면결함을 유발하고, 레일 표면결함은 충격하중을 유발하여 소음 진동, 레일파단, 궤도파괴로 이어지고 심할 경우 열차사고(탈선)를 발생할 수 있다. 이러한 레일 표면결함을 제어하기 위한 방법으로 레일연마가 시행되고 있다. 본 연구는 KTX차륜과 UIC레일에서 발생하는 최대 접촉압력을 유한요소해석을 통해 산정하였고, 일반레일 및 열처리레일에 대한 구름접촉피로시험을 수행하여 접촉압력 및 반복횟수에 따른 레일표면 경화층 형성 경향을 분석하였으며, 누적통과톤수에 따라 고속철도 레일에서 발생하는 표면 경화층을 제거하여 건전한 레일표면을 유지하기 위해 0.2mm/2천만톤의 적정 레일연마량을 제안하였다.

내린천수계 비점오염원 오염물질 유출량조사 (A Study on Water Quality and Amount of Flowing at Nonpoint Source of Nairin Stream)

  • 허인량;박성빈;오흥석;김영진
    • 한국환경보건학회지
    • /
    • 제35권3호
    • /
    • pp.220-225
    • /
    • 2009
  • This study evaluates the water quality of the river near the alpine farmland in the upper Naerin stream, which is a typical stream of the upper Bukhan River with muddy water generation, by the flow examination, it aims to estimate the characteristics of nonpoint sources flowing out from the investigated area and figure out effective methods to reduce them. According to the result of water quality examination, the average BOD of the area not affected by the cultivated land among the areas of the upper Naerin River was 0.47mg/l, and total phosphorous was 0.007mg/l; thus, it maintained the cleanliness level of Ia. The average BOD of the area with the alpine farmland was 0.52mg/l, which was similar to the one of the non-cultivated land. But total phosphorous concentration was 0.023mg/l, which was more than three times higher than the area belonging to level II due to the effect of fertilizer ingredients discharged from the cultivated land. About the loadings of the investigated area generated from each of the pollution sources, BOD was 878.5kg/day and total phosphorous was 79.7kg/day. Moreover, for the load density, BOD was $2.22kg/day.km^2$ and total phosphorous was shown as $0.20kg/day.km^2$. Regarding the rates generated from nonpoint sources like land among the loadings per pollution sources, BOD was 54%, total nitrogen was 91%, and total phosphorous was 73.4%. Therefore, it was shown that most of the nutrients were produced from the nonpoint sources. The level of BOD runoff loading in the Jaun River area, where nonpoint sources were mainly generated, was 37.1kg/day and total phosphorous was 1.33kg/day. The flow rates to the generated amount were estimated as 10.5% and 4.7% each.