• Title/Summary/Keyword: General performance test

Search Result 1,210, Processing Time 0.039 seconds

Analysis of Remote Electrical Facilities Safety Checkup for General Use (일반용 전기설비 수용가의 원격전기안전점검 모델 설계 및 요소기술 분석)

  • Yoo, Jae-Geun;Choi, Myeong-Il;Jeon, Jeong-Chay
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2214-2215
    • /
    • 2008
  • KESCO performed periodical inspection every 1${\sim}$3 years to check the status of maintenance and performance of electric installations for general use (less than 600V in voltage and 75kW in capacity in residential homes) but recently a resident have been avoiding periodical check due to increase of sex crime and empty house, which more and more difficult to secure electrical safety of installation. In order to solve non-inspection problems and improve efficiency of inspection, this paper introduce the model of remote monitoring system that check electrical facilites for general use and we are developing remote monitoring device for reliability test.

  • PDF

Performance Evaluation Involving Multiple Parameters in Built-In-Test Systems

  • Kang, Hee-Jung;Yoo, Wang-Jin
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.16 no.2
    • /
    • pp.148-158
    • /
    • 1991
  • The Built-In-Test (BIT) system is an integrated subsystem for the determination of the health status of any primary system. The BIT consists of hardware and software installations directed at performance of the functions of fault detection, diagnosis and isolation, as well as primary system record failure information. Evaluation of the difinitions appropriate to the BIT system, including system characteristics and parameters, is important to an understanding of system functions. The object of this paper is to present general definitions of the BIT diagnosis parameters and a semiquantiative evaluation method for BIT systems. Finally, two case studies for actual problem solutions are included.

  • PDF

Load Transfer Capacity for the Planar Joints between Existing and New Slab in Apartment Remodelling Construction for Enlarging the Interior Space (평면확장형 공동주택 리모델링 공사에서 신/구 슬래브 접합부의 횡방향 하중전달 능력)

  • You Young Chan;Kim Seung Hun;Choi Ki Sun;Kim Keung Hwan;Lim Byung Ho;Yu Jee Yeung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.295-298
    • /
    • 2005
  • In General, post-installed dowel bars are used as a shear connector to ensure the composite actions between new slabs and existing slabs in an apartment remodelling constructions expecially for enlarging the interior space outward the existing buildings. But, it has not been checked that the connection performance between existing and new slab is satisfactory not only for the structural safety condition but also the for serviceability and dwelling requirements. In this research, an experimental works were presented to evaluate the load transfer capacity for the planar joints between existing and new slab. The existing slabs were obtained from the existing apartment housing which will be demolished. Test results showed that the planar joints with post-installed dowel bars behaved in full composite modes until ultimate capacity of test specimens, so sufficient ultimate and serviceability performance are confirmed.

  • PDF

Experimental and analytical investigations on seismic behavior of ductile steel knee braced frames

  • Zahrai, Seyed Mehdi;Jalali, Meysam
    • Steel and Composite Structures
    • /
    • v.16 no.1
    • /
    • pp.1-21
    • /
    • 2014
  • Knee Braced Frame (KBF) is a special form of ductile eccentrically braced frame having a diagonal brace connected to a knee element, as a hysteretic damper, instead of beam-column joint. This paper first presents an experimental investigation on cyclic performance of two knee braced single span one-story frame specimens. The general test arrangement, specimen details, and most relevant results (failure modes and hysteretic curves) are explained. Some indexes to assess the seismic performance of KBFs, including ductility; response reduction factor and energy dissipation capabilities are also subsequently discussed. Experimental results indicate that the maximum equivalent damping ratios achieved by test frames are 21.8 and 23% for the specimens, prior to failure. Finally, a simplified analytical model is derived to predict the bilinear behavior of the KBFs. Acceptable conformity between analytical and experimental results proves the accuracy of the proposed model.

Manufacturing and Performance Test for Bogie System of Urban Maglev (도시형 자기부상열차의 주행장치시스템 제작 및 성능 시험)

  • Yu, Young-Don;Lee, Nam-Jin;Kang, Kwang-Ho;Lee, Won-Sang;Han, Hyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.590-596
    • /
    • 2010
  • Maglev vehicles levitated and propelled by electromagnet as non-contact between vehicle and guide rail is environmentally friendly transport system which have many advantages like ride comfort and guide way construction costs. As a goal of commercial operation at Incheon International Airport in 2012, development of vehicle is underway and proto-vehicle is test running at KIMM. The maglev bogie system of proto-vehicle, like railway vehicle, has functions to support weight of vehicle, transfer force of brake and propulsion and improve ride comfort through insulation of vibration and improve curve negotiation capability. The main components of a bogie are two modules consisted of electromagnetic, frame and linear motor, two tie beams to connect two modules and steering system to improve curve negotiation capability. The purpose of this paper is to describe general specification, structure, manufacturing process, performance testing, ride comfort of proto-vehicle and bogie system.

  • PDF

Performance of CQUEAN camera

  • Choi, Chang-Su;Park, Won-Kee;Jeon, Yi-Seul;Pak, Soo-Jong;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.63.1-63.1
    • /
    • 2010
  • CQUEAN (Camera for QUasars in EArly uNiverse) is a newly developed camera system by CEOU optimized at 0.8 - $1.1{\mu}m$ wavelength region. From Aug. 10 to Aug. 17, 2010, the camera was installed at 2.1m Otto Struve telescope at McDonald Observatory, USA, and engineering test observation was performed. We obtained the data for the characteristics of camera and scientific purpose using 7 filters (g, r, i, z, Is, Iz, Y). For the purpose of discovery of z - 5~6 quasar, we specially used new filters (Is,Iz). During the test observation, we obtained the data of Gamma-Ray Burst, high redshift quasars, high redshift quasar candidates and other calibration data. We present general characteristics of the reduced data taken with CQUEAN and show the performance of the camera.

  • PDF

Performance and Evaluation of Flexural Toughness Indices for HPFRCCs (고인성 섬유보강 시멘트 복합체의 휨인성 성능 및 평가)

  • Han Byung Chan;Yang Il-Seung;Park Wan Shin;Jeon Esther;Kim Sun Woo;Yun Hyun Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.615-618
    • /
    • 2004
  • The primary role of fibers in High performance fiber reinforced cement composites(HPFRCCs) is to improve the toughness, or energy absorption capacity, of the composite material, However, there is still no general agreement as to how this toughness should be characterized, or how it might be used in the design of structures containing HPFRCCs. In this paper, therefore, we focus on test techniques for measuring flexural toughness. For mechanical properties, HPFRCCs can be tested in the same way as fiber reinforced concrete(FRC). Both the significance and the limitations of somewhat different national and industrial standards of FRC are discussed. For flexural toughness, with depend on the presence of fibers, new test methods was developed and verified. We also suggest evaluation method of tensile toughness indices using the moment curvature relationship in flexural tests.

  • PDF

A new contrast ratio measurement method using image patterns

  • Choi, Dong-Wook;Yang, Sun-A;Bae, Jae-Woo;Lee, Seung-Bae;Chung, Ho-Kyoon
    • Journal of Information Display
    • /
    • v.12 no.2
    • /
    • pp.85-87
    • /
    • 2011
  • The contrast ratio is one of the most important performance parameters for display devices. The general method of measuring the contrast ratio is to determine the ratio of the full-screen white pattern to the full-screen black pattern, according to the Video Electronics Standards Association standard. Real TV images seldom have these images, however, and the conventional method does not reflect the true performance of the display in actual use. In this paper, a new contrast ratio measurement method that uses image patterns is proposed, to demonstrate that active matrix organic light-emitting diode TVs have a higher contrast than LED (LCD) TVs.

The Performance of a Heat Pump with a Variation of Expansion Valve at Various Charging Conditions (냉매 충전량과 팽창장치 변화에 따른 열펌프 시스템의 성능특성에 관한 연구)

  • 최종민;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.661-666
    • /
    • 2003
  • Constant area expansion devices such as capillary tubes, short tube orifices are being gradually replaced with electronic expansion valves (EEVs) because of increasing focus on comfort and energy conservation. In this study, the performance of a water-to-water heat pump as a function of refrigerant charge is investigated in steady state, cooling mode operation with expansion devices of a capillary tube and an EEV. The performance of the capillary tube system varies drastically according to the change of refrigerant charge amount and inlet temperature of the secondary fluid in the condenser. Cooling capacity and COP of the EEV system show little dependence on the refrigerant charge, while those are strongly dependent on the secondary fluid temperature at the condenser inlet. In general, for a wide range of operating conditions the EEV system shows much higher performance as compared with the capillary tube system. The performance of the EEV system can be optimized by adjusting EEV opening to maintain a constant superheat at all test conditions.

The Effect of Self-leadership and Communication Barriers on Nursing Performance in Hospital Nurses (병원간호사의 셀프리더십, 의사소통 장애가 간호업무성과에 미치는 영향)

  • Cho, Jeong Lim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.2
    • /
    • pp.239-246
    • /
    • 2019
  • Purpose: The purpose of this study was to identify factors influencing nursing performance in hospital nurses. Methods: The participants were 194 nurses working in one general hospitals in B cities. Data were collected from January 30 to March 30, 2018. SPSS/WIN 18.0 was used for analysis with t-test, ANOVA, $Scheff{\acute{e}}$ test, Pearson correlation coefficients and Stepwise multiple regression. Results: There was a significant correlation between nursing performance and self-leadership (r=.59, p<.001) and communication barriers (r=.35, p<.001). In the multiple regression, self-leadership (${\beta}=.50$, p<.001), position (${\beta}=.15$, p=.011) and communication barriers (${\beta}=.16$, p=.014) were associated with nursing performance. These factors accounted for 37% of the total variance in nursing performance. Conclusion: Considering the results of this study, educational programs to improve self-leadership and communication barriers should be developed and implemented in order to foster nursing performance in hospital nurses.