• Title/Summary/Keyword: General ventilation

Search Result 241, Processing Time 0.025 seconds

Development of the Hospital Foodservice Facility Evaluation tools based on the General HACCP-based Sanitation Standards and Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설ㆍ설비 위생관리 점검도구 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.3
    • /
    • pp.339-353
    • /
    • 2003
  • The rapid increase in food borne illness outbreaks in Korea has been one of the major threats to the Nation's Health. Foodservice establishments have been identified as the major place for these outbreaks, mainly due to the lack of sanitary management and sanitary facility management practices. The purposes of the study were to develop hospital foodservice facility evaluation tools, based on the general HACCP-based standards and guidelines, for hospital food service establishments, to ensure the safety of these foodservices and to reduce the risk of food home illness. The scope of this study included: 1) an assessment of the current foodservice sanitation practices and managements for 6 general hospitals, with more than 400 beds, and 3 general hospitals, with less than 400 beds; 2) the development of foodservice establishments sanitation evaluation tools and sanitation standards, based on the HACCP system. The survey data showed varied results between the hospitals surveyed. Most of the hospital foodservice operations had many problems with ventilation and the plumbing. The total dimensional mean scores for the hospitals with more than 400 beds and less than 400 beds were 31.5 and 27.0, respectively. The highest dimension scores were for the water supply facility and lighting, with the lowest for insect and rodent control and toxic materials management. The levels of the mean scores were very low, especially for the general hospitals with less than 400 beds. These low mean scores may have arisen from critical problems within the hospital foodservice operations. The most needed facility management items for improvement were: storage shelf should be spaced 6 inches from the floor and walls, the use of three compartment sinks, utility sinks and cleaning facilities, with a floor drain for cleaning mops or liquid wastes, a ventilation hood designed to prevent dripping onto food, cooking facilities should be disassembled for washing and sanitizing, a separated hand washing sink and a sanitized food board for each area should be provided, all toxic material must have warning labels attached, and be stored in an area away from food preparation under padlock. The evaluation tool consisted of 14 dimensions, with 65 check-off items. The results of this study will provide basic facilities' guidelines to regulators, or foodservice industry personnel, wishing to build, or expend, and establish an efficient flow of food. As a result, food borne illnesses will be effectively prevented, and the Nation's health will be promoted for the development of their own sanitation standards, with a checklist for the safe production of foods.

DENTAL TREATMENT OF A PATIENT WITH SWYER JAMES UNDER GENERAL ANESTHESIA: A CASE REPORT (Swyer James syndrome환아의 전신마취 하 치아우식 치료: 증례보고)

  • Sung, Young Jae;Song, Ji Soo;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Shin, Teo Jeon
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.15 no.1
    • /
    • pp.60-64
    • /
    • 2019
  • Swyer-James syndrome (SJS), also known as Swyer-James-MacLeod syndrome and unilateral hyperlucent lung syndrome, is rare acquired pulmonary disorder develops secondary to infectious etiologies in early childhood. Viral respiratory infection such as adenoviruses or Mycoplasma pneumoniae in infancy or early childhood rarely cause Swyer-James syndrome. It is generally characterized on radiographs by a unilateral small lung with hyperlucency and air trapping on expiration. In many cases unaffected lung tissue functions normally, compensating for affected lung portion. Preoperative assessment is needed to determinate individual's pulmonary function. A 4-year-old boy with Swyer-James syndrome visited Seoul National University Dental Hospital Department of pediatric dentistry for caries treatment. Clinical and radiographic examinations revealed multiple carious lesions on deciduous teeth. Considering patient's underling disease, age, and level of cooperation, dental treatment under general anesthesia was scheduled. Dental treatment was done with composite resin and stainless-steel crown. Since ventilation of Swyer-James syndrome patients was diminished because of airway obstruction, close monitoring of ventilation is necessary during dental treatment. Considering pulmonary pathology, general anesthesia rather than sedation is recommended when special behavior management is required for dental treatment. Swyer-James syndrome patients can tolerate general anesthesia and surgery well, according to several reports.

Concentrations and environmental influences of airborne fungi at university laboratories, hospital diagnostic laboratories (대학실험실과 병원진단검사실에서의 부유진균 농도와 환경영향인자)

  • Hwang, Sung-Ho;Park, Dong-Uk;Ha, Kwon-Chul;Park, Hyun-Hee;Joo, Se-Ik;Yoon, Chung-Sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.256-262
    • /
    • 2010
  • This study evaluated the airborne concentrations of fungi in university laboratories, hospital diagnostic laboratories in Seoul. The incubated fungi was identified by lactophenol cotton blue (LPCB) staining method. Variables such as types of ventilation, temperature and relative humidity were investigated to explain laboratory airborne fungal concentrations. A total of 97 air samples were collected from 10 facilities in two institutions. Aspergilus spp., including Aspergilus niger, Aspergillius flavos and Penicillium spp. were found as predominant species. Airborne fungal concentrations ranged from not detected (ND) to 1,890 CFU/$m^3$. Airborne fungal concentrations were high in general-ventilated facilities and in laboratories where relative humidity ( > 60 %) were high ( p < 0.001). Therefore, we suggest that relative humidity should be maintained to properly reduce the concentration of fungal in university and hospital laboratories.

Measures to Prevent Recurrence through the Analysis of an Explosion Case at Ammonia Refrigeration Facilities (암모니아 냉동시설의 폭발사례 분석을 통한 재발방지대책)

  • Ryu, Young-Jo;Lee, Min-Kyung;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.38-45
    • /
    • 2016
  • In this study, we found that the release and dispersion of ammonia can create hazardous atmospheres using FLACS software. In General, ventilation or gas detector installations are recommended as preventive measures to control explosion incidents. However, the ventilation installations cannot be applicable to the refrigeration facility that uses ammonia as refrigerating medium, because the freezing room should be sealed. From the accident investigation of the explosion case, we suggested that all electronic devices were needed to be switched by explosion proof devices, and communication facility was also needed to be installed to announce to all employees within a building in case alert condition like ammonia releases occurred.

The calculation method of the traffic using incidence matrix in vehicle network tunnels (네트워크 도로터널에서 근접행렬을 이용한 교통량 계산 방법)

  • Kim, Hag Beom;Beak, Jong Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.3
    • /
    • pp.561-573
    • /
    • 2018
  • In order to design the ventilation in the road tunnel, it is necessary to know the ratio of average annual daily traffic by vehicle type. In general, the road tunnels are onedirectional tunnel, so the traffic of each vehicle type does not change along the tunnel. On the other hand, in the case of network road tunnels, since the connections in the tunnels are complex, the traffic of vehicle-type varies depending on the network composition of tunnels. In the studying the easy method for calculating the ratio of vehicle type for the network road tunnel are proposed with using incidence matrix.

A Numerical Study On Various Energy and Environmental Systems(Ⅰ) : LPG dispersion, Lake flow, Primary clarifier, Hood ventilation, Cyclone combustor, Dow chlorination reactor. (에너지$\cdot$환경 제반 시스템에 관한 수치 해석적 연구 (Ⅰ) : LPG 확산, 호소 유동, 일차침전조, 국소 환기용 후두, 싸이클론 연소로, Dow 화학 반응로)

  • Jang Dong-Sun;Kim Gyeong-Mi;Lee Eun-Ju;Park Byeong-Su;Kim Bok-Sun
    • Journal of computational fluids engineering
    • /
    • v.2 no.1
    • /
    • pp.93-108
    • /
    • 1997
  • This paper describes several computational results on the various energy and environmental problems using Patankar's SIMPLE method. The specific problems included in this study are : pollutant and flammable material dispersions in open and confined areas, buoyancy-driven flow in a lake, primary clarifier for water and waste water treatment, hood ventilation in workplace. cyclone combustor and Dow chlorination reactor. A control-volume based finite-difference method is employed together with the power-law scheme. The pressure-velocity coupling is resolved by the use of the revised version of SIMPLE, says SIMPLER and SIMPLEC. The Reynolds stresses are closed using the standard or RNG κ-ε models. A nonequilibrium turbulent reaction model is developed for the application of the chlorination process in the Dow thermal reactor. Other important empirical models and physical insights appeared in this study are presented and discussed in a brief note. The computational method developed in this study is considered, in general, as a viable tool for the design and determination of the optimal operating condition of various environmental engineering system of interest.

  • PDF

Box Model Approach for Indoor Air Quality (IAQ) Management in a Subway Station Environment

  • Song, Jihan;Pokhrel, Rajib;Lee, Heekwan;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.184-191
    • /
    • 2014
  • Air quality in a subway tunnel has been crucial in most of the subway environments where IAQ could be affected by many factors such as the number of passengers, the amount and types of ventilation, train operation factors and other facilities. A modeling approach has been introduced to manage the general IAQ in a subway station. Field surveys and $CO_2$ measurements were initially conducted to analyze and understand the relationship between indoor and outdoor air quality while considering internal pollution sources, such as passengers and subway trains, etc. The measurement data were then employed for the model development with other statistical information. For the model development, the algorithm of simple continuity was set up and applied to model the subway IAQ concerned, while considering the major air transport through staircases and tunnels. Monitored $CO_2$ concentration on the concourse and platform were correlated with modeling results where the correlation values for the concourse and platform were $R^2=0.96$ and $R^2=0.75$, respectively. It implies that the box modeling approach introduced in this study would be beneficial to predict and control the indoor air quality in subway environments.

The Survey and its Effect for Cooling Systems used in Dairy Cattle Farms in Gyeonggi (경기지역 젖소 농가 고온저감시설 활용 실태조사 및 축사내 온습도 변화)

  • Lee, Jun-Yeob;Choi, Hee-Cheol;Lee, Dong-Hyun;Woo, Saem-Ee;Ki, Kwang-Seok;Jeon, Jung-Hwan
    • Journal of Animal Environmental Science
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2015
  • This survey was conducted to give the basic information and temperature and humidity variation by cooling systems in dairy farms in Korea. A total of 36 farms were surveyed in Gyeonggi province with the general information of farms such as milk production, and milk quality, types of cooling systems, and its operation method of dairy farms. All of surveyed farms have cooling fan and some have 1 more cooling systems such as sprinkler, foggy systems, ventilation duct, and shower system. Although the indoor THI of cow house was decreased by either ventilation duct or foggy system during hot season, the range belongs to mild heat stress scale for dairy cows.

Relevance between Total Volatile Organic Compound (TVOC) Exposure Level and Environmental Diseases Within Residential Environments (주거환경 내의 Total Volatile Organic Compounds (TVOC) 노출수준과 환경성질환과의 관련성)

  • Lee, Dong-Hyun;Chung, Jin-Do
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.193-200
    • /
    • 2011
  • Objective: The purpose of this study is to compare and analyze the level of exposure to volatile organic compounds for different kinds of households in apartments or houses and analyze the relation between atopy-related symptoms and concentration of volatile organic compounds in order to improve indoor air quality and start to build a process to prevent environmental diseases. Method: From July 2010 to November 2010, TVOC concentration levels were measured and analyzed in 402 general households and 236 weak households, totalling 638 households. Residents were asked to fill out a survey on environmental disease. All resources were analyzed using SPSS 12.0 program. Result: In comparing the differences in concentration levels of volatile organic compounds for different types of households, including existing apartments and houses, the type of housing did not affect the concentration level of volatile organic compounds, but the relevance with skin trouble, diagnosed atopy, and atopy systems all had statistical similarities. Moreover, above-limit volatile organic compounds showed statistical relevance with amount of ventilation, time of construction, skin trouble, diagnosed atopy and atopy symptoms. Conclusion: The study concludes that as the time of construction recedes further into the past and as the amount of ventilation is higher, the exposure level to volatile organic compounds was lower and the group that were suffering from atopy symptoms had higher exposure to volatile organic compounds.

Effects of Manually Controlled Ventilation on Gas Exchange during General Anesthesia (용수조절호흡이 폐포환기 정도에 미치는 영향)

  • Suh, Jung-Kook;Suh, Ill-Sook;Kim, Heung-Dae
    • Journal of Yeungnam Medical Science
    • /
    • v.1 no.1
    • /
    • pp.95-100
    • /
    • 1984
  • In the beginning of anesthetic training, one of the clinical practices that anesthetists have to learn is manually controlled ventilatory techniques. The popularity of manually controlled ventilatory techniques has been gradually decreased with increased use for anesthetic ventilators. However it is important and basic for the anesthetists to master manually controlled ventilatory techniques skillfully. Recently, we analyzed the arterial blood gas in 30 cases before and during general anesthesia, and studied the effects of the manually controlled ventilation on the pulmonary gas exchange. The results were as follow; 1) Mean value of $PaCO_2$ during the manually controlled ventilation, $29.9{\pm}2.9mmHg$ was decreased statistically comparing with that of $PaCO_2$ before the anesthesia, $39.8{\pm}2.8mmHg$. 2) Mean values of pH and ${HCO_3}^-$ during the manually controlled ventilation were $7.48{\pm}0.03$, $22.2{\pm}2.4mEq/l$, respectively and values before the anesthesia were $7.41{\pm}0.02$, $25.2{\pm}1.8mEq/l$, respectively. 3) Mean values of $PaO_2$ and $O_2$ saturation during the manually controlled ventilation were $270.0{\pm}28.8mmHg$, $99.6{\pm}0.2%$, respectively and values before the anesthesia were $92.5{\pm}4.0mmHg$, $96.9{\pm}1.0%$ respectively. These results indicates that manually controlled ventilation at our department of anesthesiology produced mild hyperventilatory state. However these were no significant changes in cerebral blood flow and other biochemical parameters.

  • PDF