• 제목/요약/키워드: Generated load

검색결과 1,305건 처리시간 0.025초

Evaluation of horizontal-axis-three-blade wind turbines' behavior under different tornado wind fields

  • Mohamed AbuGazia;Ashraf El Damatty;Kaoshan Dai;Wensheng Lu;Nima Ezami
    • Wind and Structures
    • /
    • 제37권6호
    • /
    • pp.413-423
    • /
    • 2023
  • Wind turbines are usually steel hollow structures that can be vulnerable to dramatic failures due to high-intensity wind (HIW) events, which are classified as a category of localized windstorms that includes tornadoes and downbursts. Analyzing Wind Turbines (WT) under tornadoes is a challenging-to-achieve task because tornadoes are much more complicated wind fields compared with the synoptic boundary layer wind fields, considering that the tornado's 3-D velocity components vary largely in space. As a result, the supporting tower of the wind turbine and the blades will experience different velocities depending on the location of the event. Wind farms also extend over a large area so that the probability of a localized windstorm event impacting one or more towers is relatively high. Therefore, the built-in-house numerical code "HIW-WT" has been developed to predict the straining actions on the blades considering the variability of the tornado's location and the blades' pitch angle. The developed HIWWT numerical model incorporates different wind fields that were generated from developed CFD models. The developed numerical model was applied on an actual wind turbine under three different tornadoes that have different tornadic structure. It is found that F2 tornado wind fields present significant hazard for the wind turbine blades and have to be taken into account if the hazardous impact of this type of unexpected load is to be avoided.

단자유도 해석모델을 활용한 응답스펙트럼과 지진취약도 곡선과의 관계에 대한 연구 (A Study on the Relationship between Response Spectrum and Seismic Fragility Using Single Degree of Freedom System)

  • 박상기;조정래;조창백;이진혁;김동찬
    • 한국지진공학회논문집
    • /
    • 제27권6호
    • /
    • pp.245-252
    • /
    • 2023
  • In general, the design response spectrum in seismic design codes is based on the mean-plus-one-standard deviation response spectrum to secure high safety. In this study, response spectrum analysis was performed using seismic wave records adopted in domestic horizontal design spectrum development studies, while three response spectra were calculated by combining the mean and standard deviation of the spectra. Seismic wave spectral matching generated seismic wave sets matching each response spectrum. Then, seismic fragility was performed by setting three damage levels using a single-degree-of-freedom system. A correlation analysis was performed using a comparative analysis of the change in the response spectrum and the seismic fragility concerning the three response spectra. Finally, in the case of the response spectrum considering the mean and standard deviation, like the design response spectrum, the earthquake load was relatively high, indicating that conservative design or high safety can be secured.

무선전력전송의 송전 공진코일에서 발생하는 방전현상 연구 (Study on Discharge Phenomenon Occurring in Transmitting Resonance Coil of Wireless Power Transmission)

  • 이기범
    • 한국전자통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.355-360
    • /
    • 2024
  • 본 논문에서는 4-코일 방식의 자기공진 무선전력전송 시스템을 구현하는 데 있어서, 송전 공진코일의 끝단에서 발생하는 선간 방전현상을 연구하였다. 자기공진 무선전력전송은 급전코일, 송전 공진코일, 수전 공진코일, 부하코일로 구성되어 있다. 여기서 송전 공진코일은 급전코일에서 발생한 자기장을 증폭하여 전방의 수전 공진코일로 전달하는 역할을 한다. 큰 전력을 전송하기 위하여 급전코일에 높은 전류를 흘려주면 송전 공진코일 끝단에 높은 전압이 유기되어 선간 방전현상이 일어나게 된다. 선간 방전현상은 송전기 케이스를 손상시키게 되고, 송전기를 사용할 수 없는 상태로 만든다. 따라서 이러한 선간 방전현상을 제거하기 위하여, 선간 방전을 일으키는 송전 공진코일에 유기되는 전압을 분석하고, 해결 방안을 제시하였다.

영향선을 이용한 강상판 교량의 구스 아스팔트 포장에 대한 근사해석 연구 (A Study on Approximate Analysis of Steel Deck Bridges with Guss Asphalt Using Influence Line)

  • 서기홍;가훈;공민식;임성순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.127-135
    • /
    • 2006
  • 본 연구는 포장재의 높은 온도로 인해 발생하는 교량의 구조거동을 해석대상모델로 선택하여 열효과로 인한 변형이론를 정리하고 시공단계별 포장에 따른 교좌장치의 열 효과를 고려한 근사법의 제시를 연구목적으로 한다. 일반적으로 열영향은 대상 구조물의 형상, 크기 및 경계조건과 시간에 종속되는 대표적인 초기응력문제이다. 본 연구는 열영향을 시간에 독립된 초기응력문제로 가정하고 이를 등가의 초기하중으로 변환하여 이동하중처럼 재하함으로서 교좌장치에 발생하는 반력 및 변위에 대한 영향선 해석을 수행하였다. 임의로 선정한 연속된 포장구간에 대해 계산된 영향선을 이용하여 교좌장치들에 발생하는 열영향을 최소화하는 최적의 시공단계를 결정하였다.

스마트 플랜트를 위한 빅데이터 및 AutoML 플랫폼 개발 (Development of Big Data and AutoML Platforms for Smart Plants)

  • 강진영;정병석
    • 한국빅데이터학회지
    • /
    • 제8권2호
    • /
    • pp.83-95
    • /
    • 2023
  • 스마트 플랜트 발전에 있어서 빅데이터 분석과 인공지능은 중요한 역할을 한다. 본 연구에서는 플랜트 데이터를 위한 빅데이터 플랫폼과 인공지능 기반 플랜트 유지 관리를 위한 'AutoML 플랫폼'을 개발하였다. 빅데이터 플랫폼은 하둡, 스파크, 카프카를 활용하여 플랜트에서 발생하는 대용량의 데이터를 수집, 처리, 적재하는 플랫폼이다. AutoML 플랫폼은 설비의 예지보전 및 공정 최적화를 위한 예측 모델을 구축하는 머신러닝 자동화 시스템이다. 위 플랫폼은 기존 플랜트 운영 정보 시스템과의 호환성을 고려하여 데이터 파이프라인을 구성하고, 웹 기반 GUI를 통해 작업자의 접근성과 편의성을 향상하였으며, 데이터 처리와 학습 알고리즘에 사용자 정의 모듈을 탑재하는 기능을 통해 유연성을 증대시켰다. 본 논문은 국내 정유회사의 특정 공정을 대상으로 플랫폼을 실제 운영해보았고, 이를 통해 스마트 플랜트를 위한 효과적인 데이터 활용 플랫폼 사례를 제시한다.

Mechanical performance analysis of an electromagnetic friction pendulum system based on Maxwell's principle

  • Mao Weikang;Li Xiaodong;Chen Enliang
    • Earthquakes and Structures
    • /
    • 제27권2호
    • /
    • pp.143-154
    • /
    • 2024
  • Friction pendulums typically suffer from poor uplift-restraining. To improve the uplift-restraining and enhance the energy dissipation capacity, this article proposed a composite isolation device based on electromagnetic forces. The device was constructed based on a remote control system to achieve semi-active control of the composite isolation device. This article introduces the theory and design of an electromagnetic chuck-friction pendulum system (ECFPS) and derives the theoretical equation for the ECFPS based on Maxwell's electromagnetic attraction equation to construct the proposed model. By conducting 1:3 scale tests on the electromagnetic device, the gaps between the practical, theoretical, and simulation results were analyzed, and the accuracy and effectiveness of the theoretical equation for the ECFPS were investigated. The hysteresis and uplift-restraining performance of ECFPS were analyzed by adjusting the displacement amplitude, vertical load, and input current of the simulation model. The data obtained from the scale test were consistent with the theoretical and simulated data. Notably, the hysteresis area of the ECFPS was 35.11% larger than that of a conventional friction pendulum. Lastly, a six-story planar frame structure was established through SAP2000 for a time history analysis. The isolation performances of ECFPS and FPS were compared. The results revealed that, under horizontal seismic action, the horizontal seismic response of the bottom layer of the ECFPS isolation structure is greater than that of the FPS, the horizontal vibration response of the top layer of the ECFPS isolation structure is smaller than that of the FPS, and the axial force at the bottom of the columns of the ECFPS isolation structure is smaller than that of the FPS isolation structure. Therefore, the reliable uplift-restraining performance is facilitated by the electromagnetic force generated by the device.

적대적 생성 신경망 기반 비공기압 타이어 디자인 시스템 (Non-pneumatic Tire Design System based on Generative Adversarial Networks)

  • 성주용;이현준;이성철
    • Journal of Platform Technology
    • /
    • 제11권6호
    • /
    • pp.34-46
    • /
    • 2023
  • 자동차 타이어의 휠과 트레드 사이에 탄성중합체 또는 다각형의 스포크를 채우는 방식으로 제작하는 비공기압 타이어는 자동차 관련 학계 및 항공우주 업계의 중요한 연구 주제가 되고 있다. 본 연구에서는 생성형 적대 신경망을 기반으로 비공기압 타이어 디자인을 생성하는 시스템 개발했다. 특히 비공기압 타이어의 종류와 사용 환경, 제작 방식, 공기압 타이어와의 차이점 그리고 스포크 디자인에 따른 하중 전달의 변화 등 디자인에 영향을 미칠만한 변수들에 대한 조사를 실시했다. 이 연구는 OpenCV를 통해 다양한 스포크 형태의 이미지를 만들고, projected GANs에 학습시켜 비공기압 타이어 디자인에 사용될 스포크를 생성했다. 디자인된 비공기압 타이어는 사용 가능 및 불가능으로 레이블링하고, 이를 Vision Transformer 이미지 분류 AI 모델에 학습시켜 분류하도록 하였다. 최종적으로 분류 모델의 평가를 통해 0에 가까운 loss의 수렴, 99%의 정확도를 확인했다. 차후 도형 및 스포크 이미지와 알고리즘을 이용한 디자인이 아닌, 완전 자동화 시스템의 개발과 더 나아가 3D의 물리적 해석 없이 사용 가능한 디자인을 생성하는 것을 목표로 한다.

  • PDF

실제 운전조건을 고려한 전기자동차 베어링의 전기적 손상 평가 (Evaluation of Electrical Damage to Electric-vehicle Bearings under Actual Operating Conditions )

  • 박정수;김정식;이승표
    • Tribology and Lubricants
    • /
    • 제40권4호
    • /
    • pp.111-117
    • /
    • 2024
  • Due to global CO2 emission reductions and fuel efficiency regulations, the trend toward transitioning from internal combustion engine vehicles to electric vehicles (EVs) has accelerated. Consequently, the problem of EV failures has become a focal point of active research. The parasitic capacitance generated during motor-shaft rotation induces voltage that deteriorates the raceway and ball surfaces of bearings, causing electrical damage in EVs. Despite numerous attempts to address this issue, most studies have been conducted under high viscosity lubricant and low load conditions. However, due to factors such as high-speed operation, rapid acceleration and deceleration, motor heating, and motor system-decelerator integration, current EV applications have shown diminished stability in lubrication films of motor bearings, thereby leveraging the investigation to address the risk of electrical damage. This study investigates the electrical damage to rolling bearing elements in EV motor drive systems. The experimental analysis focuses on the effects of electric currents and operational loads on bearing integrity. A test rig is designed to generate high-rate voltage specific to a motor system's parasitic capacitance, and bearing samples are exposed to these currents for specified durations. Component evaluation involves visual inspections and vibration measurements. In addition, a predictive model for electrical failure is developed based on accumulated data, which demonstrates the ability to predict the likelihood of electrical failure relative to the duration and intensity of current exposure. This in turn reduces uncertainties in practical applications regarding electrical erosion modes.

지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가 (Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제11권1호
    • /
    • pp.135-147
    • /
    • 2015
  • 최근 지하공동구(Underground Common Utility Tunnels)는 도시민이 일상생활을 영위하는데 필요한 전기, 통신, 상수도, 도시 가스, 하수도뿐만 아니라 냉난방시설, 진공 집진관, 정보처리케이블 등의 시설물을 2종 이상 공동으로 수용하기 위한 지하시설물로서 국가의 중추기능을 담당하는 시설이지만, 화재 사고시 신속한 대처가 힘들고 각종 케이블 연소시 발생하는 유독가스 및 연기에 의해 공동구 내에 진입하여 진압하기가 힘들다. 따라서 화재발생시 막대한 재산피해 및 통신두절 등 국가의 중추신경이 마비됨은 물론 시민불편사항을 초래하게 된다. 따라서 본 논문은 지금까지 발생 되어온 국내,외 공동구 화재사례에서 화재발생의 주요원인으로 전기공사로 인한 합선 및 가연성케이블에 의한 열화접촉으로 화재가 발생하는 것이 대다수를 차지하고 있음에 착안하여 실제 공동구 모형을 제작하고 화재를 재현함으로서 과학적으로 화재의 성상을 분석하는데 그 목적이 있다. 화재실험은 지하공동구 내에 정온식 감지선형 감지기(Line type fixed temperature detector), 방화문(Fire door), 연결살수설비(Connection deluge set), 및 환기설비를 설치하고, 송 배전케이블은 일정구간 내화(Fireproof)도료로 도장하며, 난방관은 내화 피복된 상태에서 실험하였다. 그 결과 Type II의 경우 최고온도가 $932^{\circ}C$로 측정되었고, 일정한 온도에서 정온식감지선형감지기가 화재위치를 정확하게 수신반에 표시되었다. 그리고 Type III의 경우인 송 배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복(Fireproof covered)된 난방관은 약 30분 정도의 내화성능이 있는 것으로 나타났다. 또한 화재뮬레이션 결과는 실물화재시험시의 화재하중(Fire load)을 입력하여 실시한 결과로서 최고온도가 $943^{\circ}C$로 실물화재실험시의 $932^{\circ}C$와 거의 일치 하였다. 따라서 공동구 화재하중만으로 화재시뮬레이션을 실시하여 화재성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻은 열방출률(Heat release rate), 연기층의 높이, 산소(O2), 일산화탄소(CO), 이산화탄소(CO2)의 농도 등의 결과 값들은 실제 화재실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 향후 본 연구에서 구축한 국내 지하공동구 화재사고에 대한 실험자료 및 매년 지속적으로 화재사례들을 분석하여 축적하고 법 규정 및 관리 메뉴얼 등을 보완함으로써 국내 지하공동구 화재사고에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있을 것이며, 효과적이고 체계적으로 지하공동구의 신설 및 유지 관리 보수에 기여할 것으로 기대된다.

다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향 (The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns)

  • 라일라 아부카보스;박재억;이원섭
    • 대한치과보철학회지
    • /
    • 제60권2호
    • /
    • pp.135-142
    • /
    • 2022
  • 목적: 이번 연구의 목적은 단일구조 지르코니아(monolithic zirconia) 크라운의 서로 다른 부위에서, 감소된 지르코니아의 두께가 파절 저항성에 미치는 복합적인 영향을 평가하기 위한 것이다. 재료 및 방법: 실험을 위해 7개의 니켈-크롬 다이를 제작하였다. 다이는 하악 제 1대구치를 치아 형성한 지대치 3D 모델을 바탕으로 제작되었다. 지대치는 1.5 mm 교합면 삭제를 시행하였고, 변연은 1.0 mm의 deep chamfer로 형성하였다. 이 지대치 형태를 바탕으로 지르코니아 블록(Luxen Zirconia)를 사용하여, 교합면 두께는 0.3 mm, 0.5 mm, 1.5 mm, 축면 두께는 0.3 mm, 0.5 mm, 1.0 mm로 설정한 63개의 지르코니아 크라운을 제작하였다. 이 크라운은 니켈 크롬 다이에 레진 시멘트를 이용하여 접착하였다. 그 다음, electronic universal testing machine을 사용하여 크라운이 파절될 때까지 load-to fracture 시험을 진행하였다. 이후 scanning electron microscope (SEM)를 사용하여 크라운의 파절 형태를 관찰하였다. 통계 분석을 위해 Two-way ANOVA 방법을 사용하였고, 이에 대하여 Tuckey HSD test로 사후 검정을 시행하였다(P < .05). 결과: 모든 지르코니아 크라운의 평균 파절 저항 값은 구치부의 평균 저작력보다 큰 값을 나타냈다. 또한 Two-way ANOVA 결과, 지르코니아 크라운의 교합면 두께와 축면 두께는 파절 저항에 통계적으로 유의한 영향을 미치는 것으로 나타났다(P < .05). 그러나, 지르코니아의 축면 두께가 0.5 mm 이상일 때, 파절 저항에 미치는 영향은 통계적으로 유의한 차이를 보이지 않았다. 나타난 파괴 양상은 균열의 전파 양상에 따라 크라운의 부분 파절 또는 완전 파절로 나타났다. 결론: 이번 연구의 한계 내에서, 극도로 감소된 두께를 가진 CAD-CAM 단일구조 지르코니아 크라운은 구치부 교합력을 견딜 수 있는 적절한 파절 저항을 보였다. 또한, 지르코니아 크라운의 교합면 두께와 축면 두께는 파절 저항에 유의미한 영향을 나타냈으며 복합적인 결과를 보였다.