• Title/Summary/Keyword: General bacteria

Search Result 446, Processing Time 0.068 seconds

Probiotics and Prolongation of Life (유산균 Probiotics와 생명의 연장에 대한 고찰)

  • Oh, Se-Jong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.26 no.2
    • /
    • pp.31-37
    • /
    • 2008
  • One hundred one years have passed since Metchnikoff made his first scientific contribution to probiotics study. Intestinal lactic acid bacteria (LAB) for humans are closely associated with the host's health because LAB is an important biodefense factor in preventing colonization and subsequent proliferation of pathogenic bacteria in the intestine. A probiotic is recently defined as "live microorganisms that when administered in adequate amount confer a health benefit on the host". Some species of LAB have been claimed as probiotics, such as Lactobacillus acidophilus, L. casei, L. fermentum, L. plantarum, L. reuteri, and Lactococcus lactis. For understanding the general mechanism of probiotics, this paper would explore the early studies relating to probiotics and intestinal microbiota, and briefly introduce the Prolongation of Life written by Elie Metctmikoff.

  • PDF

Profiling Total Viable Bacteria in a Hemodialysis Water Treatment System

  • Chen, Lihua;Zhu, Xuan;Zhang, Menglu;Wang, Yuxin;Lv, Tianyu;Zhang, Shenghua;Yu, Xin
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.5
    • /
    • pp.995-1004
    • /
    • 2017
  • Culture-dependent methods, such as heterotrophic plate counting (HPC), are usually applied to evaluate the bacteriological quality of hemodialysis water. However, these methods cannot detect the uncultured or viable but non-culturable (VBNC) bacteria, both of which may be quantitatively predominant throughout the hemodialysis water treatment system. Therefore, propidium monoazide (PMA)-qPCR associated with HPC was used together to profile the distribution of the total viable bacteria in such a system. Moreover, high-throughput sequencing of 16S rRNA gene amplicons was utilized to analyze the microbial community structure and diversity. The HPC results indicated that the total bacterial counts conformed to the standards, yet the bacteria amounts were abruptly enhanced after carbon filter treatment. Nevertheless, the bacterial counts detected by PMA-qPCR, with the highest levels of $2.14{\times}10^7copies/100ml$ in softener water, were much higher than the corresponding HPC results, which demonstrated the occurrence of numerous uncultured or VBNC bacteria among the entire system before reverse osmosis (RO). In addition, the microbial community structure was very different and the diversity was enhanced after the carbon filter. Although the diversity was minimized after RO treatment, pathogens such as Escherichia could still be detected in the RO effluent. In general, both the amounts of bacteria and the complexity of microbial community in the hemodialysis water treatment system revealed by molecular approaches were much higher than by traditional method. These results suggested the higher health risk potential for hemodialysis patients from the up-to-standard water. The treatment process could also be optimized, based on the results of this study.

Antioxidative Ability of Lactic Acid Bacteria (유산균의 항산화 효과)

  • 김현수;함준상
    • Food Science of Animal Resources
    • /
    • v.23 no.2
    • /
    • pp.186-192
    • /
    • 2003
  • The health benefits of friendly bacteria first came to the attention of the general public in 1908, when Dr. Elie Metchnikoff, a Russian biologist, wrote The Prolongation of Life. The longevity may be, in part, due to the antioxidative ability of lactic acid bacteria. However, the antioxidative effect of lactic acid bacteria has been reported only recently. Many kinds of reactive oxygen species can be formed in the human body and in food system, oxidative stress plays a significant pathological role in human disease. Antioxidants are effective for the reduction of oxidation induced by oxygen radicals by scavenging reactive oxygen species. Various synthetic and natural antioxidants have been reported, but there are doubts about the safety and long term effects on health. Antioxidants from natural sources are likely to be found more desirable. An elevated scavenging ability of reactive oxygen species would be a good property for commercially applied lactic acid bacteria. Antioxidant supplement or food containing antioxidants would be greatly applied for the reduction of oxidative damage for human body, and lactic acid bacteria are potentiated candidates for the production of functional foods or natural antioxidant supplements.

Study on the Chlorine-Resistant Bacteria Isolated from Water Pipe Network (상수도관망에서 분리한 잔류염소 내성균에 관한 연구)

  • Hyun, Jae-Yeoul;Yoon, Jong-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.3
    • /
    • pp.334-341
    • /
    • 2011
  • The free residual chlorine of tap water samples, collected from 266 faucets on the water pipe network in Daegu City, was between 0.1 and 0.79 mg/L. On microorganic tests, general bacteria and the coliform goup were not detected and thus the tap water was turned out to be fit to drink. In particular, samples of which free residual chlorine was 0.1 mg/L and over were cultured in R2A agar media at $25^{\circ}C$ for 7 days, and as a result heterotrophic bacteria were detected in 65.9% of samples; (1). The closer tap water got to the faucet from the stilling basin, the lower residual chlorine concentration became but the more the bacterial count became. And, more bacteria were detected in the R2A agar medium than in the PCA medium. (2). In the case of separated strains, most colonies were reddish or yellowish. 16S rRNA sequence was identified as Methylobacterium sp. and Williamsia sp., and yellow strain was identified as Sphingomonas sp., Sphingobium sp., Novosphingobium sp., Blastomonas sp., Rhodococcus sp. and Microbacterium sp. White strain was identified as Staphylococcus sp. (3). Sterilized tap water in polyethylene bottles was inoculated with separated strain and was left as it was for 2 months. As a result, bio-film was observed in tap water inoculated with Methylobacterium sp. and Sphingomonas sp. It was found that heterotrophic bacteria increased when free residual chlorine was removed from tap water in the water pipe network. Thus, there is a need to determine a base value for heterotrophic bacteria in order to check the cleanliness of tap water in the water pipe network.

Antimicrobial Activity of Oleanolic Acid, Ursolic Acid, and Sophoraflavanone G against Periodontopathogens

  • Park, Soon-Nang;Kook, Joong-Ki
    • International Journal of Oral Biology
    • /
    • v.38 no.4
    • /
    • pp.149-154
    • /
    • 2013
  • In general, oleanolic acid (OA) and ursolic acid (UA) have antimicrobial effect against Gram-positive bacteria but not Gram-negative bacteria whereas sophoraflavanone G has antimicrobial activity against both bacterial types. However, the antimicrobial effects of OA, UA, and sophoraflavanone G against periodontopathogens have not been studied to any great extent. The aim of this study was to investigate antimicrobial effect of OA, UA, and sophoraflavanone G against 15 strains (5 species) of oral Gram-negative bacteria, which are the major causative bacteria of periodontal disease. The antimicrobial activity was evaluated by minimal inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) determinations. OA and UA showed antimicrobial effects against all of the Porphyromonas gingivalis strains tested and also Prevotella intermedia ATCC $25611^T$. Interestingly, P. intermedia ATCC 49046 showed greater resistance to OA and UA than P. intermedia ATCC $25611^T$. In contrast, sophoraflavanone G had antimicrobial activity against all strains, with MIC and MBC values below $32{\mu}g/ml$, except Aggregatibacter actinomycetemcomitans. These results indicate that sophoraflavanone G may have potential for use in future oral hygiene products such as dentifrices and gargling solution to prevent periodontitis.

Hygiene of fish feed I. Effect of gamma radiation on the pathogenic bacteria of fish (어류양식용 사료의 위생화 I. 어류유래 병원성 세균에 대한 방사선 조사의 효과)

  • Kim, Se-ra;Lee, Jong-hwan;Jo, Sung-kee;Byun, Myung-woo;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.2
    • /
    • pp.219-225
    • /
    • 2001
  • The gamma-radiation sensitivity of three kinds of pathogenic bacteria to fish was investigated. $D_{10}$ values (irradiation dose required to inactivate 90% of the population) of Edwardsiella tarda, Vibrio anguillarum and Streptococcus faecalis were 0.08, 0.10 and 0.44 kGy, respectively. The inactivation factors were 4.50 - 24.30 and 6.75 - 36.45 at radiation doses of 2 and 3 kGy. Raw moist pellets were inoculated with Edwardsiella tarda, Vibrio anguillarum or Streptococcus faecalis. Inoculated feed samples were packaged in air and irradiated at 5 kGy. This dose was effective in controlling the inoculated and general bacteria in fish feed. We consider gamma-radiation to be an effective method to sterilize pathogenic bacteria in fish feed.

  • PDF

Atmospheric Distribution Characteristics of Airborne Bacteria in Part of Seoul Area (일부 서울 지역 대기 부유세균 분포 현황 조사)

  • Kim, Ki-Youn;Kim, Yoon-Shin;Lee, Cheol-Min;Cho, Man-Su;Byeon, Sang-Hoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.493-502
    • /
    • 2009
  • The concentrations of outdoor airborne bacteria measured in Seoul, Korea for one year (Jan. 2008~Dec. 2008) ranged from $500CFU/m^3$ to $7,500CFU/m^3$. In monthly concentration distribution, the level of outdoor airborne bacteria was highest in September and October and lowest in March. In seasonal concentration distribution, the order of level of outdoor airborne bacteria was autumn>winter>spring>summer. In regional concentration distribution, the highest level of outdoor airborne bacteria was generally found in the forest, followed by general area and traffic site. In distribution characteristics according to particle size, outdoor airborne bacteria showed 31% for >$7.0{\mu}m$ (stage 1), 21% for $4.7{\sim}7.0{\mu}m$(stage 2), 15% for $3.3{\sim}4.7{\mu}m$(stage 3), 19% for $2.1{\sim}3.3{\mu}m$(stage 4), 10% for $1.1{\sim}2.1{\mu}m$(stage 5), and 4% for $0.65{\sim}1.1{\mu}m$(stage 6) and its mean respirable fraction was 48%. In concentration distribution by yellow dust, the mean levels of outdoor airborne bacteria were 803 $(\pm479)CFU/m^3$ for period of yellow dust and 691 $(\pm1,134)CFU/m^3$ for period of non-yellow dust. Although the level of outdoor airborne bacteria was higher in period of yellow dust than period of non-yellow dust, there was no significant difference between period of yellow dust and non-yellow dust (p>0.05). In correlation analysis between outdoor airborne bacteria and atmospheric factors (temperature and relative humidity), there was no significant correlation between outdoor airborne bacteria and atmospheric factors. The predominant airborne bacteria were identified to the Bacillus-derived species.

Sterilization of Yakju(Rice Wine) on a Serial Multiple Electrode Pulsed Electric Field Treatment System (직렬배열 다중전극 고전압 펄스 전기장 처리장치를 이용한 약주의 살균)

  • Mok, Chull-Kyoon;Lee, Sang-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.356-362
    • /
    • 2000
  • Yakju(rice wine) was sterilized with high-voltage square-wave pulses of $1\;{\mu}s$ duration at various electric field strengths and frequencies on a serial multiple electrode pulsed electric field(PEF) treatment system consisted of 7 electrodes connected in series. The initial microbial counts of Yakju were $1.88{\times}10^3{\sim}2.13{\times}10^4$ CFU/mL for total aerobes, $1.55{\times}10^3{\sim}2.85{\times}10^4$ CFU/mL for lactic acid bacteria and $1.72{\times}10^3{\sim}2.39{\times}10^4$ CFU/mL for yeasts. The sterilization of microorganisms in Yakju was a first order reaction and the sterilization effect increased as the field strength and the frequency increased. The $D_{Hz}-value$ and the $D_{PEF}-value$ decreased with the electric field strength. Yeast showed lower $D_{PEF}-value$ than bacteria. Lactic acid bacteria showed lower $D_{PEF}-value$ than general aerobic bacteria under the electric field strength below 30 kV/cm, but higher ones under that above 40 kV/cm. The $Z_{PEF}-value$ of general aerobic bacteria, lactic acid bacteria and yeast in Yakju were 39.4, 49.3 and 47.6 kV/cm, respectively. The PEF sterilization resulted in less changes in color and sensory properties than heat sterilization, and the PEF treated Yakju showed superior quality to the heat treated one. The commercial sterilization of Yakju was accomplished with 2-cycle treatment on the tested serial PEF treatment system.

  • PDF

Evaluation of Characteristics of Microorganisms Isolated from Public Drinking Water Facilities in Gwangju City (광주지역 먹는물 공동시설의 미생물 특성 및 분포조사)

  • Park, Juhyun;Kim, Seonjung;Lee, Youn-gook;Kim, Nanhee;Kang, Yumi;Bae, Seokjin;Kim, Jongmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.2
    • /
    • pp.182-191
    • /
    • 2021
  • Objective: This study was performed to detect indicator bacteria in drinking spring water samples in Gwangju City and to identify their genus using the VITEK-II system. Methods: The subjects were ten drinking spring water sites in Gwangju. Samples of spring water were taken every month from September 2019 to August 2020. We analyzed for the indicator bacteria Yersinia and microorganisms isolated from the spring water. Result: According to the research results on indicator bacteria, general bacteria in st1-st7 with sterilization facilities in the spring and summer were investigated in the range of 0-2 CFU/mL and 0-12 CFU/mL. In st9, where a sterilization facility was not installed, the most general bacteria were detected (160 CFU/mL). Total coliform and fecal coliform showed unsatisfied rates of 16.7 and 11.1% in spring and 14.7 and 11.8% in summer, respectively. The unsatisfied rates of total coliform for the designated and non-designated spring water facilities were 3.8 and 47.1%, respectively, and for the fecal coliform group they were 2.5 and 35.3%. The difference was confirmed according to the presence of a sterilization facility. Yersinia spp. was not detected in all drinking spring water. Forty-one strains in 25 species were isolated from ten sites. The results classified as major dominant species are Pseudomonas spp. 14.6%, Pantoea spp. 9.8%, Serratia spp. 9.8%, Acinetobacter spp. 9.8%, Citrobacter spp. 7.3%, Bordetella spp. 7.3%, Delftia spp. 4.9%, and Enterobacter spp. 4.9%. Conclusions: Based on the result that various species derived from fecal pollution and artificial pollutants were detected in the non-specified public spring water facilities that many people use, the facilities need institutional complements such as continuous management or complete shutdowns.

Microbiological Hazard Analysis for HACCP System Application to Vinegared Pickle Radishes (식초절임 무의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.69-74
    • /
    • 2013
  • This study has been performed for 150 days from February 1 - June 31, 2012 aiming at analyzing biologically hazardous factors in order to develop HACCP system for the vinegared pickle radishes. A process chart was prepared as shown on Fig. 1 by referring to manufacturing process of manufacturer of general vinegared pickle radishes regarding process of raw agricultural products of vinegared pickle radishes, used water, warehousing of additives and packing material, storage, careful selection, washing, peeling off, cutting, sorting out, stuffing (filling), internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, E. coli O157:H7, Clostridium perfringens, Yeast and Mold before and after washing raw radishes, Bacillus cereus was $5.00{\times}10$ CFU/g before washing but it was not detected after washing and Yeast and Mold was $3.80{\times}10^2$ CFU/g before washing but it was reduced to 10 CFU/g after washing and other pathogenic bacteria was not detected. As a result of testing microorganism variation depending on pH (2-5) of seasoning fluid (condiment), pH 3-4 was determined as pH of seasoning fluid as all the bacteria was not detected in pH3-4. As a result of testing air-borne bacteria (number of general bacteria, colon bacillus, fungus) depending on each workplace, number of microorganism of internal packing room, seasoning fluid processing room, washing room and storage room was detected to be 10 CFU/Plate, 2 CFU/Plate, 60 CFU/Plate and 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of general bacteria and colon bacillus was represented to be high as 346 $CFU/Cm^2$ and 23 $CFU/Cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, colon bacillus was not detected in all the specimen but general bacteria was most dominantly detected in PP Packing machine and Siuping machine (PE Bulk) as $4.2{\times}10^3CFU/Cm^2$, $2.6{\times}10^3CFU/Cm^2$, respectively. As a result of analyzing above hazardous factors, processing process of seasoning fluid where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and threshold level (critical control point) was set at pH 3-4. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.