• Title/Summary/Keyword: General safety factor

Search Result 337, Processing Time 0.03 seconds

Customized Safety Information Delivery System for Unskilled Construction Worker Training

  • Jo, Junhyeon;Baik, Sangeun;Pedro, Akeem;Lee, Doyeop;Park, Chansik
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.525-532
    • /
    • 2022
  • Accidents at construction sites in Korea account for more than half of all industrial accidents. To solve this problem, a policy to strengthen safety education was implemented to ensure the safety of workers. However, it was analyzed that there is a high possibility of accidents because workers did not receive proper safety information for each risk factor due to general lecture-style education. In addition, statistics show that the accident status of workers with fewer years of period is high, indicating that a customized information delivery method needs to be proposed for unskilled workers with fewer years of period. Research on the importance of education has been conducted, but no information delivery method has been identified. For unskilled workers to effectively receive safety information, appropriate delivery formats (text, photos, illustrations, 4D-BIM, 360-based panorama, video, animation) were analyzed, and a new method of education was proposed. If customized safety information is provided according to this proposal, effective information delivery to unskilled workers will be possible, and it is expected to be verified in various ways.

  • PDF

Feasibility Study of Docetaxel and Cyclophosphamide Six- Cycle Therapy as Adjuvant Chemotherapy for Japanese Human Epidermal Growth Factor Receptor 2-Negative Breast Cancer Patients

  • Abe, Hajime;Mori, Tsuyoshi;Kawai, Yuki;Tomida, Kaori;Kubota, Yoshihiro;Umeda, Tomoko;Tani, Tohru
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4835-4838
    • /
    • 2013
  • Background: We compared treatment completion rates and safety of docetaxel and cyclophosphamide sixcycle therapy (TC6) with docetaxel followed by 5FU, epirubicin and cyclophosphamide (T-FEC) therapy in Japanese patients with human epidermal growth factor receptor 2 (HER2)-negative breast cancer. Materials and Methods: We administered TC6 q3w or T-FEC q3w to HER2-negative breast cancer patients. The primary endpoint of this trial was toxicity. As second endpoints, the treatment completion rate and relative dose intensity were evaluated. Results: The TC6 and T-FEC group consisted of 22 and 21 patients, respectively. Concerning hematological toxicity, grade 3 or higher adverse reactions included neutropenia and febrile neutropenia. As non-hematological adverse events, exanthema and peripheral neuropathy were frequently reported in the TC6 group, whereas more patients of the T-FEC group reported nausea and vomiting. In TC6, the treatment completion rate was 86.4% and the relative dose intensity of docetaxel was 93.2%. In T-FEC, the values were 95.2% and 98.9%, respectively. Conclusions: These results suggest that TC6 is tolerable in Japanese, and that this regimen can also be performed in outpatient clinics. However, with the TC6 regimen, the compliance was slightly lower than with the T-FEC regimen, and supportive therapy needs to be managed appropriately.

Radiation Effects on Electrical Treeing Characteristics of Low Density Polyethylene (저밀도 폴리에틸렌의 방사선 조사에 따른 전기 트리 특성 변화)

  • Lee, Chung;Shin, Hee-Kyung;Kim, Ki-Yup;Park, Soo-Gil;Ryu, Boo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1992-1994
    • /
    • 1999
  • Dicumyl peroxide (DCP) is used for crosslinking agent in general. And the correlation between polyethylene and DCP is significant in particular radiation environment. On this paper, The effects on $Co^{60}{\gamma}$-ray irradiation of polyethylene doped dicumyl peroxide(DCP) were investigated. We experimented on electrical properties as following; electrical tree inception and growing type for applying AC step voltage, AC breakdown strength, volume resistivity, capacitance and dissipation factor at high frequency as increasing dosage. Also, chemical analysis was performed TGA, gel content.

  • PDF

Analysing and comparing efficiency of harmonic reduction equipment for Induction Motor (유도전동기의 고조파 저감장치 성능 비교 분석)

  • Park, Yang-Birm;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.47-52
    • /
    • 2005
  • Recently, power conversion equipment increased rapidly makes a lot of harmonics. Thus, it is growing that wrong operation and break down of sensitive devices. There are two kinds of causes of harmonics. One of them is lots of power conversion equipment as modem controller, inverter, converter and SWS(Switching Mode Power Supply). Another is nonlinear operating machines as transformer and motor. The more nonlinear loads like them grow, the more serious problems as harmonic current to source and low power factor because of increasing reactive power grow. It is installed for reactor and L-C Filter to decrease harmonic in general. This paper analysis and compares two of characteristics and harmonic from reactor and L-C Filter with operation of induction motor and power conversion equipment. In the result, L-C Filter more improves unbalance rate and THD than reactor.

A Study on the Analyzation of Handicapped Facility in Residential outside Area (공동주택단지 옥외공간의 장애인 편의시설 실태분석에 관한 연구)

  • Park, Kwang-Jae;Seong, Ki-Chang
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.11 no.2
    • /
    • pp.45-54
    • /
    • 2005
  • The purpose of this paper is to analyze the handicapped facility in residential outside area, to found how to improve the law in analyzing the residential area and to suggest consideration factor in design phase. To concentrate the study, the objects of case study are selected carefully, also case study method is selected as well as objects. After observing the summary of objects, the checklist is made accordance with the improvement law of facility. The checklist has the general and detail factor about outdoor residential area, and the detail factor is based on the improvement law of facility and is used to examine and analyze.

  • PDF

Development of the Patient Safety Nursing Activities Scale for Clinical Nurses (임상간호사의 환자안전 간호활동 측정도구 개발)

  • Kim, Hwa-Young;Ryu, Seang
    • Journal of Digital Convergence
    • /
    • v.16 no.9
    • /
    • pp.207-217
    • /
    • 2018
  • The purpose of this study was to develop a patient safety nursing activities scale for clinical nurses and to verify validity and reliability it. A preliminary scale was developed through various processes and pilot study. Data were collected from 900 nurses at 28 hospitals selected by proportionate stratified sampling with 331 general hospitals nationwide. The final scale was a 4-point scale, consisting of 72 items in 10 domains. The construct validity was found to be appropriate by exploratory factor analysis and 70.3% of the variance in the total scale and over .74 of factor loading. There was a significant correlation between scale and patient safety culture (r=.52, p<.001) and Cronbach's ${\alpha}$ was .99. This scale developed to measure patient safety nursing activities of clinical nurses was found to be reliable and valid and will be a useful tool in practical field.

Integrity Evaluation of Agitating Axis and Blade in the Organic Waste Reactor (유기성 폐기물 반응기 내부 교반 축 및 블레이드 건전성 평가)

  • Yun, Yu Seong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.1-6
    • /
    • 2017
  • Modern society has been experiencing by population growth and urbanization that bring, a change of eating habits which has occurred a various types of waste in a large amount. Even though these wastes are required an immediate treatment with difficulties unsanitary handling and existing waste treatment method are by incineration, fermentation, drying and etc. however a bad smell occurs after the treatment that need's a lot of energy in processing organic wastes with high moisture contents and wasteful and inefficient problem. The strength assessment of the organic waste agitating vessel is required in terms of safety due to the differences of loading on the shaft that was treated by agitating the mixture of food waste. The damage of agitating axis is depended on steam pressure, temperature condition and the force moment that exerted by the food waste. Thus the strength assessment and stability evaluation are very important, especially to handle a hard waste. In this study the rotation capacity of agitation is about 5 tons considering general structural rolled steel pressure vessel strength and steam pressure. The purpose is to estimate the safety and strength evaluation for a agitator axis and impellers according to the rotating angle of the axis under the condition of the 3.2 ton capacity reactor.

A Study on the Development of the Measuring Scale of Safety Consciousness (안전의식 측정 척도 개발 연구 : 서울시 일부 중학생을 중심으로)

  • 김혜원;이명선
    • Korean Journal of Health Education and Promotion
    • /
    • v.19 no.1
    • /
    • pp.87-107
    • /
    • 2002
  • Recently, the industrialized world is suffering from accidents referring from the lack of safety consciousness. According to Korean Safety Regulation Department(1996), students at junior high schools are mostly involved in safety accidents, and this is due to lack of safety consciousness. To prevent these accidents, we need to have safety consciousness and attitude. To make junior high school students who are mostly affected in these accidents act safely, they need to know their level of safety consciousness. The purpose of this study is to develop a guideline of measuring the scale of safety consciousness and analyze the relationship between safety education, accident experiences and safety consciousness. This study is based on a survey of 708 junior high students in Seoul, which was carried out from 12 November, 2001 to 21 November, 2001. 1. The main fields of safety consciousness are home safety, school safety, fire safety, emergency management based on documents. Home safety is again divided into facility safety and livelihood safety, school safety is divided into facility safety, livelihood safety and laboratory safety, traffic safety is divided into pedestrian safety, bicycling safety and public transportation safety, fire safety divided into prevention and escaping during fire breakouts, emergency management safety is divided into general principles and escaping during emergency situations. 2. The primary safety consciousness scale was made according to every field of safety consciousness. A preliminary examination based on the scale and a study of reliance and the factors was held. Based on these results, 27 questions which were concerned to be impairing reliability or lacking in factor were deleted on the secondary safety consciousness scale development The secondary safety consciousness scale which constituted of 73 questions was put into another preliminary study and after analyzing reliability and the factors, 12 questions of low reliabilities were deleted and with these results, the third scale were made consisting of 61 questions. 3. A study based on the third safety scale which is made of 61 questions, were held and with a analysis of the reliability and factors made, the relationship between safety education, accident experience and safety mind were examined. (1) The study of reliability and factors show that Cronbach's coefficient in home safety fields is .7598, in school safety .7924, in traffic safety .8306, in emergency treatment .7775, in fire safety .7247. The questions indicating low reliability were deleted. The factor analysis revealed that home safety is converged on facility safety and livelihood safety. But one question was deleted because it showed incongruence of validity. School safety was converged on facility safety, livelihood safety and laboratory safety. But 2 questions showed incongruence of validity and these were deleted. Traffic safety fields were converged on pedestrian safety, bicycle safety and public transportation safety. One question showing incongruence of validity was deleted. Emergency treatment fields converged on general principles and acting in emergency situations and three questions showing incongruence of validity were deleted. Fire safety was converged on prevention and acting in fire breakouts. Totally, eight questions were removed and the final scale were consisted of 53 questions (2) The 3/sup rd/ grade students scored higher average safety mind scales than 1st graders(p〈.05). And students who had high scores at school tend to have a higher scale than those who do not(p〈.001). (3) Average scale of students who had experience in safety education were higher(p〈.001). Students who had previously been involved in home safety accidents had a low score(p〈.001). This was same to students with experience in school safety accidents(p〈.001). Students with traffic safety accidents and fire safety accidents tend to have a lower scale too(p〈.05, p〈.001).

Apatinib as a Third-Line Treatment for HER2-Positive Metastatic Gastric Cancer: A Multi-Center Single-Arm Cohort Study

  • Zhang, Xin;Huo, Haoran;Nie, Yanan;Xue, Jiadong;Yuan, Zengjiang;Zhang, Zhenyi
    • Journal of Gastric Cancer
    • /
    • v.22 no.4
    • /
    • pp.408-417
    • /
    • 2022
  • Purpose: Treatment options are limited after the failure of first-and second-line treatments in patients with HER2+ metastatic gastric cancer (mGC). The present study aimed to explore the efficacy, safety, and prognostic factors of apatinib efficacy as a third-line therapy for patients with human epithelial growth factor receptor 2-positive (HER2+) mGC. Materials and Methods: A total of 59 HER2+ mGC patients who received apatinib as third-line therapy were retrospectively enrolled in this two-center, single-arm, cohort study; the clinical response, survival data, and adverse events were retrieved. Results: The median progression-free survival (PFS) was 5.2 months (95% confidence interval [CI], 3.9-6.5), and the median overall survival (OS) was 8.2 months (95% CI, 6.6-9.8) Furthermore, forward stepwise multivariate Cox regression analysis showed that a higher Eastern Cooperative Oncology Group performance status score and multiple metastases were independently correlated with decreased PFS and OS (both P<0.05). The main adverse events were leukopenia (45.8%), hypertension (44.1%), thrombocytopenia (39.0%), hand-foot syndrome (37.3%), and elevated transaminase (33.9%). Grade 3 adverse events mainly included hypertension (5.1%) and neutropenia (5.1%); grade 4 adverse events did not occur. Conclusions: Apatinib is efficient and well tolerated in patients with HER2+ mGC as a third-line treatment, suggesting that it may be a candidate of choice for these patients.

A Study on the Satisfaction and Environmentally-friendly Behaviors in the Urban Parks (친환경적 도시공원 만족도 및 이용형태에 관한 연구)

  • Joo, Shin-Ha
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.6
    • /
    • pp.91-103
    • /
    • 2008
  • The purpose of this study is to compare the satisfaction of the urban parks and to classify and assess the environmentally-friendly behaviors in the urban parks. For this purpose, the park user's behaviors and satisfactions were surveyed in 10 parks in Seoul and its suburb area. Parks are divided into 2 types, the walking-distance parks and the metropolitan parks, by time to reach, visit frequency and visit purpose. The park users are generally satisfied with the facilities, but not satisfied with some specific items, such as cultural facilities, accommodations for the handicapped, safety facilities and sports facilities. The environmentally-friendly behaviors are positively assessed in general, but the behavior of the natural experience was negatively assessed. The environmentally-friendly behaviors in the urban parks are classified into 2 factors; the experience factor and the activity factor. The parks are categorized into 3 types by these factors. For type I parks, the experience factor is dominant, but the activity factor is relatively low. For type II parks, the both factors are low and the parks are necessary to improve. And type III parks are positively assessed in the aspect of the environmentally-friendly behaviors, even though some park are necessary to complement.