• 제목/요약/키워드: Generated load

검색결과 1,305건 처리시간 0.025초

공명기를 이용한 소형위성발사체 탑재부의 음향하중 저감 (Acoustic Load Reduction in the Payload of Small Launch Vehicle by using Resonators)

  • 서상현;정호경;박순홍;장영순;이영무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.234-237
    • /
    • 2007
  • To protect a satellite and electronic equipment from the acoustic load generated by rocket propulsion system, many launch vehicle use acoustic blanket. Acoustic load is main source of random vibration working on the payload. Most high frequency region of the acoustic loads is reduced by payload fairing skins and acoustic blanket, but low frequency region is not. In order to reduce acoustic load of low frequency region, we designed array resonator panel which was made of composite materials. Insertion loss capacity of the payload fairing with acoustic blanket was verified from PLF acoustic test in the acoustic chamber.

  • PDF

통증 완화 치료기용 인체 부하 변동에 따른 피드백 제어가 가능한 고주파 회로 설계 (High Frequency Circuit Design using Feedback Control with Body Load Fluctuation for Pain Relief Therapy)

  • 박철원;원철희
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.45-49
    • /
    • 2013
  • High frequency system has been used for the purpose of skin care and obesity treatment, by high-frequency energy is applied to the human body generates deep heat. Conventional high frequency system could not selection control by depending on the body load fluctuations. Such as burns and side effects have been reported by system instability and then therapeutic effect is insufficient. During treatment, objective information about the status of the patient was no. Because of treatment methods are subjective, and so tailored treatments were impossible. In this paper, high frequency medical system with sinusoidal frequency characteristics without distortion of the Push pull switching scheme for pain relief therapy was designed. And control circuit that was designed by feedback using the output changes according to the body-load fluctuation. Last, power circuit for efficient control the heat generated from the hardware was proposed.

5상 5kW 표면부착형 영구자석 동기발전기 운전특성 (An Operating Characteristics of Surface Permanent Magnetic Synchronous Generator for 5-Phase 5kW)

  • 정형우;김민회;송현직;김동희
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.9-16
    • /
    • 2013
  • This paper presents an operating characteristics of the 5-phase 5kW with developed the surface permanent magnetic synchronous generato (SPMSG) in order to make a study of a polyphase ac motors keeping hold of more advantages. There are shown a amplitude and waveform of the generated electromotive force, in FFT analysis of harmonics, within output voltages, and reviewing a experiment results in no-load test, resistive load, and inductive load using 5-phase induction motor by variable output frequency. The operating characteristics of the developed manufacturing generator include voltage regulation, efficiency, power factor, THD, and so on at rated load.

Finite element generalized tooth contact analysis of double circular arc helical gears

  • Qu, Wentao;Peng, Xiongqi;Zhao, Ning;Guo, Hui
    • Structural Engineering and Mechanics
    • /
    • 제43권4호
    • /
    • pp.439-448
    • /
    • 2012
  • This paper investigates the load sharing of double circular arc helical gears considering the influence of assembly errors. Based on a load sharing formulae, a three-dimensional finite element tooth contact analysis (TCA) is implemented with commercial software package ANSYS. The finite element grid for the double circular arc gear contact model is automatically generated by using the APDL (ANSYS Parameter Design Language) embedded in ANSYS. The realistic rotation of gears is achieved by using a coupling degree-of-freedom method. Numerical simulations are carried out to exemplify the proposed approach. The distribution of contact stress and bending stress under specific loading conditions are computed and compared with those obtained from Hertz contact theory and empirical formulae to demonstrate the efficiency of the proposed load sharing calculation formulae and TCA approach.

Energy Performance and Improvement in University Library - Concentrated on 'K'University Library located in Seojong City -

  • Roh, Ji Woong
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.47-52
    • /
    • 2014
  • The problem of energy consumption is more serious in university buildings than primary, middle and high school buildings. Because university buildings have generally heating and cooling systems, and various incidental facilities. In university, the library is one of the building that many people use and the most energy is spent. So, investigation on energy saving is very important and urgent. This study aims finally to present the guideline for low-energy design of University library by aiding a designer to select best solution in the side of energy-saving. In this paper, composition of space, utilization schedule and performance of construction materials are grasped, some primary factors that effect to energy saving are analyzed by energy simulation. The result of this study is as follows; First, the subject library has more cooling load than heating load because of cooling load generated during middle season. Second, green roofs is the most effective to heating load saving, but not to cooling energy. Third, outdoor air cooling is the most effective to cooling energy saving among the investigated strategies included in this study.

저압 시스템에서 비선형 부하의 사용에 따른 전력품질 해석 (Analysis of power quality using non-linear load at low voltage system)

  • 김종겸;이은웅;손홍관;김일중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.660-662
    • /
    • 2001
  • This paper describes the problems generated with the use of PWM ASDs with induction motors. The major effect of harmonic voltages and currents in induction motors is increased the heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency and developed the torque. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we set up simple load system and measured the voltage and current. Measurement results show that additional operation of induction motor at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF

Z-map 기반 NC 검증모델을 이용한 칩부하 제어 (Chip Load Control Using A NC Verification Model Based on Z-Map)

  • 백대균;고태조;김희술
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.801-805
    • /
    • 2000
  • This paper presents a new method of tool path optimization. A NC verification model based Z-map was utilized to obtain chip load in feed per tooth. This developed software can regenerate a NC program from cutting condition and the NC program that was generated in CAM. The regenerated NC program has not only all same data of the ex-NC program but also the new feed rates in every block. The new NC data can reduce the cutting time and manufacture precision dies with the same chip load in feed per tooth. This method can also prevent tool chipping and make constant tool wear. This paper considered the effects of acceleration and deceleration in feed rate change.

  • PDF

원추형 벤튜리 유량계에 관한 동하중 평가 (The Evaluation of Dynamic Load for the Cone Type Venturi Flow meter)

  • 김중권;장경영;조남오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.140-144
    • /
    • 1997
  • Although the cone type venturi flow meter is superior to another differential pressure type flow meter in precision, the venturi is installed at the pipe as an L beam, so that the dynamic load due to drag force and flow-induced force is generated in the flow meter. In this paper we propose a methodology to evaluate this dynamic load directly by using stain-gages attached on the venturi and we discuss about the dynamic characteristics on the basis of flow-induced vibration theory.

  • PDF

A NEW INSTANTANEOUS VOLTAGE COMPENSATOR WITH FUNCTION OF ACTIVE POWER FILTERING

  • Lee, Seung-Yo;Lee, Jeong-Min;Lee, Sang-Yong;Mok, Hyung-Soo;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.780-784
    • /
    • 1998
  • A novel active input unbalance voltage compensator with harmonic current compensating capability is proposed and the operating principle of the proposed system is presented in the 3-phase power system. The proposed system performs both the voltage regulation of the load and the compensation of the harmonic currents generated due to nonlinear load such as diode rectifier. The system to compensate unbalanced voltage and hramonic currents is composed of a 3-phase voltage source inverter, LC filter, series transformer and passive devices at the load side of the line. The compensating voltage to regulate the load voltage and to remove the harmonic current components is transmitted to the line by the series transformer. The validity of the line by the series transformer. The validity of the proposed system is proved by the results of computer simulation.

  • PDF

일정 부하 수축 시 수집한 표면근전도 신호에서 검출한 15개 특성 변수들의 노화에 따른 차이 (Age-related difference of the 15 Characteristics Variables in Surface EMG Signals Generated Under Constant Load Contraction)

  • 이진;유인규;김세동
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1674-1680
    • /
    • 2008
  • The objective of this study is to compare age-related differences of 15 characteristic variables estimated from SEMG signals, which were obtained from the old group(62 subjects) and young group(72 subjects). The SEMG signals were recorded from biceps brachii muscle under sustained isometric elbow flexion contraction with constant load(4kg dumbbell) during 30 seconds. Ten time domain (ARV, RMS, MSA, MTA, ZC, MSF, MTF, MSD, MTD, MSS) and five frequency domain(MNF, MDF, $f_{max}$, $P_{max}$, $P_{to}$) variables were extracted from the SEMG signals and then statistically analyzed, respectively. The findings of the analysis indicate significant age-related differences in the SEMG signal during constant load contraction.