• 제목/요약/키워드: General illumination

검색결과 137건 처리시간 0.028초

Inorganic phosphors for LED applications

  • Winkler, Holger;Barnekow, Peter;Benker, Andreas;Petry, Ralf;Tews, Stefan;Vosgroene, Tim
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.56-59
    • /
    • 2009
  • In the nineties the invention of the InGaN blue LED has innovated illumination technology. Currently LCD backlighting and more and more general lighting applications are based on white LEDs comprising of inorganic phosphors and blue emitting InGaN chip. Well established phosphor materials are ortho silicates and garnets like yellow emitting YAG:Ce. In our paper we demonstrate that garnet materials also allow for green light emission for both, general lighting and backlighting LED applications.

  • PDF

지하공간의 환경 및 안전관리 요소 (The Factors Governing Envlronment and Safety in Underground Spaces)

  • 김복윤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 지하공간 건설기술에 관한 서울 심포지움 논문집
    • /
    • pp.133-162
    • /
    • 1993
  • The environment of underground spaces might be considered in view of working environment during the construction and living environment after completion of the construction work. For controlling environment of underground space, an appropriate measures have to be taken on the governing factors such as air flow, dust, gases, heat, radiation, noise, illumination and water. The more critical matter, in underground environmental point of view, is underground disasters such as fire, gas explosion and water inrush. This paper presents the general introduction of these factors mentioned above and some outcomes of research works as of now.

  • PDF

Enhanced Lifetime and Efficiency of Organic Light Emitting Diodes

  • Choi, Han-Ho;Kim, Myung-Seop;Park, Sang-Tae;Yang, Joong-Hwan;Kim, Sung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1803-1804
    • /
    • 2006
  • In this paper, device performances of organic lightemitting diodes (OLEDs) will be presented for AMOLED and general illumination applications. Various types of advanced devices were developed to enhance the power efficacy and luminous efficiency. Here we also demonstrated longer lifetime AM-OLED structures, which lifetime is about 100 hours until $L/L_0$ reaches 0.99.

  • PDF

A Study on target tracking system for a mobile robot using ultrasonic sensors

  • Kim, Hon-Hui;Han, Dong-Hui;Ha, Yun-Su
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.134.5-134
    • /
    • 2001
  • The capability of environment recognition is very important for mobile robot. Especially, a function of target tracking is necessary in monitoring and watching an object using mobile robot. In general, vision sensors such as CCD camera and laser range finder were used for tracking of a moving target. However, they are not only affected by intensity of illumination in environment but also require high performance processors to process large amount of data. Therefore, in this paper, we propose the construction of target tracking system for mobile robot using only ultrasonic sensors to cope with these problems.

  • PDF

제방 균열의 분광정보 및 반사율 특성에 관한 연구 (A Study on the Spectral Information and Reflectance Characteristic of Levee Crack)

  • 김종태;이창훈;강준구
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.17-24
    • /
    • 2020
  • 본 연구는 제방 균열의 탐지를 위해 드론 기반의 초분광 영상을 활용하여 균열의 분광정보 및 반사율을 분석하는 것이 목적이다. 초분광 센서는 드론에 탑재된 Nano-Hyperspec을 사용하였으며 안동댐 하류 제방 균열을 대상으로 조도별 초분광 영상을 촬영하였다. 조도와 최대강도에 대한 분석 결과 상관관계를 보였으며 비균열 영역과 균열 영역의 결정계수는 각각 0.9864, 0.9851로 계산되었다. 각 영역별 같은 포인트의 반사율은 조도에 상관없이 유사한 값과 패턴을 보였으며 반사율 계산 시 기준이 되는 백색판이 조도에 따라 변하기 때문인 것으로 판단된다. 균열 영역에서 반사율은 비균열 영역에 비해 가시광선에서는 5.65%, 근적외선에서는 4.58% 낮게 나타났다. 향후 드론 촬영을 위한 짐벌 방향과 카메라 각도 등이 보정되면 좀더 정확한 균열 탐지가 가능하며 특히 초분광 영상은 일반 RGB 영상으로 확인이 어려운 균열 심도, 점토광물 종류 등에 대한 탐지가 가능하기 때문에 제방 안정성 평가를 위한 선제적 대응방법이 될 것으로 판단된다.

소프트 프루핑에서 최적의 Profiling을 이용한 컬러 관리에 관한 연구 (A Study on Color Management using Optimum Profiling in Soft Proofing)

  • 차재영;조가람;구철회
    • 한국인쇄학회지
    • /
    • 제27권1호
    • /
    • pp.1-14
    • /
    • 2009
  • The color reproduction of digital still camera does not, in general, match those of the final output device. Because color gamut of these devices is different, it is therefore necessary to take account of a way to match. The way uses the optimized profile to output device an image. This paper proposed a way to create the input profile of digital still camera for standardization soft proofing process. The results of proposed way showed that for input profiles equivalent, good results relatively. In this paper, an experiment was done where the illumination sources used as the standard illumination 5200K and illuminated at a $45^{\circ}$ angle in the best illumination efficiently. The white balance was in mode 'custom' : aperture F11, exposure time 1/60s, ISO50, focal length 80mm. The images were exported and saved as 16bit RGB TIFF(AdobeRGB, sRGB, ProphotoRGB) images. To do the test, the RGB values of the RGB TIFF images are processed through the ICC input profile to arrive at processed $CIEL^*a^*b^*$ values. A profiling tool such as ProfileMaker 5.0 and Monacoprofile 4.8 are used to do this. The processed $CIEL^*a^*b^*$ values are compared to the reference $CIEL^*a^*b^*$ values and these two values are used to calculate a ${\Delta}E{^*}_{ab}$.

  • PDF

미세혈관 수술 후 혈관 연축의 예방을 위한 개선된 온열전등 (Improved Heat Lamp for Preventing Arterial Spasm after Microvascular Surgery)

  • 안성민;황소민;허은숙;박정미;박경아;오진아
    • Archives of Reconstructive Microsurgery
    • /
    • 제17권2호
    • /
    • pp.120-125
    • /
    • 2008
  • Purpose: Heat therapy by heat lamp after microvascular surgery is being used for preventing blood vessels's contraction and blood-flow's disturbance. As usually, incandescent lamp has been used. But there have been several problems and need for improvement in the existing heat lamp treatment. So we would like to introduce improved heat lamp to keep an appropriate temperature and intensity of illumination. Methods: The existing heat lamps are the ones of general light stands covered with newspaper, having 60 watt light bulb of incandescence and lampshade made of aluminum. We have tried to improve shortcomings of the existing heat lamps by enlarging the size of aluminum lampshade and attaching a curtain that can block heat and light. We conducted a comparative study between the existing and improved heat lamps. Under the assumption that there are several affected parts, we have also measured the distance from heat lamp to patients' eye region and then intensity of illumination. Result: The target temperature of surface was realized in 11 minutes with the maximum temperature reaching at 36.6 degrees C in 28 minutes at the existing heat lamp while the target temperature reached in 7 minutes with the maximum temperature reaching at 39.0 degrees C in 17 minutes at the improved heat lamp. The existing and improved heat lamp showed 38 lx and 0.1 lx of intensity of lumination, respectively. Conclusion: Using improved heat lamps, we can keep an appropriate temperature and we think we can make contribution to patients' treatment by making them and their neighbors able to sleep with minimized disturbance thanks to low intensity of illumination secured by blocking light.

  • PDF

인쇄 공정의 최적화를 위한 디지털카메라의 Profiling (Digital Still Camera Profiling for the Optimization Of Printing Process)

  • 차재영;조가람;구철회
    • 한국인쇄학회지
    • /
    • 제26권2호
    • /
    • pp.65-77
    • /
    • 2008
  • The color reproduction of digital still camera does not, in general, match those of the final prints. Because color gamut of these devices is different, it is therefore necessary to take account of a way to match. The way uses the optimized profile to print an image. This paper proposed a way to create the input profile of digital still camera for standardization printing process. The results of proposed way showed that for input profiles equivalent, good results relatively. In this paper, an experiment was done where the illumination sources used as the standard illumination 5200K and illuminated at a $45^{\circ}$ angle in the best illumination efficiently. The white balance was in mode 'custom': aperture F11, exposure time 1/60s, ISO50, focal length 80mm. The images were exported and saved as 16bit RGB tiff(AdobeRGB, sRGB, ProphotoRGB) images. To do the test, the RGB values of the RGB tiff images are processed through the ICC input profile to arrive at processed $CIEL^*a^*b^*$ values. A profiling tool such as ProfileMaker 5.0 and Monacoprofile 4.8 are used to do this. The processed CIEL*a*b* values are compared to the reference CIEL*a*b* values and these two values are used to calculate a ${\Delta}E$.

  • PDF

CRT 모니터의 배경계조도가 영상의 시각인식에 미치는 영향 (The Effect of Background Grey Levels on the Visual Perception of Displayed Image on CRT Monitor)

  • 김종효;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.63-72
    • /
    • 1993
  • In this paper, the effect of background grey levels on the visual perception of target image displayed on CRT monitor has been investigated. The purpose of this study is to investigate the efficacy of CRT monitor as a display medium of image Information especially in medical imaging field. Tllree sets of experiments have been performed in this study : the first was to measure the luminance response of CRT monitor and to find the best fitting equation, and the second was the psychophysical experiment measuring the threshold grey level differences between the target image and the background required for visual discrimination (or various background grey levels, and the third was to develop a visual model that is predictable of the threshold grey level difference measured in the psychophysical experiment. The result of psycophysical experiment shows that the visual perception performance is significantly degraded in the range of grey levels lower than 50, which is turned out due to she low luminance change of CRT monitor in this range while human eye has been adapted lo relatively bright ambient illumination. And it Is also shown in the simulation study using the developed visual model that the dominant factor degrading the visual performance is the reflected light from the monitor surface by ambient light in general illumination condition.

  • PDF

강의실 빛 환경의 층별 , 시간대별 비교연구 (A comparative study on the light environment of the classroom classified by floor , time)

  • 곽경숙
    • 한국주거학회논문집
    • /
    • 제4권2호
    • /
    • pp.1-9
    • /
    • 1993
  • This study is a basic research to analyze and estimate the light environment of the classroom by serial correlation of time. Its purpose lies in the comparison by time period in order In select floor for laboratory and to calculate the uniformity factor. The proving ground is T building in W university, Which is five floor of central hall type. The subject of investigating is eight classrooms, four rooms in South and North, from the second floor that is net influenced by the shelter. The results that compared and estimated them in the illumination of daylight, Uniformity factor, Daylight factor, are as follows1. The illumination of classroom in South and North is over 10001x, but the classroom in North is good and the classroom in South excellent.2. The uniformity factor of classroom in South is good and that of classroom in North is normal.3. The daylight factor of each classroom is over 5% but the classroom in South is above that in North. The classroom in South surpasses the classroom in North in the general light environment and the classroom in third and fourth floor is so better than that in second and fifth floor in the condition of laboratory In the uniformity factor, the classroom in fourth can be better than any classroom.

  • PDF